Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Flávia Gonçalves is active.

Publication


Featured researches published by Flávia Gonçalves.


European Journal of Oral Sciences | 2009

Influence of BisGMA, TEGDMA, and BisEMA contents on viscosity, conversion, and flexural strength of experimental resins and composites

Flávia Gonçalves; Yoshio Kawano; Carmem Pfeifer; Jeffrey W. Stansbury; Roberto R. Braga

Different monomer structures lead to different physical and mechanical properties for both the monomers and the polymers. The objective of this study was to determine the influence of the bisphenylglycidyl dimethacrylate (BisGMA) concentration (33, 50 or 66 mol%) and the co-monomer content [triethylene glycol dimethacrylate (TEGDMA), ethoxylated bisphenol-A dimethacrylate (BisEMA), or both in equal parts] on viscosity (eta), degree of conversion (DC), and flexural strength (FS). Eta was measured using a viscometer, DC was obtained by Fourier transfer Raman (FT-Raman) spectroscopy, and FS was determined by three-point bending. At 50 and 66% BisGMA, increases in eta were observed following the partial and total substitution of TEGDMA by BisEMA. For 33% BisGMA, eta increased significantly only when no TEGDMA was present. The DC was influenced by BisGMA content and co-monomer type. Mixtures containing 66% BisGMA showed a lower DC compared with mixtures containing other concentrations of BisGMA. The BisEMA mixtures had a lower DC compared with the TEGDMA mixtures. The FS was influenced by co-monomer content only. BisEMA mixtures presented a statistically lower FS, followed by TEGDMA + BisEMA mixtures, and then by TEGDMA mixtures. Partial or total replacement of TEGDMA by BisEMA increased eta, which was associated with the observed decreases in DC and FS. Although the BisGMA content influenced the DC, it did not affect the FS results.


Dental Materials | 2010

Contraction stress related to composite inorganic content

Flávia Gonçalves; Yoshio Kawano; Roberto R. Braga

OBJECTIVES The role of inorganic content on physical properties of resin composites is well known. However, its influence on polymerization stress development has not been established. The aim of this investigation was to evaluate the influence of inorganic fraction on polymerization stress and its determinants, namely, volumetric shrinkage, elastic modulus and degree of conversion. METHODS Eight experimental composites containing 1:1 BisGMA (bisphenylglycidyl dimethacrylate):TEGDMA (triethylene glycol dimethacrylate) (in mol) and barium glass at increasing concentrations from 25 to 60 vol.% (5% increments) were tested. Stress was determined in a universal test machine using acrylic as bonding substrate. Nominal polymerization stress was obtained diving the maximum load by the cross-surface area. Shrinkage was measured using a water picnometer. Elastic modulus was obtained by three-point flexural test. Degree of conversion was determined by FT-Raman spectroscopy. RESULTS Polymerization stress and shrinkage showed inverse relationships with filler content (R(2)=0.965 and R(2)=0.966, respectively). Elastic modulus presented a direct correlation with inorganic content (R(2)=0.984). Degree of conversion did not vary significantly. Polymerization stress showed a strong direct correlation with shrinkage (R(2)=0.982) and inverse with elastic modulus (R(2)=0.966). SIGNIFICANCE High inorganic contents were associated with low polymerization stress values, which can be explained by the reduced volumetric shrinkage presented by heavily filled composites.


Dental Materials | 2011

BisGMA/TEGDMA ratio and filler content effects on shrinkage stress

Flávia Gonçalves; Caio L. N. Azevedo; J.L. Ferracane; Roberto R. Braga

OBJECTIVE To investigate the contributions of BisGMA:TEGDMA and filler content on polymerization stress, along with the influence of variables associated with stress development, namely, degree of conversion, reaction rate, shrinkage, elastic modulus and loss tangent for a series of experimental dental composites. METHODS Twenty formulations with BisGMA:TEGDMA ratios of 3:7, 4:6, 5:5, 6:4 and 7:3 and barium glass filler levels of 40, 50, 60 or 70wt% were studied. Polymerization stress was determined in a tensilometer, inserting the composite between acrylic rods fixed to clamps of a universal test machine and dividing the maximum load recorded by the rods cross-sectional area. Conversion and reaction rate were determined by infra-red spectroscopy. Shrinkage was measured by mercury dilatometer. Modulus was obtained by three-point bending. Loss tangent was determined by dynamic nanoindentation. Regression analyses were performed to estimate the effect of organic and inorganic contents on each studied variable, while a stepwise forward regression identified significant variables for polymerization stress. RESULTS All variables showed dependence on inorganic concentration and monomeric content. The resin matrix showed a stronger influence on polymerization stress, conversion and reaction rate, whereas filler fraction showed a stronger influence on shrinkage, modulus and loss tangent. Shrinkage and conversion were significantly related to polymerization stress. SIGNIFICANCE Both the inorganic filler concentration and monomeric content affect polymerization stress, but the stronger influence of the resin matrix suggests that it may be possible to reduce stress by modifying resin composition without sacrificing filler content. The main challenge is to develop formulations with low shrinkage without sacrificing degree of conversion.


Journal of Dental Research | 2008

Contraction Stress Determinants in Dimethacrylate Composites

Flávia Gonçalves; Carmem Silvia Costa Pfeifer; Jack L. Ferracane; Roberto R. Braga

The influence of composite organic content on polymerization stress development remains unclear. It was hypothesized that stress was directly related to differences in degree of conversion, volumetric shrinkage, elastic modulus, and maximum rate of polymerization encountered in composites containing different BisGMA (bisphenylglycidyl dimethacrylate) concentrations and TEGDMA (triethylene glycol dimethacrylate) and/or BisEMA (ethoxylated bisphenol-A dimethacrylate) as co-monomers. Stress was determined in a tensilometer. Volumetric shrinkage was measured with a mercury dilatometer. Elastic modulus was obtained by flexural test. We used fragments of flexural specimens to determine degree of conversion by FT-Raman spectroscopy. Reaction rate was determined by differential scanning calorimetry. Composites with lower BisGMA content and those containing TEGDMA showed higher stress, conversion, shrinkage, and elastic modulus. Polymerization rate did not vary significantly, except for the lower value of the 66% TEGDMA composite. We used linear regressions to evaluate the association between polymerization stress and conversion (R2 = 0.905), shrinkage (R2 = 0.825), and modulus (R2 = 0.623).


Dental Materials | 2010

Influence of matrix composition on polymerization stress development of experimental composites

Flávia Gonçalves; C.S. Pfeifer; Jeffrey W. Stansbury; Sheldon M. Newman; Roberto R. Braga

OBJECTIVE Stress development at the tooth/restoration interface is one of the most important reasons for failure of adhesive restorations. The aim of this study was to evaluate the influence of BisGMA/TEGDMA (B/T) and UDMA/TEGDMA (U/T) ratios on polymerization stress (PS) and on the variables related to its development: degree of conversion (DC), polymerization maximum rate (Rp(max)), volumetric shrinkage (VS), elastic modulus (E), stress relaxation (SR) and viscosity of experimental composites. METHOD Composites were formulated containing B/T or U/T in mol% ratios of 2:8, 3:7, 4:6, 5:5, 6:4, 7:3 and 8:2, and 15 wt% of fumed silica. PS was determined with a universal testing machine. VS was measured with a linometer. E and SR were obtained in three-point bending. DC and Rp(max) were determined by real time NIR spectroscopy and viscosity was measured in viscometer. Data were submitted to one-way ANOVA, Tukey test (alpha=0.05%) and regression analyses. RESULTS PS, VS, E and DC decreased and viscosity and Rp(max) increased with base monomer content in both series. PS showed strong correlation with VS, DC and viscosity. PS, VS and DC were higher and viscosity was lower for UDMA-based materials. SIGNIFICANCE Reduced viscosity, kinetics parameters and molecular characteristics led UDMA-based composites to elevated conversion and relatively lower PS at lower TEGDMA contents, compared to B/T composites.


Acta Biomaterialia | 2010

Influence of the bonding substrate in dental composite polymerization stress testing

L.C.C. Boaro; Flávia Gonçalves; Roberto R. Braga

Our objective was to compare the polymerization stress (sigma(pol)) of a series of composites obtained using poly(methyl methacrylate) (PMMA) or glass as bonding substrates, and to compare the results with those from in vitro microleakage of composite restorations. The tested hypothesis was that stress values obtained in a less rigid testing system (i.e. using PMMA) would show a better relationship with microleakage data. Five dental composites were tested: Filtek Z250 (FZ), Z100 (Z1), Concept (CO), Durafill (DU) and Heliomolar (HM). sigma(pol) was determined in 1mm high specimens inserted between two rods (Ø=5mm) of either PMMA or glass. The composite elastic modulus (E) was obtained by three-point bending. sigma(pol) and E data were submitted to a one-way analysis of variance/Tukey test (alpha=0.05). For the microleakage test (MI), bovine incisors received cylindrical cavities (Ø=5mm, h=2mm), which were restored in bulk. After storage for 24h in water, specimens were subjected to dye penetration using AgNO(3) as tracer. Specimens were sectioned twice, perpendicularly, and microleakage was measured (in millimeters) under 20x magnification. Data from MI were submitted to the Kruskal-Wallis test. Means (SD) of sigma(pol) (MPa) using glass/PMMA were FZ: 7.5(1.8)(A)/2.5(0.2)(bc); Z1: 7.3(0.5)(A)/2.8(0.3)(ab); CO: 6.8(1.1)(A)/3.2(0.5)(a); DU: 4.5(0.7)(B)/2.0(0.2)(bc); HM: 3.5(0.2)(B)/2.3(0.3)(c). sigma(pol) obtained using PMMA rods were 34-67% lower than with glass. Means (SD) for tooth average/tooth maximum microleakage were FZ: 0.92(0.19)(B)/1.53(0.30)(a); Z1: 1.19(0.21)(A)/1.75(0.20)(a); CO: 1.26(0.25)(A)/1.78(0.24)(a); DU: 0.83(0.30)(B)/1.68(0.46)(a); HM: 0.81(0.27)(B)/1.64(0.54)(a). The tested hypothesis was confirmed, as the composites showed the same ordering both in the polymerization stress test using PMMA rods and in the microleakage test.


Materials | 2015

Hybrid Membranes of PLLA/Collagen for Bone Tissue Engineering: A Comparative Study of Scaffold Production Techniques for Optimal Mechanical Properties and Osteoinduction Ability

Flávia Gonçalves; Ricardo Bentini; Mariana C. Burrows; Ana Claudia Oliveira Carreira; Patrícia M. Kossugue; Mari Cleide Sogayar; Luiz H. Catalani

Synthetic and natural polymer association is a promising tool in tissue engineering. The aim of this study was to compare five methodologies for producing hybrid scaffolds for cell culture using poly-l-lactide (PLLA) and collagen: functionalization of PLLA electrospun by (1) dialkylamine and collagen immobilization with glutaraldehyde and by (2) hydrolysis and collagen immobilization with carbodiimide chemistry; (3) co-electrospinning of PLLA/chloroform and collagen/hexafluoropropanol (HFP) solutions; (4) co-electrospinning of PLLA/chloroform and collagen/acetic acid solutions and (5) electrospinning of a co-solution of PLLA and collagen using HFP. These materials were evaluated based on their morphology, mechanical properties, ability to induce cell proliferation and alkaline phosphatase activity upon submission of mesenchymal stem cells to basal or osteoblastic differentiation medium (ODM). Methods (1) and (2) resulted in a decrease in mechanical properties, whereas methods (3), (4) and (5) resulted in materials of higher tensile strength and osteogenic differentiation. Materials yielded by methods (2), (3) and (5) promoted osteoinduction even in the absence of ODM. The results indicate that the scaffold based on the PLLA/collagen blend exhibited optimal mechanical properties and the highest capacity for osteodifferentiation and was the best choice for collagen incorporation into PLLA in bone repair applications.


Operative Dentistry | 2011

Comparison of two-step versus four-step composite finishing/ polishing disc systems: Evaluation of a new two-step composite polishing disc system

Jb da Costa; Flávia Gonçalves; J.L. Ferracane

OBJECTIVE The purpose of this study was to evaluate surface finish and gloss of a two-step composite finishing/polishing (F/P) disc system compared with two multistep systems on five composites. METHODS Seventy-five disc-shaped composite specimens (D=10.0 mm, 2 mm thick, n=15 per composite) were made of microfill (Durafill-D), nanofill (Filtek Supreme-FS), nanohybrid (Premise-PR), and microhybrids (Filtek Z250-FZ, Esthet-EX). One side of each specimen was initially finished with a carbide bur. Five specimens of each resin composite were randomly assigned to receive full F/P by each of the disc systems: two-step (Enhance Flex NST-EF) and four-step (Sof-Lex-SL, Super-Snap-SS). Surface gloss was measured with a glossmeter and surface roughness was measured with a profilometer. Results were analyzed by two-way analysis of variance (ANOVA)/Tukeys (α<0.05). RESULTS No difference in gloss was noted among the three F/P systems when used with D and EX; no difference between SL and EF when used with any composite, except for FS; and no difference between SL and SS when used with any composite. SL and EF showed similar surface roughness when used on all composites, except for EX. EF and SS showed similar surface roughness on PR. SL and SS showed similar surface roughness values on every composite, except for FZ. CONCLUSIONS EF was capable of providing similar gloss and surface roughness to SL on four composites evaluated but was not able to produce as glossy or as smooth a surface as SS for three of the five composites.


Brazilian Oral Research | 2015

Influence of polymeric matrix on the physical and chemical properties of experimental composites

Flávia Gonçalves; L.C.C. Boaro; Caroline Lumi Miyazaki; Yoshio Kawano; Roberto R. Braga

Nowadays, the main reasons for replacement of resin-based composite restorations are fracture or problems with the integrity of their interface, such as marginal staining, microleakage, or secondary caries. The aim of the present study was to evaluate the influence of the organic matrix on polymerization stress (PS), degree of conversion (DC), elastic modulus (E), flexural strength (FS), Knoop hardness (KHN), sorption (SP), and solubility (SL). In order to obtain a material which combines better mechanical properties with lower PS, seven experimental composites were prepared using BisGMA to TEGDMA molar ratios of 2:8, 3:7, 4:6, 5:5, 6:4, 7:3 and 8:2 and 40% of silica. PS was obtained in a universal testing machine, using acrylic as bonding substrate. DC was determined using Fourier Transform Raman spectroscopy. E and FS were obtained by the three-point bending test. KHN was measured by a microindentation test using a load of 25 g for 30 s. SP and SL were assessed according to ISO 4049. The data were submitted to one-way ANOVA. The increase in BisGMA concentration resulted in the decrease of PS, DC, E, FS and KHN. However, it did not change the SP and SL values. FS, E and KHN showed a strong and direct relationship with the DC of the materials. The composite material with a BisGMA to TEGDMA molar ratio of 1:1 was the one with better mechanical properties and lower PS.


Journal of Biomaterials Applications | 2016

The performance of bone tissue engineering scaffolds in in vivo animal models: A systematic review

Marcos Ricardo Dantas Oliveira Ferraz de Misquita; Ricardo Bentini; Flávia Gonçalves

Bone tissue engineering is an excellent alternative for the regeneration of large bone defects caused by trauma or bone pathologies. Scaffolds, stem cells, and bioactive molecules are the three key components of bone regeneration. Although a wide range of biomaterials of various compositions and structures has been proposed in the literature, these materials are rarely used in clinical applications. Therefore, more standardized studies are required to design scaffolds that enable better bone regeneration and are suitable for clinical use. The aim of this systematic review was to compare the performance of scaffolds used in preclinical animal studies to determine which class of materials has achieved a higher rate of bone neoformation (osteoinduction and osteoconduction). The selected studies were divided into three groups according to the following experimental models: studies that used subcutaneous models, bone defects in calvaria, and bone defects in long bones. Despite the large number of parameters in the included studies, we generally concluded that biomaterials containing calcium phosphates had important osteoinductive effects and were essential for better performance of the materials. Furthermore, natural polymers generally had better performance than synthetic polymers did, especially when the materials were associated with stem cells. The combination of materials from different classes was the most promising strategy for bone tissue regeneration.

Collaboration


Dive into the Flávia Gonçalves's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

L.C.C. Boaro

University of São Paulo

View shared research outputs
Top Co-Authors

Avatar

Yoshio Kawano

University of São Paulo

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge