Journal of Tribology-transactions of The Asme | 2013

Wear Simulation of Metal-on-Metal Hip Replacements With Frictional Contact

Lorenza Mattei; Francesca Di Puccio

Preclinical wear evaluation is extremely important in hip replacements, wear being one of the main causes of failure. Experimental tests are attractive but highly cost demanding; thus predictive models have been proposed in the literature, mainly based on finite element simulations. In such simulations, the effect of friction is usually disregarded, as it is considered not to affect the contact pressure distribution. However, a frictional contact could also result in a shift of the location of the nominal contact area, which can thus modify the wear maps. The aim of this study is to investigate this effect in wear prediction for metal-on-metal implants. Wear assessment was based on a purpose-developed mathematical model, extension of a previous one proposed by the same authors for metal-on-plastic implants. The innovative aspect of the present study consists in the implementation of a modified location of the nominal contact point due to friction, which takes advantage of the analytical formulation of the wear model. Simulations were carried out aimed at comparing total and resurfacing hip replacements under several gait conditions. The results highlighted that the adoption of a frictional contact yields lower linear wear rates and wider worn areas, while for the adopted friction coefficient (f=0.2), the total wear volume remains almost unchanged. The comparison between total and resurfacing replacements showed higher scaled wear volumes (wear volume divided by wear factor) for the latter, in agreement with the literature. The effect of the boundary conditions (in vivo versus in vitro) was also investigated remarking their influence on implant wear and the need to apply more physiological-like conditions in hip simulators. In conclusion although friction is usually neglected in numerical wear predictions, as it does not affect markedly the contact pressure distribution, its effect in the location of the theoretical contact point was observed to influence wear maps. This achievement could be useful for increasing the correlation between numerical and experimental simulations, usually based on the total wear volume. In order to improve the model reliability, future studies will be devoted to implement the geometry update by combining the present model to finite element analyses. On the other hand, further experimental investigations are required to get out from the wide dispersion of wear factors reported in the literature.


Progress in Electromagnetics Research M | 2012

A Self-Controlled Maglev System

Francesca Di Puccio; Antonino Musolino; Rocco Rizzo; Ernesto Tripodi

This paper presents a MAGLEV system in which the magnetic suspension is assured by the repulsion of permanent magnets both on the guideway and on the vehicle. Due to the induced currents on a aluminum sheath surrounding the magnets on the guideway, the system intrinsic instability is overcome. The detailed structure of the proposed system is described and the main results of the simulations by means a FE code are reported.


Journal of Biomechanical Engineering-transactions of The Asme | 2011

Advances in Finite Element Simulations of Elastosonography for Breast Lesion Detection

Simona Celi; Francesca Di Puccio; Paola Forte

Among the available tools for the early diagnosis of breast cancer, the elastographic technique based on ultrasounds has many advantages such as the noninvasive measure, the absence of ionizing effects, the high tolerability by patients, and the wide diffusion of the ecographic machines. However this diagnostic procedure is strongly affected by many subjective factors and is considered not reliable enough even to reduce the number of biopsies used to identify the nature of lesions. Therefore in the literature experimental and numerical simulations on physical and virtual phantoms are presented to test and validate procedures and algorithms and to interpret elastosonographic results. In this work, first a description of the elastographic technique and a review of the principal finite element (FE) models are provided and second diagnostic indexes employed to assess the nature of a lump mass are presented. As advances in FE simulations of elastosonography, axisymmetric phantom, and anthropomorphic models are described, which, with respect to the literature, include some features of breast mechanics. In particular deterministic analyses were used to compare the various details of virtual elastograms and also to investigate diagnostic indexes with respect to the regions where strains were considered. In order to improve the reliability of the elastosonographic procedure, univariate and multivariate sensitivity analyses, based on a probabilistic FE approach, were also performed to identify the parameters that mostly influence the deformation contrast between healthy and cancerous tissues. Moreover, synthetic indicators of the strain field, such as the strain contrast coefficient, were evaluated in different regions of interest in order to identify the most suitable for lesion type assessment. The deterministic analyses show that the malignant lesion is characterized by a uniform strain inside the inclusion due to the firmly bonding condition, while in the benign inclusion (loosely bonded) a strain gradient is observed independently from the elastic modulus contrast. The multivariate analyses reveal that the strain contrast depends linearly on the relative stiffness between the lesion and the healthy tissue and not linearly on the interface friction coefficient. The anthropomorphic model shows other interesting features, such as the layer or curvature effects, which introduce difficulties in selecting a reference region for strain assessment. The results show that a simple axisymmetric model with linear elastic material properties can be suitable to simulate the elastosonographic procedure although the breast curvature and layer distinction play a significant role in the strain assessment.


Journal of Vascular Access | 2016

A comparative study on the mechanical behavior of polyurethane PICCs.

Paolo Poli; Antonella Scocca; Francesca Di Puccio; Giuseppe Carmine Gallone; Lorenza Angelini; Emanuele Maria Calabrò

Purpose This study describes a comparative analysis of eight commercial polyurethane, single-lumen peripherally inserted central venous catheters (PICCs) from different vendors. The aim was to investigate the mechanical response of the catheters providing objective and quantitative data to support a comparison among them. Such data could help nurses and physicians to select a central venous catheter (CVC) not only on the basis of the expected dwell duration or of the assessment of the vessels at the desired insertion site but also of the chemical and mechanical properties of the CVC and of the projected response of the body to these properties. Methods An experimental procedure was defined and tests were performed to assess some main characteristics of the PICC lines, including macro and microgeometric features, chemical and physical properties, and mechanical response. Preliminary measurements were performed to accurately define all geometric characteristics, including length, inner and outer diameters, and any inherent initial curvature of the catheter. Micro-geometric features were investigated using surface roughness analysis, optical microscopy, and scanning electron microscopy. Mechanical properties were studied by means of dynamic mechanical thermal analysis, simple uniaxial tensile tests, and kinking tests. Results Results are discussed in order to compare the different PICC lines. In particular, they show that polyurethane catheters can have a different mechanical behavior, which might play a role in the onset of pathologic processes and result in an increased risk and incidence of catheter-related complications. Conclusions This study provides useful information that can help identifying and facilitate the choice of a PICC.


Journal of The Mechanical Behavior of Biomedical Materials | 2016

Numerical and experimental investigations for the evaluation of the wear coefficient of reverse total shoulder prostheses

Lorenza Mattei; Francesca Di Puccio; T. J. Joyce; Enrico Ciulli

In the present study, numerical and experimental wear investigations on reverse total shoulder arthroplasties (RTSAs) were combined in order to estimate specific wear coefficients, currently not available in the literature. A wear model previously developed by the authors for metal-on-plastic hip implants was adapted to RTSAs and applied in a double direction: firstly, to evaluate specific wear coefficients for RTSAs from experimental results and secondly, to predict wear distribution. In both cases, the Archard wear law (AR) and the wear law of UHMWPE (PE) were considered, assuming four different k functions. The results indicated that both the wear laws predict higher wear coefficients for RTSA with respect to hip implants, particularly the AR law, with k values higher than twofold the hip ones. Such differences can significantly affect predictive wear model results for RTSA, when non-specific wear coefficients are used. Moreover, the wear maps simulated with the two laws are markedly different, although providing the same wear volume. A higher wear depth (+51%) is obtained with the AR law, located at the dome of the cup, while with the PE law the most worn region is close to the edge. Taking advantage of the linear trend of experimental volume losses, the wear coefficients obtained with the AR law should be valid despite having neglected the geometry update in the model.


Journal of The Mechanical Behavior of Biomedical Materials | 2016

Effect of size and dimensional tolerance of reverse total shoulder arthroplasty on wear: An in-silico study

Lorenza Mattei; Francesca Di Puccio; T. J. Joyce; Enrico Ciulli

Although huge research efforts have been devoted to wear analysis of ultra-high molecular weight polyethylene (UHMWPE) in hip and knee implants, shoulder prostheses have been studied only marginally. Recently, the authors presented a numerical wear model of reverse total shoulder arthroplasties (RTSAs), and its application for estimating the wear coefficient k from experimental data according to different wear laws. In this study, such model and k expressions are exploited to investigate the sensitivity of UHMWPE wear to implant size and dimensional tolerance. A set of 10 different geometries was analysed, considering nominal diameters in the range 36-42mm, available on the market, and a cup dimensional tolerance of +0.2, -0.0mm (resulting in a diametrical clearance ranging between 0.04-0.24mm), estimated from measurements on RTSAs. Since the most reliable wear law and wear coefficient k for UHMWPE are still controversial in the literature, both the Archard law (AR) and the wear law of UHMWPE (PE), as well as four different k expressions were considered, carrying out a total of 40 simulations. Results showed that the wear volume increases with the implant size and decreases with the dimensional tolerance for both the wear laws. Interestingly, different trends were obtained for the maximum wear depth vs. clearance: the best performing implants should have a high conformity according to the AR law but low conformity for the PE law. However, according to both laws, wear is highly affected by both implant size and dimensional tolerance, although it is much more sensitive to the latter, with up to a twofold variation of wear predicted. Indeed, dimensional tolerance directly alters the clearance, and therefore the lubrication and contact pressure distribution in the implant. Rather surprisingly the role of dimensional tolerance has been completely disregarded in the literature, as well as in the standards. Furthermore, this study notes some important issues for future work, such as the validation of wear laws and predictive wear models and the sensitivity of k to implant geometry.


Volume 4: Advanced Manufacturing Processes; Biomedical Engineering; Multiscale Mechanics of Biological Tissues; Sciences, Engineering and Education; Multiphysics; Emerging Technologies for Inspection | 2012

Wear simulation of metal on metal hip replacements: an analytical approach

Lorenza Mattei; Francesca Di Puccio; Enrico Ciulli

Hip replacement failure is mainly attributable to the implant wear. Consequently preclinical wear evaluations are extremely important. As experimental tests are attractive but highly cost/time demanding, several predictive models have been proposed mainly based on finite element simulations and for metal on plastic (MoP) implants. The aim of this study is to develop a mathematical wear model of metal on metal prostheses, revision of the previous one for MoP implants, developed by the same authors. The model, based on the Archard wear law and on the Hertzian theory, was applied to compare a total (THR) and a resurfacing (RHR) hip replacement under both in vivo and in vitro gait conditions. The results were in agreement with the literature predicting wear rates significantly higher for the RHR than for the THR. The effect of the boundary conditions on wear rates/maps was also investigated and the model limitations discussed.Copyright


Shock and Vibration | 2004

Identification of the 3D Vibratory Motion of a Rigid Body by Accelerometer Measurements

Francesca Di Puccio; Paola Forte

The identification of the motion of a rigid body by means of linear accelerometers is a problem already investigated by many researchers, but still debated. The optimisation of the number and placement of accelerometers is also another important aspect of the problem. In this study, an experimental procedure is proposed and applied to identify the rigid-body vibratory motion of the steering wheel of a sporting car, by means of six linear accelerometers. Some numerical simulations for investigating possible errors are also presented.


Journal of Biomechanics | 2017

Spinal loads and trunk muscles forces during level walking - A combined in vivo and in silico study on six subjects

Rizwan Arshad; Lorenza Angelini; Thomas Zander; Francesca Di Puccio; Marwan El-Rich; Hendrik Schmidt

During level walking, lumbar spine is subjected to cyclic movements and intricate loading of the spinal discs and trunk musculature. This study aimed to estimate the spinal loads (T12-S1) and trunk muscles forces during a complete gait cycle. Six men, 24-33years walk barefoot at self-selected speed (4-5km/h). 3D kinematics and ground reaction forces were recorded using a motion capturing system and two force plates, implemented in an inverse dynamic musculoskeletal model to predict the spinal loads and trunk muscles forces. Additionally, the sensitivity of the intra-abdominal pressure and lumbar segment rotational stiffness was investigated. Peak spinal loads and trunk muscle forces were between the gait instances of heel strike and toe off. In L4-L5 segment, sensitivity analysis showed that average peak compressive, antero-posterior and medio-lateral shear forces were 130-179%, 2-15% and 1-6%, with max standard deviation (±STD) of 40%, 6% and 3% of the body weight. Average peak global muscles forces were 24-55% (longissimus thoracis), 11-23% (iliocostalis thoracis), 12-16% (external oblique), 17-25% (internal oblique) and 0-8% (rectus abdominus) of body weight whereas, the average peak local muscles forces were 11-19% (longissimus lumborum), 14-31% (iliocostalis lumborum) and 12-17% (multifidus). Maximum±STD of the global and local muscles forces were 13% and 8% of the body weight. Large inter-individual differences were found in peak compressive and trunk muscles forces whereas the sensitivity analysis also showed a substantial variation.


Annals of Biomedical Engineering | 2017

Vibration Testing Procedures for Bone Stiffness Assessment in Fractures Treated with External Fixation

Lorenza Mattei; Antonia Longo; Francesca Di Puccio; Enrico Ciulli; Stefano Marchetti

A bone healing assessment is crucial for the successful treatment of fractures, particularly in terms of the timing of support devices. However, in clinical practice, this assessment is only made qualitatively through bone manipulation and X-rays, and hence cannot be repeated as often as might be required. The present study reconsiders the quantitative method of frequency response analysis for healing assessments, and specifically for fractures treated with an external fixator. The novelty consists in the fact that bone excitation and response are achieved through fixator pins, thus overcoming the problem of transmission through soft-tissues and their damping effect. The main objective was to develop and validate a test procedure in order to characterize the treated bone. More than 80 tests were performed on a tibia phantom alone, a phantom with pins, and a phantom with a complete fixator. Different excitation techniques and input–output combinations were compared. The results demonstrated the effectiveness of a procedure based on impact tests using a micro-hammer. Pins and fixator were demonstrated to influence the frequency response of the phantom by increasing the number of resonant frequencies. This procedure will be applied in future studies to monitor healing both in in vitro and in vivo conditions.

Collaboration


Dive into the Francesca Di Puccio's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Simona Celi

National Research Council

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge