Frances M. Russell
Indiana University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Frances M. Russell.
Western Journal of Emergency Medicine | 2014
Michael Gottlieb; John Bailitz; Errick Christian; Frances M. Russell; Robert R. Ehrman; Basem F. Khishfe; Alexander Kogan; Christopher Ross
Introduction Recent research has investigated the use of ultrasound (US) for confirming endotracheal tube (ETT) placement with varying techniques, accuracies, and challenges. Our objective was to evaluate the accuracy of a novel, simplified, four-step (4S) technique. Methods We conducted a blinded, randomized trial of the 4S technique utilizing an adult human cadaver model. ETT placement was randomized to tracheal or esophageal location. Three US experts and 45 emergency medicine residents (EMR) performed a total of 150 scans. The primary outcome was the overall sensitivity and specificity of both experts and EMRs to detect location of ETT placement. Secondary outcomes included a priori subgroup comparison of experts and EMRs for thin and obese cadavers, time to detection, and level of operator confidence. Results Experts had a sensitivity of 100% (95% CI = 72% to 100%) and specificity of 100% (95% CI = 77% to 100%) on thin, and a sensitivity of 93% (95% CI = 66% to 100%) and specificity of 100% (95% CI = 75% to 100%) on obese cadavers. EMRs had a sensitivity of 91% (95% CI = 69% to 98%) and of specificity 96% (95% CI = 76% to 100%) on thin, and a sensitivity of 100% (95% CI = 82% to 100%) specificity of 48% (95% CI = 27% to 69%) on obese cadavers. The overall mean time to detection was 17 seconds (95% CI = 13 seconds to 20 seconds, range: 2 to 63 seconds) for US experts and 29 seconds (95% CI = 25 seconds to 33 seconds; range: 6 to 120 seconds) for EMRs. There was a statistically significant decrease in the specificity of this technique on obese cadavers when comparing the EMRs and experts, as well as an increased overall time to detection among the EMRs. Conclusion The simplified 4S technique was accurate and rapid for US experts. Among novices, the 4S technique was accurate in thin, but appears less accurate in obese cadavers. Further studies will determine optimal teaching time and accuracy in emergency department patients.
Pulmonary circulation | 2015
Jeffrey A. Kline; Frances M. Russell; Tim Lahm; Ronald Mastouri
Many dyspneic patients who undergo computerized tomographic pulmonary angiography (CTPA) for presumed acute pulmonary embolism (PE) have no identified cause for their dyspnea yet have persistent symptoms, leading to more CTPA scanning. Right ventricular (RV) dysfunction or overload can signal treatable causes of dyspnea. We report the rate of isolated RV dysfunction or overload after negative CTPA and derive a clinical decision rule (CDR). We performed secondary analysis of a multicenter study of diagnostic accuracy for PE. Inclusion required persistent dyspnea and no PE. Echocardiography was ordered at clinician discretion. A characterization of isolated RV dysfunction or overload required normal left ventricular function and RV hypokinesis, or estimated RV systolic pressure of at least 40 mmHg. The CDR was derived from bivariate analysis of 97 candidate variables, followed by multivariate logistic regression. Of 647 patients, 431 had no PE and persistent dyspnea, and 184 (43%) of these 431 had echocardiography ordered. Of these, 64 patients (35% [95% confidence interval (CI): 28%–42%]) had isolated RV dysfunction or overload, and these patients were significantly more likely to have a repeat CTPA within 90 days (P = .02, χ 2 test). From univariate analysis, 4 variables predicted isolated RV dysfunction: complete right bundle branch block, normal CTPA scan, active malignancy, and CTPA with infiltrate, the last negatively. Logistic regression found only normal CTPA scanning significant. The final rule (persistent dyspnea + normal CTPA scan) had a positive predictive value of 53% (95% CI: 37%–69%). We conclude that a simple CDR consisting of persistent dyspnea plus a normal CTPA scan predicts a high probability of isolated RV dysfunction or overload on echocardiography.
American Journal of Emergency Medicine | 2015
Frances M. Russell; Christopher L. Moore; D. Mark Courtney; Christopher Kabrhel; Howard A. Smithline; Peter B. Richman; Brian J. O'Neil; Michael C. Plewa; Daren M. Beam; Ronald Mastouri; Jeffrey A. Kline
BACKGROUND Many patients have unexplained persistent dyspnea after negative computed tomographic pulmonary angiography (CTPA). We hypothesized that many of these patients have isolated right ventricular (RV) dysfunction from treatable causes. We previously derived a clinical decision rule (CDR) for predicting RV dysfunction consisting of persistent dyspnea and normal CTPA, finding that 53% of CDR-positive patients had isolated RV dysfunction. Our goal is to validate this previously derived CDR by measuring the prevalence of RV dysfunction and outcomes in dyspneic emergency department patients. METHODS A secondary analysis of a prospective observational multicenter study that enrolled patients presenting with suspected PE was performed. We included patients with persistent dyspnea, a nonsignificant CTPA, and formal echo performed. Right ventricular dysfunction was defined as RV hypokinesis and/or dilation with or without moderate to severe tricuspid regurgitation. RESULTS A total of 7940 patients were enrolled. Two thousand six hundred sixteen patients were analyzed after excluding patients without persistent dyspnea and those with a significant finding on CTPA. One hundred ninety eight patients had echocardiography performed as standard care. Of those, 19% (95% confidence interval [CI], 14%-25%) and 33% (95% CI, 25%-42%) exhibited RV dysfunction and isolated RV dysfunction, respectively. Patients with isolated RV dysfunction or overload were more likely than those without RV dysfunction to have a return visit to the emergency department within 45 days for the same complaint (39% vs 18%; 95% CI of the difference, 4%-38%). CONCLUSION This simple clinical prediction rule predicted a 33% prevalence of isolated RV dysfunction or overload. Patients with isolated RV dysfunction had higher recidivism rates and a trend toward worse outcomes.
International Journal of Emergency Medicine | 2018
Yogendra Amatya; Jordan Rupp; Frances M. Russell; Jason Saunders; Brian Bales; Darlene R. House
BackgroundLung ultrasound is an effective tool for diagnosing pneumonia in developed countries. Diagnostic accuracy in resource-limited countries where pneumonia is the leading cause of death is unknown. The objective of this study was to evaluate the sensitivity of bedside lung ultrasound compared to chest X-ray for pneumonia in adults presenting for emergency care in a low-income country.MethodsPatients presenting to the emergency department with suspected pneumonia were evaluated with bedside lung ultrasound, single posterioranterior chest radiograph, and computed tomography (CT). Using CT as the gold standard, the sensitivity of lung ultrasound was compared to chest X-ray for the diagnosis of pneumonia using McNemar’s test for paired samples. Diagnostic characteristics for each test were calculated.ResultsOf 62 patients included in the study, 44 (71%) were diagnosed with pneumonia by CT. Lung ultrasound demonstrated a sensitivity of 91% compared to chest X-ray which had a sensitivity of 73% (p = 0.01). Specificity of lung ultrasound and chest X-ray were 61 and 50% respectively.ConclusionsBedside lung ultrasound demonstrated better sensitivity than chest X-ray for the diagnosis of pneumonia in Nepal.Trial registrationClinicalTrials.gov, registration number NCT02949141. Registered 31 October 2016.
Western Journal of Emergency Medicine | 2018
Daniel Corson-Knowles; Frances M. Russell
Introduction Clinical ultrasound (CUS) is highly specific for the diagnosis of acute appendicitis but is operator-dependent. The goal of this study was to determine if a heterogeneous group of emergency physicians (EP) could diagnose acute appendicitis on CUS in patients with a moderate to high pre-test probability. Methods This was a prospective, observational study of a convenience sample of adult and pediatric patients with suspected appendicitis. Sonographers received a structured, 20-minute CUS training on appendicitis prior to patient enrollment. The presence of a dilated (>6 mm diameter), non-compressible, blind-ending tubular structure was considered a positive study. Non-visualization or indeterminate studies were considered negative. We collected pre-test probability of acute appendicitis based on a 10-point visual analog scale (moderate to high was defined as >3), and confidence in CUS interpretation. The primary objective was measured by comparing CUS findings to surgical pathology and one week follow-up. Results We enrolled 105 patients; 76 had moderate to high pre-test probability. Of these, 24 were children. The rate of appendicitis was 36.8% in those with moderate to high pre-test probability. CUS were recorded by 33 different EPs. The sensitivity, specificity, and positive and negative likelihood ratios of EP-performed CUS in patients with moderate to high pre-test probability were 42.8% (95% confidence interval [CI] [25–62.5%]), 97.9% (95% CI [87.5–99.8%]), 20.7 (95% CI [2.8–149.9]) and 0.58 (95% CI [0.42–0.8]), respectively. The 16 false negative scans were all interpreted as indeterminate. There was one false positive CUS diagnosis; however, the sonographer reported low confidence of 2/10. Conclusion A heterogeneous group of EP sonographers can safely identify acute appendicitis with high specificity in patients with moderate to high pre-test probability. This data adds support for surgical consultation without further imaging beyond CUS in the appropriate clinical setting.
Annals of Emergency Medicine | 2018
Michael Gottlieb; Frances M. Russell
[Ann Emerg Med. 2017;-:1-6.] Editor’s Note: Emergency physicians must often make decisions about patient management without clear-cut data of sufficient quality to support clinical guidelines or evidence-based reviews. Topics in the Best Available Evidence section must be relevant to emergency physicians, are formally peer reviewed, and must have a sufficient literature base to draw a reasonable conclusion but not such a large literature base that a traditional “evidence-based” review, meta-analysis, or systematic review can be performed.
Western Journal of Emergency Medicine | 2017
Michael Gottlieb; Frances M. Russell
Introduction Patients with shoulder dislocations commonly present to the emergency department. Ultrasound has the potential to save time, radiation exposure, healthcare costs, and possible need for re-sedation. We conducted this systematic review to compare the diagnostic accuracy of ultrasound compared with plain radiography in the assessment of shoulder dislocations. Methods We searched PubMed, Scopus, the Cochrane Database of Systematic Reviews, and the Cochrane Central Register of Controlled Trials for relevant trials. Primary data and test characteristics were obtained for all included studies. We used QUADAS-2 to assess study quality. Meta-analysis was not performed due to significant heterogeneity. Results Four studies met our inclusion criteria, comprising 531 assessments with 202 dislocations. Most studies had a sensitivity of 100% for identifying dislocations. One study demonstrated a sensitivity of 54%, and another had only one dislocation that was misidentified. All studies were 100% specific for detecting dislocation. Conclusion Ultrasound may be considered as an alternative diagnostic method for the detection of shoulder dislocation and reduction, but further studies are necessary before routine use.
American Journal of Emergency Medicine | 2017
Frances M. Russell; Jeffrey A. Kline; Tim Lahm
Background Right ventricular (RV) dysfunction and pulmonary hypertension (PH) are commonly unrecognized in the emergency department (ED), but are associated with poor outcomes. Prior research has found a 30% prevalence of isolated RV dysfunction in ED patients after non‐significant computed tomographic pulmonary angiography (CTPA). We aimed to prospectively define the prevalence of RV dysfunction and/or PH in short of breath ED patients, and assess outcomes. Methods Prospective observational study of patients with a non‐significant CTPA. Isolated RV dysfunction and/or PH was defined as normal left ventricular function plus RV dilation, moderate to severe tricuspid regurgitation or RV systolic pressure > 40 mm Hg on comprehensive echocardiography. Results Of 83 patients, 20 (24%, 95% [confidence interval] CI: 16–34%) had isolated RV dysfunction and/or PH. These patients had 40% ED recidivism and 30% hospital readmission at 30‐days. When compared to patients with normal echocardiographic function, they had significantly longer intensive care unit and hospital length of stays. Conclusions In a prospective cohort of ED patients, we found a high prevalence of isolated RV dysfunction and/or PH after a non‐significant CTPA. These patients had high rates of recidivism and hospital readmission. This data supports a continued need for ED based screening and specialty referral.
Academic Emergency Medicine | 2017
Matt A. Rutz; Julie M. Clary; Jeffrey A. Kline; Frances M. Russell
OBJECTIVE Focused cardiac ultrasound (FOCUS) is a useful tool in evaluating patients presenting to the emergency department (ED) with acute dyspnea. Prior work has shown that right ventricular (RV) dilation is associated with repeat hospitalizations and shorter life expectancy. Traditionally, RV assessment has been evaluated by cardiologist-interpreted comprehensive echocardiography. The primary goal of this study was to determine the inter-rater reliability between emergency physicians (EPs) and a cardiologist for determining RV dilation on FOCUS performed on ED patients with acute dyspnea. METHODS This was a prospective, observational study at two urban academic EDs; patients were enrolled if they had acute dyspnea and a computed tomographic pulmonary angiogram without acute disease. All patients had an EP-performed FOCUS to assess for RV dilation. RV dilation was defined as an RV to left ventricular ratio greater than 1. FOCUS interpretations were compared to a blinded cardiologist FOCUS interpretation using agreement and kappa statistics. RESULTS Of 84 FOCUS examinations performed on 83 patients, 17% had RV dilation. Agreement and kappa, for EP-performed FOCUS for RV dilation were 89% (95% confidence interval [CI] 80-95%) and 0.68 (95% CI 0.48-0.88), respectively. CONCLUSIONS Emergency physician sonographers are able to detect RV dilation with good agreement when compared to cardiology. These results support the wider use of EP-performed FOCUS to evaluate for RV dilation in ED patients with dyspnea.
Academic Emergency Medicine | 2015
Frances M. Russell; Robert R. Ehrman; Karen S. Cosby; Asim Ansari; Stephanie Tseeng; Errick Christain; John Bailitz