Fabio Ernesto Rodriguez Corredor
University of Alberta
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Hotspot
Dive into the research topics where Fabio Ernesto Rodriguez Corredor is active.
Publication
Featured researches published by Fabio Ernesto Rodriguez Corredor.
Journal of Fluids Engineering-transactions of The Asme | 2015
Fabio Ernesto Rodriguez Corredor; Majid Bizhani; Ergun Kuru
Fully developed turbulent flow of drag reducing fluids through a horizontal flow loop with concentric annular geometry was investigated using the particle image velocimetry (PIV) technique. Experiments were conducted at solvent Reynolds numbers ranged from 38,700 to 56,400. Axial mean velocity profile was found to be following the universal wall law close to the wall (i.e., y+ 30). The study was also focused on turbulence statistics such as near wall Reynolds stress distribution, axial and radial velocity fluctuations, vorticity and turbulent kinetic energy budget.
ASME 2014 33rd International Conference on Ocean, Offshore and Arctic Engineering | 2014
Fabio Ernesto Rodriguez Corredor; Majid Bizhani; Ergun Kuru
Effective hole cleaning in horizontal and extended reach wells (ERD) often requires use of high circulation rates, which may not be always achievable due to the risk of circulating bottom hole pressure reaching the fracture limit of the rock. Achieving good hole cleaning while keeping the circulating bottom hole pressure within the safe operational window is very often the major engineering challenge. A drag reducing fluid with good hole cleaning ability could be a potential solution in this case.In order to see if it is possible to use a drag reducing fluid and still achieve a good hole cleaning, an experimental program was designed and conducted. The main objective of this experimental study was to compare the hole cleaning performances of water and a drag reducing fluid.The hole cleaning experiments were conducted using a 9m long horizontal flow loop with concentric annular geometry (Outer Pipe ID = 95 mm, Inner Pipe OD = 38 mm, ID/OD ratio = 0.4). The drag reducing additive was a commercially available partially hydrolyzed polyacrylamide (PHPA). Water and two drag reducing fluids with 0.07% V/V and 0.1% V/V PHPA concentrations were used. Critical velocities for the initiation of cuttings movement with rolling, saltation/dunes, and suspension modes were determined and compared when using water and drag reducing fluids as a carrier fluid. Critical velocities for the initiation of cuttings movement were found to be lower with water than that of drag reducing fluid in all transport modes.Copyright
ASME 2013 International Mechanical Engineering Congress and Exposition | 2013
Majid Bizhani; Fabio Ernesto Rodriguez Corredor; Ergun Kuru
Turbulent flow of a Non-Newtonian polymeric fluid through concentric annuli is studied using a 9 m long horizontal flow loop (radius ratio = 0.4). The measurement technique used is Particle Image Velocimetry (PIV). The solvent Reynolds number is found to vary from 47000 to 66400. Pressure drops are measured and used to detect the onset of transition to turbulence. Measured velocity profiles are found to agree with the universal law of the wall for y + < 11. In the logarithmic region, however, velocity profiles deviate from log law, in a manner consistent with the flow of Newtonian fluids. Reynolds stress is found to be reduced significantly compared to water. The polymer is found to contribute significantly to the total stress close to the solid walls. The radii of maximum velocity are found to be biased toward the inner wall. Results of the turbulence intensity analysis show a slight increase of axial intensities in the buffer layer and especially around the outer wall of the annuli for polymer solutions. Radial velocity fluctuations are suppressed by means of polymer solution. The Root Mean Square (RMS) of vorticity fluctuation in the axial direction is also analyzed revealing a significant reduction of vortical activities as polymer is added to the flow.
ASME 2013 International Mechanical Engineering Congress and Exposition | 2013
Fabio Ernesto Rodriguez Corredor; Majid Bizhani; Ergun Kuru
The effect of drag reducing additive on the structure of turbulence in concentric annular pipe flow was investigated using Particle Image Velocimetry (PIV) technique. Experiments were conducted using a 9m long horizontal flow loop with concentric annular geometry (inner to outer pipe radius ratio = 0.4). The drag reducing additive was a commercially available partially hydrolyzed polyacrylamide (PHPA). The experiments were conducted using 0.1% V/V polymer concentration, giving a drag reduction of 26% at a solvent Reynolds number equal to 56400.Near wall local fluctuating velocity values were determined by analysing the PIV data. The root mean square (RMS) values of radial velocity fluctuations showed a significant decrease with the use of drag reducing additive. The RMS values of axial velocity fluctuations near the wall (Y+<10) were similar for both water and polymer fluid flow; though, higher peaks were obtained during the polymer fluid flow.As compared to water flow, a strong reduction in vorticity was observed during polymer fluid flow. The degree of vorticity reduction on the inner wall was higher than that of the outer wall.Results of the viscous dissipation and the shear production terms in the kinetic energy budget showed that less energy was produced and dissipated by the route of turbulence when using polymer fluid.Copyright
ASME 2013 International Mechanical Engineering Congress and Exposition | 2013
Aziz Rahman; Fabio Ernesto Rodriguez Corredor; Majid Bizhani; Ergun Kuru
A CFD simulation was conducted to analyze the near wall turbulence characteristics of a drag reducing (DR) polymer fluid (0.12% V/V) flow through concentric annulus. The continuity and momentum equations were solved by using a commercial CFD package (CFX 14) with the Shear-Stress-Transport (SST) model option. The simulation results were compared to the experimental data obtained by using high resolution Particle Image Velocimetry (PIV) analyses of drag reducing polymer fluid flow in a horizontal concentric annulus. A fully developed turbulent flow of water through a horizontal flow loop (ID = 9.5 cm) with concentric annular geometry (inner to outer pipe radius ratio = 0.4) was used for comparison purpose. The flow rates ranged from 3.92 to 5.95 kg/s. Drag reducing PHPA solutions behaved as a power law fluid with the rheological model (μ = Kγn−1) for the shear rate of 1/s to 600/s.Bulk and near wall velocity profile obtained from simulation showed good agreements with the experimental data. Drag reducing polymer reduce the Reynolds stresses level due to weaker and fewer turbulent eddies formation near the wall. Results of the simulation study also showed that if the flow rates of power law fluid increased from 3.92 to 5.95 kg/s, the drag reduction in the annuli is increased from 10% to 20% compared to water case indicating the strong damping to turbulent kinetic energy in the flow. The CFD analyses using SST model is computationally inexpensive and, therefore, can be conveniently used for investigating the flow characteristics of drag reducing polymer fluids in concentric annulus.Copyright
ASME 2013 32nd International Conference on Ocean, Offshore and Arctic Engineering | 2013
Fabio Ernesto Rodriguez Corredor; Majid Bizhani; Ergun Kuru
Polymer drag reduction is investigated using the Particle Image Velocimetry (PIV) technique in fully developed turbulent flow through a horizontal flow loop with concentric annular geometry (inner to outer pipe radius ratio = 0.4). The polymer used was a commercially available partially hydrolyzed polyacrylamide (PHPA). The polymer concentration was varied from 0.07 to 0.12% V/V. The drag reduction is enhanced by increasing polymer concentration until the concentration reaches an optimum value. After that, the drag reduction is decreased with the increasing polymer concentration. Optimum concentration value of PHPA was found to be around 0.1% V/V. Experiments were conducted at solvent Reynolds numbers of 38700, 46700 and 56400. The percent drag reduction was found to be increasing with the increasing Reynolds number.The study was also focused on analyzing the mean flow and turbulence statistics for fully-turbulent flow using the velocity measurements acquired by PIV. Axial mean velocity profile was found to be following the universal wall law close to the wall (i.e., y+ 30). In all cases of polymer application, the viscous sublayer (i.e., y+ <10) thickness was found to be higher than that of the water flow. Reynolds shear stress in the core flow region was found to be decreasing with the increase in polymer concentration.Copyright
ASME 2013 32nd International Conference on Ocean, Offshore and Arctic Engineering | 2013
Aziz Rahman; Fabio Ernesto Rodriguez Corredor; Majid Bizhani; Ergun Kuru
A CFD simulation study was conducted to analyse the near wall turbulence characteristics of water flow through concentric annulus. The continuity and momentum equations were solved by using a commercial CFD package (CFX 14) with the Shear-Stress-Transport (SST) model option. The simulation results were compared to the experimental data obtained by using high resolution Particle Image Velocimetry (PIV) analyses of water flow in a horizontal concentric annulus. A fully developed turbulent flow of water through a horizontal flow loop (ID = 9.5 cm) with concentric annular geometry (inner to outer pipe radius ratio = 0.4) was used for comparison purpose. Reynolds number ranged from 17,500 to 68,500.Annular velocity profile obtained from simulation study showed good agreement with the experimental data. Near wall velocity profile obtained from CFD simulation followed the universal wall law (u+ = y+) up to y+ = 11. CFD analyses using the SST model resulted a good number of velocity data up to y+ = 11, which is normally a very difficult task to achieve experimentally.The CFD analyses using SST model is computationally inexpensive and therefore, can be conveniently used for investigating the near wall turbulent characteristics of flow in concentric annulus.Copyright
ASME 2012 International Mechanical Engineering Congress and Exposition | 2012
Fabio Ernesto Rodriguez Corredor; Majid Bizhani; Mohammad Ashrafuzzaman; Ergun Kuru
Fully developed turbulent flow in a concentric annulus is encountered in many engineering problems including food, chemical as well as oil industry applications. Because of nonlinear radial variation of total shear stress with the distance from the pipe wall, the analysis for the flow in annulus is more complex than in a round tube or parallel plate channel.In this study, fully developed turbulent flow of water through a horizontal flow loop with concentric annular geometry (inner to outer pipe radius ratio = 0.4) was investigated. Reynolds number range varied from 17,700 to 66,900.Velocity near the wall region was measured using high resolution particle image velocimetry (PIV) system. Axial mean velocity profile was found to be following the universal wall law (i.e., u+ = y+) close to the wall (for y+ 10).For all the cases investigated, radial positions of the maximum velocity and zero shear stress were very close to each other (± 0.5 mm). The difference between the both locations were found to be varying from 1.3 to 3.3% ( 2% on the average).Copyright
Spe Drilling & Completion | 2016
Majid Bizhani; Fabio Ernesto Rodriguez Corredor; Ergun Kuru
Flow Turbulence and Combustion | 2015
Majid Bizhani; Fabio Ernesto Rodriguez Corredor; Ergun Kuru