Journal of Endodontics | 2010
Isabella Faria da Cunha Peixoto; Érika Sales Joviano Pereira; Jacqueline Gonçalves da Silva; Ana Cecília Diniz Viana; Vicente Tadeu Lopes Buono; Maria Guiomar de Azevedo Bahia
INTRODUCTION The purpose of this study was to compare the flexural fatigue and torsional resistance of ProFile GT and GT Series X instruments, taking into account their structural and dimensional characteristics. METHODS Instrument diameter at each millimeter from the tip and pitch length were the dimensional parameters measured. Chemical composition was determined by energy-dispersive x-ray spectroscopy and phase constitution by x-ray diffraction. Vickers microhardness measurements were performed to assess instrument strength. One group of 20/.06 GT and GTX instruments (n = 10 each) was tested until failure in a flexural fatigue test device, whereas another group of 20/.04 files (n = 10 each) was tested in torsion based on ISO 3630-1. RESULTS GT and GTX instruments showed approximately the same chemical composition, namely 51at%Ni-49at%Ti (56wt%Ni-44wt%Ti) and contained mainly the beta-phase. GTX instruments showed higher intensity x-ray diffraction peaks and a statistically higher Vickers microhardness. There was a significant decrease in the diameter of GTX in relation to GT instruments from D6 to D9 for 20/.04 instruments and from D4 to D7 for 20/.06 instruments. Pitch length increased along the active part of both instruments, with a steeper increase in GTX. In general, GT Series X instruments were significantly more resistant to flexural fatigue than were similar GT instruments (p < 0.001) but exhibited lower torsional strength (p < 0.001). CONCLUSIONS Different structural and dimensional characteristics were found in GTX instruments in comparison with GT instruments; this is probably the cause for their higher flexural fatigue resistance and lower torsional strength.
International Endodontic Journal | 2008
Marta Chaves Craveiro de Melo; Érika Sales Joviano Pereira; Ana Cecília Diniz Viana; A. M. A. Fonseca; Vicente Tadeu Lopes Buono; Maria Guiomar de Azevedo Bahia
AIM To correlate the mechanical behaviour in torsion, bending and fatigue tests of K3 instruments with their dimensional characteristics. METHODOLOGY Instrument length, tip angle, distance between blades (pitch length) and the diameter at each millimetre from the tip of sizes 20, 25 and 30, 0.04 taper and sizes 20 and 25, 0.06 taper K3 rotary instruments were measured in an optical microscope equipped with digital micrometers. The cross-sectional area at 3 mm from the tip of the same instruments was determined using digital image analysis of scanning electron microscopy images. Maximum torque and angular deflection, as well as bending moment at 45 degrees were measured according to specification of ISO 3630-1. Fatigue resistance of instruments size 30, 0.04 taper, and sizes 20 and 25, 0.06 taper was determined in a fatigue test bench device. RESULTS The analysed instruments presented no uniformity in the distance between adjacent blades, but the measured diameters at each millimetre from the tip were regular, showing compliance with manufacturing standards. Torque and bending moment of the tested instruments increased significantly with diameter and cross-sectional area at 3 mm from the instrument tip. The fatigue resistance of the instruments showed a tendency to decrease as the diameter of the instruments increased. CONCLUSIONS The bending moment at 45 degrees and the torsional resistance of K3 instruments can be predicted using instrument diameter and cross-sectional area at 3 mm from the tip. Fatigue resistance decreased as the instrument diameter increased.
Dental Materials | 2013
Érika Sales Joviano Pereira; Renata O. Gomes; Agnès Marie Françoise Leroy; Rupinderpal Singh; Ove A. Peters; Maria Guiomar de Azevedo Bahia; Vicente Tadeu Lopes Buono
OBJECTIVE Comparison of physical and mechanical properties of one conventional and a new NiTi wire, which had received an additional thermomechanical treatment. METHODS Specimens of both conventional (NiTi) and the new type of wire, called M-Wire (MW), were subjected to tensile and three-point bending tests, Vickers microhardness measurements, and to rotating-bending fatigue tests at a strain-controlled level of 6%. Fracture surfaces were observed by scanning electron microscopy and the non-deformed microstructures by transmission electron microscopy. RESULTS The thermomechanical treatment applied to produce the M-Wire apparently increased the tensile strength and Vickers microhardness of the material, but its apparent Young modulus was smaller than that of conventionally treated NiTi. The three-point bending tests showed a higher flexibility for MW which also exhibited a significantly higher number of cycles to failure. SIGNIFICANCE M-Wire presented mechanical properties that can render endodontic instruments more flexible and fatigue resistant than those made with conventionally processed NiTi wires.
Journal of Endodontics | 2015
Érika Sales Joviano Pereira; Ana Cecília Diniz Viana; Vicente Tadeu Lopes Buono; Ove A. Peters; Maria Guiomar de Azevedo Bahia
INTRODUCTION The purpose of this study was to investigate if nickel-titanium instruments with similar designs manufactured by different thermal treatments would exhibit significantly different in vitro behavior. METHODS Thirty-six instruments each of ProTaper Universal (PTU F1; Dentsply Maillefer, Ballaigues, Switzerland), ProFile Vortex (PV; Dentsply Tulsa Dental Specialties, Tulsa, OK), Vortex Blue (VB, Dentsply Tulsa Dental Specialties), and TYPHOON Infinite Flex NiTi (TYP; Clinicians Choice Dental Products, New Milford, CT) (all size 25/.06) were evaluated. Bending resistance, torsion at failure, and dynamic torsional tests were performed with the instruments (n = 12). Analysis of variance and Tukey post hoc tests were applied. RESULTS Flexibility was significantly higher for TYP compared with the other 3 groups (P < .0001). With respect to the maximum torque at failure, PV group showed the highest resistance to twisting (torsional strength) among the analyzed instruments followed by VB, TYP, and PTU. The TYP group exhibited greater angular deflection at failure compared with the other groups (P < .0001). The mean dynamic torque scores during simulated canal preparation were highest for TYP (3.01 ± 0.71 Ncm) and lowest for PV (1.62 ± 0.79 Ncm). However, no significant differences were observed comparing groups PTU with TYP and VB and VB with PV (P > .05). The highest mean forces were recorded with PTU (7.02 ± 2.36 N) and the lowest with TYP (1.22 ± 0.40 N). CONCLUSIONS TYP instruments were significantly more flexible than the other instruments tested. The PV group had the highest torsional strength and TYP, despite being the most flexible, showed similar torsional moments to the other instruments, whereas its angular deflection was the highest among the groups.
Brazilian Dental Journal | 2012
Érika Sales Joviano Pereira; Isabella Faria da Cunha Peixoto; Rodrigo Keigo Lopes Nakagawa; Vicente Tadeu Lopes Buono; Maria Guiomar de Azevedo Bahia
This study evaluated the protocols of sonic and vacuum irrigation regarding the capacity of debris removal from root canal systems. Canal preparations were carried out on 30 mandibular first molars using the ProTaper Universal System. Teeth were divided into two experimental groups (n=15): Group 1: sonic irrigation and Group 2: vacuum irrigation protocol. Subsequently, the mesial roots were sectioned and observed by stereomicroscopy and scanning electron microscopy. Three independent examiners evaluated images of the apical thirds according to the following scores: 1= small presence of debris, 2= moderate presence of debris, and 3= dense presence of debris. Data were analyzed with ANOVA and Kruskal-Wallis tests (α=0.05). Comparison among the groups revealed that at the apical third, the root halves of Group 1 had significantly less surface debris (p=0.002) than those of Group 2. However, at 2 mm from the working length, Group 2s specimens showed less remaining debris in approximately 75% of the analyzed root canals. At the whole apical third, the sonic irrigation protocol removed significantly more debris than the vacuum protocol. However, in the region at 2 mm from the working length, the second irrigation method demonstrated a better performance.
International Endodontic Journal | 2012
Érika Sales Joviano Pereira; Isabella Faria da Cunha Peixoto; Ana Cecília Diniz Viana; I. I. Oliveira; B. M. Gonzalez; Vicente Tadeu Lopes Buono; Maria Guiomar de Azevedo Bahia
International Endodontic Journal | 2013
Ana Cecília Diniz Viana; Érika Sales Joviano Pereira; Maria Guiomar de Azevedo Bahia; Vicente Tadeu Lopes Buono
Journal of Endodontics | 2015
Isabella Faria da Cunha Peixoto; Érika Sales Joviano Pereira; Diego Pinheiro Aun; Vicente Tadeu Lopes Buono; Maria Guiomar de Azevedo Bahia
ABM Proceedings | 2018
Isabella Faria da Cunha Peixoto; Érika Sales Joviano Pereira; Diego Pinheiro Aun; Gustavo de Almeida Cristofaro; Maria Guiomar de Azevedo Bahia; Vicente Tadeu Lopes Buono
Arquivos em Odontologia | 2015
Evandro Pires Vieira; Érika Sales Joviano Pereira; Isabella Faria da Cunha Peixoto; Vicente Tadeu Lopes Buono; Maria Guiomar de Azevedo Bahia