Magnetic Resonance in Medicine | 2008
Emine Ulku Saritas; Jin Hyung Lee; Eric T. Han; Dwight G. Nishimura
Single‐shot echo‐planar imaging (ss‐EPI) has not been used widely for diffusion‐weighted imaging (DWI) of the spinal cord, because of the magnetic field inhomogeneities around the spine, the small cross‐sectional size of the spinal cord, and the increased motion in that area due to breathing, swallowing, and cerebrospinal fluid (CSF) pulsation. These result in artifacts with the usually long readout duration of the ss‐EPI method. Reduced field‐of‐view (FOV) methods decrease the required readout duration for ss‐EPI, thereby enabling its practical application to imaging of the spine. In this work, a reduced FOV single‐shot diffusion‐weighted echo‐planar imaging (ss‐DWEPI) method is proposed, in which a 2D spatially selective echo‐planar RF excitation pulse and a 180° refocusing pulse reduce the FOV in the phase‐encode (PE) direction, while suppressing the signal from fat simultaneously. With this method, multi slice images with higher in‐plane resolutions (0.94 × 0.94 mm2 for sagittal and 0.62 × 0.62 mm2 for axial images) are achieved at 1.5 T, without the need for a longer readout. Magn Reson Med 60:468–473, 2008.
IEEE Transactions on Medical Imaging | 2015
R. Matthew Ferguson; Amit P. Khandhar; Scott J. Kemp; Hamed Arami; Emine Ulku Saritas; Laura R. Croft; Justin J. Konkle; Patrick W. Goodwill; Aleksi Halkola; Jürgen Rahmer; Jörn Borgert; Steven M. Conolly
Magnetic particle imaging (MPI) shows promise for medical imaging, particularly in angiography of patients with chronic kidney disease. As the first biomedical imaging technique that truly depends on nanoscale materials properties, MPI requires highly optimized magnetic nanoparticle tracers to generate quality images. Until now, researchers have relied on tracers optimized for MRI T2*-weighted imaging that are sub-optimal for MPI. Here, we describe new tracers tailored to MPIs unique physics, synthesized using an organic-phase process and functionalized to ensure biocompatibility and adequate in vivo circulation time. Tailored tracers showed up to 3 × greater signal-to-noise ratio and better spatial resolution than existing commercial tracers in MPI images of phantoms.
IEEE Transactions on Medical Imaging | 2012
Patrick W. Goodwill; Justin J. Konkle; Bo Zheng; Emine Ulku Saritas; Steven M. Conolly
Projection magnetic particle imaging (MPI) can improve imaging speed by over 100-fold over traditional 3-D MPI. In this work, we derive the 2-D x-space signal equation, 2-D image equation, and introduce the concept of signal fading and resolution loss for a projection MPI imager. We then describe the design and construction of an x-space projection MPI scanner with a field gradient of 2.35 T/m across a 10 cm magnet free bore. The system has an expected resolution of 3.5 × 8.0 mm using Resovist tracer, and an experimental resolution of 3.8 × 8.4 mm resolution. The system images 2.5 cm × 5.0 cm partial field-of views (FOVs) at 10 frames/s, and acquires a full field-of-view of 10 cm × 5.0 cm in 4 s. We conclude by imaging a resolution phantom, a complex “Cal” phantom, mice injected with Resovist tracer, and experimentally confirm the theoretically predicted x-space spatial resolution.
American Journal of Neuroradiology | 2011
Greg Zaharchuk; Emine Ulku Saritas; Jalal B. Andre; Cynthia Chin; Jarrett Rosenberg; Thomas J. Brosnan; A. Shankaranarayan; Dwight G. Nishimura; Nancy J. Fischbein
BACKGROUND AND PURPOSE: DWI of the spinal cord is challenging because of its small size and artifacts associated with the most commonly used clinical imaging method, SS-EPI. We evaluated the performance of rFOV spinal cord DWI and compared it with the routine fFOV SS-EPI in a clinical population. MATERIALS AND METHODS: Thirty-six clinical patients underwent 1.5T MR imaging examination that included rFOV SS-EPI DWI of the cervical spinal cord as well as 2 comparison diffusion sequences: fFOV SS-EPI DWI normalized for either image readout time (low-resolution fFOV) or spatial resolution (high-resolution fFOV). ADC maps were created and compared between the methods by using single-factor analysis of variance. Two neuroradiologists blinded to sequence type rated the 3 DWI methods, based on susceptibility artifacts, perceived spatial resolution, signal intensity–to-noise ratio, anatomic detail, and clinical utility. RESULTS: ADC values for the rFOV and both fFOV sequences were not statistically different (rFOV: 1.01 ± 0.18 × 10−3 mm2/s; low-resolution fFOV: 1.12 ± 0.22 × 10−3 mm2/s; high-resolution fFOV: 1.10 ± 0.21 × 10−3 mm2/s; F = 2.747, P > .05). The neuroradiologist reviewers rated the rFOV diffusion images superior in terms of all assessed measures (P < 0.0001). Particular improvements were noted in patients with metal hardware, degenerative disease, or both. CONCLUSIONS: rFOV DWI of the spinal cord overcomes many of the problems associated with conventional fFOV SS-EPI and is feasible in a clinical population. From a clinical standpoint, images were deemed superior to those created by using standard fFOV methods.
Scientific Reports | 2015
Bo Zheng; Tandis Vazin; Patrick W. Goodwill; Anthony Conway; Aradhana Verma; Emine Ulku Saritas; David V. Schaffer; Steven M. Conolly
We demonstrate that Magnetic Particle Imaging (MPI) enables monitoring of cellular grafts with high contrast, sensitivity, and quantitativeness. MPI directly detects the intense magnetization of iron-oxide tracers using low-frequency magnetic fields. MPI is safe, noninvasive and offers superb sensitivity, with great promise for clinical translation and quantitative single-cell tracking. Here we report the first MPI cell tracking study, showing 200-cell detection in vitro and in vivo monitoring of human neural graft clearance over 87 days in rat brain.
IEEE Transactions on Medical Imaging | 2013
Emine Ulku Saritas; Patrick W. Goodwill; George Zhang; Steven M. Conolly
For magnetic particle imaging (MPI), specific absorption rate (SAR) and more critically magnetostimulation (i.e., dB/dt) safety limits will determine the optimal scan parameters, such as the drive field strength and frequency. These parameters will impact the scanning speed, field-of-view (FOV) and signal-to-noise ratio in MPI. Understanding the potential safety hazards of the drive field is critical for scaling MPI for human use. In this work, we demonstrate that magnetostimulation is the primary magnetic safety consideration in MPI, and we describe the first human-subject magnetostimulation threshold experiments for MPI using homogeneous coils. Our experiments, performed on the arm and leg, indicate that magnetostimulation thresholds monotonically decrease with increasing frequency. Additionally, we show for the first time that a strong inverse correlation exists between the threshold and the body part size. The chronaxie time, on the other hand, did not vary with body part size. We conclude with an estimation of the magnetostimulation thresholds for a full-body MPI scanner: a mean asymptotic threshold of 14.3 mT-pp (peak-to-peak) with a mean chronaxie time of 289 μs, which correspond to a magnetostimulation threshold of about 15 mT-pp for frequencies between 25 and 50 kHz. These findings will have a great impact on the optimization of MPI parameters, especially in determining the number of partial FOVs required to cover a region of interest.
Magnetic Resonance in Medicine | 2008
Jin Hyung Lee; Serge O. Dumoulin; Emine Ulku Saritas; Gary H. Glover; Brian A. Wandell; Dwight G. Nishimura; John M. Pauly
Passband balanced‐steady‐state free precession (b‐SSFP) fMRI is a recently developed method that utilizes the passband (flat portion) of the b‐SSFP off‐resonance response to measure MR signal changes elicited by changes in tissue oxygenation following increases in neuronal activity. Rapid refocusing and short readout durations of b‐SSFP, combined with the relatively large flat portion of the b‐SSFP off‐resonance spectrum allows distortion‐free full‐brain coverage with only two acquisitions. This allows for high‐resolution functional imaging, without the spatial distortion frequently encountered in conventional high‐resolution functional images. Finally, the 3D imaging compatibility of the b‐SSFP acquisitions permits isotropic‐voxel‐size high‐resolution acquisitions. In this study we address some of the major technical issues involved in obtaining passband b‐SSFP‐based functional brain images with practical imaging parameters and demonstrate the advantages through breath‐holding and visual field mapping experiments. Magn Reson Med, 2008.
IEEE Transactions on Medical Imaging | 2013
Kuan Lu; Patrick W. Goodwill; Emine Ulku Saritas; Bo Zheng; Steven M. Conolly
Magnetic Particle Imaging (MPI) is a promising tracer imaging modality that employs a kidney-safe contrast agent and does not use ionizing radiation. MPI already shows high contrast and sensitivity in small animal imaging, with great potential for many clinical applications, including angiography, cancer detection, inflammation imaging, and treatment monitoring. Currently, almost all clinically relevant imaging techniques can be modeled as systems with linearity and shift invariance (LSI), characteristics crucial for quantification and diagnostic utility. In theory, MPI has been proven to be LSI. However, in practice, high-pass filters designed to remove unavoidable direct feedthrough interference also remove information crucial to ensuring LSI in MPI scans. In this work, we present a complete theoretical and experimental description of the image artifacts from filtering. We then propose and validate a robust algorithm to completely restore the lost information for the x-space MPI method. We provide the theoretical, simulated, and experimental proof that our algorithm indeed restores the LSI properties of MPI.
Magnetic Resonance Imaging | 2015
Natalie Korn; John Kurhanewicz; Suchandrima Banerjee; Olga Starobinets; Emine Ulku Saritas; Susan M. Noworolski
The purposes of this study were to determine if image distortion is less in prostate MR apparent diffusion coefficient (ADC) maps generated from a reduced-field-of-view (rFOV) diffusion-weighted-imaging (DWI) technique than from a conventional DWI sequence (CONV), and to determine if the rFOV ADC tumor contrast is as high as or better than that of the CONV sequence. Fifty patients underwent a 3T MRI exam. CONV and rFOV (utilizing a 2D, echo-planar, rectangularly-selective RF pulse) sequences were acquired using b=600, 0s/mm(2). Distortion was visually scored 0-4 by three independent observers and quantitatively measured using the difference in rectal wall curvature between the ADC maps and T2-weighted images. Distortion scores were lower with the rFOV sequence (p<0.012, Wilcoxon Signed-Rank Test, n=50), and difference in distortion scores did not differ significantly among observers (p=0.99, Kruskal-Wallis Rank Sum Test). The difference in rectal curvature was less with rFOV ADC maps (26%±10%) than CONV ADC maps (34%±13%) (p<0.011, Students t-test). In seventeen patients with untreated, biopsy confirmed prostate cancer, the rFOV sequence afforded significantly higher ADC tumor contrast (44.0%) than the CONV sequence (35.9%), (p<0.0012, Students t-test). The rFOV sequence yielded significantly decreased susceptibility artifact and significantly higher contrast between tumor and healthy tissue.
IEEE Transactions on Medical Imaging | 2011
Tolga Çukur; Michael Lustig; Emine Ulku Saritas; Dwight G. Nishimura
Magnetization-prepared acquisitions offer a trade-off between image contrast and scan efficiency for magnetic resonance imaging. Because the prepared signals gradually decay, the contrast can be improved by frequently repeating the preparation, which in turn significantly increases the scan time. A common solution is to perform the data collection progressing from low- to high-spatial-frequency samples following each preparation. Unfortunately, this leads to loss of spatial resolution, and thereby image blurring. In this work, a new technique is proposed that first corrects the signal decay in high-frequency data to mitigate the resolution loss and improve the image contrast without reducing the scan efficiency. The proposed technique then employs a sparsity-based nonlinear reconstruction to further improve the image quality. In addition to reducing the amplified high-frequency noise, this reconstruction extrapolates missing k-space samples in the case of undersampled compressed-sensing acquisitions. The technique is successfully demonstrated for noncontrast-enhanced flow-independent angiography of the lower extremities, an application that substantially benefits from both the signal compensation and the nonlinear reconstruction.