Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where François Saucy is active.

Publication


Featured researches published by François Saucy.


Nephrology Dialysis Transplantation | 2010

Is intra-operative blood flow predictive for early failure of radiocephalic arteriovenous fistula?

François Saucy; Erik Haesler; Claude Haller; Sébastien Déglise; Daniel Teta; Jean-Marc Corpataux

BACKGROUND For over 50 years, radiocephalic wrist arteriovenous fistulae (RCAVF) have been the primary and best vascular access for haemodialysis. Nevertheless, early failure due to thrombosis or non-maturation is a major complication resulting in their abandonment. This prospective study was designed to investigate the predictive value of intra-operative blood flow on early failure of primary RCAVF before the first effective dialysis. METHODS We enrolled patients undergoing creation of primary RCAVF for haemodialysis based on the pre-operative ultrasound vascular mapping discussed in a multidisciplinary approach. Intra-operative blood flow measurement was systematically performed once the anastomosis had been completed using a transit-time ultrasonic flowmeter. During the follow-up, blood flow was estimated by colour flow ultrasound at various intervals. Any events related to the RCAVF were recorded. RESULTS Autogenous RCAVFs (n = 58) in 58 patients were constructed and followed up for an average of 30 days. Thrombosis and non-maturation occurred in eight (14%) and four (7%) patients, respectively. The intra-operative blood flow in functioning RCAVFs was significantly higher compared to non-functioning RCAVFs (230 vs 98 mL/min; P = 0.007), as well as 1 week (753 vs 228 mL/min; P = 0.0008) and 4 weeks (915 vs 245 mL/min, P < 0.0001) later. Blood flow volume measurements with a cut-off value of 120 mL/min had a sensitivity of 67%, specificity of 75% and positive predictive value of 91%. CONCLUSIONS Blood flow <120 mL has a good predictive value for early failure in RCAVF. During the procedure, this cut-off value may be used to select appropriately which RCAVF should be investigated in the operation theatre in order to correct in real time any abnormality.


Journal of Vascular Surgery | 2013

Role of hemodynamic forces in the ex vivo arterialization of human saphenous veins.

Xavier Berard; Sébastien Déglise; Florian Alonso; François Saucy; Paolo Meda; Laurence Bordenave; Jean-Marc Corpataux; Jacques-Antoine Haefliger

BACKGROUND Human saphenous vein grafts are one of the salvage bypass conduits when endovascular procedures are not feasible or fail. Understanding the remodeling process that venous grafts undergo during exposure to arterial conditions is crucial to improve their patency, which is often compromised by intimal hyperplasia. The precise role of hemodynamic forces such as shear stress and arterial pressure in this remodeling is not fully characterized. The aim of this study was to determine the involvement of arterial shear stress and pressure on vein wall remodeling and to unravel the underlying molecular mechanisms. METHODS An ex vivo vein support system was modified for chronic (up to 1 week), pulsatile perfusion of human saphenous veins under controlled conditions that permitted the separate control of arterial shear stress and different arterial pressure (7 mm Hg or 70 mm Hg). RESULTS Veins perfused for 7 days under high pressure (70 mm Hg) underwent significant development of a neointima compared with veins exposed to low pressure (7 mm Hg). These structural changes were associated with altered expression of several molecular markers. Exposure to an arterial shear stress under low pressure increased the expression of matrix metalloproteinase (MMP)-2 and MMP-9 and tissue inhibitor of metalloproteinase (TIMP)-1 at the transcript, protein, and activity levels. This increase was enhanced by high pressure, which also increased TIMP-2 protein expression despite decreased levels of the cognate transcript. In contrast, the expression of plasminogen activator inhibitor-1 increased with shear stress but was not modified by pressure. Levels of the venous marker Eph-B4 were decreased under arterial shear stress, and levels of the arterial marker Ephrin-B2 were downregulated under high-pressure conditions. CONCLUSIONS This model is a valuable tool to identify the role of hemodynamic forces and to decipher the molecular mechanisms leading to failure of human saphenous vein grafts. Under ex vivo conditions, arterial perfusion is sufficient to activate the remodeling of human veins, a change that is associated with the loss of specific vein markers. Elevation of pressure generates intimal hyperplasia, even though veins do not acquire arterial markers. CLINICAL RELEVANCE The pathological remodeling of the venous wall, which leads to stenosis and ultimately graft failure, is the main limiting factor of human saphenous vein graft bypass. This remodeling is due to the hemodynamic adaptation of the vein to the arterial environment and cannot be prevented by conventional therapy. To develop a more targeted therapy, a better understanding of the molecular mechanisms involved in intimal hyperplasia is essential, which requires the development of ex vivo models of chronic perfusion of human veins.


Biomaterials | 2014

The use of external mesh reinforcement to reduce intimal hyperplasia and preserve the structure of human saphenous veins

Alban Longchamp; Florian Alonso; Céline Dubuis; Florent Allagnat; Xavier Berard; Paolo Meda; François Saucy; Jean-Marc Corpataux; Sébastien Déglise; Jacques-Antoine Haefliger

The saphenous vein is the conduit of choice in bypass graft procedures. Haemodynamic factors play a major role in the development of intimal hyperplasia (IH), and subsequent bypass failure. To evaluate the potential protective effect of external reinforcement on such a failure, we developed an ex vivo model for the perfusion of segments of human saphenous veins under arterial shear stress. In veins submitted to pulsatile high pressure (mean pressure at 100 mmHg) for 3 or 7 days, the use of an external macroporous polyester mesh 1) prevented the dilatation of the vessel, 2) decreased the development of IH, 3) reduced the apoptosis of smooth muscle cells, and the subsequent fibrosis of the media layer, 4) prevented the remodelling of extracellular matrix through the up-regulation of matrix metalloproteinases (MMP-2, MMP-9) and plasminogen activator type I. The data show that, in an experimental ex vivo setting, an external scaffold decreases IH and maintains the integrity of veins exposed to arterial pressure, via increase in shear stress and decrease wall tension, that likely contribute to trigger selective molecular and cellular changes.


Journal of Pharmacology and Experimental Therapeutics | 2013

Atorvastatin-loaded hydrogel affects the smooth muscle cells of human veins.

Céline Dubuis; Laurence May; Florian Alonso; Ludmila Luca; Ioanna Mylonaki; Paolo Meda; Florence Delie; Olivier Jordan; Sébastien Déglise; Jean-Marc Corpataux; François Saucy; Jacques-Antoine Haefliger

Intimal hyperplasia (IH) is the major cause of stenosis of vein grafts. Drugs such as statins prevent stenosis, but their systemic administration has limited effects. We developed a hyaluronic acid hydrogel matrix, which ensures a controlled release of atorvastatin (ATV) at the site of injury. The release kinetics demonstrated that 100% of ATV was released over 10 hours, independent of the loading concentration of the hydrogel. We investigated the effects of such a delivery on primary vascular smooth muscle cells isolated from human veins. ATV decreased the proliferation, migration, and passage of human smooth muscle cells (HSMCs) across a matrix barrier in a similar dose-dependent (5–10 µM) and time-dependent manner (24–72 hours), whether the drug was directly added to the culture medium or released from the hydrogel. Expression analysis of genes known to be involved in the development of IH demonstrated that the transcripts of both the gap junction protein connexin43 (Cx43) and plasminogen activator inhibitor-1 (PAI-1) were decreased after a 24–48-hour exposure to the hydrogel loaded with ATV, whereas the transcripts of the heme oxygenase (HO-1) and the inhibitor of tissue plasminogen activator were increased. At the protein level, Cx43, PAI-1, and metalloproteinase-9 expression were decreased, whereas HO-1 was upregulated in the presence of ATV. The data demonstrate that ATV released from a hydrogel has effects on HSMCs similar to the drug being freely dissolved in the environment.


European Journal of Vascular and Endovascular Surgery | 2012

Infrainguinal bypass for peripheral arterial occlusive disease: when arms save legs.

F. Vauclair; Claude Haller; Pedro Marques-Vidal; Sébastien Déglise; Erik Haesler; Jean Marc Corpataux; François Saucy

OBJECTIVES Determine if arm veins are good conduits for infrainguinal revascularisation and should be used when good quality saphenous vein is not available. DESIGN Retrospective study. MATERIALS AND METHODS We evaluated a consecutive series of infrainguinal bypass (IB) using arm vein conduits from March 2001 to December 2006.We selected arm vein by preoperative ultrasound mapping to identify suitable veins. We measured vein diameter and assessed vein wall quality. We followed patients with systematic duplex imaging at 1 week, 1, 3, 6 and 12 months, and annually thereafter. We treated significative stenoses found during the follow-up. RESULTS We performed 56 infrainguinal revascularisation using arm vein conduits in 56 patients. Primary patency rates at 1, 2 and 3 years were 65%, 51% and 47%. Primary assisted patencies at 1, 2 and 3 years were 96%, 96% and 82%. Secondary patency rates at 1, 2 and 3 years were 92%, 88% and 88%. The three-year limb salvage rate was 88%. CONCLUSIONS We conclude that infrainguinal bypass using arm vein for conduits gives good patency rates, if selected by a preoperative US mapping to use the best autogenous conduit available.


Journal of Controlled Release | 2016

Perivascular sustained release of atorvastatin from a hydrogel-microparticle delivery system decreases intimal hyperplasia

Ioanna Mylonaki; Francesco Strano; Sébastien Déglise; Eric Allémann; Florian Alonso; Jean-Marc Corpataux; Céline Dubuis; Jacques-Antoine Haefliger; Olivier Jordan; François Saucy; Florence Delie

Intimal hyperplasia (IH) is the major cause of grafted vessel occlusion and occurs frequently after bypass intervention. No pharmaceutical formulation is currently available to prevent this pathology. Local perivascular delivery of an appropriate active compound released in a time-dependent manner (from day one up to 4weeks) is necessary for an efficient single-administration preventive therapy. To this aim, we propose the combination of gel and microparticles delivery system containing atorvastatin (ATV). The incorporation of ATV in a cross-linked hyaluronic acid gel, provided in vitro a fast release over 3days, while ATV-loaded poly-lactic-co-glycolic acid (PLGA) microparticles dispersed in the gel gave a sustained release over 4weeks. In vivo, ATV formulations were applied perivascularly in mice undergoing carotid artery ligation. IH was significantly reduced (-68%) in presence of ATV incorporated in hyaluronic acid gel and encapsulated in microparticles compared to control. No significant IH alteration was observed when ATV was incorporated only in the gel (fast release) or only in the microparticles (slow release) demonstrating that a biphasic release of ATV is essential to interfere with the development of IH. ATV was detected in adjacent tissues 28days after the intervention, showing the sustained presence of the drug in vivo. After four weeks ATV was not detected in remote tissues, except at a very low concentration (0.044ng/mg) in the liver, suggesting a very low risk of systemic toxicity of locally delivered ATV. Additionally, the ex vivo data showed that ATV in solution permeates through isolated human saphenous veins and thus is a good candidate for perivascular delivery. Our data demonstrate that a local biphasic ATV release on the mice ligated carotid efficiently prevents the development of IH without apparent toxicity.


Annals of Vascular Surgery | 2011

Current management of true aneurysm of the dorsalis pedis artery.

Xavier Berard; Rodolphe Bodin; François Saucy; Sébastien Déglise; André Pailler; Dominique Midy; Jean-Marc Corpataux

We describe two cases of true dorsalis pedis artery aneurysms in men referred for pulsatile mass of the dorsal part of the foot. Both aneurysms were resected and grafted with interposition of a short segment of saphenous vein. Histological analysis showed true aneurysm associated with atherosclerosis. To our knowledge, only 12 cases of true dorsalis pedis artery aneurysm have been reported previously. On the basis of our experience and after reviewing the literature, the management of this uncommon pathology was discussed.


Biomaterials | 2017

Perivascular medical devices and drug delivery systems: Making the right choices

Ioanna Mylonaki; Eric Allémann; François Saucy; Jacques-Antoine Haefliger; Florence Delie; Olivier Jordan

Perivascular medical devices and perivascular drug delivery systems are conceived for local application around a blood vessel during open vascular surgery. These systems provide mechanical support and/or pharmacological activity for the prevention of intimal hyperplasia following vessel injury. Despite abundant reports in the literature and numerous clinical trials, no efficient perivascular treatment is available. In this review, the existing perivascular medical devices and perivascular drug delivery systems, such as polymeric gels, meshes, sheaths, wraps, matrices, and metal meshes, are jointly evaluated. The key criteria for the design of an ideal perivascular system are identified. Perivascular treatments should have mechanical specifications that ensure system localization, prolonged retention and adequate vascular constriction. From the data gathered, it appears that a drug is necessary to increase the efficacy of these systems. As such, the release kinetics of pharmacological agents should match the development of the pathology. A successful perivascular system must combine these optimized pharmacological and mechanical properties to be efficient.


Current Pharmaceutical Design | 2015

Abdominal Aortic Aneurysm: What About Screening?

François Saucy; Sébastien Déglise; Thomas Holzer; Lukas Briner; Marie Benezit; Charline Delay; Caroline Kazandjian; Jean-Marc Corpataux

The prevalence of abdominal aortic aneurysm (AAA) in general population is 4-9% with a high mortality rate when ruptured. Therefore, screening programs were developed in many countries to detect small and large AAA in selected patients. Indeed, prevalence of AAA increases in patients over 65 years old with cigarette smoking history. This paper reviews recent literature related to AAA screening focusing on epidemiology, screening tests and evidence based medicine to highlight not only advantages but also disadvantages of screening programs among population.


Journal of Vascular Access | 2016

Early cannulation of the Flixene™ arteriovenous graft

Nicolas Ottaviani; Sébastien Déglise; Vincenzo Brizzi; Eric Ducasse; Dominique Midy; Claire Rigothier; François Saucy; Xavier Berard

Purpose The aim of this review was to search for evidence of the efficiency of early cannulation of the Flixene™ (Maquet-Atrium Medical, Hudson, NH, USA) arteriovenous graft (AVG) in the current literature and to assess its patency and complication rates. Methods Searches in Pubmed, Medline, Embase and the Cochrane Library were performed using the following specific search terms: early cannulation AVG and/or Flixene™ graft. The primary outcomes were mean time to first cannulation and patency rates at 12 months. Secondary outcomes were complications. Results Six studies reporting outcomes in a total of 260 procedures were included in this review. The median delay from intervention to first cannulation was documented in four studies and was less than 3 days. Primary assisted patency at 12 months ranged from 45% to 53% in the four documented series. In five studies, documented secondary patency at 12 months ranged from 63% to 92%. Two studies compared outcomes between traditional and Flixene™ grafts: one study reported significantly (p<0.01) improved one-year patency using the Flixene™ graft, the two studies did not report significant differences in complication rates between both groups. The rate of infection and pseudo-aneurysm formation ranged from 0 to 11% and 0 to 6%, respectively. Conclusions This review shows that early cannulation of the Flixene™ graft within 3 days following its implantation is feasible with one-year patency and complication rates equivalent to those of conventional grafts which can be cannulated only after 2 weeks.

Collaboration


Dive into the François Saucy's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge