Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where F. Vela-Soria is active.

Publication


Featured researches published by F. Vela-Soria.


Talanta | 2011

A new liquid chromatography―tandem mass spectrometry method for determination of parabens in human placental tissue samples

I. Jiménez-Díaz; F. Vela-Soria; A. Zafra-Gómez; A. Navalón; O. Ballesteros; N. Navea; Mariana F. Fernández; Nicolás Olea; J.L. Vílchez

Endocrine disruptors are a group of organic compounds widely used, which are ubiquitous in the environment and in biological samples. The main effect of these compounds is associated with their ability to mimic or block the action of natural hormones in living organisms, including humans. Parabens (esters of p-hydroxybenzoic acid) belong to this group of compounds. In this work, we propose a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to asses the presence of parabens most commonly used in industrial applications (methyl-, ethyl-, propyl- and butyl-paraben) in samples of human placental tissue. The method involves the extraction of the analytes from the samples using ethyl acetate, followed by a clean-up step using centrifugation prior to their quantification by LC-MS/MS using an atmospheric pressure chemical ionization (APCI) interface in the negative mode. Deuterated bisphenol A (BPA-d(16)) was used as surrogate. Found detection limits (LOD) ranged from 0.03 to 0.06 ng g(-1) and quantification limits (LOQ) from 0.1 to 0.2 ng g(-1), while inter- and intra-day variability was under 13.8%. The method was validated using standard addition calibration and a spike recovery assay. Recovery rates for spiked samples ranged from 82% to 108%. This method was satisfactorily applied for the determination of parabens in 50 placental tissue samples collected from women who live in the province of Granada (Spain).


Talanta | 2011

Determination of benzophenones in human placental tissue samples by liquid chromatography-tandem mass spectrometry.

F. Vela-Soria; I. Jiménez-Díaz; R. Rodríguez-Gómez; A. Zafra-Gómez; O. Ballesteros; A. Navalón; J.L. Vílchez; Mariana F. Fernández; Nicolás Olea

Benzophenones (BPs) are a family of compounds widely used to protect the skin and hair from UV irradiation. Despite human exposure to BPs through dermal application of products containing sunscreen agents and the increasing evidence that BPs are able to interfere with endocrine systems, few studies have examined the occurrence of BPs in humans. In this work, we propose a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to determine six BPs, namely, benzophenone-1 (BP-1), benzophenone-2 (BP-2), benzophenone-3 (BP-3), benzophenone-6 (BP-6), benzophenone-8 (BP-8) and 4-hydroxybenzophenone (4-OH-BP) in human placental tissue samples. The method involves an extraction step of the analytes from the samples using ethyl acetate, followed by a clean-up step using centrifugation prior to their quantification by LC-MS/MS using an atmospheric pressure chemical ionization (APCI) interface in the positive mode. Benzophenone-d(10) (BP-d(10)) was used as surrogate. Found detection limits (LOD) ranged from 0.07 to 0.3 ng g(-1) and quantification limits (LOQ) from 0.3 to 1.0 ng g(-1), while inter- and intra-day variability was under 5%. The method was validated using standard addition calibration and a recovery assay. Recovery rates for spiked samples ranged from 98 to 104%. This method was satisfactorily applied for the determination of BPs in 16 placental tissue samples collected from women who live in Granada (Spain).


Talanta | 2014

A multiclass method for the analysis of endocrine disrupting chemicals in human urine samples. Sample treatment by dispersive liquid–liquid microextraction

F. Vela-Soria; O. Ballesteros; A. Zafra-Gómez; L. Ballesteros; A. Navalón

The population is continuously exposed to endocrine disrupting chemicals (EDCs). This has influenced an increase in diseases and syndromes that are more frequent nowadays. Therefore, it is necessary to develop new analytical procedures to evaluate the exposure with the ultimate objective of establishing, in an accurate way, relationships between EDCs and harmful health effects. In the present work, a new method based on a sample treatment by dispersive liquid-liquid microextraction (DLLME) for the extraction of six parabens (methyl-, ethyl-, isopropyl-, propyl-, isobutyl and butylparaben), six benzophenones (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-6, benzophenone-8 and 4-hydroxybenzophenone) and two bisphenols (bisphenol A and bisphenol S) in human urine samples, followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis is proposed. An enzymatic treatment allows determining the total content of the target EDCs. The extraction parameters were accurately optimized using multivariate optimization strategies. Ethylparaben ring-(13)C6 and bisphenol A-d16 were used as surrogates. Found limits of quantification ranging from 0.2 to 0.5 ng mL(-1) and inter-day variability (evaluated as relative standard deviation) ranging from 2.0% to 14.9%. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery rates ranged from 94% to 105%. A good linearity, for concentrations up to 300 ng mL(-1) for parabens and 40 ng mL(-1) for benzophenones and bisphenols, respectively, was obtained. The method was satisfactorily applied for the determination of target compounds in human urine samples from 20 randomly selected individuals.


Analytica Chimica Acta | 2015

Analytical methods for the assessment of endocrine disrupting chemical exposure during human fetal and lactation stages: a review.

I. Jiménez-Díaz; F. Vela-Soria; R. Rodríguez-Gómez; A. Zafra-Gómez; O. Ballesteros; A. Navalón

In the present work, a review of the analytical methods developed in the last 15 years for the determination of endocrine disrupting chemicals (EDCs) in human samples related with children, including placenta, cord blood, amniotic fluid, maternal blood, maternal urine and breast milk, is proposed. Children are highly vulnerable to toxic chemicals in the environment. Among these environmental contaminants to which children are at risk of exposure are EDCs -substances able to alter the normal hormone function of wildlife and humans-. The work focuses mainly on sample preparation and instrumental techniques used for the detection and quantification of the analytes. The sample preparation techniques include, not only liquid-liquid extraction (LLE) and solid-phase extraction (SPE), but also modern microextraction techniques such as extraction with molecular imprinted polymers (MIPs), stir-bar sorptive extraction (SBSE), hollow-fiber liquid-phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME), matrix solid phase dispersion (MSPD) or ultrasound-assisted extraction (UAE), which are becoming alternatives in the analysis of human samples. Most studies focus on minimizing the number of steps and using the lowest solvent amounts in the sample treatment. The usual instrumental techniques employed include liquid chromatography (LC), gas chromatography (GC) mainly coupled to tandem mass spectrometry. Multiresidue methods are being developed for the determination of several families of EDCs with one extraction step and limited sample preparation.


Talanta | 2014

A new method for the determination of benzophenone-UV filters in human serum samples by dispersive liquid-liquid microextraction with liquid chromatography-tandem mass spectrometry.

F. Vela-Soria; O. Ballesteros; A. Zafra-Gómez; L. Ballesteros; A. Navalón

Benzophenone-UV filters (BP-UV filters) are extensively used in cosmetics products to avoid damaging effects of UV radiation. Despite their low toxicity, many research papers indicate that BP-UV filters are weak endocrine disruptors (EDCs). There are clear relationships between BP-UV filters exposure and several health disorders such as carcinogenesis and malformations observed in animals. In the present work, a new sample treatment procedure by dispersive liquid-liquid microextraction (DLLME) is proposed for the extraction of six BPs, namely benzophenone-1 (BP-1), benzophenone-2 (BP-2), benzophenone-3 (BP-3), benzophenone-6 (BP-6), benzophenone-8 (BP-8) and 4-hydroxybenzophenone (4-OH-BP), in human serum samples, followed by ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) analysis. The method involves an enzymatic treatment to quantify the total content (free plus conjugated species) of BP-UV filters in serum. The extraction parameters were accurately optimized using multivariate optimization approach. Benzophenone-d₁₀ (BP-d₁₀) was used as surrogate. Limits of quantification (LOQs) ranged from 0.4 to 0.9 ng mL(-1) and inter-day precision (evaluated as relative standard deviation) ranged from 1.9% to 13.1%. The method was validated using matrix-matched calibration and a recovery assay. Recovery rates for spiked samples ranged from 97% to 106%, and acceptable linearity was obtained up to concentrations of 40 ng mL(-1). The method was applied to the determination of the target compounds in human serum samples from 20 randomly selected anonymous individuals.


Analytical Methods | 2011

A multiclass method for endocrine disrupting chemical residue analysis in human placental tissue samples by UHPLC–MS/MS

F. Vela-Soria; I. Jiménez-Díaz; R. Rodríguez-Gómez; A. Zafra-Gómez; O. Ballesteros; Mariana F. Fernández; Nicolás Olea; A. Navalón

The group of compounds commonly called endocrine-disrupting chemicals covers a wide range of synthetic and natural substances able to alter the normal hormone function of wildlife and humans, consequently causing adverse health effects. Bisphenol A (BPA) and its chlorinated derivatives, benzophenones (BPs) and parabens (PBs), belong to this group of compounds. In this work, we propose a multiclass ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC–MS/MS) method to determine BPA, its four chlorinated derivatives (monochloro-, dichloro-, trichloro- and tetrachloro-bisphenol A), six BPs (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-6, benzophenone-8 and 4-hidroxybenzophenone) and four PBs (methylparaben, ethylparaben, propylparaben and butylparaben) in human placental tissue samples. The method involves an extraction step of the analytes from the samples using ethyl acetate, followed by a clean-up step by centrifugation prior to their quantification by UHPLC–MS/MS using an atmospheric pressure chemical ionization (APCI) interface in the negative mode. Deuterated bisphenol A (BPA-d16) was used as surrogate. The limits of detection (LOD) found ranged from 0.03 to 0.6 ng g−1, the limits of quantification (LOQ) from 0.1 to 1.4 ng g−1, while inter- and intra-day variability was under 8%. The method was validated using matrix-matched calibration standard and a spike recovery assay. Recovery rates for spiked samples ranged from 95% to 106%. This method was satisfactorily applied to the determination of these compounds in 50 placental tissue samples collected from women who live in the province of Granada (Spain).


Journal of Chromatography A | 2014

Simplified matrix solid phase dispersion procedure for the determination of parabens and benzophenone-ultraviolet filters in human placental tissue samples

F. Vela-Soria; I. Rodríguez; O. Ballesteros; A. Zafra-Gómez; L. Ballesteros; R. Cela; A. Navalón

In recent decades, the industrial development has resulted in the appearance of a large amount of new chemicals that are able to produce disorders in the human endocrine system. These substances, so-called endocrine disrupting chemicals (EDCs), include many families of compounds, such as parabens and benzophenone-UV filters. Taking into account the demonstrated biological activity of these compounds, it is necessary to develop new analytical procedures to assess the exposure in order to establish, in an accurate way, relationships between EDCs and harmful health effects in population. In the present work, a new method based on a simplified sample treatment by matrix solid phase dispersion (MSPD) followed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis, is validated for the determination of four parabens (methyl-, ethyl-, propyl- and butylparaben) and six benzophenone-UV filters (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-6, benzophenone-8 and 4-hydroxybenzophenone) in human placental tissue samples. The extraction parameters were accurately optimized using multivariate optimization strategies. Ethylparaben ring-13C6 and benzophenone-d10 were used as surrogates. The found limits of quantification ranged from 0.2 to 0.4 ng g(-1) and inter-day variability (evaluated as relative standard deviation) ranged from 5.4% to 12.8%. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery rates ranged from 96% to 104%. The method was satisfactorily applied for the determination of compounds in human placental tissue samples collected at the moment of delivery from 10 randomly selected women.


Journal of Chromatography A | 2017

Assessment of parabens and ultraviolet filters in human placenta tissue by ultrasound-assisted extraction and ultra-high performance liquid chromatography-tandem mass spectrometry

F. Vela-Soria; M.E. Gallardo-Torres; O. Ballesteros; C. Díaz; J. Pérez; A. Navalón; M.F. Fernández; Nicolás Olea

Increasing concerns have been raised over recent decades about human exposure to Endocrine Disrupting Chemicals (EDCs), especially about their possible effects on embryo, foetus, newborn, and child. Parabens (PBs) and ultraviolet filters (UV-filters) are prevalent EDCs widely used as additives in cosmetics and personal care products (PCPs). The objective of this study was to determine the presence of four PBs and ten UV-filters in placental tissue samples using a novel analytical method based on ultrasound-assisted extraction (UAE) and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Multivariate optimization strategies were used to accurately optimize extraction and clean-up parameters. Limits of quantification ranged from 0.15 to 0.5μgkg-1, and inter-day variability (evaluated as relative standard deviation) ranged from 3.6% to 14%. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery percents ranged from 94.5% to 112%. The method was satisfactorily applied for the determination of the target compounds in human placental tissue samples collected at delivery from 15 randomly selected women. This new analytical procedure can provide information on foetal exposure to compounds, which has been little studied.


Journal of Chromatography A | 2018

QuEChERS and ultra-high performance liquid chromatography–tandem mass spectrometry method for the determination of parabens and ultraviolet filters in human milk samples

F. Vela-Soria; L.M. Iribarne-Durán; V. Mustieles; I. Jiménez-Díaz; M.F. Fernández; Nicolás Olea

Concerns are growing about human exposure to endocrine disrupting chemicals (EDCs), especially during developmental stages. Parabens (PBs) and ultraviolet filters (UVFs) are prevalent EDCs widely used as additives in cosmetics and personal care products (PCPs). The objective of this study was to develop a method to determine four PBs and ten UVFs in human milk using QuEChERS treatment and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Multivariate strategies were applied to optimize experimental parameters. Limits of quantification ranged from 0.1 to 0.2 ng mL-1 and inter-day variability (evaluated as relative standard deviation) from 6% to 13%. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery percentages ranged from 87% to 112%. The method was satisfactorily applied to assess target compounds in human milk samples from 15 donors. This analytical procedure can provide information on newborn exposure to these EDCs.


Analytical and Bioanalytical Chemistry | 2014

UHPLC–MS/MS method for the determination of bisphenol A and its chlorinated derivatives, bisphenol S, parabens, and benzophenones in human urine samples

F. Vela-Soria; O. Ballesteros; A. Zafra-Gómez; L. Ballesteros; A. Navalón

Collaboration


Dive into the F. Vela-Soria's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

I. Rodríguez

University of Santiago de Compostela

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge