Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ewald Schober is active.

Publication


Featured researches published by Ewald Schober.


Virchows Archiv | 2000

Significant association of strictures and internal fistula formation in Crohn's disease.

Georg Oberhuber; Petra Stangl; Harald Vogelsang; Ewald Schober; Friedrich Herbst; Christoph Gasche

Abstract Intestinal inflammation in Crohn’s disease (CD) may be complicated by the occurrence of strictures and fistulae. The pathogenesis of fistula formation is unknown. We therefore wanted to determine whether mechanical factors might contribute to the development of fistulae. Furthermore, we tried to define the path of internal fistulae through the muscular layer. For this purpose, surgical resection specimens from 42 consecutive patients with CD were prospectively studied. In gross examination the whole bowel was cut into circumferential cross sections 0.3 cm thick. Abnormal areas were histologically examined. Strictures were found in 38 patients (90.5%), and fistulae were observed in 27 (64.3%) patients. In 11 (40.7%) specimens fistulae were found within a stricture, in 15 (55.6%) at the proximal end, and in 1 (3.7%) no stricture was found. In 7 (25.9%) cases with fistulae, herniated mucosa was found within the muscularis propria or the subserosa. In 7 (25.9%) cases a blood vessel was identified near a fistula traversing the muscularis propria. From these findings we conclude that that mechanical factors may contribute to fistula formation. This is further supported by the fact that fistulae appear to traverse the muscular layer along piercing vessels.


American Journal of Roentgenology | 2005

Diagnostic Value of CT Enteroclysis Compared with Conventional Enteroclysis in Patients with Crohn's Disease

Johannes Sailer; Philipp Peloschek; Ewald Schober; Wolfgang Schima; Walter Reinisch; Harald Vogelsang; Patrick Wunderbaldinger; K. Turetschek

OBJECTIVE The objective of our study was to assess the diagnostic value of CT enteroclysis compared with conventional enteroclysis in patients with Crohns disease. SUBJECTS AND METHODS Fifty consecutive patients (26 women, 24 men; mean age, 36.3 years; age range, 18-52 years) with histologically proven Crohns disease underwent CT enteroclysis and conventional enteroclysis (median time interval, 21.7 days) during a symptomatic stage of their disease. Both techniques were compared with regard to diagnostic yield in assessing the presence and extent of disease. Imaging findings were compared with surgery, follow-up examinations, or both. RESULTS CT enteroclysis and conventional enteroclysis were successfully performed in all 50 patients. Crohns disease-associated radiographic changes were found in 44 patients (88%) using CT enteroclysis and in 42 patients (84%) using conventional enteroclysis. Significantly more Crohns disease-associated abnormalities were diagnosed with CT enteroclysis than with enteroclysis (p < 0.01). Minimal inflammatory changes of the mucosa were diagnosed in 44 patients (88%) using CT enteroclysis and in 42 patients (84%) using enteroclysis. Both imaging methods depicted stenotic bowel segments in 34 patients (68%), and prestenotic dilatation was diagnosed in 20 patients (40%) with CT enteroclysis and in 15 (30%) with enteroclysis. Fistulas were found in 18 patients (36%) with CT enteroclysis and in eight (16%) with enteroclysis (p < 0.01). Skip lesions could be seen in 17 (34%) and three patients (6%), respectively (p < 0.01). Conglomeration of bowel loops tumors was diagnosed with CT enteroclysis in 13 patients (26%) and in three patients (6%) using conventional enteroclysis (p < 0.01). Only CT enteroclysis depicted abscesses in eight patients (16%) (p < 0.01). CONCLUSION CT enteroclysis proved to be significantly superior to conventional enteroclysis in depicting Crohns disease-associated intra- and extramural abnormalities. CT enteroclysis is the imaging method of choice and should replace enteroclysis in patients with Crohns disease.


Journal of Computer Assisted Tomography | 2002

Findings at helical CT-enteroclysis in symptomatic patients with crohn disease: correlation with endoscopic and surgical findings.

K. Turetschek; Ewald Schober; Patrick Wunderbaldinger; Christoph Bernhard; Wolfgang Schima; Andreas Puespoek; Harald Vogelsang; Peter Moeschl; Gerhard H. Mostbeck

Purpose The purpose of our study was to assess the diagnostic potential of helical CT–enteroclysis (HCTE) and to correlate our findings to endoscopic and surgical results. Methods Twenty-eight consecutive patients suffering from histologic proven Crohn disease underwent HCTE and endoscopy within 4 weeks. HCTE findings were read by two observers in consensus and compared with endoscopic and surgical results. Results Morphological signs of an acute or recurrent bowel inflammation were found in 25 of 28 (89%) patients. HCTE demonstrated accurately all mural and extramural changes of the inflamed bowel walls. Moreover, in 18 of 25 (72%) patients, HCTE depicted additional pathologic changes such as fistulas, abscesses, and skip lesions, all of which could not be visualized by endoscopy. Conclusion HCTE is an accurate technique to detect mural and extramural abnormalities in patients with Crohn disease. HCTE should be considered as a complementary imaging method to endoscopy, and should be the first imaging method especially when Crohn-associated complications are suspected.


Acta Radiologica | 1997

ASSOCIATION OF MIDOESOPHAGEAL DIVERTICULA WITH OESOPHAGEAL MOTOR DISORDERS Videofluoroscopy and manometry

Wolfgang Schima; Ewald Schober; G. Stacher; P. Franz; K. Uranitsch; Peter Pokieser; E. Wenzl; A. Resch; Christian J. Herold

Purpose: To evaluate the prevalence and clinical significance of associated oesophageal motor disorders in patients with midoesophageal diverticula. Material and Methods: We retrospectively reviewed videofluoroscopic and, if available, manometric studies of 30 patients with midoesophageal diverticula. The type of diverticulum and the presence and nature of oesophageal motor disorders were assessed. Results: Videofluoroscopy showed that 24 patients had 26 pulsion-type diverticula and 6 patients had 7 traction-type diverticula. Oesophageal motor disorders were demonstrated in 21 of the 24 patients with pulsion-type diverticula and in 3 of the 6 with traction-type diverticula. Nineteen patients had nonspecific motor disorders, 5 had achalasia, and 5 had gastrooesophageal reflux or oesophagitis. Conclusion: Midoesophageal diverticula are most often of the pulsion-type and tend to be associated with an oesophageal motor disorder. Motor disorders are predominantly nonspecific, but achalasia may be encountered as well.


European Journal of Radiology | 2012

CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

Helmut Prosch; Alfred Stadler; Matthias Schilling; Sandra Bürklin; Edith Eisenhuber; Ewald Schober; Gerhard H. Mostbeck

BACKGROUND The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. METHODS Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. RESULTS The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p=0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p<0.001). CONCLUSION Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.


American Journal of Roentgenology | 2006

Management of Patients with Small Pulmonary Nodules: A Survey of Radiologists, Pulmonologists, and Thoracic Surgeons

Helmut Prosch; Gertraud Strasser; Elisabeth Oschatz; Ewald Schober; Barbara Schneider; Gerhard H. Mostbeck

OBJECTIVE The objective of our study was to survey recommendations for the management of small pulmonary nodules found on helical CT from radiologists, pulmonologists, and thoracic surgeons. MATERIALS AND METHODS We surveyed 774 radiologists, 623 pulmonologists, and 101 thoracic surgeons. All are members of an associated Austrian scientific society and were asked for their recommendations in 13 hypothetical cases. Statistical analysis was focused on possible differences between medical specialities, residents and fellows, and male and female doctors and on a possible influence of the number of years in training or in medical practice. RESULTS Complete surveys were returned from 91 radiologists, 74 pulmonologists, and 12 thoracic surgeons. The most frequent recommendation from radiologists was follow-up, whereas the most frequent recommendation from pulmonologists and surgeons was biopsy. The most frequently advised CT follow-up period was 3 months. Whereas thoracic surgeons preferred video-assisted thoracoscopy, radiologists and pulmonologists recommended less invasive procedures (bronchoscopy, CT-guided biopsy) to gain a specific diagnosis. CONCLUSION There are significant differences in the management of small pulmonary nodules among radiologists, pulmonologists, and thoracic surgeons. Whereas radiologists tend to recommend short-term follow-up, pulmonologists and thoracic surgeons prefer a more aggressive approach, especially in patients with a higher likelihood of malignancy.


Journal of Computer Assisted Tomography | 2005

Characterization of hepatocellular tumors: value of mangafodipir-enhanced magnetic resonance imaging.

Martina Scharitzer; Wolfgang Schima; Ewald Schober; Peter Reimer; T. Helmberger; N. Holzknecht; Alfred Stadler; Ahmed Ba-Ssalamah; Michael Weber; Friedrich Wrba

Purpose: To assess the value of mangafodipir trisodium-enhanced MR imaging for characterization of hepatocellular lesions. Materials and Methods: Magnetic resonance images of 41 patients with 48 histopathologically proven hepatocellular lesions (20 cases of focal nodular hyperplasia [FNH], 4 adenomas, 15 hepatocellular carcinomas [HCCs], 7 regenerative nodules, and 2 others) were retrospectively studied. Magnetic resonance imaging was performed on a 1.5-T unit (Vision, Siemens, Erlangen, Germany; ACS-NT, Philips, Best, The Netherlands) using T2-weighted, fat-saturation, turbo spin echo imaging and T1-weighted gradient echo imaging before and 20 minutes after infusion of 5 μmol/kg mangafodipir (Amersham Health, Oslo, Norway). Qualitative analysis by 4 blinded independent readers included assessment of unenhanced images and, in a second step, assessment of unenhanced and contrast-enhanced images together. Lesions were classified as benign or malignant using a 5-point scale, and readers made a specific diagnosis. Results: For characterization of hepatocellular lesions, mangafodipir-enhanced imaging was significantly superior to unenhanced imaging (P < 0.05). On receiver operating characteristic analysis, the area under the curve was 0.768 (95% confidence interval: 0.633-0.903) for unenhanced images and 0.866 (95% confidence interval: 0.767-0.966) for evaluation of unenhanced and contrast-enhanced images together (P < 0.05). Analysis of enhancement patterns aided in characterization and classification of tumors. Conclusion: Administration of mangafodipir improves the differentiation between adenoma or HCC and “nonsurgical” lesions (FNH or regenerative nodules). The accuracy for arriving at a specific diagnosis is higher when unenhanced and mangafodipir-enhanced images are considered together than for unenhanced MR images alone.


Inflammatory Bowel Diseases | 2004

Infliximab: lack of efficacy on perforating complications in Crohn's disease.

Wolfgang Miehsler; W. Reinisch; Lili Kazemi-Shirazi; Clemens Dejaco; Gottfried Novacek; Peter Ferenci; Friedrich Herbst; Judith Karner; Bela Teleky; Ewald Schober; Harald Vogelsang

BackgroundInfliximab (Remicade®), a chimeric monoclonal antibody against tumor necrosis factor alpha (TNF-&agr;), has emerged as promising therapeutic option in perianal fistulizing Crohns disease (CD). However, little knowledge exists about its use for the treatment of internal fistulas in CD. We present our experience with infliximab in this situation. MethodsFour patients with CD who had internal fistulas (Case 1: entero-enteral and entero-abdominal; Case 2: entero-enteral; Case 3: entero-enteral and parastomal; Case 4: entero-vesical) were treated with 3 infusions of infliximab (5 mg/kg body weight) with intervals of 2 and 4 weeks. In addition, 3 patients had strictures and 2 patients had perianal fistulas. ResultsAfter the three infusions of infliximab (5 mg/kg body weight), internal fistulas remained unchanged in all patients. The perianal fistulas present in 2 cases were healed. Administration of infliximab was safe and well tolerated in all cases. ConclusionTreatment with 3 infusions of infliximab (5 mg/kg body weight) led to healing of only the perianal fistulas, whereas the internal fistulas were not influenced. We conclude that in these 4 cases, infliximab was well tolerated but not effective for the management of internal fistulas and was no alternative for surgery.


Journal of Hepatology | 1999

Stenosis of the common bile duct due to Ormond's disease: case report and review of the literature.

Clemens Dejaco; Peter Ferenci; Ewald Schober; Klaus Kaserer; Reinhold Függer; Gottfried Novacek; Alfred Gangl

In a 46-year-old man endoscopic retrograde cholangiopancreatography and computed tomography scan showed a stenosis of the common bile duct by a hypodense mass highly suggestive of a Klatskin tumor. Histologic examination of the resected tumor revealed only non-specific inflammatory, fibrotic tissue without any evidence of malignancy. Three months later, the patient presented with hydronephrosis of the left kidney. Computed tomography scan showed a retroperitoneal mass with encasement of the left ureter. A percutaneous nephrostomy was performed and immunosuppressive therapy with prednisolone and azathioprine was initiated. Under this medication, almost complete regression of the pelvic mass and reopening of the ureter were observed within 3 weeks. Eight months later, azathioprine was withdrawn and prednisolone was tapered continuously to a dose less than 10 mg/day. After a follow-up of 2 years, the patient is still well. Although the histologic findings were non-specific, further evaluation of this case suggests that Ormonds disease was responsible for the tumor that had to be resected.


American Journal of Roentgenology | 2005

Detectability of small and flat polyps in MDCT colonography using 2D and 3D imaging tools: results from a phantom study

Thomas Mang; Cornelia Schaefer-Prokop; Andrea B. Maier; Ewald Schober; G. Lechner; Mathias Prokop

OBJECTIVE The objective of this phantom study was to determine the performance of MDCT colonography for the detection of small polyps under ideal imaging conditions and to determine the added value of 3D imaging when used as an adjunct to 2D imaging. MATERIALS AND METHODS Thirty-six polypoid and 39 flat polyps (44 lesions, 2-5 mm; 31 lesions, 6-8 mm) were placed in three explanted segments of a thoroughly cleaned porcine colon (overall length, 4.5 m) that was distended with air and submerged in a water phantom. MDCT data sets with 4 x 1 mm collimation and 6-mm table feed were reconstructed every 0.7 mm with 1.25-mm effective slice width. The data were reviewed by three radiologists using 2D images in all three projections and with 3D volume-rendered images available as an adjunct to the 2D images. RESULTS Additional 3D as a problem-solving tool significantly increased the overall sensitivity (96% vs 90%), decreased the total number of false-positive calls (n = 9 vs n = 5), and increased the diagnostic confidence level (p < 0.03) compared with 2D images alone. Small polyps less than or equal to 5 mm (89% vs 95%, p = 0.004) and flat polyps (82% vs 94%, p = 0.001) especially benefited from 3D. Sensitivity was generally higher for polypoid than for flat polyps (99% vs 94%, p = 0.041). CONCLUSION Under phantom conditions, simulating an ideal clinical setup, MDCT colonography is not limited by spatial resolution and detects polyps less than or equal to 5 mm in size with high sensitivity and specificity. Additional 3D image tools improve diagnostic accuracy and reviewer confidence, especially for the detection of flat and small polyps.

Collaboration


Dive into the Ewald Schober's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alfred Stadler

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Martina Scharitzer

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge