Ertuğrul Can
Ondokuz Mayıs University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Ertuğrul Can.
Ophthalmic Research | 2017
Ozlem Eski Yucel; Ertuğrul Can; Hilal Eser Öztürk; Hakki Birinci; Yuksel Sullu
Purpose: The aim of this study was to assess the efficacy of a single intravitreal dexamethasone implant (IDI) over 6 months in eyes with chronic diabetic macular edema (DME) that were resistant to intravitreal ranibizumab (IR) treatment. Methods: This retrospective study was conducted at the Ondokuz Mayis University Hospital, Samsun, Turkey. Efficacy outcomes were considered as the change from baseline in best corrected visual acuity (BCVA) and central macular thickness (CMT). Results: Thirty eyes of 20 patients with a mean age of 61.6 ± 8.8 (45-85) years were included in the study. The mean BCVA significantly increased from 0.68 ± 0.27 to 0.56 ± 0.30 logMAR (p = 0.001) and 0.57 ± 0.30 logMAR (p = 0.002) at months 1 and 2, respectively. The proportion of patients who gained 3 or more lines in BCVA was 20%. The mean CMT significantly decreased from 578.93 ± 17.95 µm at baseline to 282.10 ± 21.42, 292.26 ± 19.69, 371.70 ± 21.23, and 463.60 ± 23.16 µm at months 1, 2, 3, and 4, respectively (p = 0.001). Intraocular pressure (IOP) increase occurred in 5 (16.7%) eyes. Cataract surgery was required in 3 (13%) out of 23 phakic eyes. Conclusion: IDI provides significant benefits in visual acuity gains and anatomic improvements in eyes with chronic DME that are resistant to IR treatment. Increases in IOP and cataract progression can be observed in IDI-treated patients. However, its safety profile is acceptable.
Journal of Glaucoma | 2016
Serkan Akkaya; Ertuğrul Can; Faruk Öztürk
Purpose:To evaluate the optic nerve head (ONH) parameters of primary open-angle glaucoma (POAG) patients with and without diabetes and to investigate the effect of the metabolic control of diabetes on ONH topography. Materials and Methods:A study group of 60 eyes of 60 POAG patients with type 2 diabetes mellitus and a control group of 41 eyes of 41 POAG patients without diabetes were recruited for the study. Complete ophthalmic examinations of all patients were performed and the quantitative optic disc parameters were evaluated with Heidelberg retina tomography (HRT) III. HbA1c measurements of diabetic patients were assessed on the same day when the ophthalmic assessments were performed. Results:Mean rim area and rim volume of the study group was statistically higher than the control group (P=0.04 for rim area and P=0.02 for rim volume). The difference in other parameters of the HRT between the groups were insignificant (P>0.05). In the study group, the duration of the diabetes was not significantly correlated to rim area and rim volume (r=0.03, P=0.81 for rim area; r=0.03, P=0.79 for rim volume). Analysis of covariance showed insignificant effects of age, sex, MD, and PSD values over rim area and rim volume (P>0.05). There were weak but statistically significant correlations between HbA1c levels and some HRT parameters including disc area, cup area, cup volume, and cup shape measure (r=0.35 and P=0.006 for disc area; r=0.35 and P=0.006 for cup area; r=0.32 and P=0.01 for cup volume; r=0.32 and P=0.01 for cup shape measure). Conclusions:The results of this study imply the protective effect of diabetes over glaucomatous optic nerve damage in POAG patients. However, larger and controlled studies are warranted to confirm those findings.
Current Eye Research | 2016
Adem Gül; Kerim Aslan; Rifat Karli; Nurşen Aritürk; Ertuğrul Can
Abstract Background: To search the relationships between the primary nasolacrimal duct obstruction and the angle between the bony inferior turbinate and upper part of the medial wall of the maxillary sinus. Design: Retrospective study. Participants and methods: Computed tomography findings of 35 patients with primary nasolacrimal duct obstruction and 100 sides of 50 individuals were reviewed. While the study group was composed of patients who had external dacryocystorhinostomy surgery, the control group was composed of patients who had CT scans due to headache, sinusitis and smell dysfunction. Epiphora complaint was evaluated with the lacrimal syringing. The exclusion criteria were: age less than 20 years, previous nose, sinus, turbinate or lacrimal surgery, prior history of maxillofacial fracture, nasopharyngeal malignancy, reflex hypersecretion, and associated pathology of the lacrimal canaliculi. Main outcome measures: The angle of inferior turbinate. Results: The mean angles were 53.2° (range, 37.9–82.9°) for affected side of the study group, 58.6° (range, 32–85.3°) for the unaffected side of the study group and 56.8° (range, 41.2–76.9°) in the control group. The difference between the angles was statistically significant between the study and the control groups (p < 0.05). The difference between the operated and non-operated sides of the study group was also statistically significant (p < 0.05). Conclusion: Although this study was performed in a small group, we thought that the narrow angle between the bony inferior turbinate and upper part of the medial wall of the maxillary sinus might be a possible causative factor in primary acquired nasolacrimal duct obstructions.
Journal of Craniofacial Surgery | 2015
Adem Gül; Ismail Kucuker; Ertuğrul Can; Leyla Niyaz; Ozlem Eski Yucel
the surgeons understanding of the paranasal sinus anatomy and helpful in performing a more complete anatomic dissection. This helped to reduce intraoperative complications and provide better outcomes. Moreover, we found the navigation platform a valuable teaching tool in the residency training program in our institute. To conclude, the use of intraoperative navigation system is firmly established as a valuable technology in the management of paranasal sinus disease. It may improve the confidence of the surgeon by confirming the position within the challenging anatomic fields. This increases surgical effectiveness and improves surgical safety. The effect of navigation-aided endoscopic surgery on the clinical outcomes is to date not demonstrated.
Arquivos Brasileiros De Oftalmologia | 2015
Adem Gül; Mustafa Duran; Ertuğrul Can; Ozlem Eski Yucel; Yuksel Sullu
PURPOSE To report and compare the surgical, visual, and anatomical outcomes following treatment of dislocated intraocular lenses (IOLs). METHODS The medical records of 28 eyes of 28 patients were evaluated. Age, gender, pre-and postoperative best-corrected visual acuity (BCVA), surgical methods, and complications were recorded. RESULTS Pre-and postoperative BCVA ranged from counting fingers to 20/32 and from counting fingers to 20/25, respectively. Late-onset dislocations were the most frequently observed complication. The most frequent surgical method was IOL repositioning in 15 of 28 patients, followed by IOL exchange in 11 patients, and IOL removal in 2 patients. Only 1 patient required surgical re-intervention with IOL capture. CONCLUSIONS Visual acuity improved following the use of either IOL repositioning or IOL exchange. No superiority of one method over the other was observed. In the present retrospective case series, management of dislocated IOLs with repositioning or exchange of the primary implant conferred comparable surgical and visual outcomes.
Indian Journal of Ophthalmology | 2014
Ertuğrul Can; Resat Basaran; Adem Gül; Hakki Birinci
Aim of Study: With an ab-interno technique of transscleral suturing of current one-piece posterior chamber intraocular lenses (PC IOLs) by injector implantation in the absence of capsular support, we aimed to demonstrate the possibility of the implantation of one-piece acrylic PC IOLs that might be produced in the future for only scleral fixation through small clear corneal incision. Materials and Methods: Case report and literature review. Results: This procedure has been performed in eight aphakic eyes with four different types of IOLs. Good centration was achieved with minimal technical effort. All patients had well-centered and stable lenses postoperatively during 9-18 months follow-up. Conclusion: We managed to decrease the risks of surgical trauma and intricate surgical maneuvers requirement. With this technique, excessive fluid leakage and consecutive hypotony can be minimized.
Türk Oftalmoloji Dergisi | 2016
Muhammed Batur; Adem Gül; Erbil Seven; Ertuğrul Can; Tekin Yasar
Objectives: We aimed to evaluate the development of posterior capsular opacification (PCO) in preschool- and school-age children with cataract who underwent cataract surgery without posterior capsulotomy and anterior vitrectomy. Materials and Methods: The records of 30 eyes of 21 patients who underwent pediatric cataract surgery and intraocular lens (IOL) implantation were retrospectively reviewed. Patients’ age, PCO status and duration, need for neodymium-doped yttrium aluminium garnet (Nd:YAG) laser treatment based on coverage of visual axis, and follow-up period were recorded. Results: The mean age of the patients was 7.6±2.83 (4-12) years. Unilateral cataract surgery and IOL implantation were performed in 12 patients (57.14%) and bilateral cataract surgery and IOL implantation were performed in nine patients (42.86%). Average follow-up time was 17.7±22.67 (3-83) months. PCO developed in 21 eyes (70%) and covered the visual axis in 15 eyes (50%), which therefore required Nd:YAG laser posterior capsulotomy. The mean duration of postoperative PCO development was 8.91±18.7 months (1 week-71 months). Conclusion: We believe that with adequately experienced surgeons, performing both cataract surgery and posterior capsulotomy with anterior vitrectomy in the same session is appropriate for selected preschool- and school-age children with cataract.
Middle East African Journal of Ophthalmology | 2016
Ertuğrul Can; Mustafa Duran; Tuğba Çetinkaya; Nurşen Aritürk
Aims: To evaluate a new noncontact optical biometer using partial-coherence interferometry and to compare the clinical measurements with those obtained from the device using optical low-coherence reflectometry (OLCR). Setting and Design: Ondokuz Mayis University, Samsun, Turkey. Nonrandomized, prospective clinical trial Subjects and Methods: The study was performed on the healthy phakic eyes of volunteers in the year 2014. Measurements of axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), mean keratometry (K), and white-to-white (WTW) measurements obtained with the low-time coherence interferometry (LTCI) were compared with those obtained with the OLCR. Statistical Analysis Used: The results were evaluated using Bland-Altman analyses. The differences between both methods were assessed using the paired t-test, and its correlation was evaluated by Pearson′s coefficient. RESULTS: We examined seventy participants with a mean age of 33.06 (±9.7) (range: 19-53) years. AL measurements with LTCI and OLCR were 23.7 (±1.08) mm and 23.7 (±1.1) mm, respectively. ACD was 3.6 (±0.4) mm and 3.5 (±0.4) mm for LTCI and OLCR, respectively. The mean CCT measurements for both devices were 533 (±28) mm and 522 (±28) mm, respectively. The mean K readings measurements for LTCI and OLCR were 43.3 (±1.5) D and 43.3 (±1.5) D, respectively. The mean WTW distance measurements for both devices were 12.0 (±0.5) mm and 12.1 (±0.5) mm, respectively. Conclusions: Measurements with LTCI correlated well with those with the OLCR. These two devices showed good agreement for the measurement of all parameters.
Journal of Pediatric Ophthalmology & Strabismus | 2016
Leyla Niyaz; Ertuğrul Can; Zeynep Seymen; Bilge Eraydin
PURPOSE To assess the changes of anterior segment parameters with cycloplegia. METHODS A cross-sectional study of healthy pediatric patients was performed. Anterior segment parameters were obtained by the Galilei Dual-Scheimpflug analyzer (Ziemer Group, Port, Switzerland) before and 40 minutes after the instillation of cyclopentolate. The effect of gender was evaluated. RESULTS There were 43 boys and 50 girls with a mean age of 7.76 ± 2.7 years. There was a significant increase in anterior chamber depth, anterior chamber volume, and pupil diameter after the cycloplegia (P < .05). The anterior chamber angle increased after cycloplegia in the nasal, temporal, and inferior quadrants (P < .05), but not in the superior quadrant (P > .05). The mean values of anterior segment parameters were similar in both genders. CONCLUSIONS The values of anterior chamber depth, anterior chamber volume, anterior chamber angle, and pupil diameter measured with the Galilei Dual-Scheimpflug analyzer increased significantly after cycloplegia. Gender did not have an effect on anterior segment parameters. [J Pediatr Ophthalmol Strabismus. 2016;53(4):234-237.].
European Journal of Ophthalmology | 2013
Ertuğrul Can; M. Resat Basaran; Adem Gül
Purpose. We describe an ab interno technique for injector implantation of a one-piece multifocal intraocular lens (IOL). Methods. Transscleral fixation of multifocal posterior chamber IOL implantation using an injector with ab interno technique was performed in an eye of a 9-year-old girl who had undergone pars plana lensectomy 2 years before for bilateral lens subluxation with unknown etiology. Results. No major complications were encountered during a 3-month follow-up of the patient and excellent centration was observed during the follow-up period. Her preoperative best spectacle-corrected distance visual acuity of 20/32 improved to uncorrected distance visual acuity of 20/25. Conclusions. Closed-loop design of IOL served the function of eyelets and position of the IOL was provided using only a 2-point fixation. Intraoperative position adjustment of the IOL provided an excellent centralization of multifocal IOL.