Flemming Buus Bendixen
Vestas
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Flemming Buus Bendixen.
power electronics specialists conference | 2004
Flemming Buus Bendixen; Frede Blaabjerg; Peter Omand Rasmussen; Pierre Vadstrup; Kenneth Krabbe
Traditionally electrical motors have three phases, but multiphase motors have shown to improve motor performance and efficiency. This paper concentrates about the control algorithm for a six-phase induction motor with third harmonic current injection. The problem is that typically a seventh inverter branch and filter inductance is needed for stabilizing the midpoint potential of the series connected DC-capacitor link. A new control strategy that pre-calculates the allowed voltage ripple and controls the motor voltage accordingly (using two standard three phase inverter modules) is suggested. With this new control strategy the seventh branch and an inductance can be saved. It also opens the possibility to use two standard three-phase inverters to supply the six-phase motor. An experimental setup is build and the theory is verified in the test case. The proposed control strategy works satisfactory. A drawback is that the voltage ripple in the midpoint increases, if a third harmonic current is injected specially at low speed, which could demand a higher voltage rating of the capacitors. Another drawback is that the higher voltage ripple will stress the capacitors hence the lifetime may be shortened.
international symposium on power electronics electrical drives automation and motion | 2006
Stig Munk-Nielsen; Flemming Buus Bendixen; Hans Chr. Christiansen
Characterization of five accuracy class 0.2 current transformers rated 600 A up to 2500 A is done by measurement of phase displacement and amplitude error as function of frequency and current. The test system is presented and the test procedure is described. The accuracy of test system voltage and current measurements is addressed and separate measurements on the transformer burden (load resistance) are carried using other test equipment. This enables an assessment of the test equipment measurement ability. Finally, measurements of the current error and phase displacement of five different current transformers with burden are carried out
Archive | 2011
Lars Helle; Morten Lindholm; Flemming Buus Bendixen
Archive | 2009
Flemming Buus Bendixen; Gert Karmisholt Andersen; Kim B. Larsen
Archive | 2009
Gert Karmisholt Andersen; Kim B. Larsen; Flemming Buus Bendixen
Archive | 2008
Lars Helle; Philip Carne Kjær; Morten Lindholm; Flemming Buus Bendixen; Ion Boldea
Archive | 2008
Kim B. Larsen; Mogens Lau; Flemming Buus Bendixen
Archive | 2009
Lars Helle; Philip Carne Kjær; Morten Lindholm; Flemming Buus Bendixen; Ion Boldea
Archive | 2013
Lars Helle; Philip Carne Kjær; Morten Lindholm; Flemming Buus Bendixen; Ion Boldea
Archive | 2008
Gert Karmisholt Andersen; Kim B. Larsen; Flemming Buus Bendixen