Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where François Grosjean is active.

Publication


Featured researches published by François Grosjean.


ASME 2012 31st International Conference on Ocean, Offshore and Arctic Engineering | 2012

Qualification of Unbonded Dynamic Riser With Carbon Fiber Composite Armours

Anaïs Lambert; Anh-Tuan Do; Antoine Felix-Henry; François Grosjean

The development of Ultra Deep Water (UDW) oil and gas fields, down to 3000 m and beyond, requires high specification flowline and riser systems. At these depths, the flexible pipes must withstand high axial loads and severe dynamic loadings generated by currents, waves and vessel motions. Moreover, the constraints generated by the dynamic loadings are often combined to corrosion issues linked to the presence of CO2 and H2S. In case of sour service application, the structural layers of a classical flexible pipe require the use of steel with reduced mechanical properties compared to a sweet service application. The combination of UDW and sour service applications consequently lead to a riser design of considerable top tension.The main challenges of such applications are the suspended weight and the fatigue / corrosion performances.Carbon fiber composite have demonstrated high specific strength and outstanding corrosion and fatigue damage resistance. The use of carbon fiber composite instead of conventional steel for the tensile armour layers of flexible pipes represents a great alternative for the development of UDW applications combined with sour service conditions.Technip has been engaged for a number of years in the development and qualification program of Carbon Fiber Composite (CFC) Armour. In 2011, an important step has been passed with the successful realization of a full-scale tension-flexion dynamic test.The program of the full-scale dynamic test is based on a representative Brazilian offshore project, a typical UDW application. The CFC prototype structure was designed considering a 9” gas export riser installed at a water depth of 2140m, in free hanging configuration. The riser is made of 2 parts: a top riser with CFC armours and a bottom riser with steel armours.1.8 millions of cycles were performed without damage, combining internal pressure, tensile loading and bending cycling. The whole test was monitored by acoustic emission to detect the potential damage of the CFC armours.After explaining the advantages of CFC structures compared to traditional steel structures, the paper will focus on the realization of the full-scale dynamic test program. It will detail the design and manufacture of the prototype structure, the construction of the test program representative of the offshore conditions first and then extended to more severe loadings. The paper will also present fatigue analysis and the construction of the CFC fatigue curves.© 2012 ASME


Corrosion Science | 2013

Corrosion mechanisms in aqueous solutions containing dissolved H2S. Part 1: Characterisation of H2S reduction on a 316L rotating disc electrode.

Jean Kittel; F. Ropital; François Grosjean; Eliane Sutter; Bernard Tribollet


Electrochimica Acta | 2014

Corrosion mechanisms in aqueous solutions containing dissolved H2S. Part 2: Model of the cathodic reactions on a 316L stainless steel rotating disc electrode

Bernard Tribollet; Jean Kittel; A. Meroufel; F. Ropital; François Grosjean; Eliane Sutter


Corrosion Science | 2012

Reversible catastrophic oxidation of a 38Fe–34Ni–25Cr alloy induced by sodium sulphate at low oxygen potential atmospheres

L. Couture; F. Ropital; François Grosjean; Jean Kittel; Valérie Parry; Y. Wouters


Oxidation of Metals | 2013

Influence of the Oxygen Partial Pressure on the High Temperature Corrosion of 38Ni–34Fe–25Cr Alloy in Presence of NaCl Deposit

L. Couture; F. Ropital; François Grosjean; Jean Kittel; Valérie Parry; Y. Wouters


Spectra analyse | 2011

Couplage analyse thermogravimétrique et émission acoustique pour l'étude de la corrosion haute température

François Grosjean; Jean Kittel; Francois Ropital; Eric Serris; Véronique Peres


Sensor Letters | 2014

Thermogravimetric experiments coupled with acoustic emission analysis dedicated to high-temperature corrosion studies

Omar Al Haj; Véronique Peres; Eric Serris; François Grosjean; Jean Kittel; Francois Ropital; Michel Cournil


Matériaux 2014 | 2014

Sur l'apport de l’émission acoustique couplée à l’analyse thermogravimétrique pour la compréhension de la corrosion du fer par metal dusting.

Omar Al Haj; Véronique Peres; Eric Serris; François Grosjean; Jean Kittel; Francois Ropital; Michel Cournil


Fontevraud 8 - Contribution of Materials Investigations and Operating Experience to LWRs’ Safety, Performance and Reliability | 2014

Contribution of in situ acoustic emission analysis coupled with thermogravimetry to study zirconium alloy oxidation

Omar Al Haj; Véronique Peres; Eric Serris; François Grosjean; Jean Kittel; Francois Ropital; Michel Cournil


31<sup>st</sup> Conference of the European Working Group on Acoustic Emission (EWGAE) | 2014

Acoustic emission analysis coupled with thermogravimetric experiments dedicated to high temperature corrosion studies on metallic alloys

Eric Serris; Omar Al Haj; Jean Kittel; Véronique Peres; François Grosjean; Francois Ropital; Michel Cournil

Collaboration


Dive into the François Grosjean's collaboration.

Top Co-Authors

Avatar

Véronique Peres

École Normale Supérieure

View shared research outputs
Top Co-Authors

Avatar

Eliane Sutter

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar

Valérie Parry

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar

Y. Wouters

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Eric Serris

Ecole nationale supérieure des mines de Saint-Étienne

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge