Eric Lacot
Centre national de la recherche scientifique
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Eric Lacot.
Optics Letters | 1999
Eric Lacot; R. Day; F. Stoeckel
We describe a new method for imaging in three-dimensional turbid media, laser optical feedback tomography. This technique is based on the resonant sensitivity of a short-cavity laser to frequency-shifted optical feedback from ballistic photons retrodiffused from the medium. The advantage of the method is that the detector is the laser source itself, which provides optical amplification with self-aligned spatial and temporal coherent detection.
Optics Letters | 2001
Eric Lacot; R. Day; J. Pinel; F. Stoeckel
We describe a new imaging technique based on modification of laser relaxation frequency induced by coherent optical feedback from an external target. A direct comparison (both theoretical and experimental) is made with laser feedback interferometry techniques, in which there is a modification of the lasers steady state. We show that, for a laser with a cavity damping rate gamma(c) higher than the population damping rate, gamma(1) , the modification of the laser relaxation frequency can be several orders of magnitude more sensitive than the perturbation of the lasers output power. Application of this technique to imaging is reported.
Optics Express | 2008
Sylvain Blaize; Baptiste Bérenguier; Ilan Stéfanon; Aurélien Bruyant; Gilles Lerondel; Pascal Royer; Olivier Hugon; Olivier Jacquin; Eric Lacot
The use of laser optical feedback Imaging (LOFI) for scattering-type scanning near-field optical microscopy (sSNOM) is proposed and investigated. We implement this sensitive imaging method by combining a sSNOM with optical heterodyne interferometry and the dynamic properties of a B class laser source which is here used both as source and detector. Compared with previous near field optical heterodyne experiments, this detection scheme provides an optical amplification that is several orders of magnitude higher, while keeping a low noise phase-sensitive detection. Successful demonstration of this complex field imaging technique is done on Silicon on Insulator (SOI) optical waveguides revealing phase singularities and directional leakage.
Ultramicroscopy | 2011
Olivier Hugon; F. Joud; Eric Lacot; Olivier Jacquin; H. Guillet de Chatellus
The application of the non-conventional imaging technique LOFI (laser optical feedback imaging) to coherent microscopy is presented. This simple and efficient technique using frequency-shifted optical feedback needs the sample to be scanned in order to obtain an image. The effects on magnitude and phase signals such as vignetting and field curvature occasioned by the scanning with galvanometric mirrors are discussed. A simple monitoring method based on phase images is proposed to find the optimal position of the scanner. Finally, some experimental results illustrating this technique are presented.
Journal of The Optical Society of America A-optics Image Science and Vision | 2011
Olivier Jacquin; Eric Lacot; Wilfried Glastre; Olivier Hugon; Hugues Guillet de Chatellus
Using an Nd:YVO₄ microchip laser with a relaxation frequency in the megahertz range, we have experimentally compared a heterodyne interferometer based on a Michelson configuration with an autodyne interferometer based on the laser optical feedback imaging (LOFI) method regarding their signal-to-noise ratios. In the heterodyne configuration, the beating between the reference beam and the signal beam is realized outside the laser cavity, while in the autodyne configuration, the wave beating takes place inside the laser cavity, and the relaxation oscillations of the laser intensity then play an important part. For a given laser output power, object under investigation, and detection noise level, we have determined the amplification gain of the LOFI interferometer compared to the heterodyne interferometer. LOFI interferometry is demonstrated to show higher performance than heterodyne interferometry for a wide range of laser powers and detection levels of noise. The experimental results are in good agreement with the theoretical predictions.
Optics Letters | 2006
Arnaud Witomski; Eric Lacot; Olivier Hugon; Olivier Jacquin
We describe a new one-dimensional synthetic aperture imaging laser radar (ladar) using the resonant sensitivity of a microchip laser to frequency-shifted optical feedback and galvanometric scanning of the target under investigation. In our experiment, the laser is both the source and the detector, providing optical amplification with self-aligned heterodyne detection. By using galvanometric scanning, we achieve an along-track spatial resolution better than the diffraction limit.
Optics Express | 2013
Wilfried Glastre; Olivier Hugon; Olivier Jacquin; Hugues Guillet de Chatellus; Eric Lacot
A new kind of plenoptic imaging system based on Laser Optical Feedback Imaging (LOFI) is presented and is compared to another previously existing device based on microlens array. Improved photometric performances, resolution and depth of field are obtained at the price of a slow point by point scanning. Main properties of plenoptic microscopes such as numerical refocusing on any curved surface or aberrations compensation are both theoretically and experimentally demonstrated with a LOFI-based device.
Optics Express | 2013
H. Guillet de Chatellus; Olivier Jacquin; Olivier Hugon; Wilfried Glastre; Eric Lacot; Jens Marklof
We show both theoretically and experimentally that frequency-shifted feedback (FSF) lasers seeded with a single frequency laser can generate Fourier transform-limited pulses with a repetition rate tunable and limited by the spectral bandwidth of the laser. We demonstrate experimentally in a FSF laser with a 150 GHz spectral bandwidth, the generation of 6 ps-duration pulses at repetition rates tunable over more than two orders of magnitude between 0.24 and 37 GHz, by steps of 80 MHz. A simple linear analytical model i.e. ignoring both dynamic and non-linear effects, is sufficient to account for the experimental results. This possibility opens new perspectives for various applications where lasers with ultra-high repetition rates are required, from THz generation to ultrafast data processing systems.
Journal of The Optical Society of America A-optics Image Science and Vision | 2012
Wilfried Glastre; Olivier Jacquin; Olivier Hugon; Hugues Guillet de Chatellus; Eric Lacot
In this paper we present an experimental setup based on laser optical feedback imaging (LOFI) and on synthetic aperture with translational scanning by galvanometric mirrors for the purpose of making deep and resolved images through scattering media. We provide real two-dimensional optical synthetic aperture image of a fixed scattering target with a moving aperture and an isotropic resolution. We demonstrate theoretically and experimentally that we can keep microscope resolution beyond the working distance. A photometric balance is made, and we show that the number of photons participating in the final image decreases with the square of the reconstruction distance. This degradation is partially compensated by the high sensitivity of LOFI.
Applied Optics | 2009
Olivier Jacquin; Samuel Heidmann; Eric Lacot; Olivier Hugon
We propose a new optical architecture for the laser optical feedback imaging (LOFI) technique which makes it possible to avoid the adverse effect of the optical parasitic backscattering introduced by all the optical interfaces located between the laser source and the studied object. This proposed setup needs no specific or complex alignment, which is why we can consider the proposed setup to be self-aligned. We describe the principle used to avoid the parasitic backscattering contributions that dramatically deteriorate amplitude and phase information contained in the LOFI images. Finally, we give a successful demonstration of amplitude and phase images obtained with this self-aligned setup in the presence of a parasitic reflection.