Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by F. Foulon.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1999
Wolfgang Adam; C. Bauer; E. Berdermann; P. Bergonzo; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; E. Grigoriev; G. Hallewell; R. Hall-Wilton; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania
Abstract Diamond radiation sensors produced by chemical vapour deposition are studied for the application as tracking detectors in high luminosity experiments. Sensors with a charge collection distance up to 250 μm have been manufactured. Their radiation hardness has been studied with pions, proton and neutrons up to fluences of 1.9×10 15 π cm −2 , 5×10 15 p cm −2 and 1.35×10 15 n cm −2 , respectively. Diamond micro-strip detectors with 50 μm pitch have been exposed in a high-energy test beam in order to investigate their charge collection properties. The measured spatial resolution using a centre-of-gravity position finding algorithm corresponds to the digital resolution for this strip pitch. First results from a strip tracker with a 2×4 cm 2 surface area are reported as well as the performance of a diamond tracker read out by radiation-hard electronics with 25 ns shaping time. Diamond pixel sensors have been prepared to match the geometries of the recently available read-out chip prototypes for ATLAS and CMS. Beam test results are shown from a diamond detector bump-bonded to an ATLAS prototype read-out. They demonstrate a 98% bump-bonding efficiency and a digital resolution in both dimensions.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000
Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; W. Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; E. Grigoriev; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania
The paper reviews measurements of the radiation tolerance of CVD diamond for irradiation with 24 GeV/c protons, 300 MeV/c pions and 1 MeV neutrons. For proton and neutron irradiation, the measured charge signal spectrum is compared with the spectrum calculated by a model. Irradiation by particles causes radiation damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model shows that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. In addition, we observed after proton irradiation at the charge signal spectrum a decrease of the number of small signals. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal. (11 refs).
nuclear science symposium and medical imaging conference | 1994
F. Foulon; T. Pochet; E. Gheeraert; A. Deneuville
Diamond films produced by microwave plasma enhanced chemical vapor deposition (CVD) technique have been used to fabricate radiation detectors. The polycrystalline diamond films have a measured resistivity of 10/sup 12/ /spl Omega/.cm, a carrier mobility of 280 cm/sup 2//V.s and a carrier lifetime of about 530 ps. The detector response to laser pulses (/spl lambda/=355, 532 and 1064 nm), X-ray flux (15-50 keV) and alpha particles (/sup 241/Am, 5.49 MeV) has been investigated. The response speed of the detector is in the 100 ps range. A sensitivity of about 3/spl times/10/sup -10/A/V.(Gy/s) was measured under a 50 keV X-ray flux. The detector current response to X-ray flux is almost linear. It is also shown that CVD diamond detectors can be used for alpha particle counting. >
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2002
Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D’Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania; J. Kaplon
Abstract The paper gives new results on the radiation tolerance of CVD diamond for irradiation with 300xa0MeV/c pions and 24xa0GeV/c protons. The measured charge signal spectrum is compared at several irradiation levels with the spectrum calculated by a model. Irradiation by particles causes damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model show that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal.
nuclear science symposium and medical imaging conference | 1998
S. Schnetzer; Wolfgang Adam; C. Bauer; E. Berdermann; P. Bergonzo; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; W. Dabrowski; J. DaGraca; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; E. Grigoriev; G. Hallewell; R. Hall-Wilton; S. Han; F. Hartjes; J. Hrubec; D. Husson
Recent progress on developing diamond-based sensors for vertex detection at high luminosity hadron colliders is described. Measurements of the performance of diamond sensors after irradiation to fluences of up to 5/spl times/10/sup 15/ hadrons/cm/sup 2/ are shown. These indicate that diamond sensors will operate at distances as close as 5 cm from the interaction point at the Large Hadron Collider (LHC) for many years at full luminosity without significant degradation in performance. Measurements of the quality of the signals from diamond sensors as well as spatial uniformity are presented. Test beam results on measurements of diamond-based microstrip and pixels devices are described.
Diamond and Related Materials | 2001
M. Krammer; Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania
Abstract CVD diamond material was used to build position-sensitive detectors for single-charged particles to be employed in high-intensity physics experiments. To obtain position information, metal contacts shaped as strips or pixels are applied to the detector surface for one- or two-dimensional coordinate measurement. Strip detectors 2×4 cm2 in size with a strip distance of 50 μm were tested. Pixel detectors of various pixel sizes were bump bonded to electronics chips and investigated. A key issue for the use of these sensors in high intensity experiments is the radiation hardness. Several irradiation experiments were carried out with pions, protons and neutrons exceeding a fluence of 1015 particles/cm2. The paper presents an overview of the results obtained with strip and pixel detectors in high-energy test beams and summarises the irradiation studies.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2002
Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania; J. Kaplon
Abstract CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15 /cm 2 ) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2×10 15 p / cm 2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9×10 15 π / cm 2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000
Wolfgang Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; G. Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D Kania; J. Kaplon
Abstract In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition, we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1998
M. Krammer; Wolfgang Adam; C. Bauer; E. Berdermann; F. Bogani; E. Borchi; M. Bruzzi; C. Colledani; J. Conway; Wladyslaw Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; D. Fish; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; E. Grigoriev; G. Hallewell; R. Hall-Wilton; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D. R. Kania; J. Kaplon
Abstract To continue the exciting research in the field of particle physics new accelerators and experiments are under construction. In some of these experiments, e.g. ATLAS and CMS at the Large Hadron Collider at CERN or HERA-B at DESY, the detectors have to withstand an extreme environment. The detectors must be radiation hard, provide a very fast signal, and be as thin as possible. The properties of CVD diamond allow to fulfill these requirements and make it an ideal material for the detectors close to the interaction region of these experiments, i.e. the vertex detectors or the inner trackers. The RD42 collaboration is developing diamond detectors for these applications. The program of RD42 includes the improvement of the charge collection properties of CVD diamond, the study of the radiation hardness and the development of low-noise radiation hard readout electronics. An overview of the progress achieved during the last years will be given.
In: (pp. pp. 739-743). (2002) | 2002
W. Adam; E. Berdermann; P. Bergonzo; G. Bertuccio; F. Bogani; E. Borchi; A. Brambilla; M. Bruzzi; C. Colledani; J. Conway; P. D'Angelo; W. Dabrowski; P. Delpierre; A. Deneuville; W. Dulinski; B. Van Eijk; A. Fallou; F. Fizzotti; F. Foulon; M. Friedl; K. K. Gan; E. Gheeraert; Gregory David Hallewell; S. Han; F. Hartjes; J. Hrubec; D. Husson; H. Kagan; D. R. Kania; J. Kaplon