Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Erinç Önem is active.

Publication


Featured researches published by Erinç Önem.


Dentomaxillofacial Radiology | 2012

Diagnostic accuracy of proximal enamel subsurface demineralization and its relationship with calcium loss and lesion depth

Erinç Önem; Bg Baksı; B H Şen; Ö Söğüt; Ali Mert

OBJECTIVE The aim of this study was to determine the relationship between the amount of calcium loss, lesion depth, and the accuracy of storage phosphor plate (SPP) and film radiographs for the detection of artificial proximal demineralization. METHODS Standard enamel windows of extracted premolars were exposed to a demineralizing solution for 60 h, 80 h, 100 h and 120 h. Solutions were analysed for calcium concentration by atomic absorption spectrometer and the lesion depths were calculated by a specific formula. All teeth were radiographed with SPPs and F-speed films before and after acid application. Images were evaluated by five observers. Stereomicroscopic and scanning electron microscopic (SEM) observations were carried out to visualize enamel surfaces after acid exposure. Receiver operating characteristic analysis was used for diagnostic accuracy (A(z)). A(z)s were compared with factorial analysis of variance and t-tests. The relationship between A(z)s and lesion depths was determined with Pearsons correlation test. RESULTS Strong positive correlation was found between A(z)s of both radiographic methods and lesion depths. No difference was found between the A(z)s of two radiographic systems for any of the demineralization durations (p > 0.05). Pair-wise comparisons revealed no significant difference in A(z)s of SPPs (p > 0.05), while significant differences were obtained for the A(z)s of films for different demineralization periods (p < 0.05). Stereomicroscopic and SEM observations confirmed demineralizations from superficial to deeper layers of enamel. CONCLUSION Subsurface enamel demineralization was not accurately detectable with either storage phosphor plates or F-speed films. The amount of calcium loss and the depth of demineralization have a strong relationship with diagnostic accuracy with a significant effect particularly on F-speed films.


Oral Surgery, Oral Medicine, Oral Pathology, and Oral Radiology | 2012

Diagnostic accuracy of Digora Optime storage phosphor plates for proximal subsurface demineralization: effect of different exposure times

Erinç Önem; B. Güniz Baksı; B. Hakan Şen; Ali Mert

OBJECTIVE The aim of this study was to compare the diagnostic accuracy of F-speed film and storage phosphor plate (SPP) exposed with different exposure times for the detection of artificial enamel subsurface demineralization. STUDY DESIGN Standard enamel windows of extracted premolars were exposed to a demineralizing solution. All teeth were radiographed before and after acid application with F-speed films and SPPs. Films were exposed for 0.25 seconds and SPPs were exposed using 4 exposure times. Receiver operating characteristic analysis was used for diagnostic accuracy (A(z)). RESULTS Significant differences were obtained among A(z)s of 0.08- versus 0.12-seconds and 0.10- versus 0.12-second exposed SPPs (P < .05). A(z)s of films were higher than the SPPs exposed with 0.08, 0.10, and 0.12 seconds (P < .05). No difference was found between the A(z)s of the 2 systems when SPPs were exposed for 0.16 seconds (P > .05). CONCLUSIONS Diagnostic accuracy of films and SPPs was not impaired when exposure time was 36% reduced for the latter; however, diagnosis was impaired when reduced 52%.


Journal of Applied Oral Science | 2010

Construction of a copper stepwedge with aluminum equivalent mean gray values

Nesrin Dündar; Pelin Güneri; Erinç Önem; Hayal Boyacioglu

Objectives To produce a copper (Cu) stepwedge with aluminum (Al) equivalent mean gray values (MGV). Material and Methods The thicknesses of Cu steps that were equivalent to those of the Al were formulated using the X-ray attenuation properties of the materials. The Al and fabricated Cu stepwedges were radiographed, but the MGVs of the Cu stepwedge were mismatching to those of the Al. Using a mathematical function to adjust the pixel MGV of Cu stepwedge to those of the Al, new Cu stepwedges were created. In vitro iterations were performed until best approximation to Al was reached. Results The MGV of the Cu stepwedges fabricated by formularization were different than those of Al (p=0.001). Iteration method led to MGV similar to those of the Al stepwedge (p=0.207). Conclusions Construction of a Cu stepwedge according to the basic rules of radiophysic failed to result in a stepwedge with similar radiodensity values to those of Al stepwedge. Further studies may use the formularization method only for prototype Cu wedge production, but consecutive iterations shall be compassed to obtain the best approximation to Al MGV.


Journal of Ege University School of Dentistry | 2017

Characterıstics of Mandibular Incisive canal and Lingual foramen Using Dental Volumetric Tomography (DVT)

Erinç Önem; Elif Şener; Gulcan Coskun Akar; Yelda Pinar; Figen Gövsa Gökmen; Güniz Baksı Şen; Mehmet Asim Ozer

OBJECTIVE: To investigate the presence, location and the dimensions of incisive canal and lingual foramen using dental volumetric tomography (DVT). METHODS: Thirty-one dry human mandibles were exposed using a DVT system. Images were examined for the presence of mandibular incisive canal (MIC) and lingual foramina (LF) including their dimensions and anterior-posterior lengths. In addition; labial and lingual diameters and heights of LF was determined. LF were classified with respect to the mental spine as well. RESULTS: MIC was observed in 58% of the images with mean diameter of 2.79mm while the mean length was 2.88mm. Total of 60 LF were observed in 31 mandibles. Twenty eight (47%) of them were located superior while 32 (53%) were located inferior to the genial spines. Only one canal was observed in 30% of the LFs whereas 50% of LFs had two and 20% had three canals. The mean lingual and labial diameters of the LF canals were 0.68mm and 0.63mm respectively. The mean height was 10.57mm and 9.53mm at the lingual and labial sides. CONCLUSION: The MIC, LF and associated neurovascular bundles may show many variations in number, location and size. Therefore, particular evaluation of these structures for each case is recommended.


Clinical Oral Investigations | 2013

Detection of artificial demineralization bordering different types of laminate veneers using visual inspection and storage phosphor radiography.

Erhan Çömlekoğlu; Erinç Önem; Mine Dündar Çömlekoğlu; B. Güniz Baksı; Ali Mert

ObjectiveThe objective of this study is to compare the diagnostic accuracy of visual inspection (VI) and storage phosphor plate (SPP) radiography for the detection of artificial demineralization bordering different laminate veneers.Materials and methodsTwenty human maxillary canine teeth were prepared. All-ceramic (A) and hybrid ceramic (H) laminate veneers were fabricated and luted. Veneered teeth were covered except for a circular window on the proximal surface bordering restorations. Teeth were kept in acetic acid buffer to create demineralization and imaged with a SPP system. Ten observers evaluated all teeth first visually then with SPP images for the presence/absence of demineralization. Teeth were examined using scanning electron microscopy (SEM) as well. The accuracy was expressed as the area under the ROC curves (Az). Pair-wise comparisons were performed using two-way ANOVA and post hoc t test (p = 0.05). Fleiss kappa (κ) was used for agreement.ResultsSPP radiography was better than the VI for both veneers (p = 0.004). The Azs of two veneers were different for both VI (p < 0.005) and SPP (p < 0.005). SEM evaluation revealed lesions confined to enamel. κ was fair for H, and fair to moderate for A. Agreement was higher for the radiographic evaluation for both veneers.ConclusionEnamel demineralizations bordering hybrid and ceramic laminate veneers can be detected better with SPP radiography than VI and detectability was better for all-ceramic veneers than the hybrid ceramic ones.Clinical relevanceEarly detection of enamel demineralizations bordering laminate veneers would result in time-saving and less-invasive treatment methods; therefore, SPP radiography may be recommended in clinically suspicious cases since it provides better diagnostic accuracy.


Community Dentistry and Oral Epidemiology | 2000

Factors of patient satisfaction/dissatisfaction in a dental faculty outpatient clinic in Turkey

Pelin Gurdal; Hülya Çankaya; Erinç Önem; Semanur Dincer; Tarkan Yilmaz


Surgical and Radiologic Anatomy | 2018

Anatomical landmarks of mandibular interforaminal region related to dental implant placement with 3D CBCT: comparison between edentulous and dental mandibles

Elif Sener; Erinç Önem; Gulcan Coskun Akar; Figen Govsa; Mehmet Asim Ozer; Yelda Pinar; Ali Mert; B. Guniz Baksi Sen


Oral Science International | 2013

Effect of exposure parameters on the radiopacity of root canal sealers

Erinç Önem; B. Güniz Baksı; B. Hakan Şen


Journal of Dental Sciences | 2012

Comparison of imaging characteristics of Digora fmx and Digora Optime storage phosphor plate systems

Erinç Önem; Elif Soğur; B. Güniz Baksı


Current Medical Imaging Reviews | 2017

Effect of Tube Current on Linear Measurement Accuracy of Cone Beam Computed Tomography Images

Elif Sener; Erinç Önem; Ali Mert; B. Baksı

Collaboration


Dive into the Erinç Önem's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge