Fabio D'Angelo
University of Insubria
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Fabio D'Angelo.
Journal of Shoulder and Elbow Surgery | 2010
Luigi Murena; Ettore Vulcano; Fabio D'Angelo; Maria Monti; Paolo Cherubino
BACKGROUND The Oxford Shoulder Score (OSS) is an English-language questionnaire specifically designed to evaluate patients affected by shoulder pain. Although this scoring system has been translated into other languages, an Italian version of it is still not available. The aim of the present study was to translate, culturally adapt, and validate the Italian version of the OSS. MATERIALS AND METHODS We recruited 140 patients with shoulder pain caused by degenerative or inflammatory state or disorder of the shoulder. Patients completed the following questionnaires: Italian OSS, University of California, Los Angeles (UCLA) Shoulder Rating Scale, Constant-Murley shoulder assessment, and the Medical Outcome Study Short-Form 36 Health Survey (MOS SF-36). Internal consistency was tested using Cronbach coefficient alpha. Reproducibility was assessed by asking 110 patients to complete another OSS 48 hours after the first. Correlation between the total results of both tests was determined by the Pearson correlation coefficient. Validity was assessed by calculating the Pearson correlation coefficient between the OSS and the UCLA, Constant-Murley, and SF-36 assessments. RESULTS Cronbach alpha was 0.95. The Pearson correlation coefficient was r=0.97. With respect to validity, there was a significant correlation between the Italian OSS and the individual scores of UCLA, Constant-Murley, and SF-36. DISCUSSION Psychometric properties of the Italian OSS compared well with those reported for the English OSS. As demonstrated by the high values of Cronbach alpha and Pearson correlation coefficients, in accordance with the English version of the OSS, the Italian version proved to be a reliable, valid, and reproducible measure of shoulder pain perception in Italian-speaking patients.
Indian Journal of Orthopaedics | 2008
Fabio D'Angelo; Luigi Murena; G Zatti; P. Cherubino
Background: Dislocation is one of the most common complications of total hip arthroplasty with a reported dislocation rate of 3.2%. Despite increased experience with hip replacement, the overall rate has not yet changed. The aim of this paper is to review the most recent literature published on this topic and indexed in Medline, in order to clarify the main risk factors, and to standardize a treatment protocol of such an important complication of prosthetic surgery. Materials and Methods: Medline database was searched using key words: “hip dislocation”, “hip instability” from 1980-2007. Studies were eligible for review and included if they met the following criteria: (1) publication in English, (2) clinical trials (3) review papers. Results: The risk of first-time dislocation as a function of time after the surgery is not well understood. Most, but not all, series have demonstrated that the risk of dislocation is highest during the first few months after hip arthroplasty; however, first-time late dislocation can also occur many years after the procedure. Several risk factors were described, including the surgical approach, the diameter of the head, impingement, component malposition, insufficient abductor musculature. In addition, there are also many treatment options, such as long-term bracing after closed reduction, component reorientation, capsulorraphy, trochanteric advancement, increasing offset, exchange of the modular head and the polyethylene liner, insertion of constrained liner. Conclusion: Preventing hip dislocation is obviously the best strategy. Surgeons must take into account patient and surgical risk factors. For patients at high risk for dislocation the surgeon should accurately restore leg length and femoral offset; the use of larger femoral heads, posterior transosseous repair of the capsulotendinous envelope if posterior approach is chosen or the use of a lateral approach should be considered. Proper patient education and postoperative care are very important.
Indian Journal of Orthopaedics | 2008
Fabio D'Angelo; Luigi Murena; M Campagnolo; G Zatti; P. Cherubino
Background: Trabecular Metal (TM) is a new highly porous material made of tantalum (Zimmer, Warsaw, Indiana, USA). Its three-dimensional structure is composed of a series of interconnected dodecahedron pores that are on average 550 μm in diameter. This size is considered optimal for bone ingrowth and is similar to trabecular bone. The elastic modulus of TM (3 GPa) is more similar to that of cancellous (0,1-1,5 GPa) or cortical (112-18 GPa) bone and is significantly less similar to that of Titanium (110 GPa) and Co-Cr alloys (220 GPa). These features enable bone apposition and remodeling. The purpose of the present study was to evaluate the histology of the bone-implant interface in a human specimen. Materials and Methods: A highly porous tantalum cup (Zimmer, Warsaw, Indiana, USA) was removed for recurrent dislocations three years after implantation. In order to obtain a slice of the cup, two cuts were made on the centre using an Exakt cutting machine. Then the slice was embedded in a Technovit resin and a Hematoxylin-eosin stain was used to study the bone tissue. Bone ingrowth was calculated using a method based on simple calculations of planar geometry. Results: The histological evaluation of the periprosthetic tissues revealed a typical chronic inflammation with few particles of polyethylene that were birefringent using polarized light. The quantitative evaluation of bone ingrowth revealed that more than 95% of voids were filled with bone. Discussion: In the literature, a lot of studies focused on tantalum were carried on animal model. Up to now little information is available about the histology of the bone-tantalum interface in a human artificial joint. We had an opportunity to remove a well integrated cup hence this study. The histology confirmed the strong relationship between the structure of this material and bone. The morphometric analysis revealed a high percentage of bone ingrowth.
Cases Journal | 2009
Luigi Murena; Fabio D'Angelo; Daniele A. Falvo; Ettore Vulcano
An acromioclavicular joint cyst is an uncommonly reported condition, which seems to result from a massive rotator cuff tear and degenerative osteoarthritis of the acromioclavicular joint. We present the case of an 81-year-old man affected by an acromioclavicular joint cyst, associated to a massive rotator cuff tear, proximal migration of the humeral head and osteoarthritis of the gleno-humeral joint. The mass was 7 × 2.5 cm in size and the overlying skin presented a fistula that drained clear synovial-like fluid. Plain X-ray examination of the left shoulder showed proximal migration of the humeral head migration and osteoarthritis of the gleno-humeral joint, and further MRI evaluation confirmed the clinical diagnosis of a complete rotator cuff tear and observed a large subcutaneous cyst in communication with the degenerative acromioclavicular joint. The patient underwent surgical excision of the cyst and lateral resection of the clavicle to prevent disease recurrence. To the best of our knowledge, this is the first reported case of an acromioclavicular joint cyst complicated by an aseptic fistula resulting from multiple aspirations.
Journal of Medical Case Reports | 2010
Fabio D'Angelo; Daniele Marcolli; Paolo Bulgheroni; Luigi Murena; Terenzio Congiu; P. Cherubino
IntroductionSeveral cases of tibial post breakage are reported in the literature. To the best of our knowledge, only three cases of NexGen knee prosthesis (Zimmer, Warsaw, Indiana, USA) tibial post failure have been reported.Case presentationIn November 1999, a 63-year-old Caucasian woman from Italy with a history of symptomatic left knee osteoarthritis underwent a total knee arthroplasty. In March 2008, while rising from a chair, she felt a sudden pain and instability in her left knee. She reported a fracture of the polyethylene post of the tibial insert. No malposition or malalignment of either the femoral or tibial components were identified. The polyethylene tibial insert was studied under light microscopy and scanning electron microscopy. The fracture was also noted to have occurred without any notable polyethylene wear.ConclusionScanning electron microscopy revealed two different damage patterns that could be explained with a two-stage rupture of our patients polyethylene post. This could have been caused by a non-optimal ligamentous balancing during first implant surgery. Her knee probably developed a varus instability that weakened the post, and then a posterior anterior stress finally broke the polyethylene.
Cases Journal | 2009
Luigi Murena; Ettore Vulcano; Emanuela Salvato; Marco Marano; Fabio D'Angelo; Paolo Cherubino
Iliopsoas haematoma is an uncommon complication that may arise during anticoagulant therapy, especially with heparin and warfarin. Besides determining patient distress secondary to femoral nerve compression, this event may progress to life-threatening complications and require expensive treatments. We describe the case of a 70-year-old healthy man complaining of severe bilateral groin, lumbar and thigh pain, and paralytic ileus after therapy with heparin. The angio-computed tomography scan observed bilateral iliopsoas haematomas. In view of the clinical and radiological scenarios, we ordered a diagnostic and therapeutic angiography of the bleeding vessels by trans-catheter arterial embolization of the fourth right lumbar artery trunk. The treatment proved to be beneficial from a clinical, radiological and laboratory point of view. To the best of our knowledge, this is the first reported case of bilateral iliopsoas haematoma occurring in a male treated with therapeutic levels of heparin alone.
The Open Orthopaedics Journal | 2013
Paolo Cherubino; Marco Puricelli; Fabio D'Angelo
Infection is a frequent cause of failure after joint replacement surgery. The infection rate after total hip arthroplasty (THA) has been reduced to 1-2% in the last years. However, it still represents a challenging problem for the orthopedic surgeon. Difficulty of therapeutic approach, and poor functional outcomes together with length of treatment and overall cost are the main burden of this issue. Even the diagnosis of an infected hip could be challenging although it is the first step of an accurate treatment. At the end, many cases require removing the implants. Afterwards, the treatment strategy varies according to authors with three different procedures: no re-implantation, immediate placement of new implants or a two-stage surgery re-implantation. Based on the most recently systematic review there is no suggestion that one- or two-stage revision methods have different re-infection outcomes. The two-stage implant-exchange protocol remains the gold standard. It is considered as the most efficacious clinical approach for the treatment of periprosthetic infection, especially in patients with sinus tracts, swelling, extended abscess formation in depth and infection of Methicillin Resistant Staphylococcus Aureus (MRSA), and other multidrug-resistant bacteria as reported in recent consensus documents.
Journal of Orthopaedic Surgery and Research | 2008
Fabio D'Angelo; Mauro Molina; Giacomo Riva; Giovanni Zatti; P. Cherubino
IntroductionMany kind of hydroxyapatite-coated cups were used, with favorable results in short term studies; it was supposed that its use could improve osteointegration of the cup, enhancing thus stability and survivorship. The purpose of this study is to analyze the long term behavior of the hemispheric HA coated, Dual Radius Osteonics cup and to discuss the way of failure through the exam of the revised components and of both periacetabular and osteolysis tissue.Materials and MethodsBetween 1994 and 1997, at the Department of Orthopedic Sciences of the Insubria University, using the posterolateral approach, were implanted 276 Dual Radius Osteonics® in 256 patients, with mean age of 63 years.ResultsAt a mean follow-up of 10 years (range 8–12 years), 183 cups in 165 patients, were available for clinical and radiographical evaluation. 22 Cups among the 183 were revised (11%). The cause of revision was aseptic loosening in 17 cases, septic loosening in one case, periprosthetic fracture in another case, osteolysis and polyethylene wear in two cases and, finally, recurrent dislocations in the last one. In the remaining patients, mean HHS increased from a preoperative value of 50,15 to a postoperative value of 92,69. The mean polyethylene wear was 1,25 mm (min. 0,08, max. 3,9 mm), with a mean annual wear of 0,17 mm. The mean acetabular migration on the two axis was 1,6 mm and 1,8 mm. Peri-acetabular osteolysis were recorded in 89% of the implants (163 cases). The cumulative survivorship (revision as endpoint) at the time was 88,9%.ConclusionOur study confirms the bad behavior of this type of cup probably related to the design, to the method of HA fixation. The observations carried out on the revised cup confirm these hypotheses but did not clarify if the third body wear could be a further problem. Another interesting aspect is the high incidence of osteolysis, which are often asymptomatic becoming a problem for the surgeon as the patient refuses the possibility of a revision.
Acta Orthopaedica Scandinavica | 2000
Giovanni Zatti; Fabio D'Angelo; Alberto Giughello
(Shinmei et al. 1995). Shinmei et al. (1995) reported that the mean (SE) and median values of chondrocalcin in joint fluids of osteoarthrosis (94 cases), rheumatoid arthritis (141 cases), and traumatic arthritis (30 cases) groups were 4.9 (4.71), 1.1 (0.1), and 2.1 (2.0) ng/mL, respectively. The mean chondrocalcin value of normal joint fluids drawn by the injection of physiological saline from 15 healthy controls was 0.3 (0.1) ng/mL. Since the degree of cartilage erosion was mild in our case, we conclude that the increased level of chondrocalcin reflected an increased synthesis of type II collagen in synovium caused by synovial chondromatosis. Estimates of chondrocalcin in joint fluid may be useful for diagnosing synovial chondromatosis.
Hip International | 1999
C.C. Castelli; Fabio D'Angelo; M. Molina; A. Ferrario; Paolo Cherubino
The purpose of this study was to evaluate 54 “Conus” uncemented stems both clinically and radiologically. The radiological evaluation was carried out to verify the stability of this rounded cross-section stem in terms of bone ingrowth and axial subsidence. Clinically, 39 hips (72%) were rated excellent, 13 (24%) were rated good, 2 (4%) were rated fair or poor. The average Harris Hip Score increased from 53 before operation to 93 at the time of the last follow-up (average FU 22.5 months). None was reoperated. Radiologically, 13 stems (24%) were judged to have subsided using a method described by Loudon and Charnley (6). Calcar modification, observed in 22 hips (41%), consisted of a slight rounding off of the proximal medial edge at the cut femoral neck. These results encourage the use of this versatile stem which revealed good primary and secondary stability, with good load distribution along the femur.