Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Emmelie Stock is active.

Publication


Featured researches published by Emmelie Stock.


Theranostics | 2015

Theranostic mRNA-loaded Microbubbles in the Lymphatics of Dogs: Implications for Drug Delivery

Heleen Dewitte; Katrien Vanderperren; Hendrik Haers; Emmelie Stock; Luc Duchateau; Myriam Hesta; Jimmy Saunders; Stefaan C. De Smedt; Ine Lentacker

Microbubbles have shown potential as intralymphatic ultrasound contrast agents while nanoparticle-loaded microbubbles are increasingly investigated for ultrasound-triggered drug and gene delivery. To explore whether mRNA-nanoparticle loaded microbubbles could serve as theranostics for detection of and mRNA transfer to the lymph nodes, we investigate the behavior of unloaded and mRNA-loaded microbubbles using contrast-enhanced ultrasound imaging after subcutaneous injection in dogs. Our results indicate that both types of microbubbles are equally capable of rapidly entering the lymph vessels and nodes upon injection, and novel, valuable and detailed information on the lymphatic structure in the animals could be obtained. Furthermore, additional observations were made regarding the dynamics of microbubble lymph node uptake. Importantly, neither the microbubble migration distance within the lymphatics, nor the observed contrast signal intensity was influenced by mRNA-loading. Although further optimization of acoustic parameters will be needed, this could represent a first step towards ultrasound-guided, ultrasound-triggered intranodal mRNA delivery using these theranostic microbubbles.


Veterinary Journal | 2014

The effect of anesthesia with propofol and sedation with butorphanol on quantitative contrast-enhanced ultrasonography of the healthy feline kidney

Emmelie Stock; Katrien Vanderperren; Elke Van der Vekens; Hendrik Haers; Luc Duchateau; Ingeborgh Polis; Myriam Hesta; Jimmy Saunders

Contrast-enhanced ultrasonography of the left kidney was performed using a commercial contrast agent in six healthy adult purpose-bred cats. A cross-over design was used to compare three protocols: (1) awake, (2) butorphanol (0.4 mg/kg IM), and (3) propofol (3.5-7.7 mg/kg IV boluses to effect). Time-intensity curves were created from two regions-of-interest drawn in the renal cortex. The curves were analyzed for blood flow parameters representing blood volume (base intensity, peak intensity, area-under-curve) and blood velocity (arrival time, time-to-peak, wash-in/out). There was no difference in the subjective enhancement pattern between the three protocols. No significant effect of butorphanol was observed in any of the perfusion parameters (P > 0.05). Propofol did not influence the most important perfusion parameter, area-under-the-curve, and is adequate for use in contrast-enhanced ultrasound studies.


Veterinary and Comparative Oncology | 2017

Intratumoural interleukin 12 gene therapy stimulates the immune system and decreases angiogenesis in dogs with spontaneous cancer

Laetitia Cicchelero; Sofie Denies; Hendrik Haers; Katrien Vanderperren; Emmelie Stock; L. Van Brantegem; H. de Rooster; Niek N. Sanders

Interleukin 12 (IL-12) is a powerful immunostimulatory cytokine with a strong antitumoural activity. In this work, the immunological, anti-angiogenic and clinical effects of three consecutive intratumoural IL-12 electrogene therapy (EGT) treatments were evaluated in nine dogs with spontaneous cancer. In all the dogs, tumour biopsies and blood samples were taken prior, during and after the intratumoural IL-12 EGT (on days 1, 8, 35 and 1, 3, 8, 15, 35, respectively). An initial decrease in immune cells was followed by an increase above baseline 1-3 weeks after treatment initiation. Interestingly, the decrease in peripheral leukocytes 2 days after the first intratumoural IL-12 EGT coincided with erythema and tumour swelling. Transient increases of IL-12 and interferon γ were measured in the serum and the tumour tissue, whereas IL-10 transiently increased only in the serum. The effect of intratumoural IL-12 EGT on the levels of IL-24 and vascular endothelial growth factor in the sera and tumour biopsies differed per dog. Via contrast-enhanced ultrasound (US) (on days 1, 8 and 35), we demonstrated that intratumoural IL-12 EGT resulted in a significant decrease of the relative blood volume and blood flow speed in the tumour compared with baseline. Metastases were present in two dogs. In one of these dogs, IL-12 EGT of the primary tumour caused a transient partial regression of the metastases, but not of the primary tumour. The second dog with metastases did not survive long enough to complete the entire treatment cycle. Despite encouraging immunostimulatory and anti-angiogenic effects after intratumoural IL-12 EGT, no clinically relevant outcomes were observed in this study, as persistent tumour regression could not be obtained. On the other hand, the laboratory and US results hold great promise for combinatorial strategies of intratumoural IL-12 EGT with conventional antitumour (immuno)therapies.


Ultrasound in Medicine and Biology | 2017

Quantitative Differences Between the First and Second Injection of Contrast Agent in Contrast-Enhanced Ultrasonography of Feline Kidneys and Spleen

Emmelie Stock; Katrien Vanderperren; Hendrik Haers; Luc Duchateau; Myriam Hesta; Jimmy Saunders

Contrast-enhanced ultrasound is a valuable and safe technique for the evaluation of organ perfusion. Repeated injections of ultrasound contrast agent are often administered during the same imaging session. However, it remains unclear if quantitative differences are present between the consecutive microbubble injections. Therefore, the first and second injection of contrast agent for the left renal cortex, renal medulla and the splenic parenchyma in healthy cats were compared. A lower peak intensity and area under the curve were observed for the first injection of contrast agent in the feline kidney, both for the renal cortex and medulla, and spleen. Moreover, for the renal cortex, the time-intensity curve was steeper after the second injection. Findings from the present study demonstrate that a second injection of contrast agent provides stronger enhancement. The exact mechanism behind our findings remains unclear; however, saturation of the lung macrophages is believed to play an important role.


PLOS ONE | 2016

Evaluation of feline renal perfusion with contrast-enhanced ultrasonography and scintigraphy

Emmelie Stock; Katrien Vanderperren; Tim Bosmans; André Dobbeleir; Luc Duchateau; Myriam Hesta; Lien Lybaert; Kathelijne Peremans; Eva Vandermeulen; Jimmy Saunders

Contrast-enhanced ultrasound (CEUS) is an emerging technique to evaluate tissue perfusion. Promising results have been obtained in the evaluation of renal perfusion in health and disease, both in human and veterinary medicine. Renal scintigraphy using 99mTc-Mercaptoacetyltriglycine (MAG3) is another non-invasive technique that can be used to evaluate renal perfusion. However, no data are available on the ability of CEUS or 99mTc- MAG3 scintigraphy to detect small changes in renal perfusion in cats. Therefore, both techniques were applied in a normal feline population to evaluate detection possibilities of perfusion changes by angiotensin II (AT II). Contrast-enhanced ultrasound using a bolus injection of commercially available contrast agent and renal scintigraphy using 99mTc-MAG3 were performed in 11 healthy cats after infusion of 0,9% NaCl (control) and AT II. Angiotensin II induced changes were noticed on several CEUS parameters. Mean peak enhancement, wash-in perfusion index and wash-out rate for the entire kidney decreased significantly after AT II infusion. Moreover, a tendency towards a lower wash-in area-under-the curve was present. Renal scintigraphy could not detect perfusion changes induced by AT II. This study shows that CEUS is able to detect changes in feline renal perfusion induced by AT II infusion.


Journal of Feline Medicine and Surgery | 2014

Ultrasonographical examination of feline adrenal glands: intra- and inter-observer variability

Anaïs Combes; Emmelie Stock; Elke Van der Vekens; Luc Duchateau; Bernadette Van Ryssen; Jimmy Saunders

Interpretation of ultrasonographical measurements requires an understanding of the source and the magnitude of variation. A substantial part of the variation can be attributed to the observer, the equipment or the animal. The aim of this study was to evaluate which adrenal gland measurement is the least variable within and between observers. Three experienced ultrasonographers examined six cats at three different times on the same day, more than 1 h apart, according to a strict scanning protocol. Seven ultrasonographical measurements were performed on each adrenal gland (maximal length on sagittal images, maximal height at the cranial and caudal poles on sagittal and transverse images, and maximal width of the cranial and caudal poles on transverse images). Height measurements in both planes showed the lowest variability within and between observers compared with length and width measurements. Descriptive ultrasonographical features, such as echogenicity of the gland, presence of hyperechoic spots or layering assessment, demonstrated satisfactory-to-good intra- and inter-observer agreement, whereas the shape assessment showed very poor inter-observer agreement. The results of this study describe a reliable scanning protocol that can be the basis for future adrenal ultrasonographical examinations for cats suspected of adrenal disease (eg, hyperaldosteronism, hyperadrenocorticism, sex hormone-producing tumours).


Cancer Letters | 2017

Immunological, anti-angiogenic and clinical effects of intratumoral interleukin 12 electrogene therapy combined with metronomic cyclophosphamide in dogs with spontaneous cancer: A pilot study.

Laetitia Cicchelero; Sofie Denies; Katrien Vanderperren; Emmelie Stock; Leen Van Brantegem; Hilde De Rooster; Niek N. Sanders

The immunological, anti-angiogenic and clinical effects of metronomic cyclophosphamide and 3 consecutive intratumoral interleukin (IL)-12 gene therapy (electrogene therapy (EGT)) treatments were evaluated in 6 dogs with spontaneous cancer. In all dogs, a decrease in peripheral leukocytes 2 days after IL-12 EGT coincided with erythema and swelling of the tumor. In the tumor, a transient increase in IL-12 levels was measured, whereas a continuous increase in interferon γ (IFNγ) and thrombospondin 1 (TSP-1) were determined in contrast to a continuous decrease in vascular endothelial growth factor (VEGF). In the serum, a transient increase in IL-12 and IL-10 levels were noted in contrast to a transient decrease in VEGF and TSP-1. The treatment resulted in a significant anti-angiogenic effect. Although all primary tumors continued to progress in time, this progression was slower than before treatment according to the contrast-enhanced ultrasound data. Besides the encouraging immunostimulatory and anti-angiogenic effects observed in all dogs we also noticed in 4 out of 6 dogs clinically relevant improvements in quality of life and weight. These results hold great promise for combinatorial strategies of IL-12 EGT and metronomic chemotherapy with conventional antitumor (immuno)therapies.


Equine Veterinary Journal | 2014

Computed tomographic features of lesions detected in horses with tarsal lameness

Els Raes; Hendrik‐Jan Bergman; B. Van Ryssen; Katrien Vanderperren; Emmelie Stock; Jimmy Saunders

REASONS FOR PERFORMING STUDY Tarsal pain is a common cause of hindlimb lameness in horses. Diagnosis can usually be made with radiography and ultrasonography; however, in some cases, these techniques are inconclusive and additional imaging is necessary. No studies describing computed tomography (CT) features of different tarsal lesions in horses with tarsal lameness are reported. OBJECTIVES Our aims were as follows: 1) to characterise CT abnormalities in horses with tarsal lameness; 2) to compare CT findings with those from other imaging techniques; and 3) to assess whether CT can help to diagnose tarsal pathology. STUDY DESIGN Retrospective case series. METHODS Computed tomography of the tarsus was performed on 15 horses (n = 17 joints) with tarsal lameness. The horses were divided into 3 groups depending on the reason for CT examination, as follows: 1) other imaging techniques were inconclusive; 2) evaluation of a fracture; or 3) other imaging techniques showed tarsal lesions, and CT was performed to assess whether additional lesions were present. RESULTS Group 1 included 7 horses. Lesions detected with CT included subchondral cyst-like lesions (2 horses); an osteolytic lesion in the cochlea tibiae (one horse); degenerative changes of the distal tarsal joints (2 horses); osteolytic lesions tarsometatarsal joint (one horse); and sclerosis of the third tarsal bone with a lesion of the tarsometatarsal interosseous ligament (one horse). In this group, CT provided information on the character and extent of the lesion that was not available with other imaging techniques. Computed tomography revealed more information about the extent and complexity of the fracture than radiography in Group 2, whereas CT did not provide extra information in Group 3. CONCLUSIONS Focal lesions located between the tarsal bone surfaces are difficult or even impossible to detect with radiography and ultrasonography, but they can be detected and characterised with CT. POTENTIAL RELEVANCE Computed tomography of the tarsus should be considered when radiography and ultrasonography are inconclusive, or for further evaluation of tarsal fractures.


Veterinary Radiology & Ultrasound | 2016

EFFECT OF SEDATION ON CONTRAST-ENHANCED ULTRASONOGRAPHY OF THE SPLEEN IN HEALTHY DOGS

Federica Rossi; Caroline Fina; Emmelie Stock; Katrien Vanderperren; Luc Duchateau; Jimmy Saunders

Contrast-enhanced ultrasound of the spleen enables the dynamic assessment of the perfusion of this organ, however, both subjective and quantitative evaluation can be strongly influenced by sedative agent administration. The purpose of this prospective, experimental study was to test effects of two sedative agents on splenic perfusion during contrast-enhanced ultrasound of the spleen in a sample of healthy dogs. Contrast-enhanced ultrasound of the spleen was repeated in six healthy Beagles following a cross-over study design comparing three protocols: awake, butorphanol 0.2 mg/Kg intramuscular (IM), and dexmedetomidine 500 μg/m(2) IM. After intravenous injection of a phospholipid stabilized sulfur hexafluoride microbubble solution (SonoVue®, Bracco Imaging, Milano, Italy), the enhancement intensity and perfusion pattern of the splenic parenchyma were assessed and perfusion parameters were calculated. Normal spleen was slightly heterogeneous in the early phase, but the parenchyma was homogeneous at a later phase. Sedation with butorphanol did not modify perfusion of the spleen. Dexmedetomidine significantly reduced splenic enhancement, providing diffuse parenchymal hypoechogenicity during the entire examination. Measured parameters were significantly modified, with increased arrival time (AT; (< 0.0001) and time to peak (TTP; P < 0.0001), and decreased peak intensity (PI; P = 0.0108), wash-in (P = 0.0014), and area under the curve (AUC; P = 0.0421). Findings supported the use of butorphanol and contraindicated the use of dexmedetomidine as sedatives for splenic contrast ultrasound procedures in dogs. Short-term and diffuse heterogeneity of the spleen in the early venous phase was determined to be a normal finding.


Ultrasound in Medicine and Biology | 2018

Repeatability of Contrast-Enhanced Ultrasonography of the Kidneys in Healthy Cats

Emmelie Stock; Luc Duchateau; Jimmy Saunders; Veerle Volckaert; Ingeborgh Polis; Katrien Vanderperren

Contrast-enhanced ultrasound can be used to image and quantify tissue perfusion. It holds great potential for the use in the diagnosis of various diffuse renal diseases in both human and veterinary medicine. Nevertheless, the technique is known to have an inherent relatively high variability, related to various factors associated with the patient, the contrast agent and machine settings. Therefore, the aim of this study was to assess week-to-week intra- and inter-cat variation of several perfusion parameters obtained with CEUS of both kidneys of 12 healthy cats. Repeatability was determined by calculating the coefficient of variation (CV). The contrast-enhanced ultrasound parameters with the lowest variation for the renal cortex were time-to-peak (CV 6.0%), rise time (CV 13%), fall time (CV 19%) and mean transit time (24%). Intensity-related parameters and parameters related to the slope of the time-intensity curve had a CV of >35%. Lower repeatability was present for perfusion parameters derived from the renal medulla compared with the renal cortex. Normalization to the inter-lobar artery does not cause a reduction in variation. In conclusion, time-related parameters for the cortex show a reasonable repeatability; whereas poor repeatability is present for intensity-related parameters and parameters related to in- and outflow of contrast agent. Poor repeatability is also present for all perfusion parameters for the renal medulla, except for time to peak, which has a good repeatability.

Collaboration


Dive into the Emmelie Stock's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge