Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Franz Kralinger is active.

Publication


Featured researches published by Franz Kralinger.


Journal of Bone and Joint Surgery-british Volume | 2009

The medial periosteal hinge, a key structure in fractures of the proximal humerus: A BIOMECHANICAL CADAVER STUDY OF ITS MECHANICAL PROPERTIES

Franz Kralinger; S. Unger; Markus Wambacher; V. Smekal; Werner Schmoelz

The medial periosteal hinge plays a key role in fractures of the head of the humerus, offering mechanical support during and after reduction and maintaining perfusion of the head by the vessels in the posteromedial periosteum. We have investigated the biomechanical properties of the medial periosteum in fractures of the proximal humerus using a standard model in 20 fresh-frozen cadaver specimens comparable in age, gender and bone mineral density. After creating the fracture, we displaced the humeral head medial or lateral to the shaft with controlled force until complete disruption of the posteromedial periosteum was recorded. As the quality of periosteum might be affected by age and bone quality, the results were correlated with the age and the local bone mineral density of the specimens measured with quantitative CT. Periosteal rupture started at a mean displacement of 2.96 mm (SD 2.92) with a mean load of 100.9 N (SD 47.1). The mean maximum load of 111.4 N (SD 42.5) was reached at a mean displacement of 4.9 mm (SD 4.2). The periosteum was completely ruptured at a mean displacement of 34.4 mm (SD 11.1). There was no significant difference in the mean distance to complete rupture for medial (mean 35.8 mm (SD 13.8)) or lateral (mean 33.0 mm (SD 8.2)) displacement (p = 0.589). The mean bone mineral density was 0.111 g/cm(3) (SD 0.035). A statistically significant but low correlation between bone mineral density and the maximum load uptake (r = 0.475, p = 0.034) was observed. This study showed that the posteromedial hinge is a mechanical structure capable of providing support for percutaneous reduction and stabilisation of a fracture by ligamentotaxis. Periosteal rupture started at a mean of about 3 mm and was completed by a mean displacement of just under 35 mm. The microvascular situation of the rupturing periosteum cannot be investigated with the current model.


Injury-international Journal of The Care of The Injured | 2011

Elastic stable intramedullary nailing is best for mid-shaft clavicular fractures without comminution: Results in 60 patients

V. Smekal; Alexander Irenberger; Rene El Attal; Dietmar Krappinger; Franz Kralinger

INTRODUCTION Elastic stable intramedullary nailing (ESIN) of displaced mid-shaft clavicular fractures is a minimally invasive technique which was reported to be an easy procedure with low complication rates, good cosmetic and functional results, restoration of clavicular length and fast return to daily activities. Recent studies, however, also report on higher complication rates and specific problems with the use of this technique. This prospective study compares ESIN with non-operative treatment of displaced mid-shaft clavicular fractures. METHODS Between December 2003 and August 2007, 120 patients volunteered to participate. Of these, 112 patients completed the study (60 in the operative and 52 in the non-operative group). Patients in the non-operative group were treated with a simple shoulder sling. In the operative group, intramedullary stabilisation was performed within 3 days of the trauma. Clavicular shortening was determined after trauma and after osseous consolidation on thorax posteroanterior radiographs as the proportional length difference between the left and right side with the uninjured side serving as a control for clavicular length (100%). Radiographic union was assessed every 4 weeks on 20 degrees cephalad anteroposterior and posteroanterior radiographs of the clavicle. Constant shoulder scores and DASH scores (DASH, disabilities of the arm, shoulder and hand) were assessed at final follow-up after 2 years. RESULTS ESIN led to faster osseous healing and better restoration of clavicular length in simple fractures. We were not able to restore clavicular length in comminuted fractures using ESIN. Functional outcome at a mean follow-up of 24 months (range: 22-27 months) was better in the operative group. Delayed union and non-union accounted for the majority of complications in the non-operative group. In the operative group, telescoping was the main complication, which occurred in complex fractures with severe post-traumatic shortening only. CONCLUSION We recommend ESIN for all simple displaced mid-shaft clavicular fractures in order to minimise the rate of delayed union, non-union and symptomatic mal-union. We also recommend ESIN in comminuted fractures with moderate (< or = 7%) post-traumatic shortening, as they will heal with moderate shortening. In comminuted fractures with severe shortening, however, we recommend plate osteosynthesis in order to provide for stability, clavicular length and endosteal blood supply.


Arthroscopy | 2011

A Randomized Study of the Effectiveness of Suprascapular Nerve Block in Patient Satisfaction and Outcome After Arthroscopic Subacromial Decompression

Hans-Christian Jeske; Franz Kralinger; Markus Wambacher; Florian Perwanger; Rebecca Schoepf; Dietmar Krappinger; Christian Dallapozza; Frank Hoffmann

PURPOSE The purpose of this study was to evaluate the efficiency of the suprascapular nerve (SSN) block in pain reduction after arthroscopic subacromial decompression operations and its influence on patient satisfaction. Furthermore, we wanted to evaluate whether better perioperative pain management could positively influence postoperative shoulder function. METHODS In this prospective, randomized, double-blinded clinical trial, 3 groups of patients--each with 15 participants--were treated with SSN block (10 mL of 1% ropivacaine), placebo, or a subacromial infiltration of local anesthesia (20 mL of 1% ropivacaine). Preoperative and postoperative pain was evaluated with a visual analog scale. Functional outcome was measured by the Constant-Murley score, and patient satisfaction was measured anecdotally by interview 2 days, 2 weeks, and 6 weeks after surgery. RESULTS The SSN group reported significantly lower levels of postoperative pain, required significantly less analgesia, had better range of motion, and had higher levels of postoperative satisfaction in comparison to the subacromial infiltration group and placebo group. CONCLUSIONS Patients treated with SSN blocks had less pain overall, which led to a decreased need for analgesics in comparison to the subacromial infiltration and placebo groups. Furthermore, patients in the SSN-blocked group achieved better postoperative ROM and were significantly more satisfied after surgery.


Archives of Orthopaedic and Trauma Surgery | 2016

The relevance of neutral arm positioning for true ap-view X-ray to provide true projection of the humeral head shaft angle

Clemens Hengg; Peter Mayrhofer; Simon A. Euler; Markus Wambacher; Michael Blauth; Franz Kralinger

IntroductionTextbooks commonly recommend using the true anterior–posterior (ap)-view with the patient’s arm in a sling and therefore in internal rotation (IR) for radiologic diagnostic assessment of the proximal humerus after trauma. However, IR or external rotation (ER) may affect the projection of the head shaft angle (HSA) and therefore bias the diagnostic conclusion significantly. We hypothesized that neutral rotation (NR) of the arm is mandatory for true ap-view to provide true projection of the HSA.Materials and methodsA simplified geometrical model of the proximal humerus was used to examine the influence of different arm positions and angulations of the central ray in relation to the projection of the HSA.ResultsBoth ER and IR misleadingly suggested an increased valgus angle. Simulating the true ap-view with the central ray in cranio-caudal direction, IR changed the projection of the HSA substantially.ConclusionIn conclusion, standard fixation of the patient’s arm in a shoulder sling in IR for true ap-view may result in an oblique projection, potentially leading to incorrect surgical implications. To prevent misdiagnosed valgus or varus angulation, NR of the arm should be obeyed when performing true ap-view X-ray. We, therefore, highly recommend to overcome the traditionally arm position, ensuring the true amount of dislocation to assure correct surgical implications and comparable follow-up examinations.


Archives of Orthopaedic and Trauma Surgery | 2006

Bifocal disruption of the knee extensor apparatus ("floating patella") in a 13-year-old patient.

Burkhart Huber; M. Reichenkendler; M. Gschwentner; Franz Kralinger

We present the unusual case of a traumatic “floating patella” in a 13-year-old healthy boy. No predisposing factors were diagnosed. The obvious bony avulsion was treated by immediate open reduction and screwing, whereas the quadriceps tendon rupture was missed diagnostically in the first step. During the course of the treatment, the extension lag lead to the delayed diagnosis of the concomitant rupture of the quadriceps tendon. After the surgical treatment of the latter, the patient healed with full function of the extensor apparatus and full ROM. Bifocal injury of the knee extensor apparatus is therefore possible in young adolescents without presenting the predisposing factors and should thus be considered.


Archives of Orthopaedic and Trauma Surgery | 2008

Reply letter to the editor regarding the biomechanical evaluation of semirigid implants

Franz Kralinger; M. Gschwentner; Markus Wambacher; V. Smekal; C. Haid

Dear Editor, The setup for this selective testing of implants was chosen for two reasons. First, we wanted to compare our results with those of an existing study which had tested the LCPPH using the same setup [1]. Second, we believe that this selective setup is the most appropriate one to reveal the biomechanical performance of implants on the proximal humerus. As stated, we do think that there are fracture situations with interfragmentary ligamentotaxis that are relatively stable after reduction. This is the type of fracture that was treated traditionally with percutaneous pins or more recently with the Humerus Block with good results. These fracture situations are not the subject of our study. In our testing, the IMC showed the lowest stiVness in all cases of load. Subsequently, throughout cyclic testing, it failed to maintain even the initially modest stiVness and showed the greatest loss in load reduction. Therefore, we concluded that it appears highly questionable that the IMC should be capable of stabilizing complex, highly unstable situations without interfragmentary ligamentotaxis. In an ethic commission approved prospective randomised clinical trial testing IMC versus HB, we treated severely dislocated isolated two-part (subcapital) proximal humerus fractures. Inclusion criteria were dislocation of more than half of the width of the shaft or an angulation of more than 45° between the head and the shaft fragment. Patients were randomly assigned to one of the two implants. In both groups all patients were female; mean age was comparable in both groups (70 years IMC/ 68 years HB). In this series of largely geriatric fractures (with concomitant poor bone quality), the IMC was not capable of Wxing the intraoperatively impacted fracture site in an acceptable position until healing had occurred. We stopped the study because of the high rate of severe complications of the IMC implant. About 60% of the IMC treated patients suVered severe, implant-related complications. To sum up, the IMC implant may work in relatively stable subcapital fractures with intact ligamentotaxis and little displacement. These fractures, according to our protocol, are mostly treated nonoperatively. However, in unstable situations with the aforementioned criteria, we failed to demonstrate suYcient holding strength of the implant as well in the biomechnical setup as in the clinical situation.


Injury-international Journal of The Care of The Injured | 2011

Predicting failure after surgical fixation of proximal humerus fractures.

Dietmar Krappinger; Nicola Bizzotto; Stephan Riedmann; C. Kammerlander; Clemens Hengg; Franz Kralinger


Arthroscopy | 2006

Is the Bare Spot a Consistent Landmark for Shoulder Arthroscopy? A Study of 20 Embalmed Glenoids With 3-Dimensional Computed Tomographic Reconstruction

Franz Kralinger; Felix Aigner; Stefano Longato; Michael Rieger; Markus Wambacher


Skeletal Radiology | 2012

Preoperative assessment of the cancellous bone mineral density of the proximal humerus using CT data

Dietmar Krappinger; T. Roth; M. Gschwentner; Armin Suckert; Michael Blauth; Clemens Hengg; Franz Kralinger


Surgical and Radiologic Anatomy | 2004

Anatomical considerations regarding the “bare spot” of the glenoid cavity

F. Aigner; S. Longato; Helga Fritsch; Franz Kralinger

Collaboration


Dive into the Franz Kralinger's collaboration.

Top Co-Authors

Avatar

Markus Wambacher

Innsbruck Medical University

View shared research outputs
Top Co-Authors

Avatar

Dietmar Krappinger

Innsbruck Medical University

View shared research outputs
Top Co-Authors

Avatar

V. Smekal

Innsbruck Medical University

View shared research outputs
Top Co-Authors

Avatar

Clemens Hengg

Innsbruck Medical University

View shared research outputs
Top Co-Authors

Avatar

M. Gschwentner

Innsbruck Medical University

View shared research outputs
Top Co-Authors

Avatar

Christian Dallapozza

Innsbruck Medical University

View shared research outputs
Top Co-Authors

Avatar

Hans-Christian Jeske

Innsbruck Medical University

View shared research outputs
Top Co-Authors

Avatar

Michael Blauth

Innsbruck Medical University

View shared research outputs
Top Co-Authors

Avatar

Rene El Attal

Innsbruck Medical University

View shared research outputs
Top Co-Authors

Avatar

T. Roth

Innsbruck Medical University

View shared research outputs
Researchain Logo
Decentralizing Knowledge