Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Frances S. Ligler is active.

Publication


Featured researches published by Frances S. Ligler.


Analytical Chemistry | 1999

An array immunosensor for simultaneous detection of clinical analytes

Chris A. Rowe; Stephanie B. Scruggs; Mark J. Feldstein; Joel P. Golden; Frances S. Ligler

A fluorescence-based immunosensor has been developed for simultaneous analysis of multiple samples. A patterned array of recognition elements immobilized on the surface of a planar waveguide is used to capture analyte present in samples; bound analyte is then quantified by means of fluorescent detector molecules. Upon excitation of the fluorescent label by a small diode laser, a CCD camera detects the pattern of fluorescent antigen:antibody complexes on the sensor surface. Image analysis software correlates the position of fluorescent signals with the identity of the analyte. This immunosensor was used to detect physiologically relevant concentrations of staphylococcal enterotoxin B (SEB), F1 antigen from Yersinia pestis, and D-dimer, a marker of sepsis and thrombotic disorders, in spiked clinical samples.


Proceedings of the National Academy of Sciences of the United States of America | 2015

Microneedle-array patches loaded with hypoxia-sensitive vesicles provide fast glucose-responsive insulin delivery

Jicheng Yu; Yuqi Zhang; Yanqi Ye; Rocco DiSanto; Wujin Sun; Davis Ranson; Frances S. Ligler; John B. Buse; Zhen Gu

Significance For exploiting synthetic glucose-responsive insulin delivery systems, challenges remain to demonstrate a strategy that would combine (i) fast responsiveness, (ii) ease of administration, and (iii) excellent biocompatibility. We have developed a novel glucose-responsive insulin delivery device using a painless microneedle-array patch containing hypoxia-sensitive hyaluronic acid-based vesicles. The vesicles quickly dissociate and release encapsulated insulin under the local hypoxic environment, caused by the enzymatic oxidation of glucose in the hyperglycemic state. This “smart insulin patch” with a new enzyme-based glucose-responsive mechanism can regulate the blood glucose of type 1 diabetic mice to achieve normal levels, with faster responsiveness compared with the commonly used pH-sensitive formulations, and can avoid the risk of hypoglycemia. A glucose-responsive “closed-loop” insulin delivery system mimicking the function of pancreatic cells has tremendous potential to improve quality of life and health in diabetics. Here, we report a novel glucose-responsive insulin delivery device using a painless microneedle-array patch (“smart insulin patch”) containing glucose-responsive vesicles (GRVs; with an average diameter of 118 nm), which are loaded with insulin and glucose oxidase (GOx) enzyme. The GRVs are self-assembled from hypoxia-sensitive hyaluronic acid (HS-HA) conjugated with 2-nitroimidazole (NI), a hydrophobic component that can be converted to hydrophilic 2-aminoimidazoles through bioreduction under hypoxic conditions. The local hypoxic microenvironment caused by the enzymatic oxidation of glucose in the hyperglycemic state promotes the reduction of HS-HA, which rapidly triggers the dissociation of vesicles and subsequent release of insulin. The smart insulin patch effectively regulated the blood glucose in a mouse model of chemically induced type 1 diabetes. The described work is the first demonstration, to our knowledge, of a synthetic glucose-responsive device using a hypoxia trigger for regulation of insulin release. The faster responsiveness of this approach holds promise in avoiding hyperglycemia and hypoglycemia if translated for human therapy.


Analytical Chemistry | 2009

Perspective on Optical Biosensors and Integrated Sensor Systems

Frances S. Ligler

Optical biosensors have begun to move from the laboratory to the point of use. This trend will be accelerated by new concepts for molecular recognition, integration of microfluidics and optics, simplified fabrication technologies, improved approaches to biosensor system integration, and dramatically increased awareness of the applicability of sensor technology to improve public health and environmental monitoring. Examples of innovations are identified that will lead to smaller, faster, cheaper optical biosensor systems with capacity to provide effective and actionable information.


Analytical Chemistry | 2009

Multiplexed detection of bacteria and toxins using a microflow cytometer.

Jason S. Kim; George P. Anderson; Jeffrey S. Erickson; Joel P. Golden; Mansoor Nasir; Frances S. Ligler

A microfabricated flow cytometer was used to demonstrate multiplexed detection of bacteria and toxins using fluorescent coded microspheres. Antibody-coated microspheres bound biothreat targets in a sandwich immunoassay format. The microfluidic cytometer focused the microspheres in three dimensions within the laser interrogation region using passive groove structures to surround the sample stream with sheath fluid. Optical analysis at four different wavelengths identified the coded microspheres and quantified target bound by the presence of phycoerythrin tracer. The multiplexed assays in the microflow cytometer had performance approaching that of a commercial benchtop flow cytometer. The respective limits of detection for bacteria (Escherichia coli, Listeria, and Salmonella) were found to be 10(3), 10(5), and 10(4) cfu/mL for the microflow cytometer and 10(3), 10(6), and 10(5) cfu/mL for the commercial system. Limits of detection for the toxins (cholera toxin, staphylococcal enterotoxin B, and ricin) were 1.6, 0.064, and 1.6 ng/mL for the microflow cytometer and 1.6, 0.064, and 8.0 ng/mL for the commercial system.


Nature Communications | 2015

Transformable liquid-metal nanomedicine

Yue Lu; Quanyin Hu; Yiliang Lin; Dennis B. Pacardo; Chao Wang; Wujin Sun; Frances S. Ligler; Michael D. Dickey; Zhen Gu

To date, numerous inorganic nanocarriers have been explored for drug delivery systems (DDSs). However, the clinical application of inorganic formulations has often been hindered by their toxicity and failure to biodegrade. We describe here a transformable liquid-metal nanomedicine, based on a core–shell nanosphere composed of a liquid-phase eutectic gallium-indium core and a thiolated polymeric shell. This formulation can be simply produced through a sonication-mediated method with bioconjugation flexibility. The resulting nanoparticles loaded with doxorubicin (Dox) have an average diameter of 107u2009nm and demonstrate the capability to fuse and subsequently degrade under a mildly acidic condition, which facilitates release of Dox in acidic endosomes after cellular internalization. Equipped with hyaluronic acid, a tumour-targeting ligand, this formulation displays enhanced chemotherapeutic inhibition towards the xenograft tumour-bearing mice. This liquid metal-based DDS with fusible and degradable behaviour under physiological conditions provides a new strategy for engineering theranostic agents with low toxicity.


Applied and Environmental Microbiology | 2004

Detection of Salmonella enterica Serovar Typhimurium by Using a Rapid, Array-Based Immunosensor

Chris R. Taitt; Yura S. Shubin; Roselina Angel; Frances S. Ligler

ABSTRACT The multianalyte array biosensor (MAAB) is a rapid analysis instrument capable of detecting multiple analytes simultaneously. Rapid (15-min), single-analyte sandwich immunoassays were developed for the detection of Salmonella enterica serovar Typhimurium, with a detection limit of 8 × 104 CFU/ml; the limit of detection was improved 10-fold by lengthening the assay protocol to 1 h. S. enterica serovar Typhimurium was also detected in the following spiked foodstuffs, with minimal sample preparation: sausage, cantaloupe, whole liquid egg, alfalfa sprouts, and chicken carcass rinse. Cross-reactivity tests were performed with Escherichia coli and Campylobacter jejuni. To determine whether the MAAB has potential as a screening tool for the diagnosis of asymptomatic Salmonella infection of poultry, chicken excretal samples from a private, noncommercial farm and from university poultry facilities were tested. While the private farm excreta gave rise to signals significantly above the buffer blanks, none of the university samples tested positive for S. enterica serovar Typhimurium without spiking; dose-response curves of spiked excretal samples from university-raised poultry gave limits of detection of 8 × 103 CFU/g.


Applied and Environmental Microbiology | 2005

Biosensor Detection of Botulinum Toxoid A and Staphylococcal Enterotoxin B in Food

Kim E. Sapsford; Chris R. Taitt; Nicole Loo; Frances S. Ligler

ABSTRACT Immunoassays were developed for the simultaneous detection of staphylococcal enterotoxin B and botulinum toxoid A in buffer, with limits of detection of 0.1 ng/ml and 20 ng/ml, respectively. The toxins were also spiked and measured in a variety of food samples, including canned tomatoes, sweet corn, green beans, mushrooms, and tuna.


IEEE Transactions on Biomedical Engineering | 1994

An evanescent wave biosensor. II. Fluorescent signal acquisition from tapered fiber optic probes

Joel P. Golden; George P. Anderson; Sina Y. Rabbany; Frances S. Ligler

For pt.I see ibid., vol.41, no.6, p.578-84 (1994). A biosensor was developed using antibodies, fluorescence and the evanescent wave to detect antigen binding at the surface of an optical fiber. Cladding was removed from the core along the distal end of a step-index optical fiber, and recognition antibodies were immobilized on the declad core to form the probe sensing region. Immersing the declad probe in aqueous solution creates a V-number mismatch between the immersed probe and the clad fiber. Probes created with reduced sensing region radius exhibited improved response by decreasing the V-number mismatch. Tapering the radius of this region has further improved probe response. Ray tracing analysis of the tapered probe demonstrated that the evanescent wave penetration depth increases along the length of the taper. Experiments correlating position of refraction along the taper with launch angle at the proximal end were realized in the ray tracing model. An evanescent wave immunoassay was performed with a series of the tapered fiber probes, each tapered from the fiber core radius (100 /spl mu/m) to different end radii. An end radius of 29 /spl mu/m was found to produce maximal signal from the tapered probe. Factors leading to the determination of the optimized probe are discussed.<<ETX>>


Advanced Healthcare Materials | 2015

Microfluidic strategies for design and assembly of microfibers and nanofibers with tissue engineering and regenerative medicine applications.

Michael A. Daniele; Darryl A. Boyd; André A. Adams; Frances S. Ligler

Fiber-based materials provide critical capabilities for biomedical applications. Microfluidic fiber fabrication has recently emerged as a very promising route to the synthesis of polymeric fibers at the micro and nanoscale, providing fine control over fiber shape, size, chemical anisotropy, and biological activity. This Progress Report summarizes advanced microfluidic methods for the fabrication of both microscale and nanoscale fibers and illustrates how different methods are enabling new biomedical applications. Microfluidic fabrication methods and resultant materials are explained from the perspective of their microfluidic device principles, including co-flow, cross-flow, and flow-shaping designs. It is then detailed how the microchannel design and flow parameters influence the variety of synthesis chemistries that can be utilized. Finally, the integration of biomaterials and microfluidic strategies is discussed to manufacture unique fiber-based systems, including cell scaffolds, cell encapsulation, and woven tissue matrices.


Journal of Food Protection | 2003

Detection of Staphylococcal Enterotoxin B in Spiked Food Samples

Lisa C. Shriver-Lake; Yura S. Shubin; Frances S. Ligler

Contamination of food with infectious agents, intentional or not, is a global concern with far-reaching economic and social impact. Staphylococcal enterotoxins are a major cause of food poisoning, but most methods for the identification of these agents in food require extensive pretreatment or concentration of the sample prior to analysis. The array biosensor was developed as a portable device for the simultaneous analysis of multiple complex samples for multiple targets with minimal sample preparation. In this study, we use an array biosensor to expand and improve on a staphylococcal enterotoxin B (SEB) assay with the ultimate intent of incorporating testing for SEB into a battery of sensitive and convenient assays for food safety validation. In addition to buffer studies, six different types of food samples, including beverages, homogenates of fruit and meat, and carcass washings, were spiked with SEB, incubated for at least 2 h to permit antigen sequestration, and assayed. For all samples, there were differences in fluorescence intensity, but 0.5 ng of SEB per ml could be detected in <20 min with little if any pretreatment and no sample preconcentration.

Collaboration


Dive into the Frances S. Ligler's collaboration.

Top Co-Authors

Avatar

Lisa C. Shriver-Lake

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

Chris R. Taitt

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

Zhen Gu

University of North Carolina at Chapel Hill

View shared research outputs
Top Co-Authors

Avatar

Michael A. Daniele

North Carolina State University

View shared research outputs
Top Co-Authors

Avatar

Dennis B. Pacardo

University of North Carolina at Chapel Hill

View shared research outputs
Top Co-Authors

Avatar

André A. Adams

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

Darryl A. Boyd

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

George P. Anderson

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

Joel P. Golden

United States Naval Research Laboratory

View shared research outputs
Top Co-Authors

Avatar

Anne W. Kusterbeck

United States Naval Research Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge