Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Evelyn Regar is active.

Publication


Featured researches published by Evelyn Regar.


The Lancet | 2004

Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy

Eugene McFadden; Eugenio Stabile; Evelyn Regar; Edouard Cheneau; Andrew T.L. Ong; Tim Kinnaird; William O. Suddath; Neil J. Weissman; Rebecca Torguson; Kenneth M. Kent; A.D. Pichard; Lowell F. Satler; Ron Waksman; Patrick W. Serruys

Although the safety profiles of coronary stents eluting sirolimus or paclitaxel do not seem to differ from those of bare metal stents in the short-to-medium term, concern has arisen about the potential for late stent thromboses related to delayed endothelialisation of the stent struts. We report four cases of angiographically-confirmed stent thrombosis that occurred late after elective implantation of polymer-based paxlitaxel-eluting (343 and 442 days) or sirolimus-eluting (335 and 375 days) stents, and resulted in myocardial infarction. All cases arose soon after antiplatelet therapy was interrupted. If confirmed in systematic long-term follow-up studies, our findings have potentially serious clinical implications.


Journal of the American College of Cardiology | 2012

Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation.

Guillermo J. Tearney; Evelyn Regar; Takashi Akasaka; Tom Adriaenssens; Hiram G. Bezerra; Brett E. Bouma; Nico Bruining; Jin-man Cho; Saqib Chowdhary; Marco A. Costa; Ranil de Silva; Jouke Dijkstra; Carlo Di Mario; Darius Dudeck; Erlin Falk; Marc D. Feldman; Peter J. Fitzgerald; Hector Garcia Garcia; Nieves Gonzalo; Juan F. Granada; Giulio Guagliumi; Niels R. Holm; Yasuhiro Honda; Fumiaki Ikeno; Masanori Kawasaki; Janusz Kochman; Lukasz Koltowski; Takashi Kubo; Teruyoshi Kume; Hiroyuki Kyono

OBJECTIVES The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease. BACKGROUND Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of ~10 μm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and the interest in using this technology is growing. Incorporation of IVOCT in research and daily clinical practice can be facilitated by the development of uniform terminology and consensus-based standards on use of the technology, interpretation of the images, and reporting of IVOCT results. METHODS The IWG-IVOCT, comprising more than 260 academic and industry members from Asia, Europe, and the United States, formed in 2008 and convened on the topic of IVOCT standardization through a series of 9 national and international meetings. RESULTS Knowledge and recommendations from this group on key areas within the IVOCT field were assembled to generate this consensus document, authored by the Writing Committee, composed of academicians who have participated in meetings and/or writing of the text. CONCLUSIONS This document may be broadly used as a standard reference regarding the current state of the IVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVOCT data.


The Lancet | 2008

A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial

John A. Ormiston; Patrick W. Serruys; Evelyn Regar; Dariusz Dudek; Leif Thuesen; Mark Webster; Yoshinobu Onuma; Hector M. Garcia-Garcia; Robert McGreevy; Susan Veldhof

BACKGROUND A fully bioabsorbable drug-eluting coronary stent that scaffolds the vessel wall when needed and then disappears once the acute recoil and constrictive remodelling processes have subsided has theoretical advantages. The bioasorbable everolimus-eluting stent (BVS) has a backbone of poly-L-lactic acid that provides the support and a coating of poly-D,L-lactic acid that contains and controls the release of the antiproliferative agent everolimus. We assessed the feasibility and safety of this BVS stent. METHODS In this prospective, open-label study we enrolled 30 patients who had either stable, unstable, or silent ischaemia and a single de-novo lesion that was suitable for treatment with a single 3.0 x 12 mm or 3.0 x 18 mm stent. Patients were enrolled from four academic hospitals in Auckland, Rotterdam, Krakow, and Skejby. The composite endpoint was cardiac death, myocardial infarction, and ischaemia-driven target lesion revascularisation. Angiographic endpoints were available for 26 patients and intravascular-ultrasound endpoints for 24 patients. Clinical endpoints were assessed in all 30 patients at 6 and 12 months. In a subset of 13 patients, optical coherence tomography was undertaken at baseline and follow-up. Analysis was by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00300131. FINDINGS Procedural success was 100% (30/30 patients), and device success 94% (29/31 attempts at implantation of the stent). At 1 year, the rate of major adverse cardiac events was 3.3%, with only one patient having a non-Q wave myocardial infarction and no target lesion revascularisations. No late stent thromboses were recorded. At 6-month follow-up, the angiographic in-stent late loss was 0.44 (0.35) mm and was mainly due to a mild reduction of the stent area (-11.8%) as measured by intravascular ultrasound. The neointimal area was small (0.30 [SD 0.44] mm2), with a minimal area obstruction of 5.5%. INTERPRETATION This study shows the feasibility of implantation of the bioabsorbable everolimus-eluting stent, with an acceptable in-stent late loss, minimal intrastent neointimal hyperplasia, and a low stent area obstruction. FUNDING Abbott Vascular.


European Heart Journal | 2010

Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis

Francesco Prati; Evelyn Regar; Gary S. Mintz; Eloisa Arbustini; Carlo Di Mario; Ik-Kyung Jang; Takashi Akasaka; Marco A. Costa; Giulio Guagliumi; Eberhard Grube; Yukio Ozaki; Fausto J. Pinto; Patrick W. Serruys

Optical coherence tomography (OCT) is a novel intravascular imaging modality, based on infrared light emission, that enables a high resolution arterial wall imaging, in the range of 10-20 microns. This feature of OCT allows the visualization of specific components of the atherosclerotic plaques. The aim of the present Expert Review Document is to address the methodology, terminology and clinical applications of OCT for qualitative and quantitative assessment of coronary arteries and atherosclerosis.


Journal of the American College of Cardiology | 2010

Evaluation of the Second Generation of a Bioresorbable Everolimus Drug-Eluting Vascular Scaffold for Treatment of De Novo Coronary Artery Stenosis Six-Month Clinical and Imaging Outcomes

Patrick W. Serruys; Yoshinobu Onuma; John A. Ormiston; Bernard De Bruyne; Evelyn Regar; Dariusz Dudek; Leif Thuesen; Pieter C. Smits; Bernard Chevalier; Dougal McClean; Jacques J. Koolen; Stephan Windecker; Robert Whitbourn; Ian T. Meredith; Cecile Dorange; Susan Veldhof; Karine Miquel-Hebert; Richard Rapoza; Hector M. Garcia-Garcia

OBJECTIVES The aim of this study was to demonstrate that the prevention of early scaffold area shrinkage of the ABSORB BVS (Rev.1.1, Abbott Vascular, Santa Clara, California) was sustained and not simply delayed by a few months. BACKGROUND With improved scaffold design and modified manufacturing process of its polymer, the second iteration of ABSORB (BVS 1.1) has improved performance to prevent a scaffold area reduction at 6 months. METHODS Fifty-six patients were enrolled and received 57 ABSORB scaffolds. Quantitative coronary angiography, intravascular ultrasound (IVUS), analysis of radiofrequency backscattering, echogenicity and optical coherence tomography (OCT) were performed at baseline and at 12-month follow-up. RESULTS Overall the scaffold area remained unchanged with IVUS as well as with OCT, whereas the radiofrequency backscattering and the echogenicity of the struts decreased by 16.8% (p < 0.001) and 20% (p < 0.001), respectively; more specifically, the strut core area on OCT decreased by 11.4% (p = 0.003). Despite the absence of scaffold area loss, pharmacological vasomotion was restored. On an intention-to-treat basis, the angiographic late lumen loss amounted to 0.27 ± 0.32 mm with an IVUS relative decrease in minimal lumen area of 1.94% (p = 0.12), without significant changes in mean lumen area. The OCT at follow-up showed that 96.69% of the struts were covered and that malapposition, initially observed in 18 scaffolds was only detected at follow-up in 4 scaffolds. Two patients experienced peri-procedural and iatrogenic myocardial infarction, respectively, whereas 2 underwent repeat intervention, resulting in the major adverse cardiac event rate of 7.1% (4 of 56). CONCLUSIONS The 12-month performance of the second-generation ABSORB bioresorbable everolimus-eluting scaffold justifies the conduct of a randomized trial against current best standards. (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System [BVS EECSS] in the Treatment of Patients With de Novo Native Coronary Artery Lesions; NCT00856856).


Circulation | 2003

TAXUS III Trial In-Stent Restenosis Treated With Stent-Based Delivery of Paclitaxel Incorporated in a Slow-Release Polymer Formulation

Kengo Tanabe; Patrick W. Serruys; Eberhard Grube; Pieter C. Smits; Guido Selbach; Willem J. van der Giessen; Manfred Staberock; Pim J. de Feyter; Ralf Müller; Evelyn Regar; Muzaffer Degertekin; Jurgen Ligthart; Clemens Disco; Bianca Backx; Mary E. Russell

Background—The first clinical study of paclitaxel-eluting stent for de novo lesions showed promising results. We performed the TAXUS III trial to evaluate the feasibility and safety of paclitaxel-eluting stent for the treatment of in-stent restenosis (ISR). Methods and Results—The TAXUS III trial was a single-arm, 2-center study that enrolled 28 patients with ISR meeting the criteria of lesion length ≤30 mm, 50% to 99% diameter stenosis, and vessel diameter 3.0 to 3.5 mm. They were treated with one or more TAXUS NIRx paclitaxel-eluting stents. Twenty-five patients completed the angiographic follow-up at 6 months, and 17 of these underwent intravascular ultrasound (IVUS) examination. No subacute stent thrombosis occurred up to 12 months, but there was one late chronic total occlusion, and additional 3 patients showed angiographic restenosis. The mean late loss was 0.54 mm, with neointimal hyperplasia volume of 20.3 mm3. The major adverse cardiac event rate was 29% (8 patients; 1 non-Q-wave myocardial infarction, 1 coronary artery bypass grafting, and 6 target lesion revascularization [TLR]). Of the patients with TLR, 1 had restenosis in a bare stent implanted for edge dissection and 2 had restenosis in a gap between 2 paclitaxel-eluting stents. Two patients without angiographic restenosis underwent TLR as a result of the IVUS assessment at follow-up (1 incomplete apposition and 1 insufficient expansion of the stent). Conclusions—Paclitaxel-eluting stent implantation is considered safe and potentially efficacious in the treatment of ISR. IVUS guidance to ensure good stent deployment with complete coverage of target lesion may reduce reintervention.


Circulation | 2005

Short- and Long-Term Clinical Outcome After Drug-Eluting Stent Implantation for the Percutaneous Treatment of Left Main Coronary Artery Disease Insights From the Rapamycin-Eluting and Taxus Stent Evaluated At Rotterdam Cardiology Hospital Registries (RESEARCH and T-SEARCH)

Marco Valgimigli; Carlos Van Mieghem; Andrew T.L. Ong; Jiro Aoki; Gaston A. Rodriguez Granillo; Eugene McFadden; Arie Pieter Kappetein; Pim J. de Feyter; Pieter C. Smits; Evelyn Regar; Willem J. van der Giessen; George Sianos; Peter de Jaegere; Ron T. van Domburg; Patrick W. Serruys

Background—The impact of drug-eluting stent (DES) implantation on the incidence of major adverse cardiovascular events in patients undergoing percutaneous intervention for left main (LM) coronary disease is largely unknown. Methods and Results—From April 2001 to December 2003, 181 patients underwent percutaneous coronary intervention for LM stenosis at our institution. The first cohort consisted of 86 patients (19 protected LM) treated with bare metal stents (pre-DES group); the second cohort comprised 95 patients (15 protected LM) treated exclusively with DES. The 2 cohorts were well balanced for all baseline characteristics. At a median follow-up of 503 days (range, 331 to 873 days), the cumulative incidence of major adverse cardiovascular events was lower in the DES cohort than in patients in the pre-DES group (24% versus 45%, respectively; hazard ratio [HR], 0.52 [95% CI, 0.31 to 0.88]; P=0.01). Total mortality did not differ between cohorts; however, there were significantly lower rates of both myocardial infarction (4% versus 12%, respectively; HR, 0.22 [95% CI, 0.07 to 0.65]; P=0.006) and target vessel revascularization (6% versus 23%, respectively; HR, 0.26 [95% CI, 0.10 to 0.65]; P=0.004) in the DES group. On multivariate analysis, use of DES, Parsonnet classification, troponin elevation at entry, distal LM location, and reference vessel diameter were independent predictors of major adverse cardiovascular events. Conclusions—When percutaneous coronary intervention is undertaken at LM lesions, routine DES implantation, which reduces the cumulative incidence of myocardial infarction and the need for target vessel revascularization compared with bare metal stents, should currently be the preferred strategy.


American Heart Journal | 2009

Optical coherence tomography patterns of stent restenosis

Nieves Gonzalo; Patrick W. Serruys; Takayuki Okamura; Heleen M.M. van Beusekom; Hector M. Garcia-Garcia; Gijs van Soest; Wim J. van der Giessen; Evelyn Regar

BACKGROUND Stent restenosis is an infrequent but poorly understood clinical problem in the drug-eluting stent era. The aim of the study was to evaluate the morphologic characteristics of stent restenosis by optical coherence tomography (OCT). METHODS Patients (n = 24, 25 vessels) presenting with angiographically documented stent restenosis were included. Quantitative OCT analysis consisted of lumen and stent area measurement and calculation of restenotic tissue area and burden. Qualitative restenotic tissue analysis included assessment of tissue structure, backscattering and symmetry, visible microvessels, lumen shape, and presence of intraluminal material. RESULTS By angiography, restenosis was classified as diffuse, focal, and at the margins in 9, 11, and 5 vessels, respectively. By OCT, restenotic tissue structure was layered in 52%, homogeneous in 28%, and heterogeneous in 20%. The predominant backscatter was high in 72%. Microvessels were visible in 12%. Lumen shape was irregular in 28% and there was intraluminal material in 20%. The mean restenotic tissue symmetry ratio was 0.58 +/- 0.19. Heterogeneous and low scattering restenotic tissue was more frequent in focal (45.5% and 54.5%, respectively) than in diffuse (0 and 11.1%) and margin restenosis (0 and 0%) (P = .005 for heterogeneous, P = .03 for low scattering). Restenosis patients with unstable angina symptoms presented more frequently irregular lumen shape (60 vs 6.7%, P = .007). Stents implanted </=12 months ago had more frequently restenotic tissue with layered appearance (84.6% vs 16.7%, P = .003). CONCLUSIONS We demonstrate the ability of OCT to identify differential patterns of restenotic tissue after stenting. This information could help in understanding the mechanism of stent restenosis.


Journal of the American College of Cardiology | 2003

Sirolimus-eluting stent for treatment of complex in-stent restenosis: the first clinical experience.

Muzaffer Degertekin; Evelyn Regar; Kengo Tanabe; Pieter C. Smits; Willem J. van der Giessen; S.G. Carlier; Pim J. de Feyter; Jeroen Vos; David P. Foley; Jurgen Ligthart; Jeffrey J. Popma; Patrick W. Serruys

OBJECTIVES In this study, we assess the value of sirolimus eluting stent (SES) implantation in patients with complex in-stent restenosis (ISR). BACKGROUND The treatment of ISR remains a therapeutic challenge, since many pharmacological and mechanical approaches have shown disappointing results. The SESs have been reported to be effective in de-novo coronary lesions. METHODS Sixteen patients with severe, recurrent ISR in a native coronary artery (average lesion length 18.4 mm) and objective evidence of ischemia were included. They received one or more 18 mm Bx VELOCITY SESs (Cordis Waterloo, Belgium). Quantitative angiographic and three-dimensional intravascular ultrasound (IVUS) follow-up was performed at four months, and clinical follow-up at nine months. RESULTS The SES implantation (n = 26) was successful in all 16 patients. Four patients had recurrent restenosis following brachytherapy, and three patients had totally occluded vessels preprocedure. At four months follow-up, one patient had died and three patients had angiographic evidence of restenosis (one in-stent and two in-lesion). In-stent late lumen loss averaged 0.21 mm and the volume obstruction of the stent by IVUS was 1.1%. At nine months clinical follow-up, three patients had experienced four major adverse cardiac events (two deaths and one acute myocardial infarction necessitating repeat target vessel angioplasty). CONCLUSIONS The SES implantation in patients with severe ISR lesions effectively prevents neointima formation and recurrent restenosis at four months angiographic follow-up.


Circulation | 2010

Evaluation of the Second Generation of a Bioresorbable Everolimus Drug-Eluting Vascular Scaffold for Treatment of De Novo Coronary Artery StenosisClinical Perspective

Patrick W. Serruys; Yoshinobu Onuma; John Ormiston; Bernard De Bruyne; Evelyn Regar; Dariusz Dudek; Leif Thuesen; Pieter C. Smits; Bernard Chevalier; Dougal McClean; Jacques J. Koolen; Stephan Windecker; Robert Whitbourn; Ian T. Meredith; Cecile Dorange; Susan Veldhof; Karine Miquel-Hebert; Richard Rapoza; Hector M. Garcia-Garcia

Background— The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified. Methods and Results— Quantitative coronary angiography, intravascular ultrasound with analysis of radiofrequency backscattering, and as an optional assessment, optical coherence tomography (OCT) were performed at baseline and at a 6-month follow-up. Forty-five patients successfully received a single bioresorbable everolimus drug-eluting vascular scaffold. One patient had postprocedural release of myocardial enzyme without Q-wave occurrence; 1 patient with OCT-diagnosed disruption of the scaffold caused by excessive postdilatation was treated 1 month later with a metallic drug-eluting stent. At follow-up, 3 patients declined recatheterization, 42 patients had quantitative coronary angiography, 37 had quantitative intravascular ultrasound, and 25 had OCT. Quantitative coronary angiography disclosed 1 edge restenosis (1 of 42; in-segment binary restenosis, 2.4%). At variance with the ultrasonic changes seen with the first generation of bioresorbable everolimus drug-eluting vascular scaffold at 6 months, the backscattering of the polymeric struts did not decrease over time, the scaffold area was reduced by only 2.0% with intravascular ultrasound, and no change was noted with OCT. On an intention-to-treat basis, the late lumen loss amounted to 0.19±0.18 mm with a limited relative decrease in minimal luminal area of 5.4% on intravascular ultrasound. OCT showed at follow-up that 96.8% of the struts were covered and that malapposition of at least 1 strut, initially observed in 12 scaffolds, was detected at follow-up in only 3 scaffolds. Mean neointimal growth measured by OCT between and on top of the polymeric struts equaled 1.25 mm2, or 16.6% of the scaffold area. Conclusion— Modified manufacturing process of the polymer and geometric changes in the polymeric platform have substantially improved the medium-term performance of this new generation of drug-eluting scaffold to become comparable to those of current drug eluting stents. Clinical Trial Registration— URL: http://clinicaltrials.gov. Unique identifier: NCT00856856.

Collaboration


Dive into the Evelyn Regar's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Robert-Jan van Geuns

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jurgen Ligthart

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Felix Zijlstra

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peter de Jaegere

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Yoshinobu Onuma

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Roberto Diletti

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Antonios Karanasos

Erasmus University Rotterdam

View shared research outputs
Researchain Logo
Decentralizing Knowledge