Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where F. Xavier Rius is active.

Publication


Featured researches published by F. Xavier Rius.


Analytical Chemistry | 2010

Real-time potentiometric detection of bacteria in complex samples.

Gustavo A. Zelada-Guillén; Suryakant V. Bhosale; Jordi Riu; F. Xavier Rius

Detecting and identifying pathogen bacteria is essential to ensure quality at all stages of the food chain and to diagnose and control microbial infections. Traditional detection methods, including those based on cell culturing, are tedious and time-consuming, and their further application in real samples generally implies more complex pretreatment steps. Even though state-of-the-art techniques for detecting microorganisms enable the quantification of very low concentrations of bacteria, to date it has been difficult to obtain successful results in real samples in a simple, reliable, and rapid manner. In this Article, we demonstrate that the label-free detection and identification of living bacteria in real samples can be carried out in a couple of minutes and in a direct, simple, and selective way at concentration levels as low as 6 colony forming units/mL (CFU) in complex matrices such as milk or 26 CFU/mL in apple juice where the pretreatment step of samples is extremely easy. We chose Escherichia coli ( E. coli ) CECT 675 cells as a model organism as a nonpathogenic surrogate for pathogenic E. coli O157:H7 to test the effectiveness of a potentiometric aptamer-based biosensor. This biosensor uses single-walled carbon nanotubes (SWCNT) as excellent ion-to-electron transducers and covalently immobilized aptamers as biorecognition elements. The selective aptamer-target interaction significantly changes the electrical potential, thus allowing for both interspecies and interstrain selectivity and enabling the direct detection of the target. This technique is therefore a powerful tool for the immediate identification and detection of microorganisms. We demonstrate the highly selective detection of living bacteria with an immediate linear response of up to 10(4) CFU/mL. The biosensor can be easily built and used, is regenerated without difficulty, and can be used at least five times with no loss in the minimum amount of detected bacteria.


Analytical Chemistry | 2012

Paper-Based Ion-Selective Potentiometric Sensors

Marta Novell; Marc Parrilla; Gastón A. Crespo; F. Xavier Rius; Francisco J. Andrade

A new approach to develop ultra low-cost, robust, rugged, and disposable potentiometric sensors is presented. A suspension of carbon nanotubes in a water-surfactant mixture (carbon nanotubes ink) is applied on conventional filter papers to turn them into conductive papers, which are then used as a substrate to build ion-selective electrodes. The electrodes are made by drop casting a membrane on a small circular area of the conductive paper. In this way, the carbon nanotubes act as both electric conductors and ion-to-electron transducers of the potentiometric signal. Electrodes for sensing K(+), NH(4)(+), and pH were built and tested using this approach, and the results were compared with classical solid-state ion selective electrodes using carbon nanotubes as transducers and glassy carbon as a substrate. In all cases, the analytical performance (sensitivity, linear ranges, limits of detection, selectivity, etc.) of these disposable paper electrodes was similar to that obtained for the more conventional type of ion-selective-electrodes. This opens new avenues for very low-cost platforms for generation of chemical information.


Biosensors and Bioelectronics | 2012

Label-free detection of Staphylococcus aureus in skin using real-time potentiometric biosensors based on carbon nanotubes and aptamers

Gustavo A. Zelada-Guillén; José Luis Sebastián-Avila; Pascal Blondeau; Jordi Riu; F. Xavier Rius

In this paper we report the first biosensor that is able to detect Staphylococcus aureus in real-time. A network of single-walled carbon nanotubes (SWCNTs) acts as an ion-to-electron potentiometric transducer and anti-S. aureus aptamers are the recognition element. Carbon nanotubes were functionalized with aptamers using two different approaches: (1) non-covalent adsorption of drop-casted pyrenil-modified aptamers onto the external walls of the SWCNTs; and (2) covalent bond formation between amine-modified aptamers and carboxylic groups previously introduced by oxidation at the ends of the SWCNTs. Both of these approaches yielded functional biosensors but there were large differences in the minimum detectable bacteria concentration and sensitivity values. With covalent functionalization, the minimum concentration detected was 8×10(2)colony-forming units (CFU)/mL and the sensitivity was 0.36 mV/Decade. With the non-covalent approach, the sensitivity was higher (1.52 mV/Decade) but the minimum concentration detected was greatly affected (10(7) CFU/mL). In both cases, potential as a function of Decade of bacteria concentration was linear. Functional biosensors were used to test real samples from freshly excised pig skin, contaminated with the target microorganism, as a surrogate for human skin.


Analytical and Bioanalytical Chemistry | 2011

Nanostructured materials in potentiometry.

Ali Düzgün; Gustavo A. Zelada-Guillén; Gastón A. Crespo; Santiago Macho; Jordi Riu; F. Xavier Rius

Potentiometry is a very simple electrochemical technique with extraordinary analytical capabilities. It is also well known that nanostructured materials display properties which they do not show in the bulk phase. The combination of the two fields of potentiometry and nanomaterials is therefore a promising area of research and development. In this report, we explain the fundamentals of potentiometric devices that incorporate nanostructured materials and we highlight the advantages and drawbacks of combining nanomaterials and potentiometry. The paper provides an overview of the role of nanostructured materials in the two commonest potentiometric sensors: field-effect transistors and ion-selective electrodes. Additionally, we provide a few recent examples of new potentiometric sensors that are based on receptors immobilized directly onto the nanostructured material surface. Moreover, we summarize the use of potentiometry to analyze processes involving nanostructured materials and the prospects that the use of nanopores offer to potentiometry. Finally, we discuss several difficulties that currently hinder developments in the field and some future trends that will extend potentiometry into new analytical areas such as biology and medicine.


Analytical and Bioanalytical Chemistry | 2011

Solid-state reference electrodes based on carbon nanotubes and polyacrylate membranes

F. Xavier Rius-Ruiz; Anna Kisiel; Agata Michalska; Krzystof Maksymiuk; Jordi Riu; F. Xavier Rius

A novel potentiometric solid-state reference electrode containing single-walled carbon nanotubes as the transducer layer between a polyacrylate membrane and the conductor is reported here. Single-walled carbon nanotubes act as an efficient transducer of the constant potentiometric signal originating from the reference membrane containing the Ag/AgCl/Cl− ions system, and they are needed to obtain a stable reference potentiometric signal. Furthermore, we have taken advantage of the light insensitivity of single-walled carbon nanotubes to improve the analytical performance characteristics of previously reported solid-state reference electrodes. Four different polyacrylate polymers have been selected in order to identify the most efficient reservoir for the Ag/AgCl system. Finally, two different arrangements have been assessed: (1) a solid-state reference electrode using photo-polymerised n-butyl acrylate polymer and (2) a thermo-polymerised methyl methacrylate:n-butyl acrylate (1:10) polymer. The sensitivity to various salts, pH and light, as well as time of response and stability, has been tested: the best results were obtained using single-walled carbon nanotubes and photo-polymerised n-butyl acrylate polymer. Water transport plays an important role in the potentiometric performance of acrylate membranes, so a new screening test method has been developed to qualitatively assess the difference in water percolation between the polyacrylic membranes studied. The results presented here open the way for the true miniaturisation of potentiometric systems using the excellent properties of single-walled carbon nanotubes.


Analyst | 2010

Solid-contact potentiometric aptasensor based on aptamer functionalized carbon nanotubes for the direct determination of proteins.

Ali Düzgün; Alicia Maroto; Teresa Mairal; Ciara O'Sullivan; F. Xavier Rius

A facile, solid-contact selective potentiometric aptasensor exploiting a network of single-walled carbon nanotubes (SWCNT) acting as a transducing element is described in this work. The molecular properties of the SWCNT surface have been modified by covalently linking aptamers as biorecognition elements to the carboxylic groups of the SWCNT walls. As a model system to demonstrate the generic application of the approach, a 15-mer thrombin aptamer interacts with thrombin and the affinity interaction gives rise to a direct potentiometric signal that can be easily recorded within 15 s. The dynamic linear range, with a sensitivity of 8.0 mV/log a(Thr) corresponds to the 10(-7)-10(-6) M range of thrombin concentrations, with a limit of detection of 80 nM. The aptasensor displays selectivity against elastase and bovine serum albumin and is easily regenerated by immersion in 2 M NaCl. The aptasensor demonstrates the capacity of direct detection of the recognition event avoiding the use of labels, mediators, or the addition of further reagents or analyte accumulation.


Biosensors and Bioelectronics | 2009

Determination of choline and derivatives with a solid-contact ion-selective electrode based on octaamide cavitand and carbon nanotubes

Jordi Ampurdanés; Gastón A. Crespo; Alicia Maroto; M. Angeles Sarmentero; Pablo Ballester; F. Xavier Rius

A new solid-contact ion-selective electrode has been developed for determining choline and derivatives in aqueous solutions. The backbone of this new potentiometric sensor is the conjunction of the cavitand receptor, as the molecular recognition element, and a network of non-carboxylated single-walled carbon nanotubes, acting as a solid transducer material. The octaamide cavitand, a synthetic receptor that is highly selective for biologically important trimethyl alkylammonium cations such as choline, acetylcholine or carnitine, makes the selective determination of these compounds possible for the first time. The guest-host interaction takes place in the acrylate ion-selective membrane of the solid-contact electrode. The sensor was characterized by electrochemical impedance spectroscopy and environmental scanning electron microscopy. The new electrode displays a nearly Nernstian slope (57.3+/-1.0 mV/decade) and very stable behaviour (DeltaE/Deltat=224 muVh(-1)) throughout the dynamic range (10(-5) to 10(-1)M). The limit of detection of 10(-6.4)M and the high selectivities obtained will enable choline and derivatives to be determined in biological samples. Finally, the stability of the electrical potential of the new solid-contact electrode was examined by performing current-reversal chronopotentiometry and the influence of the interfacial water film was evaluated by the potentiometric water layer test.


Analytical and Bioanalytical Chemistry | 2009

Solid-contact pH-selective electrode using multi-walled carbon nanotubes.

Gastón A. Crespo; Derese Gugsa; Santiago Macho; F. Xavier Rius

Multi-walled carbon nanotubes (MWCNT) are shown to be efficient transducers of the ionic-to-electronic current. This enables the development of a new solid-contact pH-selective electrode that is based on the deposition of a 35-µm thick layer of MWCNT between the acrylic ion-selective membrane and the glassy carbon rod used as the electrical conductor. The ion-selective membrane was prepared by incorporating tridodecylamine as the ionophore, potassium tetrakis[3,5-bis(trifluoromethyl)phenyl]borate as the lipophilic additive in a polymerized methylmethacrylate and an n-butyl acrylate matrix. The potentiometric response shows Nernstian behaviour and a linear dynamic range between 2.89 and 9.90 pH values. The response time for this electrode was less than 10xa0s throughout the whole working range. The electrode shows a high selectivity towards interfering ions. Electrochemical impedance spectroscopy and chronopotentiometry techniques were used to characterise the electrochemical behaviour and the stability of the carbon-nanotube-based ion-selective electrodes.


Analyst | 2010

Determination of calcium ion in sap using carbon nanotube-based ion-selective electrodes

Rafael Hernández; Jordi Riu; F. Xavier Rius

A new reduced-size solid-state electrode using carbon nanotubes as the transducing layer has been developed for the direct determination of Ca(2+) in sap, overcoming problems encountered by commercial ISEs analysing real complex samples. We show that this solid-contact ISE, which can be easily miniaturized, can be used directly in diluted real samples without any other pretreatment. The performance parameters of the new ISE include a Nernstian slope and excellent stability, good coefficients of selectivity, range of linearity (10(-5) to 10(-2.5) M) and limit of detection (10(-6.2) M), thus making it an excellent tool for determining Ca(2+) in a wide range of plant species.


Analytical Chemistry | 2010

Potentiometric Online Detection of Aromatic Hydrocarbons in Aqueous Phase Using Carbon Nanotube-Based Sensors

Alemayehu P. Washe; Santiago Macho; Gastón A. Crespo; F. Xavier Rius

Surfaces made of entangled networks of single-walled carbon nanotubes (SWCNTs) display a strong adsorption affinity for aromatic hydrocarbons. Adsorption of these compounds onto the walls of SWCNTs changes the electrical characteristics of the SWCNT-solution interface. Using these features, we have developed a potentiometric sensor to detect neutral aromatic species. Specifically, we can detect online aromatic hydrocarbons in industrial coolant water. Our chromatographic results confirm the adsorption of toluene onto the walls of carbon nanotubes, and our impedance spectroscopy data show the change in the double layer capacitance of the carbon nanotube-solution interface upon addition of toluene, thus confirming the proposed sensing mechanism. The sensor showed a toluene concentration dependent EMF response that follows the shape of an adsorption isotherm and displayed an immediate response to the presence of toluene with a detection limit of 2.1 ppm. The sensor does not respond to other nonaromatic hydrocarbons that may coexist with aromatic hydrocarbons in water. It shows a qualitative sensitivity and selectivity of 100% and 83%, respectively, which confirms its ability to detect aromatic hydrocarbons in aqueous solutions. The sensor showed an excellent ability to immediately detect the presence of toluene in actual coolant water. Its operational characteristics, including its fast response, low cost, portability, and easy use in online industrial applications, improve those of current chromatographic or spectroscopic techniques.

Collaboration


Dive into the F. Xavier Rius's collaboration.

Top Co-Authors

Avatar

Jordi Riu

Rovira i Virgili University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Pascal Blondeau

Rovira i Virgili University

View shared research outputs
Top Co-Authors

Avatar

Gustavo A. Zelada-Guillén

National Autonomous University of Mexico

View shared research outputs
Top Co-Authors

Avatar

Ali Düzgün

Rovira i Virgili University

View shared research outputs
Top Co-Authors

Avatar

Alicia Maroto

Rovira i Virgili University

View shared research outputs
Top Co-Authors

Avatar

Enrique J. Parra

Rovira i Virgili University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

José M. Pingarrón

Complutense University of Madrid

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge