Fabrice Merenda
École Polytechnique Fédérale de Lausanne
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Fabrice Merenda.
Optics Express | 2007
Fabrice Merenda; Johann Rohner; Jean-Marc Fournier; Rene-Paul Salathe
An array of high numerical aperture parabolic micromirrors (NA = 0.96) is used to generate multiple optical tweezers and to trap micron-sized dielectric particles in three dimensions within a fluidic device. The array of micromirrors allows generating arbitrarily large numbers of 3D traps, since the whole trapping area is not restricted by the field-of-view of the high-NA microscope objectives used in traditional tweezers arrangements. Trapping efficiencies of Q(max) r approximately = 0.22, comparable to those of conventional tweezers, have been measured. Moreover, individual fluorescence light from all the trapped particles can be collected simultaneously with the high-NA of the micromirrors. This is demonstrated experimentally by capturing more than 100 fluorescent micro-beads in a fluidic environment. Micromirrors may easily be integrated in microfluidic devices, offering a simple and very efficient solution for miniaturized optical traps in lab-on-a-chip devices.
Optics Express | 2006
Fabrice Merenda; Gerben Boer; Johann Rohner; Guy P. Delacretaz; Rene-Paul Salathe
We have studied the transverse and axial equilibrium positions of dielectric micro-spheres trapped in a single-beam gradient optical trap and exposed to an increasing fluid flow transverse to the trapping beam axis. It is demonstrated that the axial equilibrium position of a trapped micro-sphere is a function of its transverse position in the trapping beam. Moreover, although the applied drag-force acts perpendicularly to the beam axis, reaching a certain distance r(0) from the beam axis (r(0)/a approximately 0.6, a being the sphere radius) the particle escapes the trap due to a breaking axial equilibrium before the actual maximum transverse trapping force is reached. The comparison between a theoretical model and the measurements shows that neglecting these axial equilibrium considerations leads to a theoretical overestimation in the maximal optical transverse trapping forces of up to 50%.
Proceedings of SPIE | 2006
Johann Rohner; Jean-Marc Fournier; Pierre Jacquot; Fabrice Merenda; René Paul Salathé
In biological investigations, many protocols using optical trapping call for the possibility to trap a large number of particles simultaneously. Interference fringes provide a solution for massively parallel micro-manipulation of mesoscopic objects. Concurrently, the strength of traps can be improved by raising the slope of fringe profiles, such as to create intensity gradients much higher than the ones formed by sinusoidal fringes (Youngs fringes). We use a multiple-beam interference system, derived from the classical Fizeau configuration, with semitransparent interfaces to generate walls of light with a very high intensity gradient (Tolansky fringes). These fringes are formed into a trapping set-up to produce new types of trapping templates. The possibility to build multiple trap arrays of various geometries is examined; a high number of particles can be trapped in those potential wells. The period of the fringes can easily be changed in order to fit traps sizes to the dimensions of the confined objects. This is achieved by modifying several parameters of the interferometer, such as the angle and/or the distance between the beam-splitter and the mirror. It is well known that optical trapping presents a great potential when used in conjunction with microfluidics for lab-on-a-chip applications. We present an original solution for multiple trapping integrated in a microfluidic device. This solution does not require high numerical aperture objectives.
Optics Express | 2013
Jongki Kim; Sungrae Lee; Yoonseob Jeong; Junki Kim; Yongmin Jung; Fabrice Merenda; Rene-Paul Salathe; Jeon-Soo Shin; Kyunghwan Oh
Due to its unique non-diffracting and self-reconstructing nature, Bessel beams have been successfully adopted to trap multiple particles along the beams axial direction. However, prior bulk-optic based Bessel beams have a fundamental form-factor limitation for in situ, in-vitro, and in-vivo applications. Here we present a novel implementation of Fourier optics along a single strand of hybrid optical fiber in a monolithic manner that can generate pseudo Bessel beam arrays in two-dimensional space. We successfully demonstrate unique optofluidic transport of the trapped dielectric particles along a curvilinear optical route by multiplexing the fiber optic pseudo Bessel beams. The proposed technique can form a new building block to realize reconfigurable optofluidic transportation of particulates that can break the limitations of both prior bulk-optic Bessel beam generation techniques and conventional microfluidic channels.
Optics Letters | 2009
Fabrice Merenda; Mathieu Grossenbacher; Sylvia Jeney; László Forró; Rene-Paul Salathe
The three-dimensional trap stiffness of optical tweezers formed with high-NA micromirrors is investigated by back-focal-plane interferometry and power spectrum analysis. Normalized stiffness values of kappaxy/Ptrap=1.2(microN/m)/mW and kappaz/Ptrap=0.52(microN/m)/mW in the transverse and axial directions, respectively, have been measured for polystyrene spheres with a radius of 1.03 microm. Compared with high-NA microscope objectives, micromirrors achieve much better trapping performances, particularly in the axial direction.
Journal of Biomechanics | 2008
Philippe Reymond; Fabrice Merenda; Fabienne Perren; Daniel A. Rüfenacht; Nikos Stergiopulos
Keywords: Flow Reference EPFL-CONF-160070View record in Web of Science Record created on 2010-11-30, modified on 2017-05-10
Proceedings of SPIE, the International Society for Optical Engineering | 2008
J.-M. Fournier; Fabrice Merenda; Johann Rohner; Pierre Jacquot; Rene-Paul Salathe
Many types of optical tweezers arrays have been proposed and developed for use in conjunction with microfluidics for bio-chemical essays. Trap arrays rely on different methods allowing various degrees of flexibility and relative trapping efficiencies. Among the different techniques currently employed, it is not simple to distinguish which ones produce adequate performances for a given task in bio-chemistry. Experimental results for trapping efficiently diverse biological specimens allow distinguishing between the properties of optical trap arrays based on techniques as different as interferometry, holography, Fresnel or Fraunhoffer diffraction of diffractive structures, generalized phase contrast, microlens assemblies, micro-mirrors matrices, and also clusters of individual tweezers. The bulkiness of those systems is another important factor in the design of labs-on-a-chip; in particular the use of cumbersome microscope objectives can be detrimental to chip optimization. Arrangements of tweezers produced with different concepts should be compared in terms of efficiency, ease of use, and number of traps simultaneously exploitable
Proceedings of SPIE, the International Society for Optical Engineering | 2007
Fabrice Merenda; Johann Rohner; Elodie Lamothe; Pedro Pascoal; Jean-Marc Fournier; Rene-Paul Salathe
Micro-optical components offer several possibilities for creating large matrices of optical traps, either when working on inverted microscopes, or by directly integrating miniaturized optical components at the level of a micro-fluidic chip. In this article we focus on two particular configurations, both allowing to generate large arrays of 3D optical traps. The first configuration takes advantage of an array of refractive microlenses to generate multiple optical tweezers within the focal plane of a high-NA microscope objective. The second configuration relies on an array of focusing high-NA micromirrors which are directly integrated at the level of a micro-fluidic chip. We also present measurements of the maximal optical trapping forces that can be reached with several types of cells commonly employed in biology and biotechnology, and demonstrate that these forces are essentially related to the bulk refractive index of the cells.
Proceeding Of The Asme Summer Bioengineering Conference - 2007 | 2007
Philippe Reymond; Fabrice Merenda; Fabienne Perren; Daniel Ruefenacht; Nikos Stergiopulos
Keywords: Computer-Simulation ; Stenoses Reference EPFL-CONF-179796View record in Web of Science Record created on 2012-07-04, modified on 2017-05-10
American Journal of Physiology-heart and Circulatory Physiology | 2009
Philippe Reymond; Fabrice Merenda; Fabienne Perren; Daniel A. Rüfenacht; Nikos Stergiopulos