Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where G. Bruno is active.

Publication


Featured researches published by G. Bruno.


Physical Review Letters | 2011

Dark Matter Results from 225 Live Days of XENON100 Data

E. Aprile; K. Arisaka; F. Arneodo; A. Askin; L. Baudis; A. Behrens; K. Bokeloh; E. Brown; T. Bruch; G. Bruno; João Cardoso; W. T. Chen; B. Choi; D. Cline; E. Duchovni; S. Fattori; A. D. Ferella; F. Gao; Karl-Ludwig Giboni; E. Gross; A. Kish; C. W. Lam; J. Lamblin; R. F. Lang; C. Levy; K. E. Lim; Q. Lin; S. Lindemann; Manfred Lindner; J. A. M. Lopes

We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso for 13 months during 2011 and 2012. XENON100 features an ultralow electromagnetic background of (5.3 ± 0.6) × 10(-3) events/(keV(ee) × kg × day) in the energy region of interest. A blind analysis of 224.6 live days × 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the predefined nuclear recoil energy range of 6.6-30.5 keV(nr) are consistent with the background expectation of (1.0 ± 0.2) events. A profile likelihood analysis using a 6.6-43.3 keV(nr) energy range sets the most stringent limit on the spin-independent elastic weakly interacting massive particle-nucleon scattering cross section for weakly interacting massive particle masses above 8 GeV/c(2), with a minimum of 2 × 10(-45) cm(2) at 55 GeV/c(2) and 90% confidence level.


Physical Review Letters | 2017

First Dark Matter Search Results from the XENON1T Experiment

E. Aprile; J. Aalbers; F. Agostini; M. Alfonsi; F. D. Amaro; M. Anthony; F. Arneodo; P. Barrow; L. Baudis; B. Bauermeister; M.L. Benabderrahmane; T. Berger; P. A. Breur; A. Brown; S. Bruenner; G. Bruno; R. Budnik; Lukas Bütikofer; J. Calvén; João Cardoso; M. Cervantes; D. Cichon; D. Coderre; A.P. Colijn; J. Conrad; J.P. Cussonneau; M.P. Decowski; P. de Perio; P. Di Gangi; A. Di Giovanni

We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the (1042±12)-kg fiducial mass and in the [5,40]u2009u2009keV_{nr} energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (1.93±0.25)×10^{-4}u2009u2009events/(kg×day×keV_{ee}), the lowest ever achieved in such a dark matter detector. A profile likelihood analysis shows that the data are consistent with the background-only hypothesis. We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10u2009u2009GeV/c^{2}, with a minimum of 7.7×10^{-47}u2009u2009cm^{2} for 35-GeV/c^{2} WIMPs at 90%xa0C.L.


Physical Review Letters | 2013

Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data

E. Aprile; M. Alfonsi; K. Arisaka; F. Arneodo; C. Balan; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; K. Bokeloh; Abbe Brown; E. Brown; G. Bruno; R. Budnik; João Cardoso; W. T. Chen; B. Choi; A.P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; F. Gao; M. Garbini; C. Ghag; Karl-Ludwig Giboni; L. W. Goetzke

We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days×34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129Xe and 131Xe nuclei. This leads to the most stringent upper limits on WIMP-neutron cross sections for WIMP masses above 6 GeV/c², with a minimum cross section of 3.5×10(-40) cm² at a WIMP mass of 45 GeV/c², at 90% confidence level.


Physical Review D | 2011

Implications on inelastic dark matter from 100 live days of XENON100 data

E. Aprile; K. Arisaka; F. Arneodo; A. Askin; L. Baudis; A. Behrens; K. Bokeloh; E. Brown; T. Bruch; G. Bruno; João Cardoso; W. T. Chen; B. Choi; D. Cline; E. Duchovni; S. Fattori; A. D. Ferella; F. Gao; Karl-Ludwig Giboni; E. Gross; A. Kish; C. W. Lam; J. Lamblin; R. F. Lang; C. Levy; K. E. Lim; Q. Lin; S. Lindemann; Manfred Lindner; J. A. M. Lopes

The XENON100 experiment has recently completed a dark matter run with 100.9 live-days of data, taken from January to June 2010. Events in a 48kg fiducial volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A total of three events have been found in the predefined signal region, compatible with the background prediction of (1.8 pm 0.6) events. Based on this analysis we present limits on the WIMP-nucleon cross section for inelastic dark matter. With the present data we are able to rule out the explanation for the observed DAMA/LIBRA modulation as being due to inelastic dark matter scattering off iodine at a 90% confidence level.


Physical Review D | 2014

First Axion Results from the XENON100 Experiment

E. Aprile; F. Agostini; M. Alfonsi; K. Arisaka; F. Arneodo; M. Auger; C. Balan; P. Barrow; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; K. Bokeloh; A. Brown; E. Brown; Stefan Brünner; G. Bruno; R. Budnik; João Cardoso; A.P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; F. Gao; M. Garbini; C. Geis

We present the first results of searches for axions and axionlike particles with the XENON100 experiment. The axion-electron coupling constant, g Ae , has been probed by exploiting the axioelectric effect in liquid xenon. A profile likelihood analysis of 224.6 live days × 34-kg exposure has shown no evidence for a signal. By rejecting g Ae larger than 7.7×10 −12 (90% C.L.) in the solar axion search, we set the best limit to date on this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions heavier than 0.3 and 80u2009u2009eV/c 2 , respectively. For axionlike particles, under the assumption that they constitute the whole abundance of dark matter in our galaxy, we constrain g Ae to be lower than 1×10 −12 (90% C.L.) for masses between 5 and 10u2009u2009keV/c 2 .


Astroparticle Physics | 2014

Analysis of the XENON100 Dark Matter Search Data

E. Aprile; M. Alfonsi; K. Arisaka; F. Arneodo; C. Balan; L. Baudis; A. Behrens; P. Beltrame; K. Bokeloh; E. Brown; G. Bruno; R. Budnik; João Cardoso; W. T. Chen; B. Choi; D. Cline; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; F. Gao; M. Garbini; Karl-Ludwig Giboni; L. W. Goetzke; C. Grignon; E. Gross; W. Hampel

The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have been used in the 100.9 and 224.6 live days science runs from which results on spin-independent elastic, spin-dependent elastic and inelastic WIMP-nucleon cross-sections have already been reported.


Journal of Physics G | 2014

Observation and applications of single-electron charge signals in the XENON100 experiment

E. Aprile; M. Alfonsi; K. Arisaka; F. Arneodo; C. Balan; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; K. Bokeloh; Abbe Brown; E. Brown; S. Bruenner; G. Bruno; R. Budnik; João Cardoso; W. T. Chen; B. Choi; A. P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; F. Gao; M. Garbini; C. Ghag; Karl-Ludwig Giboni

The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter weakly interacting massive particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.


Physical Review Letters | 2012

Measurement of the velocity of neutrinos from the CNGS beam with the large volume detector.

N. Agafonova; M. Aglietta; P. Antonioli; V. V. Ashikhmin; G. Bari; Bertoni R; E. Bressan; G. Bruno; Dadykin Vl; W. Fulgione; P. Galeotti; M. Garbini; P. L. Ghia; P. Giusti; E. Kemp; A. Malgin; B. Miguez; A. Molinario; R. Persiani; I. A. Pless; V. G. Ryasny; O. G. Ryazhskaya; O. Saavedra; G. Sartorelli; Shakyrianova Ir; M. Selvi; G. Trinchero; C. Vigorito; V. F. Yakushev; A. Zichichi

We report the measurement of the time of flight of ∼17 GeV ν(μ) on the CNGS baseline (732 km) with the Large Volume Detector (LVD) at the Gran Sasso Laboratory. The CERN-SPS accelerator has been operated from May 10th to May 24th 2012, with a tightly bunched-beam structure to allow the velocity of neutrinos to be accurately measured on an event-by-event basis. LVD has detected 48 neutrino events, associated with the beam, with a high absolute time accuracy. These events allow us to establish the following limit on the difference between the neutrino speed and the light velocity: -3.8 × 10(-6) < (v(ν)-c)/c < 3.1 × 10(-6) (at 99% C.L.). This value is an order of magnitude lower than previous direct measurements.


European Physical Journal C | 2015

Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

E. Aprile; F. Agostini; M. Alfonsi; L. Arazi; K. Arisaka; F. Arneodo; M. Auger; C. Balan; P. Barrow; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; Abbe Brown; E. Brown; S. Bruenner; G. Bruno; R. Budnik; Lukas Bütikofer; João Cardoso; Daniel Coderre; A. P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; A. Di Giovanni; E. Duchovni; S. Fattori; A. D. Ferella; A. Fieguth

The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.


Journal of Instrumentation | 2014

Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment

E. Aprile; F. Agostini; M. Alfonsi; K. Arisaka; F. Arneodo; M. Auger; C. Balan; P. Barrow; L. Baudis; B. Bauermeister; A. Behrens; P. Beltrame; K. Bokeloh; A. Breskin; Abbe Brown; E. Brown; S. Bruenner; G. Bruno; R. Budnik; João Cardoso; A. P. Colijn; H. Contreras; J. P. Cussonneau; M.P. Decowski; E. Duchovni; S. Fattori; A. D. Ferella; W. Fulgione; M. Garbini; C. Geis

XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of 2 10-47 c 2 for WIMP masses around 50 GeV2, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of ~ 10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons (>99.5%) and showers of secondary particles from muon interactions in the rock (>70%). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.

Collaboration


Dive into the G. Bruno's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

F. Arneodo

New York University Abu Dhabi

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

E. Brown

Rensselaer Polytechnic Institute

View shared research outputs
Top Co-Authors

Avatar

K. Arisaka

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

E. Duchovni

Weizmann Institute of Science

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge