Diabetes Care | 2014

Safety of Outpatient Closed-Loop Control: First Randomized Crossover Trials of a Wearable Artificial Pancreas

Boris P. Kovatchev; Eric Renard; Claudio Cobelli; Howard Zisser; Patrick Keith-Hynes; Stacey M. Anderson; Sue A. Brown; Daniel Chernavvsky; Marc D. Breton; Lloyd B. Mize; Anne Farret; Jerome Place; Daniela Bruttomesso; Simone Del Favero; Federico Boscari; Silvia Galasso; Angelo Avogaro; Lalo Magni; Federico Di Palma; Chiara Toffanin; Mirko Messori; Eyal Dassau; Francis J. Doyle

OBJECTIVE We estimate the effect size of hypoglycemia risk reduction on closed-loop control (CLC) versus open-loop (OL) sensor-augmented insulin pump therapy in supervised outpatient setting. RESEARCH DESIGN AND METHODS Twenty patients with type 1 diabetes initiated the study at the Universities of Virginia, Padova, and Montpellier and Sansum Diabetes Research Institute; 18 completed the entire protocol. Each patient participated in two 40-h outpatient sessions, CLC versus OL, in randomized order. Sensor (Dexcom G4) and insulin pump (Tandem t:slim) were connected to Diabetes Assistant (DiAs)—a smartphone artificial pancreas platform. The patient operated the system through the DiAs user interface during both CLC and OL; study personnel supervised on site and monitored DiAs remotely. There were no dietary restrictions; 45-min walks in town and restaurant dinners were included in both CLC and OL; alcohol was permitted. RESULTS The primary outcome—reduction in risk for hypoglycemia as measured by the low blood glucose (BG) index (LGBI)—resulted in an effect size of 0.64, P = 0.003, with a twofold reduction of hypoglycemia requiring carbohydrate treatment: 1.2 vs. 2.4 episodes/session on CLC versus OL (P = 0.02). This was accompanied by a slight decrease in percentage of time in the target range of 3.9–10 mmol/L (66.1 vs. 70.7%) and increase in mean BG (8.9 vs. 8.4 mmol/L; P = 0.04) on CLC versus OL. CONCLUSIONS CLC running on a smartphone (DiAs) in outpatient conditions reduced hypoglycemia and hypoglycemia treatments when compared with sensor-augmented pump therapy. This was accompanied by marginal increase in average glycemia resulting from a possible overemphasis on hypoglycemia safety.


The Lancet Diabetes & Endocrinology | 2015

2 month evening and night closed-loop glucose control in patients with type 1 diabetes under free-living conditions: a randomised crossover trial

Jort Kropff; Simone Del Favero; Jerome Place; Chiara Toffanin; Roberto Visentin; Marco Monaro; Mirko Messori; Federico Di Palma; Giordano Lanzola; Anne Farret; Federico Boscari; Silvia Galasso; Paolo Magni; Angelo Avogaro; Patrick Keith-Hynes; Boris P. Kovatchev; Daniela Bruttomesso; Claudio Cobelli; J. Hans DeVries; Eric Renard; Lalo Magni

BACKGROUND An artificial pancreas (AP) that can be worn at home from dinner to waking up in the morning might be safe and efficient for first routine use in patients with type 1 diabetes. We assessed the effect on glucose control with use of an AP during the evening and night plus patient-managed sensor-augmented pump therapy (SAP) during the day, versus 24 h use of patient-managed SAP only, in free-living conditions. METHODS In a crossover study done in medical centres in France, Italy, and the Netherlands, patients aged 18-69 years with type 1 diabetes who used insulin pumps for continuous subcutaneous insulin infusion were randomly assigned to 2 months of AP use from dinner to waking up plus SAP use during the day versus 2 months of SAP use only under free-living conditions. Randomisation was achieved with a computer-generated allocation sequence with random block sizes of two, four, or six, masked to the investigator. Patients and investigators were not masked to the type of intervention. The AP consisted of a continuous glucose monitor (CGM) and insulin pump connected to a modified smartphone with a model predictive control algorithm. The primary endpoint was the percentage of time spent in the target glucose concentration range (3·9-10·0 mmol/L) from 2000 to 0800 h. CGM data for weeks 3-8 of the interventions were analysed on a modified intention-to-treat basis including patients who completed at least 6 weeks of each intervention period. The 2 month study period also allowed us to asses HbA1c as one of the secondary outcomes. This trial is registered with ClinicalTrials.gov, number NCT02153190. FINDINGS During 2000-0800 h, the mean time spent in the target range was higher with AP than with SAP use: 66·7% versus 58·1% (paired difference 8·6% [95% CI 5·8 to 11·4], p<0·0001), through a reduction in both mean time spent in hyperglycaemia (glucose concentration >10·0 mmol/L; 31·6% vs 38·5%; -6·9% [-9·8% to -3·9], p<0·0001) and in hypoglycaemia (glucose concentration <3·9 mmol/L; 1·7% vs 3·0%; -1·6% [-2·3 to -1·0], p<0·0001). Decrease in mean HbA1c during the AP period was significantly greater than during the control period (-0·3% vs -0·2%; paired difference -0·2 [95% CI -0·4 to -0·0], p=0·047), taking a period effect into account (p=0·0034). No serious adverse events occurred during this study, and none of the mild-to-moderate adverse events was related to the study intervention. INTERPRETATION Our results support the use of AP at home as a safe and beneficial option for patients with type 1 diabetes. The HbA1c results are encouraging but preliminary. FUNDING European Commission.


Diabetes, Obesity and Metabolism | 2015

Accuracy of two continuous glucose monitoring systems: a head-to-head comparison under clinical research centre and daily life conditions

Jort Kropff; Daniela Bruttomesso; W. Doll; Anne Farret; Silvia Galasso; Yoeri M. Luijf; Julia K. Mader; Jerome Place; Federico Boscari; Thomas R. Pieber; Eric Renard; J. H. DeVries

To assess the accuracy and reliability of the two most widely used continuous glucose monitoring (CGM) systems.


Diabetes, Obesity and Metabolism | 2015

Multicenter outpatient dinner/overnight reduction of hypoglycemia and increased time of glucose in target with a wearable artificial pancreas using modular model predictive control in adults with type 1 diabetes.

S. Del Favero; Jerome Place; Jort Kropff; Mirko Messori; Patrick Keith-Hynes; Roberto Visentin; Marco Monaro; Silvia Galasso; Federico Boscari; Chiara Toffanin; F. Di Palma; Giordano Lanzola; Stefania Scarpellini; Anne Farret; Boris P. Kovatchev; Angelo Avogaro; Daniela Bruttomesso; Lalo Magni; J. H. DeVries; Claudio Cobelli; Eric Renard

To test in an outpatient setting the safety and efficacy of continuous subcutaneous insulin infusion (CSII) driven by a modular model predictive control (MMPC) algorithm informed by continuous glucose monitoring (CGM) measurement.


Diabetes Care | 2016

Multinational Home Use of Closed-Loop Control Is Safe and Effective

Stacey M. Anderson; Dan Raghinaru; Jordan E. Pinsker; Federico Boscari; Eric Renard; Bruce Buckingham; Revital Nimri; Francis J. Doyle; Sue A. Brown; Patrick Keith-Hynes; Marc D. Breton; Daniel Chernavvsky; Wendy C. Bevier; Paige K. Bradley; Daniela Bruttomesso; Simone Del Favero; Roberta Calore; Claudio Cobelli; Angelo Avogaro; Anne Farret; Jerome Place; Trang T. Ly; Satya Shanmugham; Moshe Phillip; Eyal Dassau; Isuru Dasanayake; Craig Kollman; John Lum; Roy W. Beck; Boris P. Kovatchev

OBJECTIVE To evaluate the efficacy of a portable, wearable, wireless artificial pancreas system (the Diabetes Assistant [DiAs] running the Unified Safety System) on glucose control at home in overnight-only and 24/7 closed-loop control (CLC) modes in patients with type 1 diabetes. RESEARCH DESIGN AND METHODS At six clinical centers in four countries, 30 participants 18–66 years old with type 1 diabetes (43% female, 96% non-Hispanic white, median type 1 diabetes duration 19 years, median A1C 7.3%) completed the study. The protocol included a 2-week baseline sensor-augmented pump (SAP) period followed by 2 weeks of overnight-only CLC and 2 weeks of 24/7 CLC at home. Glucose control during CLC was compared with the baseline SAP. RESULTS Glycemic control parameters for overnight-only CLC were improved during the nighttime period compared with baseline for hypoglycemia (time <70 mg/dL, primary end point median 1.1% vs. 3.0%; P < 0.001), time in target (70–180 mg/dL: 75% vs. 61%; P < 0.001), and glucose variability (coefficient of variation: 30% vs. 36%; P < 0.001). Similar improvements for day/night combined were observed with 24/7 CLC compared with baseline: 1.7% vs. 4.1%, P < 0.001; 73% vs. 65%, P < 0.001; and 34% vs. 38%, P < 0.001, respectively. CONCLUSIONS CLC running on a smartphone (DiAs) in the home environment was safe and effective. Overnight-only CLC reduced hypoglycemia and increased time in range overnight and increased time in range during the day; 24/7 CLC reduced hypoglycemia and increased time in range both overnight and during the day. Compared with overnight-only CLC, 24/7 CLC provided additional hypoglycemia protection during the day.


Diabetes Care | 2016

Day and Night Closed-Loop Glucose Control in Patients With Type 1 Diabetes Under Free-Living Conditions: Results of a Single-Arm 1-Month Experience Compared With a Previously Reported Feasibility Study of Evening and Night at Home

Eric Renard; Anne Farret; Jort Kropff; Daniela Bruttomesso; Mirko Messori; Jerome Place; Roberto Visentin; Roberta Calore; Chiara Toffanin; Federico Di Palma; Giordano Lanzola; Paolo Magni; Federico Boscari; Silvia Galasso; Angelo Avogaro; Patrick Keith-Hynes; Boris P. Kovatchev; Simone Del Favero; Claudio Cobelli; Lalo Magni; J. Hans DeVries

OBJECTIVE After testing of a wearable artificial pancreas (AP) during evening and night (E/N-AP) under free-living conditions in patients with type 1 diabetes (T1D), we investigated AP during day and night (D/N-AP) for 1 month. RESEARCH DESIGN AND METHODS Twenty adult patients with T1D who completed a previous randomized crossover study comparing 2-month E/N-AP versus 2-month sensor augmented pump (SAP) volunteered for 1-month D/N-AP nonrandomized extension. AP was executed by a model predictive control algorithm run by a modified smartphone wirelessly connected to a continuous glucose monitor (CGM) and insulin pump. CGM data were analyzed by intention-to-treat with percentage time-in-target (3.9–10 mmol/L) over 24 h as the primary end point. RESULTS Time-in-target (mean ± SD, %) was similar over 24 h with D/N-AP versus E/N-AP: 64.7 ± 7.6 vs. 63.6 ± 9.9 (P = 0.79), and both were higher than with SAP: 59.7 ± 9.6 (P = 0.01 and P = 0.06, respectively). Time below 3.9 mmol/L was similarly and significantly reduced by D/N-AP and E/N-AP versus SAP (both P < 0.001). SD of blood glucose concentration (mmol/L) was lower with D/N-AP versus E/N-AP during whole daytime: 3.2 ± 0.6 vs. 3.4 ± 0.7 (P = 0.003), morning: 2.7 ± 0.5 vs. 3.1 ± 0.5 (P = 0.02), and afternoon: 3.3 ± 0.6 vs. 3.5 ± 0.8 (P = 0.07), and was lower with D/N-AP versus SAP over 24 h: 3.1 ± 0.5 vs. 3.3 ± 0.6 (P = 0.049). Insulin delivery (IU) over 24 h was higher with D/N-AP and SAP than with E/N-AP: 40.6 ± 15.5 and 42.3 ± 15.5 vs. 36.6 ± 11.6 (P = 0.03 and P = 0.0004, respectively). CONCLUSIONS D/N-AP and E/N-AP both achieved better glucose control than SAP under free-living conditions. Although time in the different glycemic ranges was similar between D/N-AP and E/N-AP, D/N-AP further reduces glucose variability.


Diabetes Care | 2016

Randomized summer camp crossover trial in 5-to 9-year-old children: Outpatient wearable artificial pancreas is feasible and safe

Simone Del Favero; Federico Boscari; Mirko Messori; Ivana Rabbone; Riccardo Bonfanti; Alberto Sabbion; Riccardo Schiaffini; Roberto Visentin; Roberta Calore; Yenny Teresa Leal Moncada; Silvia Galasso; Alfonso Galderisi; Valeria Vallone; Federico Di Palma; Eleonora Losiouk; Giordano Lanzola; Davide Tinti; Andrea Rigamonti; Marco Marigliano; Angela Zanfardino; Novella Rapini; Angelo Avogaro; Daniel Chernavvsky; Lalo Magni; Claudio Cobelli; Daniela Bruttomesso

OBJECTIVE The Pediatric Artificial Pancreas (PedArPan) project tested a children-specific version of the modular model predictive control (MMPC) algorithm in 5- to 9-year-old children during a camp. RESEARCH DESIGN AND METHODS A total of 30 children, 5- to 9-years old, with type 1 diabetes completed an outpatient, open-label, randomized, crossover trial. Three days with an artificial pancreas (AP) were compared with three days of parent-managed sensor-augmented pump (SAP). RESULTS Overnight time-in-hypoglycemia was reduced with the AP versus SAP, median (25th–75th percentiles): 0.0% (0.0–2.2) vs. 2.2% (0.0–12.3) (P = 0.002), without a significant change of time-in-target, mean: 56.0% (SD 22.5) vs. 59.7% (21.2) (P = 0.430), but with increased mean glucose 173 mg/dL (36) vs. 150 mg/dL (39) (P = 0.002). Overall, the AP granted a threefold reduction of time-in-hypoglycemia (P < 0.001) at the cost of decreased time-in-target, 56.8% (13.5) vs. 63.1% (11.0) (P = 0.022) and increased mean glucose 169 mg/dL (23) vs. 147 mg/dL (23) (P < 0.001). CONCLUSIONS This trial, the first outpatient single-hormone AP trial in a population of this age, shows feasibility and safety of MMPC in young children. Algorithm retuning will be performed to improve efficacy.


Diabetic Medicine | 2017

Psychological outcomes of evening and night closed-loop insulin delivery under free living conditions in people with Type 1 diabetes: a 2-month randomized crossover trial

Jort Kropff; J. DeJong; S. Del Favero; Jerome Place; Mirko Messori; B. Coestier; Anne Farret; Federico Boscari; Silvia Galasso; Angelo Avogaro; Daniela Bruttomesso; Claudio Cobelli; Eric Renard; Lalo Magni; J. H. DeVries

To assess the impact on fear of hypoglycaemia and treatment satisfaction with an artificial pancreas system used for 2 consecutive months, as well as participant acceptance of the artificial pancreas system.


Diabetes Care | 2016

Evaluating the Experience of Children With Type 1 Diabetes and Their Parents Taking Part in an Artificial Pancreas Clinical Trial Over Multiple Days in a Diabetes Camp Setting

Alda Troncone; Riccardo Bonfanti; Dario Iafusco; Ivana Rabbone; Alberto Sabbion; Riccardo Schiaffini; Alfonso Galderisi; Marco Marigliano; Novella Rapini; Andrea Rigamonti; Davide Tinti; Valeria Vallone; Angela Zanfardino; Federico Boscari; Simone Del Favero; Silvia Galasso; Giordano Lanzola; Mirko Messori; Federico Di Palma; Roberto Visentin; Roberta Calore; Yenny Leal; Lalo Magni; Eleonora Losiouk; Daniel Chernavvsky; Silvana Quaglini; Claudio Cobelli; Daniela Bruttomesso

OBJECTIVE To explore the experiences of children with type 1 diabetes and their parents taking part in an artificial pancreas (AP) clinical trial during a 7-day summer camp. RESEARCH DESIGN AND METHODS A semistructured interview, composed of 14 questions based on the Technology Acceptance Model, was conducted at the end of the clinical trial. Participants also completed the Diabetes Treatment Satisfaction Questionnaire (DTSQ, parent version) and the AP Acceptance Questionnaire. RESULTS Thirty children, aged 5–9 years, and their parents completed the study. A content analysis of the interviews showed that parents were focused on understanding the mechanisms, risks, and benefits of the new device, whereas the children were focused on the novelty of the new system. The parents’ main concerns about adopting the new system seemed related to the quality of glucose control. The mean scores of DTSQ subscales indicated general parents’ satisfaction (44.24 ± 5.99, range 32–53) and trustful views of diabetes control provided by the new system (7.8 ± 2.2, range 3–12). The AP Acceptance Questionnaire revealed that most parents considered the AP easy to use (70.5%), intended to use it long term (94.0%), and felt that it was apt to improve glucose control (67.0%). CONCLUSIONS Participants manifested a positive attitude toward the AP. Further studies are required to explore participants’ perceptions early in the AP development to individualize the new treatment as much as possible, and to tailor it to respond to their needs and values.


Diabetologia | 2014

The molecular signature of impaired diabetic wound healing identifies serpinB3 as a healing biomarker.

Gian Paolo Fadini; Mattia Albiero; Renato Millioni; Nicol Poncina; Mauro Rigato; Rachele Scotton; Federico Boscari; Enrico Brocco; Giorgio Arrigoni; G. Villano; C. Turato; Alessandra Biasiolo; Patrizia Pontisso; Angelo Avogaro

Aims/hypothesisChronic foot ulceration is a severe complication of diabetes, driving morbidity and mortality. The mechanisms underlying delaying wound healing in diabetes are incompletely understood and tools to identify such pathways are eagerly awaited.MethodsWound biopsies were obtained from 75 patients with diabetic foot ulcers. Matched subgroups of rapidly healing (RH, n = 17) and non-healing (NH, n = 11) patients were selected. Proteomic analysis was performed by labelling with isobaric tag for relative and absolute quantification and mass spectrometry. Differentially expressed proteins were analysed in NH vs RH for identification of pathogenic pathways. Individual sample gene/protein validation and in vivo validation of candidate pathways in mouse models were carried out.ResultsPathway analyses were conducted on 92/286 proteins that were differentially expressed in NH vs RH. The following pathways were enriched in NH vs RH patients: apoptosis, protease inhibitors, epithelial differentiation, serine endopeptidase activity, coagulation and regulation of defence response. SerpinB3 was strongly upregulated in RH vs NH wounds, validated as protein and mRNA in individual samples. To test the relevance of serpinB3 in vivo, we used a transgenic mouse model with α1-antitrypsin promoter-driven overexpression of human SERPINB3. In this model, wound healing was unaffected by SERPINB3 overexpression in non-diabetic or diabetic mice with or without hindlimb ischaemia. In an independent validation cohort of 47 patients, high serpinB3 protein content was confirmed as a biomarker of healing improvement.Conclusions/interpretationWe provide a benchmark for the unbiased discovery of novel molecular targets and biomarkers of impaired diabetic wound healing. High serpinB3 protein content was found to be a biomarker of successful healing in diabetic patients.

Collaboration


Dive into the Federico Boscari's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Anne Farret

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar

Jerome Place

University of Montpellier

View shared research outputs
Researchain Logo
Decentralizing Knowledge