Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Eric Jobiliong is active.

Publication


Featured researches published by Eric Jobiliong.


Applied Spectroscopy | 2015

Spectral and Dynamic Characteristics of Helium Plasma Emission and its Effect on a Laser-Ablated Target Emission in a Double-Pulse Laser-Induced Breakdown Spectroscopy (LIBS) Experiment

Eric Jobiliong; Hery Suyanto; Alion Mangasi Marpaung; Syahrun Nur Abdulmadjid; Nasrullah Idris; Rinda Hedwig; Muliadi Ramli; Marincan Pardede; Maria Margaretha Suliyanti; Kiichiro Kagawa; Ken-ichi Fukumoto; May On Tjia; Tjung Jie Lie; Zener Sukra Lie; Koo Hendrik Kurniawan

A systematic study has been performed on the spectral characteristics of the full spectrum of He emission lines and their time-dependent behaviors measured from the He gas plasmas generated by a nanosecond neodymium-doped yttrium aluminum garnet laser. It is shown that among the major emission lines observed, the triplet He(I) 587.6 nm emission line stands out as the most prominent and long-lasting line, associated with de-excitation of the metastable triplet (S = 1) excited state (1s 1 3d 1 ). The role of this metastable excited state is manifested in the intensity enhancement and prolonged life time of the Cu emission with narrow full width half-maximum, as demonstrated in an orthogonal double-pulse experiment using a picosecond laser for the target ablation and a nanosecond laser for the prior generation of the ambient He gas plasma. These desirable emission features are in dire contrast to the characteristics of emission spectra observed with N2 ambient gas having no metastable excited state, which exhibit an initial Stark broadening effect and rapid intensity diminution typical to thermal shock wave-induced emission. The aforementioned He metastable excited state is therefore responsible for the demonstrated favorable features. The advantage of using He ambient gas in the double-pulse setup is further confirmed by the emission spectra measured from a variety of samples. The results of this study have thus shown the potential of extending the existing laser-induced breakdown spectroscopy application to high-sensitivity and high-resolution spectrochemical analysis of wide-ranging samples with minimal destructive effect on the sample surface.


Journal of Applied Physics | 2011

Observation of exclusively He-induced H emission in cooled laser plasma

Zener Sukra Lie; Hideaki Niki; Kiichiro Kagawa; May On Tjia; Rinda Hedwig; Marincan Pardede; Eric Jobiliong; Maria Margaretha Suliyanti; Syahrun Nur Abdulmadjid; Koo Hendrik Kurniawan

An experiment was performed for the observation of H emission induced in a cooled laser-induced atmospheric pressure gas plasma of He atoms in their metastable excited state. The strong H emission detected clearly established, to the exclusion of other well known major excitation processes, the exclusive contribution of the He-induced excitation (HIE) mechanism. The process is suggested to take place by means of energy transfer from the excited He atoms to the H atoms via Penning collision induced ionization involving electron exchange. The result further shows that this mechanism may also work for elements other than H and thereby strongly suggests the use of ambient He gas to broaden and complement the applications of standard laser-induced breakdown spectroscopy.


Journal of Applied Physics | 2013

Direct evidence of mismatching effect on H emission in laser-induced atmospheric helium gas plasma

Zener Sukra Lie; May On Tjia; Rinda Hedwig; Maria Margaretha Suliyanti; Syahrun Nur Abdulmadjid; Nasrullah Idris; Alion Mangasi Marpaung; Marincan Pardede; Eric Jobiliong; Muliadi Ramli; Heri Suyanto; Ken-ichi Fukumoto; Kiichiro Kagawa; Koo Hendrik Kurniawan

A time-resolved orthogonal double pulse laser-induced breakdown spectroscopy (LIBS) with helium surrounding gas is developed for the explicit demonstration of time mismatch between the passage of fast moving impurity hydrogen atoms and the formation of thermal shock wave plasma generated by the relatively slow moving major host atoms of much greater masses ablated from the same sample. Although this so-called “mismatching effect” has been consistently shown to be responsible for the gas pressure induced intensity diminution of hydrogen emission in a number of LIBS measurements using different ambient gases, its explicit demonstration has yet to be reported. The previously reported helium assisted excitation process has made possible the use of surrounding helium gas in our experimental set-up for showing that the ablated hydrogen atoms indeed move faster than the simultaneously ablated much heavier major host atoms as signaled by the earlier H emission in the helium plasma generated by a separate laser pr...


Journal of Applied Physics | 2011

Deuterium analysis in zircaloy using ps laser-induced low pressure plasma

Alion Mangasi Marpaung; Zener Sukra Lie; Hideaki Niki; Kiichiro Kagawa; Ken-ichi Fukumoto; Muliadi Ramli; Syahrun Nur Abdulmadjid; Nasrullah Idris; Rinda Hedwig; May On Tjia; Marincan Pardede; Maria Margaretha Suliyanti; Eric Jobiliong; Koo Hendrik Kurniawan

An experimental study on picosecond laser induced plasma spectroscopy of a zircaloy sample with low-pressure surrounding helium gas has been carried out to demonstrate its potential applicability to three-dimensional quantitative micro-analysis of deuterium impurities in zircaloy. This was achieved by adopting the optimal experimental condition ascertained in this study, which is specified as 7 mJ laser energy, 1.3 kPa helium pressure, and 50 μs measurement window, and which was found to result in consistent D emission enhancement. Employing these operational parameters, a linear calibration line exhibiting a zero intercept was obtained from zircaloy-4 samples doped with various concentrations of D impurity, regarded as surrogates for H impurity. An additional measurement also yielded a detection limit of about 10 μg/g for D impurity, well below the acceptable threshold of damaging H concentration in zircaloy. Each of these measurements was found to produce a crater size of only 25 μm in diameter, promisi...


Applied Spectroscopy | 2010

Quantitative Deuterium Analysis of Titanium Samples in Ultraviolet Laser-Induced Low-Pressure Helium Plasma

Syahrun Nur Abdulmadjid; Zener Sukra Lie; Hideaki Niki; Marincan Pardede; Rinda Hedwig; Tjung Jie Lie; Eric Jobiliong; Koo Hendrik Kurniawan; Ken-ichi Fukumoto; Kiichiro Kagawa; May On Tjia

An experimental study of ultraviolet (UV) laser-induced plasma spectroscopy (LIPS) on Ti samples with low-pressure surrounding He gas has been carried out to demonstrate its applicability to quantitative micro-analysis of deuterium impurities in titanium without the spectral interference from the ubiquitous surface water. This was achieved by adopting the optimal experimental condition ascertained in this study, which is specified by 5 mJ laser energy, 10 Torr helium pressure, and 1–50 μs measurement window, which resulted in consistent D emission enhancement and effective elimination of spectral interference from surface water. As a result, a linear calibration line exhibiting a zero intercept was obtained from Ti samples doped with various D impurity concentrations. An additional measurement also yielded a detection limit of about 40 ppm for D impurity, well below the acceptable threshold of damaging H concentration in Ti and its alloys. Each of these measurements was found to produce a crater size of only 25 μm in diameter, and they may therefore qualify as nondestructive measurements. The result of this study has therefore paved the way for conducting further experiments with hydrogen-doped Ti samples and the technical implementation of quantitative micro-analysis of detrimental hydrogen impurity in Ti metal and its alloys, which is the ultimate goal of this study.


Journal of Applied Physics | 2015

Quantitative and sensitive analysis of CN molecules using laser induced low pressure He plasma

Marincan Pardede; Rinda Hedwig; Syahrun Nur Abdulmadjid; Kurnia Lahna; Nasrullah Idris; Eric Jobiliong; Hery Suyanto; Alion Mangasi Marpaung; Maria Margaretha Suliyanti; Muliadi Ramli; May On Tjia; Tjung Jie Lie; Zener Sukra Lie; Davy Putra Kurniawan; Koo Hendrik Kurniawan; Kiichiro Kagawa

We report the results of experimental study on CN 388.3 nm and C I 247.8 nm emission characteristics using 40 mJ laser irradiation with He and N2 ambient gases. The results obtained with N2 ambient gas show undesirable interference effect between the native CN emission and the emission of CN molecules arising from the recombination of native C ablated from the sample with the N dissociated from the ambient gas. This problem is overcome by the use of He ambient gas at low pressure of 2 kPa, which also offers the additional advantages of cleaner and stronger emission lines. The result of applying this favorable experimental condition to emission spectrochemical measurement of milk sample having various protein concentrations is shown to yield a close to linear calibration curve with near zero extrapolated intercept. Additionally, a low detection limit of 5 μg/g is found in this experiment, making it potentially applicable for quantitative and sensitive CN analysis. The visibility of laser induced breakdown spectroscopy with low pressure He gas is also demonstrated by the result of its application to spectrochemical analysis of fossil samples. Furthermore, with the use of CO2 ambient gas at 600 Pa mimicking the Mars atmosphere, this technique also shows promising applications to exploration in Mars.


Journal of Applied Physics | 2015

Excitation mechanisms in 1 mJ picosecond laser induced low pressure He plasma and the resulting spectral quality enhancement

Nasrullah Idris; Kurnia Lahna; Syahrun Nur Abdulmadjid; Muliadi Ramli; Hery Suyanto; Alion Mangasi Marpaung; Marincan Pardede; Eric Jobiliong; Rinda Hedwig; Maria Margaretha Suliyanti; Zener Sukra Lie; Tjung Jie Lie; Kiichiro Kagawa; May On Tjia; Koo Hendrik Kurniawan

We report in this paper the results of an experimental study on the spectral and dynamical characteristics of plasma emission induced by 1 mJ picoseconds (ps) Nd-YAG laser using spatially resolved imaging and time resolved measurement of the emission intensities of copper sample. This study has provided the experimental evidence concerning the dynamical characteristics of the excitation mechanisms in various stages of the plasma formation, which largely consolidate the basic scenarios of excitation processes commonly accepted so far. However, it is also clearly shown that the duration of the shock wave excitation process induced by ps laser pulses is much shorter than those observed in laser induced breakdown spectroscopy employing nanosecond laser at higher output energy. This allows the detection of atomic emission due exclusively to He assisted excitation in low pressure He plasma by proper gating of the detection time. Furthermore, the triplet excited state associated with He I 587.6 nm is shown to be...


Analytical Chemistry | 2017

H-D Analysis Employing Low-Pressure microjoule Picosecond Laser-Induced Breakdown Spectroscopy

Zener Sukra Lie; Marincan Pardede; Eric Jobiliong; Hery Suyanto; Davy Putra Kurniawan; Rinda Hedwig; Muliadi Ramli; Ali Khumaeni; Tjung Jie Lie; Koo Hendrik Kurniawan; Kiichiro Kagawa; May On Tjia

An experimental study is conducted in search of the much needed experimental method for practical and minimally destructive analysis of hydrogen (H) and deuterium (D) in a nuclear power plant. For this purpose, a picosecond (ps) Nd:YAG laser is employed and operated with 300-500 μJ output energies in a variety of ambient gases at various gas pressures. The sample chamber used is specially designed small quartz tube with an open end that can be tightly fitted to the sample surface. It is found that ambient Ar gas at reduced pressure of around 0.13 kPa gives the best spectral quality featuring fully resolved H and D emission lines with clearly detectable intensities and practically free from surface water interference. The D emission intensities measured from zircaloy plates containing various concentrations of D impurity are shown to yield a linear calibration line with extrapolated zero intercept, offering its potential application to quantitative analysis. The estimated detection limit of less than 10 ppm is well below the sensitivity limit of around 600 ppm required for the regular inspection of zircaloy tubes in a heavy water nuclear power plant. The use of the exceedingly low laser energy is shown to offer an additional advantage of minimum destructive effect marked by the resulted tiny craters of about 5 μm diameter with 25 μm depth. These results promise the potential development of the desired alternative analytical tool for regular in situ and real time inspection of the zircaloy tubes in a heavy water power plant.


Applied Spectroscopy | 2013

A Comparative Study of Pressure-Dependent Emission Characteristics in Different Gas Plasmas Induced by Nanosecond and Picosecond Neodymium-Doped Yttrium Aluminum Garnet (Nd:YAG) Lasers

Syahrun Nur Abdulmadjid; Nasrullah Idris; Alion Mangasi Marpaung; Marincan Pardede; Eric Jobiliong; Rinda Hedwig; Maria Margaretha Suliyanti; Muliadi Ramli; Heri Suyanto; Kiichiro Kagawa; May On Tjia; Zener Sukra Lie; Tjung Jie Lie; Hendrik Kurniawan

An experimental study has been performed on the pressure-dependent plasma emission intensities in Ar, He, and N2 surrounding gases with the plasma induced by either nanosecond (ns) or picosecond (ps) yttrium aluminum garnet laser. The study focused on emission lines of light elements such as H, C, O, and a moderately heavy element of Ca from an agate target. The result shows widely different pressure effects among the different emission lines, which further vary with the surrounding gases used and also with the different ablation laser employed. It was found that most of the maximum emission intensities can be achieved in Ar gas plasma generated by ps laser at low gas pressure of around 5 Torr. This experimental condition is particularly useful for spectrochemical analysis of light elements such as H, C, and O, which are known to suffer from intensity diminution at higher gas pressures. Further measurements of the spatial distribution and time profiles of the emission intensities of H I 656.2 nm and Ca II 396.8 nm reveal the similar role of shock wave excitation for the emission in both ns and ps laser-induced plasmas, while an additional early spike is observed in the plasma generated by the ps laser. The suggested preference of Ar surrounding gas and ps laser was further demonstrated by outperforming the ns laser in their applications to depth profiling of the H emission intensity and offering the prospect for the development of three-dimensional analysis of a light element such as H and C.


Review of Scientific Instruments | 2012

Note: Adhesive stamp electrodes using spider silk masks for electronic transport measurements of supra-micron sized samples

Eden Steven; Eric Jobiliong; P. M. Eugenio; J. S. Brooks

A procedure for fabricating adhesive stamp electrodes based on gold coated adhesive tape used to measure electronic transport properties of supra-micron samples in the lateral range 10-100 μm and thickness >1 μm is described. The electrodes can be patterned with a ~4 μm separation by metal deposition through a mask using Nephila clavipes spider dragline silk fibers. Ohmic contact is made by adhesive lamination of a sample onto the patterned electrodes. The performance of the electrodes with temperature and magnetic field is demonstrated for the quasi-one-dimensional organic conductor (TMTSF)(2)PF(6) and single crystal graphite, respectively.

Collaboration


Dive into the Eric Jobiliong's collaboration.

Top Co-Authors

Avatar

Marincan Pardede

University of Pelita Harapan

View shared research outputs
Top Co-Authors

Avatar

May On Tjia

Bandung Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Maria Margaretha Suliyanti

Indonesian Institute of Sciences

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge