Featured researches published by Filip Vanhavere.


Radiation Measurements | 1998

A Combined Use of the BD-PND and BDT Bubble Detectors in Neutron Dosimetry.

Filip Vanhavere; M Loos; Ajm Plompen; E. Wattecamps; Hubert Thierens

The BDT bubble detector is predominantly sensitive to thermal neutrons and the BD-PND bubble detector is only sensitive to neutrons with energies larger than about 50 keV. The response of both types of bubble detectors was measured for four radionuclide sources, for thermal neutrons and for several mono-energetic neutron beams. At the same time the sensitivity given by the manufacturer was checked. Combining the two measured sensitivity functions with adequate weighing factors provides a better neutron dose equivalent response for the entire energy range. The effect of the new ICRP conversion factors (ICRP, 1996) following the ICRP 60 recommendations (ICRP, 1990) is determined.


Astrobiology | 2012

Cosmic Radiation Exposure of Biological Test Systems During the EXPOSE-E Mission

Thomas Berger; M. Hajek; P. Bilski; Christine Körner; Filip Vanhavere; Günther Reitz

In the frame of the EXPOSE-E mission on the Columbus external payload facility EuTEF on board the International Space Station, passive thermoluminescence dosimeters were applied to measure the radiation exposure of biological samples. The detectors were located either as stacks next to biological specimens to determine the depth dose distribution or beneath the sample carriers to determine the dose levels for maximum shielding. The maximum mission dose measured in the upper layer of the depth dose part of the experiment amounted to 238±10 mGy, which relates to an average dose rate of 408±16 μGy/d. In these stacks of about 8u2009mm height, the dose decreased by 5-12% with depth. The maximum dose measured beneath the sample carriers was 215±16 mGy, which amounts to an average dose rate of 368±27 μGy/d. These values are close to those assessed for the interior of the Columbus module and demonstrate the high shielding of the biological experiments within the EXPOSE-E facility. Besides the shielding by the EXPOSE-E hardware itself, additional shielding was experienced by the external structures adjacent to EXPOSE-E, such as EuTEF and Columbus. This led to a dose gradient over the entire exposure area, from 215±16 mGy for the lowest to 121±6 mGy for maximum shielding. Hence, the doses perceived by the biological samples inside EXPOSE-E varied by 70% (from lowest to highest dose). As a consequence of the high shielding, the biological samples were predominantly exposed to galactic cosmic heavy ions, while electrons and a significant fraction of protons of the radiation belts and solar wind did not reach the samples.


Radiation Protection Dosimetry | 2010

Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence

Koen Beerten; Filip Vanhavere

New data are presented with regard to the relative OSL sensitivity of three different emergency dosemeters irradiated to various photon energies approximately between 48 and 1250 keV using blue excitation light. Investigated components extracted from commonly worn objects include those from USB flash drives (alumina substrate), mobile phones (Ba-rich silicate) and credit cards (chip card module). Several basic properties have been investigated such as the overall radiation sensitivity, the shape of the decay curve and fading of the OSL signal. An increase of the sensitivity for low energies relative to (60)Co gamma rays can be observed for the three dosemeters, the increase being very pronounced for the Ba-rich component (factor of 10) and less pronounced for the chip card module (factor of 2). It is concluded that proper dose correction factors for photon energy have to be applied in order to accurately determine the absorbed dose to tissue. The OSL sensitivity to neutron irradiation was investigated as well, but this was found to be less than the gamma sensitivity.


Radiation Protection Dosimetry | 2013

Characterisation of neutron fields at Cernavoda NPP

Vanessa Cauwels; Filip Vanhavere; Dorin Dumitrescu; Alecsandru Chirosca; L. G. Hager; Marc Million; James Bartz

Near a nuclear reactor or a fuel container, mixed neutron/gamma fields are very common, necessitating routine neutron dosimetry. Accurate neutron dosimetry is complicated by the fact that the neutron effective dose is strongly dependent on the neutron energy and the direction distribution of the neutron fluence. Neutron field characterisation is indispensable if one wants to obtain a reliable estimate for the neutron dose. A measurement campaign at CANDU nuclear power plant located in Cernavoda, Romania, was set up to characterise the neutron fields in four different locations and to investigate the behaviour of different neutron personal dosemeters. This investigation intends to assist in choosing a suitable neutron dosimetry system at this nuclear power plant.


Radiation Protection Dosimetry | 2016

SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE.

M. De Saint-Hubert; C. Saldarriaga Vargas; O. Van Hoey; W. Schoonjans; V. De Smet; G. Mathot; Frédéric Stichelbaut; Giacomo Paolo Manessi; N. Dinar; E. Aza; Christopher Cassell; Marco Silari; Filip Vanhavere

The formation of secondary high-energy neutrons in proton therapy can be a concern for radiation protection of staff. In this joint intercomparative study (CERN, SCK•CEN and IBA/IRISIB/ULB), secondary neutron doses were assessed with different detectors in several positions in the Proton Therapy Centre, Essen (Germany). The ambient dose equivalent H(*)(10) was assessed with Berthold LB 6411, WENDI-2, tissue-equivalent proportional counter (TEPC) and Bonner spheres (BS). The personal dose equivalent Hp(10) was measured with two types of active detectors and with bubble detectors. Using spectral and basic angular information, the reference Hp(10) was estimated. Results concerning staff exposure show H(*)(10) doses between 0.5 and 1 nSv/monitoring unit in a technical room. The LB 6411 showed an underestimation of H(*)(10), while WENDI-2 and TEPC showed good agreement with the BS data. A large overestimation for Hp(10) was observed for the active personal dosemeters, while the bubble detectors showed only a slight overestimation.


Radiation Protection Dosimetry | 2014

Establishing local workplace field correction factors for neutron personal dosemeters.

Filip Vanhavere; Vanessa Cauwels

The present personal neutron dosemeters still need local correction factors to be able to provide accuracy comparable with photon dosemeters. Characterisation of the local neutron field is an indispensable part of neutron dosimetry to obtain such correction factors. It is often overlooked that besides characterisation in the neutron energy also the directional distribution of neutrons plays a crucial part in this characterisation. The authors have done such characterisation in the energy and angle for four workplace fields in Paks NPP. For this a relatively simple approximation method was used using the Nprobe for the energy distribution and measurements on the six sides of the slab phantom with personal dosemeters for the directional distribution. This allowed one to estimate a reference neutron Hp(10) rate and to compare it with the response of several neutron personal dosemeters.


Radiation Protection Dosimetry | 2018

CHARACTERIZATION OF FLUORESCENT NUCLEAR TRACK DETECTORS AS CRITICALITY DOSIMETERS II

J. Harrison; B. Moreno; O. Van Hoey; L.-C. Mihailescu; Filip Vanhavere; M. Million; V. Fomenko; M. Akselrod

Fluorescent nuclear track detectors (FNTDs) as criticality dosimeters for both neutrons and gamma are further characterized in terms of angular dependence and quick dose assessment. The power spectrum integral depth profiles obtained from stacks of fluorescent images acquired within FNTDs exposed to a broad spectrum neutron field at various angles are analyzed to determine a calibration curve for angular dependence. MCNPX simulations were shown to be in good agreement with experimental results. A prototype triage reader was also designed and tested for quick assessment of dose. An unfolding technique incorporating both energy dependence and angular dependence is discussed. The advantages and shortcomings of using FNTDs in the event of a criticality excursion accident are analyzed.


Radiation Protection Dosimetry | 2012

A method for evaluating personal dosemeters in workplace with neutron fields

L.F. Nascimento; Vanessa Cauwels; Filip Vanhavere

Passive detectors, as albedo or track-etch, still dominate the field of neutron personal dosimetry, mainly due to their low-cost, high-reliability and elevated throughput. However, the recent appearance in the market of electronic personal dosemeters for neutrons presents a new option for personal dosimetry. In addition to passive detectors, electronic personal dosemeters necessitate correction factors, concerning their energy and angular response dependencies. This paper reports on the results of a method to evaluate personal dosemeters for workplace where neutrons are present. The approach here uses few instruments and does not necessitate a large mathematical workload. Qualitative information on the neutron energy spectrum is acquired using a simple spectrometer (Nprobe), reference values for H*(10) are derived from measurements with ambient detectors (Studsvik, Berthold and Harwell) and angular information is measured using personal dosemeters (electronic and bubbles dosemeters) disposed in different orientations on a slab phantom.


Radiation Protection Dosimetry | 2018

THE CHALLENGES IN THE ESTIMATION OF THE EFFECTIVE DOSE WHEN WEARING RADIOPROTECTIVE GARMENTS

C. Saldarriaga Vargas; Lara Struelens; Filip Vanhavere

The performance of a single or double dosimetry (SD or DD) algorithm on estimating effective dose wearing radioprotective garments (ERPG) depends on the specific irradiation conditions. This study investigates the photon energies and angles of incidence for which the estimation of ERPG with the personal dose equivalents measured over and under the RPG (Ho and Hu) becomes more challenging. The energy and angular dependences of ERPG, Ho and Hu were Monte Carlo calculated for photon exposures. The personal dosimeter of SCK · CEN was modeled and used to determine Ho and Hu. Different SD and DD algorithms were tested and critical exposure conditions were identified. Moreover, the influence of calibration methods was investigated for the SCK · CEN dosimeter when worn over RPG. We found that the accuracy with which ERPG is calculated using SD and DD is strongly dependent on the energy and angle of incidence of photons. Also, the energy of the photon beam used to calibrate the Ho dosimeter can bias the estimation of ERPG.


Radiation Protection Dosimetry | 2018

MICRODOSIMETRIC MEASUREMENT OF SECONDARY RADIATION IN THE PASSIVE SCATTERED PROTON THERAPY ROOM OF iTHEMBA LABS USING A TISSUE-EQUIVALENT PROPORTIONAL COUNTER

S. Chiriotti; A. Parisi; Filip Vanhavere; M. De Saint-Hubert; C.R. Vandevoorde; J.P. Slabbert; P. Beukes; E. de Kock; Julyan E. Symons

&NA; Measurements of the dose equivalent at different distances from the isocenter of the proton therapy center at iThemba LABS were previously performed with a tissue‐equivalent proportional counter (TEPC). These measurements showed that the scattered radiation levels were one or two orders of magnitude higher in comparison to other passive scattering delivery systems. In order to reduce these radiation levels, additional shielding was installed shortly after the measurements were done. Therefore, the aim of this work is to quantify and assess the reduction of the secondary doses delivered in the proton therapy room at iThemba LABS after the installation of the additional shielding. This has been performed by measuring microdosimetric spectra with a TEPC at 11 locations around the isocenter when a clinical modulated beam of 200 MeV proton was impinging onto a water phantom placed at the isocenter.

Collaboration


Dive into the Filip Vanhavere's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

P. Bilski

Polish Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

M. Hajek

Vienna University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

D. Zhou

Universities Space Research Association

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Iva Jadrnickova

Czech Technical University in Prague

View shared research outputs
Top Co-Authors

Avatar

Yukio Uchihori

National Institute of Radiological Sciences

View shared research outputs
Researchain Logo
Decentralizing Knowledge