Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Franz Watzinger is active.

Publication


Featured researches published by Franz Watzinger.


International Journal of Radiation Oncology Biology Physics | 2001

Impact of hemoglobin level and use of recombinant erythropoietin on efficacy of preoperative chemoradiation therapy for squamous cell carcinoma of the oral cavity and oropharynx

Christoph Glaser; Werner Millesi; Gabriela Kornek; Susanna Lang; Birgit Schüll; Franz Watzinger; Edgar Selzer; Robert S. Lavey

PURPOSE We assessed the influence of hemoglobin level and r-HuEPO administration on response to chemoradiotherapy, locoregional tumor control, and overall survival in patients treated with neoadjuvant chemoradiotherapy and surgery for a squamous cell carcinoma of the oral cavity or oropharynx. METHODS AND MATERIALS The 191 study patients were treated with mitomycin C (15 mg/m(2) day 1), 5-fluorouracil (750 mg/m(2)/day, days 1-5), and radiotherapy (50 Gy in 25 fractions weeks 1-5), followed by resection of the primary tumor bed and neck dissection at the General Hospital Vienna, Austria, between November 1989 and October 1998 for a T2-4, N0-3, M0 SCC of the oral cavity or oropharynx. Starting in May 1996, patients with a low hemoglobin (Hgb) before or during chemoradiotherapy received r-HuEPO 10,000 IU/kg s.c. 3-6 times/week until the week of surgery. RESULTS On multivariate analysis, Hgb level and use of r-HuEPO were independent prognostic factors for response to chemoradiotherapy and locoregional tumor control (p < 0.01). Pathologic response to neoadjuvant therapy was also predictive of locoregional control (p < 0.001). Patients with a pretreatment Hgb > or = 14.5 g/dL had significantly higher complete response, locoregional control, and survival rates than the patients with a pretreatment Hgb < 14.5 g/dL who did not receive r-HuEPO (p < 0.05). The response, control, and survival rates in patients with a pretreatment Hgb < 14.5 g/dL given r-HuEPO were significantly higher than in low Hgb patients not given r-HuEPO (p < or = 0.001) and equivalent to patients with a pretreatment Hgb > 14.5 g/dL (p > or = 0.3). CONCLUSION Low pretreatment Hgb is a negative prognostic factor for oral cavity and oropharyngeal SCCA patients, but was completely abrogated by r-HuEpo administration during neoadjuvant chemoradiotherapy. Randomized trials of radiation and/or chemotherapy with or without r-HuEPO for patients whose Hgb level is either low at the start of therapy or is anticipated to become low during therapy are indicated.


IEEE Transactions on Medical Imaging | 1998

Calibration of tracking systems in a surgical environment

Wolfgang Birkfellner; Franz Watzinger; Felix Wanschitz; Rolf Ewers; Helmar Bergmann

The purpose of this paper was to assess to what extent an optical tracking system (OTS) used for position determination in computer-aided surgery (CAS) can be enhanced by combining it with a direct current (DC) driven electromagnetic tracking system (EMTS). The main advantage of the EMTS is the fact that it is not dependent on a free line-of-sight. Unfortunately, the accuracy of the EMTS is highly affected by nearby ferromagnetic materials. The authors have explored to what extent the influence of the metallic equipment in the operating room (OR) can be compensated by collecting precise information on the nonlinear local error in the EMTS by using the OTS for setting up a calibration look-up table. After calibration of the EMTS and registration of the sensor systems in the OR the authors have found the average euclidean deviation in position readings between the DC tracker and the OTS reduced from 2.9/spl plusmn/1.0 mm to 2.1/spl plusmn/0.8 mm within a half-sphere of 530-mm radius around the magnetic field emitter. Furthermore the authors have found the calibration to be stable after re-registration of the sensors under varying conditions such as different heights of the OR table and varying positions of the OR equipment over a longer time interval. These results encourage the further development of a hybrid magnetooptical tracker for computer-aided surgery where the electromagnetic tracker acts as an auxiliary source of position information for the optical system. Strategies for enhancing the reliability of the proposed hybrid magnetooptic tracker by detecting artifacts induced by mobile ferromagnetic objects such as surgical tools are discussed.


IEEE Transactions on Medical Imaging | 2002

A head-mounted operating binocular for augmented reality visualization in medicine - design and initial evaluation

Wolfgang Birkfellner; Michael Figl; Klaus Huber; Franz Watzinger; Felix Wanschitz; Johann Hummel; Rudolf Hanel; Wolfgang Greimel; Peter Homolka; Rolf Ewers; Helmar Bergmann

Computer-aided surgery (CAS), the intraoperative application of biomedical visualization techniques, appears to be one of the most promising fields of application for augmented reality (AR), the display of additional computer-generated graphics over a real-world scene. Typically a device such as a head-mounted display (HMD) is used for AR. However, considerable technical problems connected with AR have limited the intraoperative application of HMDs up to now. One of the difficulties in using HMDs is the requirement for a common optical focal plane for both the realworld scene and the computer-generated image, and acceptance of the HMD by the user in a surgical environment. In order to increase the clinical acceptance of AR, we have adapted the Varioscope (Life Optics, Vienna), a miniature, cost-effective head-mounted operating binocular, for AR. In this paper, we present the basic design of the modified HMD, and the method and results of an extensive laboratory study for photogrammetric calibration of the Varioscopes computer displays to a real-world scene. In a series of 16 calibrations with varying zoom factors and object distances, mean calibration error was found to be 1.24 /spl plusmn/ 0.38 pixels or 0.12 /spl plusmn/ 0.05 mm for a 640 /spl times/ 480 display. Maximum error accounted for 3.33 /spl plusmn/ 1.04 pixels or 0.33 /spl plusmn/ 0.12 mm. The location of a position measurement probe of an optical tracking system was transformed to the display with an error of less than 1 mm in the real world in 56% of all cases. For the remaining cases, error was below 2 mm. We conclude that the accuracy achieved in our experiments is sufficient for a wide range of CAS applications.


The Cleft Palate-Craniofacial Journal | 2005

Evaluation of esthetic, functional, and quality-of-life outcome in adult cleft lip and palate patients

Klaus Sinko; Reinhold Jagsch; Franz Watzinger; Karl Hollmann; Arnulf Baumann

Objective Evaluation of esthetic, functional, and health-related quality-of-life (HRQoL) outcomes in adult patients with a repaired cleft lip and palate. The treatment for all patients was based on the so-called Vienna concept. Patients/Design Seventy adult patients with a repaired complete cleft lip and palate, ranging in age from 18 to 30 years, were included in the study. Esthetic and functional outcomes were assessed by the patients themselves and by five experts using a visual analog scale. Patients also completed the MOS Short-Form 36 questionnaire to evaluate health-related quality of life. Results Patients rated their esthetic outcome significantly worse than the experts did. No significant differences were observed in the ratings for function. Female patients, especially, were dissatisfied with their esthetic outcomes. In a personal interview, nearly 63% of them asked for further treatment, particularly for upper-lip and nose corrections. The health-related quality-of-life questionnaire revealed low scores for only two subscales, namely social functioning and emotional role. In most subscales of health-related quality of life, patients who desired further treatment had significantly lower scores than did patients who desired no further treatment. Conclusion Surgery of the lip and nose appears to be of prime importance for patients with a cleft lip and palate. Cleft patients who do not request secondary treatment are not always satisfied with the treatment. Patients with realistic expectations in regard to further treatment should be treated by specialists, whereas those with unrealistic expectations should be referred to a clinical psychologist.


Journal of Cranio-maxillofacial Surgery | 1997

Computer-aided navigation in secondary reconstruction of post-traumatic deformities of the zygoma

Franz Watzinger; Felix Wanschitz; Arne Wagner; G. Enislidis; W. Millesi; A. Baumann; Rolf Ewers

Augmented reality technology was used in 5 patients for secondary reconstruction of post-traumatic unilateral deformities of the zygomaticomaxillary complex. Three electromagnetic sensors interfaced to a computer-aided navigation system (ARTMA Biomedical Inc.) were utilized. The computer navigation procedure was planned by drawing graphic lines on the CT scan at the level of the zygomatic arch, representing the outer surface of the zygoma. The desired position of the displaced zygoma was planned by mirroring from the healthy side, using a virtual mid-sagittal plane. These virtual graphics were presented intraoperatively on a TV monitor and also on the surgeons see-through head-mounted display. Correct reduction was assumed when the virtual line representing the position of the zygoma before the osteotomy reached the virtual line defined preoperatively as the desired position. The advantages of the technique presented are that a complete exposure of the zygomatic bone is no longer necessary, and coronal and subciliary incisions may be avoided unless enophthalmos correction has to be carried out, which was in fact necessary in 2 patients. The results of zygomatic reconstruction have been satisfactory in all 5 patients.


Journal of Cranio-maxillofacial Surgery | 1999

Positioning of dental implants using computer-aided navigation and an optical tracking system: case report and presentation of a new method

Franz Watzinger; Wolfgang Birkfellner; Felix Wanschitz; W. Millesi; Christian Schopper; Klaus Sinko; Klaus Huber; Helmar Bergmann; Rolf Ewers

A navigation system for computer-aided surgery (Virtual Patient System, VPS) has been described in previous studies for different indications in oral and maxillofacial surgery. The aim of the system is the intraoperative transfer of preoperative planning on radiographs or CT scans on the patient, in real-time, and independent of the position of the patients head. Until now an electromagnetic tracking system has been used for intra-operative position measurement. For placement of dental implants, the electromagnetic tracking system is not suitable since the motor of the implant drill leads to a considerable distortion of the magnetic field, thus direct visualization of drilling the implant socket was not possible. To overcome this problem, an optical tracking system which is not disturbed by conductive materials was integrated in the VPS system. The first patient operated on with this system had a posttraumatic loss of the upper incisors; three implants have been placed according to the prosthetic axis previously planned on radiographs and CT scans. The experience gained in this intervention led to the conclusion that computer-aided surgery provides a valuable tool in implant dentistry.


Head and Neck-journal for The Sciences and Specialties of The Head and Neck | 2008

TREATMENT RESULTS OF BISPHOSPHONATE-RELATED OSTEONECROSIS OF THE JAWS

Arno Wutzl; Edwin Biedermann; Felix Wanschitz; Rudolf Seemann; Clemens Klug; Arnulf Baumann; Franz Watzinger; Kurt Schicho; Rolf Ewers; G. Millesi

Osteonecrosis of the jaws occurs after the administration of bisphosphonates. An unequivocal treatment strategy is yet to be devised. We assess the treatment of patients with bisphosphonate‐related osteonecrosis of the jaws (BRONJ).


Physics in Medicine and Biology | 2003

Computer-enhanced stereoscopic vision in a head-mounted operating binocular

Wolfgang Birkfellner; Michael Figl; Christian Matula; Johann Hummel; Rudolf Hanel; Herwig Imhof; Felix Wanschitz; Arne Wagner; Franz Watzinger; Helmar Bergmann

Based on the Varioscope, a commercially available head-mounted operating binocular, we have developed the Varioscope AR, a see through head-mounted display (HMD) for augmented reality visualization that seamlessly fits into the infrastructure of a surgical navigation system. We have assessed the extent to which stereoscopic visualization improves target localization in computer-aided surgery in a phantom study. In order to quantify the depth perception of a user aiming at a given target, we have designed a phantom simulating typical clinical situations in skull base surgery. Sixteen steel spheres were fixed at the base of a bony skull, and several typical craniotomies were applied. After having taken CT scans, the skull was filled with opaque jelly in order to simulate brain tissue. The positions of the spheres were registered using VISIT, a system for computer-aided surgical navigation. Then attempts were made to locate the steel spheres with a bayonet probe through the craniotomies using VISIT and the Varioscope AR as a stereoscopic display device. Localization of targets 4 mm in diameter using stereoscopic vision and additional visual cues indicating target proximity had a success rate (defined as a first-trial hit rate) of 87.5%. Using monoscopic vision and target proximity indication, the success rate was found to be 66.6%. Omission of visual hints on reaching a target yielded a success rate of 79.2% in the stereo case and 56.25% with monoscopic vision. Time requirements for localizing all 16 targets ranged from 7.5 min (stereo, with proximity cues) to 10 min (mono, without proximity cues). Navigation error is primarily governed by the accuracy of registration in the navigation system, whereas the HMD does not appear to influence localization significantly. We conclude that stereo vision is a valuable tool in augmented reality guided interventions.


Plastic and Reconstructive Surgery | 2001

Placement of endosteal implants in the zygoma after maxillectomy: a Cadaver study using surgical navigation.

Franz Watzinger; Wolfgang Birkfellner; Felix Wanschitz; Farzad Ziya; Arne Wagner; Judith Kremser; Franz Kainberger; Klaus Huber; Helmar Bergmann; Rolf Ewers

Endosteal implants facilitate obturator prosthesis fixation in tumor patients after maxillectomy. Previous clinical studies have shown, however, that the survival of implants placed into available bone after maxillectomy is generally poor. Nevertheless, implants positioned optimally in residual zygomatic bone provide superior stability from a biomechanical point of view. In a pilot study, the authors assessed the precision of VISIT, a computer‐aided surgical navigation system dedicated to the placement of endosteal implants in the maxillofacial area. Five cadaver specimens underwent hemimaxillectomy. The cadaver head was matched to a preoperative high‐resolution computed tomograph by using implanted surgical microscrews as fiducial markers. The position of a surgical drill relative to the cadaver head was determined with an optical tracking system. Implants were placed into the zygomatic arch, where maximum bone volume was available. The results were assessed using tests for localization accuracy and postoperative computed tomographic scans of the cadaver specimens. The localization accuracy of landmarks on the bony skull was 0.6 ± 0.3 mm (average ± SD), as determined with a 5‐df pointer probe; the localization accuracy of the tip of the implant burr was 1.7 ± 0.4 mm. The accuracy of the implant position compared with the planned position was 1.3 ± 0.8 mm for the external perforation of the zygoma and 1.7 ±1.3 mm for the internal perforation. Eight of 10 implants were inserted with maximal contact to surrounding bone, and two implants were located unfavorably. Reliable placement of implants in this region is difficult to achieve. The technique described in this article may be very helpful in the management of patients after maxillary resection with poor support for obturator prostheses. (Plast. Reconstr. Surg. 107: 659, 2001.)


Journal of Cranio-maxillofacial Surgery | 1997

Extensive facial vascular malformations and haemangiomas: a review of the literature and case reports.

Franz Watzinger; S. Gössweiner; A. Wagner; B. Richling; G. Millesi-Schobel; Karl Hollmann

We present 6 selected cases of extensive facial vascular anomalies extending to the skull base or actually involving it. These patients are compared with other cases in the literature. The spontaneous course of these vascular lesions is different and so variable treatment modalities are suggested depending on the age of the patient and the type of lesion. In young children, haemangiomas are common and spontaneous involution is characteristic. Conservative treatment in the sense of a wait-and-see approach is thereby favoured if there is no urgent indication such as involvement of essential structures, e.g. blockage of an orifice as demonstrated in one case or complications such as excessive bleeding. Vascular malformations most commonly appear in adults, there is no tendency to spontaneous involution and resection is usually necessary, especially in arteriovenous malformations. Nowadays, preoperative superselective embolization is recommended to minimize intraoperative blood loss. Superselective embolization is the treatment of choice in cases of a-v fistulae. Proximal ligation of the supplying arteries should be avoided because this may make embolization more difficult, and may be responsible for the common occurrence of rapid revascularization.

Collaboration


Dive into the Franz Watzinger's collaboration.

Top Co-Authors

Avatar

Rolf Ewers

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dritan Turhani

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Wolfgang Birkfellner

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar

Michael Figl

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar

Arne Wagner

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Johann Hummel

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge