Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Flávio Henrique Baggio Aguiar is active.

Publication


Featured researches published by Flávio Henrique Baggio Aguiar.


Brazilian Oral Research | 2005

Effect of light curing tip distance and resin shade on microhardness of a hybrid resin composite

Flávio Henrique Baggio Aguiar; Carolina Rodrigues Lazzari; Débora Alves Nunes Leite Lima; Gláucia Maria Bovi Ambrosano; José Roberto Lovadino

Resin composite shades and resin composite polymerization performed with a distanced light tip are factors that can affect polymerization effectiveness. This in vitro study aimed to evaluate the influence of curing tip distance and resin shade on the microhardness of a hybrid resin composite (Z250-3M ESPE). Forty-five resin composite specimens were randomly prepared and divided into nine experimental groups (n = 5): three curing tip distances (2 mm, 4 mm, and 8 mm) and three resin shades (A1, A3.5, and C2). All samples were polymerized with a continuous output at 550 mW/cm(2). After 24 hours, Knoop microhardness measurements were obtained on the top and bottom surfaces of the sample, with a load of 25 grams for 10 seconds. Five indentations were performed on each surface of each sample. Results showed that bottom surface samples light-cured at 2 mm and 4 mm presented significantly higher hardness values than samples light-cured at 8 mm. The resin shade A1 presented higher hardness values and was statistically different from C2. The resin shade A3.5 did not present statistical differences from A1 and C2. For the top surface, there were no statistical differences among the curing tip distances. For all experimental conditions, the top surface showed higher hardness values than the bottom surface. It was concluded that light curing tip distance and resin shade are important factors to be considered for obtaining adequate polymerization.


Journal of Prosthodontics | 2009

In vitro evaluation of the effectiveness of bleaching agents activated by different light sources.

Débora Alves Nunes Leite Lima; Flávio Henrique Baggio Aguiar; Priscila Christiane Suzy Liporoni; Egberto Munin; Gláucia Maria Bovi Ambrosano; José Roberto Lovadino

PURPOSE This study evaluated the efficacy of tooth whitening and color stability at different time periods after treatment. MATERIALS AND METHODS Blocks obtained from human molars were divided into 15 groups (n = 5) by bleaching agents: 35% hydrogen peroxide (Whiteness HP and Opalescence Xtra) and 37% carbamide peroxide (Whiteness Super); and light sources: halogen lamp and plasma arc lamp (bleach mode), LED/diode laser, argon laser, and no light source. The efficacy of bleaching was measured using a spectrophotometer. Six bleaching sessions were performed (times 1 to 6). The specimens were submitted to another reading 7, 15, and 30 days after the end of bleaching (times 7, 8, and 9). The results were submitted to ANOVA followed by Tukey test and polynomial regression (p < 0.05). RESULTS Carbamide peroxide significantly differed from hydrogen peroxide, presenting low reflectance values. Activated versus non-activated bleaching did not differ significantly for any gel tested, except for Whiteness HP activated by argon laser, which presented the lowest mean reflectance values. The results obtained with hydrogen peroxide revealed a decrease in reflectance values one month after the end of treatment. For carbamide peroxide, this decrease was not observed. CONCLUSION The halogen lamp presented the same or higher efficacy than non-activated bleaching, which had a longer gel contact period. When hydrogen peroxide was used, a decrease in reflectance values was observed 30 days after the end of bleaching.


Journal of Esthetic and Restorative Dentistry | 2008

Effect of curing lights and bleaching agents on physical properties of a hybrid composite resin.

Débora Alves Nunes Leite Lima; Rodrigo Sversut de Alexandre; Ana Cláudia Moraes Martins; Flávio Henrique Baggio Aguiar; Gláucia Maria Bovi Ambrosano; José Roberto Lovadino

UNLABELLED The aim of this in vitro study was to evaluate the microhardness (MH) and diametral tensile strength (DTS) of a minifill hybrid composite (Filtek Z250, 3M ESPE), polymerized with halogen lamp or second generation light-emitting diode (LED), submitted to different bleaching agents. Composite resin specimens were randomly polymerized according to experimental groups (halogen, 550 mW/cm(2)/20 seconds; LED, 550 mW/cm(2)/25 seconds) and subdivided into three subgroups (N=8): A, without bleaching (control); H, 35% hydrogen peroxide; and C, 16% carbamide peroxide. After that, the MH test and DTS test were performed. Two-way analysis of variance (whitening x light) and Tukeys tests (alpha=5%) were performed. For DTS, there were no statistical differences among the bleaching agents and the control group; however, the halogen group presented statistically lower DTS (p<0.05) than the LED group. For the MH test, the carbamide peroxide group presented statistically lower MH means (p<0.05) than the control groups, and there were no statistical differences among the light-curing units. Sixteen percent carbamide peroxide reduced the MH of the hybrid composite tested. The second generation LED presented a performance similar to or better than the halogen lamp for hardness and DTS, respectively. CLINICAL SIGNIFICANCE Repolishing of minifill hybrid composite is suggested, as the alteration caused after the contact with 16% carbamide peroxide was limited to the material surface. The second generation light-emitting diode is a good option for a curing light device when the polymerization initiator of composite resin is camphorquinone.


Brazilian Oral Research | 2008

In vitro assessment of the effectiveness of whitening dentifrices for the removal of extrinsic tooth stains

Débora Alves Nunes Leite Lima; André Luís Faria e Silva; Flávio Henrique Baggio Aguiar; Priscila Christiane Suzy Liporoni; Egberto Munin; Gláucia Maria Bovi Ambrosano; José Roberto Lovadino

This in vitro study evaluated the effectiveness of whitening dentifrices for the removal of extrinsic tooth stains. Twenty dental blocks (4 x 4 mm), including enamel and dentine, removed from freshly extracted bovine incisors, were randomly divided into 4 groups: G1--distilled water, G2--Colgate, G3--Crest Extra Whitening and G4--Rapid White. In all specimens, the dentin was covered with colorless nail polish, and the enamel was left exposed. Next, the specimens were immersed in a solution of black tea, which was changed every 24 h, for a period of 6 days. After this period, a photo-reflectance reading was taken (Time 1) with a spectrometer. The stained specimens were then submitted to linear brushing movements (5,000 cycles) using brushes (Oral B-Soft) coupled to an automatic toothbrushing machine, under a static axial load of 200 g and with a speed of 4 movements/second, at 37 degrees C, with the dentifrice or water being injected every 60 s. When toothbrushing ended, a second photo-reflectance reading was taken (Time 2). The results were submitted to two-criteria analysis of variance (ANOVA) and to the Tukey test ( = 0.05). When the two times for a same group were compared, Time 2 presented the highest reflectance values with statistical difference only for G3 and G4. Among the dentifrices tested, only the Rapid White group differed from the control group, presenting the highest reflectance values. Only the whitening dentifrice Rapid White was effective for the removal of extrinsic stains.


Brazilian Oral Research | 2011

Effects of mouthwashes on Knoop hardness and surface roughness of dental composites after different immersion times

Diogo de Azevedo Miranda; Carlos Eduardo dos Santos Bertoldo; Flávio Henrique Baggio Aguiar; Débora Alves Nunes Leite Lima; José Roberto Lovadino

The aim of this in vitro study was to evaluate the effect of different mouthwashes on superficial roughness and Knoop hardness of two resin composites. Eighty specimens (6 mm Ø and 2 mm height) were prepared and divided into eight experimental groups (n = 10) according to the resin composites (4 Seasons and Esthet X), and storage solutions (G1 - Distilled water; G2 - Colgate Plax Overnight; G3 - Colgate Plax Alcohol Free; and G4 - Colgate Plax Whitening). The initial hardness and roughness readings (T1) were measured and then the specimens were stored in 2 mL of mouthwash for 12 h (T2) and 24 h (T3). The data were analyzed with repeat-measures two-way ANOVA and Tukeys test (α = 5%). Regardless of the type of solution and time of exposure, there was no statistical difference for roughness between the resins (p = 0.44). G4 and G8 presented higher roughness means than G1, G3, G5 and G7, after 12 and 24 hours of immersion. For Knoop microhardness analysis, there was a significant reduction for all groups after 12 hours and 24 hours. We conclude that the mouthwashes containing hydrogen peroxide and/or alcohol decrease the microhardness of the resins tested; however, the mouthwash containing hydrogen peroxide had a higher deleterious effect on roughness.


Journal of Dentistry | 2013

Mechanical and physical properties of silorane and methacrylate-based composites

Isabel Cristina Celerino de Moraes Porto; Flávio Henrique Baggio Aguiar; William Cunha Brandt; Priscila Christiane Susy Liporoni

OBJECTIVES This study measured the degree of conversion (DC), sorption, solubility and microhardness of methacrylate (Filtek Z250 and Filtek Z350XT) and silorane-based composites (Filtek P90). METHODS DC was measured using near infrared spectroscopy immediately and 24h after the photoactivation. Sorption and solubility measurements were performed after 24h, 4 weeks and 12 weeks of storage in water. Knoop microhardness was measured after 24h and after thermal cycling. The data were statistically analyzed using ANOVA followed by Tukeys, Tamhane or paired t-tests (α=0.05). RESULTS The DC for P90 (37.22±1.46) was significantly lower than the Z250 (71.44±1.66) and Z350 (71.76±2.84). Water sorption was highest in the Z250 and lowest in the P90. All the tested composites exhibited similar values after 24h of immersion, and no significant differences were observed. No significant differences were observed between the solubilities of the P90 composite (12 weeks) and the Z250 or Z350 composites (4 weeks). KHN values were less elevated for the P90 composite and similar for the Z250 and Z350 composites. An effect of thermal cycling on KHN values was observed for all the composites (p<0.001). CONCLUSIONS Silorane produced the lowest DC and KHN values and exhibited lower water sorption and solubility compared to methacrylate-based composites. These differences suggest that silorane composites exhibit better hydrolytic stability after 3 months of water immersion compared to conventional methacrylate-based composites. CLINICAL SIGNIFICANCE Silorane had higher hydrolytic stability after 3 months of water immersion than the methacrylate-based resins, despite the lower values of DC and KHN recorded.


Journal of The Mechanical Behavior of Biomedical Materials | 2012

Mechanical properties and degree of conversion of etch-and-rinse and self-etch adhesive systems cured by a quartz tungsten halogen lamp and a light-emitting diode.

Lívia Aguilera Gaglianone; Adriano Fonseca Lima; Luciano de Souza Gonçalves; Andrea Nóbrega Cavalcanti; Flávio Henrique Baggio Aguiar; Giselle Maria Marchi

The aim of the present study was to evaluate the degree of conversion (DC), elastic modulus (E), and flexural strength (FS) of five adhesive systems (only the bonding component of both Scotchbond MP-SBMP and Clearfil Protect Bond-CP; Single Bond 2-SB2; One-up Bond F Plus-OUP; and P90 System Adhesive: primer-P90P and bond-P90B) cured with a quartz tungsten halogen (QTH) lamp and a light-emitting diode (LED). Two groups per adhesive were formed (n=5), according to the light source (quartz tungsten halogen-QTH: Demetron LC; and light-emitting diode-LED: UltraLume 5). Bar-shaped specimens were evaluated using three-point bending. The DC was obtained by Fourier transform infrared spectroscopy (FTIR). SB2 and P90P exhibited better DC values for QTH curing. However, SB2 and P90P presented the worst results overall. The light source was statistically significant for all adhesives, except for P90B and OUP. Non-solvated adhesives presented the best E and FS values. It could be concluded that the DC and E values can be influenced by the light source; however, this interference is material dependent.


Operative Dentistry | 2011

Effect of preheating resin composite and light-curing units on the microleakage of Class II restorations submitted to thermocycling.

R. E. Agostinho dos Santos; Adriano Fonseca Lima; Giulliana Panfiglio Soares; Ambrosano Gm; Giselle Maria Marchi; José Roberto Lovadino; Flávio Henrique Baggio Aguiar

This in vitro study evaluated microleakage in Class II cavities restored with dental composite and varying light-curing units and the temperature of the composite when subjected to a thermocycling test. Ninety cavities were prepared on the proximal surfaces of bovine teeth and randomly divided according to the light-curing mode (QTH-420 mW/cm2, LED 2nd generation-1100 mW/cm2, or LED 3rd generation-700 mW/cm2) and temperature of the resin composite (23°C, 54°C and 60°C). Following the restorative procedures and thermocycling, the samples were immersed in methylene blue for 12 hours. The samples were ground and the powder prepared for analysis in an absorbance spectrophotometer. All the results were statistically analyzed using the nonparametric tests of Kruskal-Wallis and Dunn (p ≤ 0.05). The results showed that there was no statistical difference between the light-curing modes at a temperature of 23°C. For 54°C, QTH showed a microleakage mean that was significantly lower than those of the LED groups, and for 60°C, QTH had a microleakage mean significantly lower than that of the LED 2nd generation group. There was no statistical difference between the temperatures of the resin composite when LEDs were used. For QTH, 54°C showed statistically lower microleakage than 23°C. The group preheated to 60°C showed no difference when compared to the group heated to 23°C. Preheating the resin composite (54°C and 60°C) did not improve the microleakage means when high-irradiance LED was used; however, it decreased the microleakage means when a QTH with low irradiance was used.


Journal of Adhesive Dentistry | 2011

Effect of bleaching treatment and reduced application time of an antioxidant on bond strength to bleached enamel and subjacent dentin.

Adriano Fonseca Lima; Fabricio Maurilio da Silva Fonseca; Marcela Santiago Freitas; Alan Rodrigo Muniz Palialol; Flávio Henrique Baggio Aguiar; Giselle Maria Marchi

PURPOSE To evaluate the influence of bleaching on bond strength to enamel and subjacent dentin, and to determine whether a reduced application time (1 min) of the antioxidizing agent can obviate the compromised bond strength after bleaching. MATERIALS AND METHODS One hundred twelve bovine incisors were obtained, and the enamel and dentin surfaces were standardized to a thickness of 1 mm. The specimens were divided into two control groups (enamel and dentin without treatment) and 12 experimental groups (n = 10), based on the concentration of bleaching agents (carbamide peroxide 16% and hydrogen peroxide 35%), time interval between bleaching and restorative procedures (24 h; 24 h + sodium ascorbate (SA) 10%/1 min; 14 days), and substrate (enamel or dentin). All samples were submitted to the bleaching treatment on enamel. After the stipulated interval, a microshear test was performed. RESULTS The bleaching treatment compromised the bond strength to the enamel when the restoration was performed 24 h after the end of bleaching. The bond strength to dentin was not affected by bleaching. CONCLUSIONS The SA 10% application for 1 min obviates the detrimental effect of bleaching on bond strength. The bleaching performed on enamel does not affect the bond strength to the subjacent dentin.


Brazilian Oral Research | 2004

Evaluation of microleakage in human, bovine and swine enamels

Allan Abuabara; Alex José Souza dos Santos; Flávio Henrique Baggio Aguiar; José Roberto Lovadino

The suitability of bovine and swine teeth has been evaluated when they are used as substitutes for extracted human teeth in varied researches. This study evaluated in vitro the marginal microleakage in human, bovine and swine enamel. Cubic cavities (2 x 2 x 2 mm3) were prepared in enamel blocks from human, swine and bovine teeth. The cavities were filled with composite resin and conventional glass-ionomer cement. All the samples were thermocycled for 1,000 cycles (5 +/- 2 degrees C - 55 +/- 2 degrees C) and immersed in 2% methylene blue solution for 12 hours. The microleakage was quantified by a spectrophotometric technique. The results were statistically analyzed using ANOVA and Tukeys test. The glass-ionomer cement presented significantly higher leakage means (microg/ml +/- SD) than the composite resin for all substrates (0.0695 +/- 0.01313 vs. 0.0471 +/- 0.0163, p < 0.01). No significant differences were found between bovine and swine enamel (0.0668 +/- 0.0246 vs. 0.0674 +/- 0.0286); however, both presented statistically higher leakage means than human enamel (0.0407 +/- 0.0195, p < 0.01). It was concluded that the microleakage pattern was affected by substrates, and that bovine and swine substrates allow higher marginal leakage than human substrates. The results indicate there should be precaution in the substitution of human substrate in laboratory studies of microleakage.

Collaboration


Dive into the Flávio Henrique Baggio Aguiar's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Anderson Catelan

State University of Campinas

View shared research outputs
Top Co-Authors

Avatar

Giselle Maria Marchi

State University of Campinas

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Adriano Fonseca Lima

State University of Campinas

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge