Felipe J. Lara-Ortega
University of Jaén
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Felipe J. Lara-Ortega.
Journal of Chromatography A | 2014
José Robles-Molina; Felipe J. Lara-Ortega; Bienvenida Gilbert-López; Juan F. García-Reyes; Antonio Molina-Díaz
This article describes the development and validation of a liquid chromatography high-resolution mass spectrometry method for the simultaneous determination of over 400 multi-class priority and emerging pollutants with different physicochemical properties in environmental waters (surface water and wastewater). The proposed approach is based on the use of a database consisting of retention time/exact mass (of selected ions) pairs implemented with specific software for data analysis. The targeted list comprises 430 contaminants belonging to different compound categories, including 105 multiclass pharmaceuticals (analgesics/anti-inflammatories, antibiotics, lipid regulators, β-blockers, antiepileptic/psychiatrics ulcer healings, diuretics, hormones and bronchodilatadors), life-style products (caffeine, nicotine), 21 drugs of abuse and their metabolites, 279 pesticides and some of their more relevant metabolites, nitrosamines, flame retardants, plasticizers and perfluorinated compounds. The proposed approach included a simple offline solid phase extraction (SPE) step using polymeric cartridges (Oasis HLB) with 200mL of water sample loaded, followed by analysis by rapid resolution liquid chromatography electrospray time-of-flight mass spectrometry (LC-TOFMS) in both positive and negative modes. The identification of the positive findings is accomplished with the data from accurate masses of the target ions along with retention time data and characteristic in-source fragment ions. The overall method performance was satisfactory with limits of quantification lower than 10ngL(-1) for the 44% of studied compounds. Recoveries between 50% and 130% were obtained for the 65% of the analytes (281 compounds). Matrix effects occurring with wastewater matrices were also assessed. The developed method was applied to the determination of target analytes in real surface water and wastewater samples.
Talanta | 2016
Patricia Pérez-Ortega; Felipe J. Lara-Ortega; Juan F. García-Reyes; Bienvenida Gilbert-López; Marek Trojanowicz; Antonio Molina-Díaz
The feasibility of accurate-mass multi-residue screening methods using liquid chromatography high-resolution mass spectrometry (UHPLC-HRMS) using time-of-flight mass spectrometry has been evaluated, including over 625 multiclass food contaminants as case study. Aspects such as the selectivity and confirmation capability provided by HRMS with different acquisition modes (full-scan or full-scan combined with collision induced dissociation (CID) with no precursor ion isolation), and chromatographic separation along with main limitations such as sensitivity or automated data processing have been examined. Compound identification was accomplished with retention time matching and accurate mass measurements of the targeted ions for each analyte (mainly (de)protonated molecules). Compounds with the same nominal mass (isobaric species) were very frequent due to the large number of compounds included. Although 76% of database compounds were involved in isobaric groups, they were resolved in most cases (99% of these isobaric species were distinguished by retention time, resolving power, isotopic profile or fragment ions). Only three pairs could not be resolved with these tools. In-source CID fragmentation was evaluated in depth, although the results obtained in terms of information provided were not as thorough as those obtained using fragmentation experiments without precursor ion isolation (all ion mode). The latter acquisition mode was found to be the best suited for this type of large-scale screening method instead of classic product ion scan, as provided excellent fragmentation information for confirmatory purposes for an unlimited number of compounds. Leaving aside the sample treatment limitations, the main weaknesses noticed are basically the relatively low sensitivity for compounds which does not map well against electrospray ionization and also quantitation issues such as those produced by signal suppression due to either matrix effects from coeluting matrix or from coeluting analytes present in the standards solutions which often occur as they contain hundreds of the analytes included in the screening methods.
Talanta | 2016
Felipe J. Lara-Ortega; Francisco J. Sainz-Gonzalo; Bienvenida Gilbert-López; Juan F. García-Reyes; Antonio Molina-Díaz
A multicommuted flow injection method has been developed for the determination of phenolic species in virgin olive oil samples. The method is based on the inhibitory effect of antioxidants on a stable and colored radical cation formation from the colorless compound N,N-dimethyl-p-phenylenediamine (DMPD(•+)) in acidic medium in the presence of Fe(III) as oxidant. The signal inhibition by phenolic species and other antioxidants is proportional to their concentration in the olive oil sample. Absorbance was recorded at 515nm by means of a modular fiber optic spectrometer. Oleuropein was used as the standard for phenols determination and 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (trolox) was the reference standard used for total antioxidant content calculation. Linear response was observed within the range of 250-1000mg/kg oleuropein, which was in accordance with phenolic contents observed in commercial extra virgin olive oil in the present study. Fast and low-volume liquid-liquid extraction of the samples using 60% MeOH was made previous to their insertion in the flow multicommuted system. The five three-way solenoid valves used for multicommuted liquid handling were controlled by a homemade electronic interface and Java-written software. The proposed approach was applied to different commercial extra virgin olive oil samples and the results were consistent with those obtained by the Folin Ciocalteu (FC) method. Total time for the sample preparation and the analysis required in the present approach can be drastically reduced: the throughput of the present analysis is 8 samples/h in contrast to 1sample/h of the conventional FC method. The present method is easy to implement in routine analysis and can be regarded as a feasible alternative to FC method.
Talanta | 2018
Felipe J. Lara-Ortega; Miriam Beneito-Cambra; José Robles-Molina; Juan F. García-Reyes; Bienvenida Gilbert-López; Antonio Molina-Díaz
Analytical methods based on ambient ionization mass spectrometry (AIMS) combine the classic outstanding performance of mass spectrometry in terms of sensitivity and selectivity along with convenient features related to the lack of sample workup required. In this work, the performance of different mass spectrometry-based methods has been assessed for the direct analyses of virgin olive oil for quality purposes. Two sets of experiments have been setup: (1) direct analysis of untreated olive oil using AIMS methods such as Low-Temperature Plasma Mass Spectrometry (LTP-MS) or paper spray mass spectrometry (PS-MS); or alternatively (2) the use of atmospheric pressure ionization (API) mass spectrometry by direct infusion of a diluted sample through either atmospheric pressure chemical ionization (APCI) or electrospray (ESI) ionization sources. The second strategy involved a minimum sample work-up consisting of a simple olive oil dilution (from 1:10 to 1:1000) with appropriate solvents, which originated critical carry over effects in ESI, making unreliable its use in routine; thus, ESI required the use of a liquid-liquid extraction to shift the measurement towards a specific part of the composition of the edible oil (i.e. polyphenol rich fraction or lipid/fatty acid profile). On the other hand, LTP-MS enabled direct undiluted mass analysis of olive oil. The use of PS-MS provided additional advantages such as an extended ionization coverage/molecular weight range (compared to LTP-MS) and the possibility to increase the ionization efficiency towards nonpolar compounds such as squalene through the formation of Ag+ adducts with carbon-carbon double bounds, an attractive feature to discriminate between oils with different degree of unsaturation.
Analytica Chimica Acta | 2018
Felipe J. Lara-Ortega; José Robles-Molina; Sebastian Brandt; Alexander Schütz; Bienvenida Gilbert-López; Antonio Molina-Díaz; Juan F. García-Reyes; Joachim Franzke
Although electrospray ionization (ESI) remains the gold standard ionization source for LC-MS, it exhibits two main limitations: the occurrence of matrix effects and the limited ionization coverage towards nonpolar compounds. Dielectric barrier discharge ionization (DBDI) has gained attraction in recent years as a versatile ionization method in different applications and formats. Here, we report a thorough evaluation of DBDI as ionization interface for LC-MS, which reveals attractive advantages over ESI and atmospheric pressure chemical ionization (APCI) provided its singular ionization mechanism versatility. A suite of 80 pesticides across a wide range of physicochemical properties were selected and the results were compared with both ESI and APCI sources. Using a helium plasma operated in homogeneous regime with square-wave AC waveform and relatively low voltages (2.5 kV), not only DBDI was able to ionize compounds only amenable so far by GC-MS (eg. organochlorine species), but also offered a competitive performance in terms of sensitivity when contrasted with the commercial electrospray ionization source under equivalent conditions. Unlike ESI, DBDI mechanism occurs in the gas-phase, so the method is less affected by liquid-phase surface phenomena that yield ion suppression in ESI. Data collected in the positive ion mode revealed negligible matrix effect values (<10% suppression) for most of the studied compounds in different complex matrix extracts such as wastewater, orange or olive oil. This is also consistent with the absence of adduct formation whereas with ESI source, Na adduct formation is quite common with these species. In general, both sensitivity and average limits of quantitation for DBDI were similar to those obtained by ESI and better than APCI. Results showed that analyte coverage with DBDI is enhanced with respect to ESI and APCI sources being able to effectively analyze organochlorine compounds.
Food Analytical Methods | 2018
Felipe J. Lara-Ortega; Bienvenida Gilbert López; Miriam Beneito Cambra; Antonio Molina-Díaz
This article describes the applicability of multicommuted chemiluminescence flow injection analysis (MCFIA-CL) to the determination of olive oil quality parameters. Two automated MCFIA methods were developed and validated for the determination of peroxide value (PV) and phenolic compounds in commercial extra virgin olive oil samples. The PV method proposed is based on the chemiluminescent (CL) signal produced from luminol oxidation by the olive oil hydroperoxides in basic conditions using Co(II) as catalyst, while the determination of phenolic compounds is based on CL emission generated from permanganate reduction in acidic media by hydroalcoholic extracts of olive oil. The flow assemblies for automated liquid handling consisted, respectively, of 2 and 3 three-way solenoid valves, which were controlled by a homemade electronic interface and Java-written software together with a CL detector. The signals obtained correlated well against the PV and total phenolic contents measured by the official and the Folin-Ciocalteu methods, respectively. The linear response range observed for PV allows checking whether the samples are in compliance with European Union regulations. On the other hand, the phenolic compounds content also correlated well with data reported by the well-known FC method across the entire typical concentration range of these compounds in virgin olive oils. The proposed methods are faster, safer, and more environmentally friendly than the respective official or classical ones involving lower consumption of solvents, reagents, and sample, as well as less waste generation together with a high sample throughput. Moreover, they are straightforward and cost-effective to implement in routine analysis, and can be regarded as a feasible alternative to the official or classic methods.
Analytical Chemistry | 2018
Alexander Schütz; Felipe J. Lara-Ortega; Felix David Klute; Sebastian Brandt; Michael Schilling; Antje Michels; Damir Veza; Vlasta Horvatic; Juan F. García-Reyes; Joachim Franzke
Dielectric barrier discharges (DBDs) have been used as soft ionization sources (DBDI) for organic mass spectrometry (DBDI-MS) for approximately ten years. Helium-based DBDI is often used because of its good ionization efficiency, low ignition voltage, and homogeneous plasma conditions. Argon needs much higher ignition voltages than helium when the same discharge geometry is used. A filamentary plasma, which is not suitable for soft ionization, may be produced instead of a homogeneous plasma. This difference results in N2, present in helium and argon as an impurity, being Penning-ionized by helium but not by metastable argon atoms. In this study, a mixture of argon and propane (C3H8) was used as an ignition aid to decrease the ignition and working voltages, because propane can be Penning-ionized by argon metastables. This approach leads to homogeneous argon-based DBDI. Furthermore, operating DBDI in an open environment assumes that many uncharged analyte molecules do not interact with the reactant ions. To overcome this disadvantage, we present a novel approach, where the analyte is introduced in an enclosed system through the discharge capillary itself. This nonambient DBDI-MS arrangement is presented and characterized and could advance the novel connection of DBDI with analytical separation techniques such as gas chromatography (GC) and high-pressure liquid chromatography (HPLC) in the near future.
Food Analytical Methods | 2017
Patricia Pérez-Ortega; Felipe J. Lara-Ortega; Bienvenida Gilbert-López; David Moreno-González; Juan F. García-Reyes; Antonio Molina-Díaz
Talanta | 2015
Juan C. Domínguez-Romero; Juan F. García-Reyes; Felipe J. Lara-Ortega; Antonio Molina-Díaz
Food Analytical Methods | 2016
Patricia Pérez-Ortega; Felipe J. Lara-Ortega; Juan F. García-Reyes; Miriam Beneito-Cambra; Bienvenida Gilbert-López; Natividad Ramos Martos; Antonio Molina-Díaz