Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where G. K. Robertson is active.

Publication


Featured researches published by G. K. Robertson.


Physics of Plasmas | 2013

Beryllium liner implosion experiments on the Z accelerator in preparation for magnetized liner inertial fusion

Ryan D McBride; M. R. Martin; R.W. Lemke; J. B. Greenly; Christopher A. Jennings; Dean C. Rovang; Daniel Brian Sinars; M. E. Cuneo; Mark Herrmann; Stephen A. Slutz; C. Nakhleh; D. D. Ryutov; Jean-Paul Davis; Dawn G. Flicker; B.E. Blue; Kurt Tomlinson; D. G. Schroen; R. M. Stamm; G. E. Smith; J. K. Moore; T. J. Rogers; G. K. Robertson; R. J. Kamm; I. C. Smith; M. E. Savage; W. A. Stygar; G. A. Rochau; M. Jones; M. R. Lopez; John L. Porter

Multiple experimental campaigns have been executed to study the implosions of initially solid beryllium (Be) liners (tubes) on the Z pulsed-power accelerator. The implosions were driven by current pulses that rose from 0 to 20 MA in either 100 or 200 ns (200 ns for pulse shaping experiments). These studies were conducted in support of the recently proposed Magnetized Liner Inertial Fusion concept [Slutz et al., Phys. Plasmas 17, 056303 (2010)], as well as for exploring novel equation-of-state measurement techniques. The experiments used thick-walled liners that had an aspect ratio (initial outer radius divided by initial wall thickness) of either 3.2, 4, or 6. From these studies, we present three new primary results. First, we present radiographic images of imploding Be liners, where each liner contained a thin aluminum sleeve for enhancing the contrast and visibility of the liners inner surface in the images. These images allow us to assess the stability of the liners inner surface more accurately and more directly than was previously possible. Second, we present radiographic images taken early in the implosion (prior to any motion of the liners inner surface) of a shockwave propagating radially inward through the liner wall. Radial mass density profiles from these shock compression experiments are contrasted with profiles from experiments where the Z accelerators pulse shaping capabilities were used to achieve shockless (“quasi-isentropic”) liner compression. Third, we present “micro-B” measurements of azimuthal magnetic field penetration into the initially vacuum-filled interior of a shocked liner. Our measurements and simulations reveal that the penetration commences shortly after the shockwave breaks out from the liners inner surface. The field then accelerates this low-density “precursor” plasma to the axis of symmetry.


Physics of Plasmas | 2014

Modified helix-like instability structure on imploding z-pinch liners that are pre-imposed with a uniform axial magnetic field.

Thomas James Awe; Christopher A. Jennings; R. D. McBride; M. E. Cuneo; Derek C. Lamppa; M. R. Martin; Dean C. Rovang; Daniel Brian Sinars; Stephen A. Slutz; A. C. Owen; Kurt Tomlinson; M. R. Gomez; Stephanie B. Hansen; Mark Herrmann; M. Jones; J. L. McKenney; G. K. Robertson; G. A. Rochau; M. E. Savage; D. G. Schroen; W. A. Stygar

Recent experiments at the Sandia National Laboratories Z Facility have, for the first time, studied the implosion dynamics of magnetized liner inertial fusion (MagLIF) style liners that were pre-imposed with a uniform axial magnetic field. As reported [T. J. Awe et al., Phys. Rev. Lett. 111, 235005 (2013)] when premagnetized with a 7 or 10 T axial field, these liners developed 3D-helix-like hydrodynamic instabilities; such instabilities starkly contrast with the azimuthally correlated magneto-Rayleigh-Taylor (MRT) instabilities that have been consistently observed in many earlier non-premagnetized experiments. The helical structure persisted throughout the implosion, even though the azimuthal drive field greatly exceeded the expected axial field at the liners outer wall for all but the earliest stages of the experiment. Whether this modified instability structure has practical importance for magneto-inertial fusion concepts depends primarily on whether the modified instability structure is more stable th...


Review of Scientific Instruments | 2014

Pulsed-coil magnet systems for applying uniform 10–30 T fields to centimeter-scale targets on Sandia's Z facility

Dean C. Rovang; Derek C. Lamppa; M. E. Cuneo; Albert C. Owen; J. L. McKenney; Drew Johnson; S. Radovich; R. J. Kaye; R. D. McBride; C. S. Alexander; Thomas James Awe; Stephen A. Slutz; Adam B Sefkow; Thomas A. Haill; P. A. Jones; J. W. Argo; D. G. Dalton; G. K. Robertson; E.M. Waisman; Daniel Brian Sinars; J. Meissner; M. Milhous; D. N. Nguyen; C. H. Mielke

Sandia has successfully integrated the capability to apply uniform, high magnetic fields (10-30 T) to high energy density experiments on the Z facility. This system uses an 8-mF, 15-kV capacitor bank to drive large-bore (5 cm diameter), high-inductance (1-3 mH) multi-turn, multi-layer electromagnets that slowly magnetize the conductive targets used on Z over several milliseconds (time to peak field of 2-7 ms). This system was commissioned in February 2013 and has been used successfully to magnetize more than 30 experiments up to 10 T that have produced exciting and surprising physics results. These experiments used split-magnet topologies to maintain diagnostic lines of sight to the target. We describe the design, integration, and operation of the pulsed coil system into the challenging and harsh environment of the Z Machine. We also describe our plans and designs for achieving fields up to 20 T with a reduced-gap split-magnet configuration, and up to 30 T with a solid magnet configuration in pursuit of the Magnetized Liner Inertial Fusion concept.


Physics of Plasmas | 2015

Diagnosing magnetized liner inertial fusion experiments on Za)

Stephanie B. Hansen; M. R. Gomez; Adam B Sefkow; Stephen A. Slutz; Daniel Brian Sinars; Kelly Hahn; Eric Harding; P. F. Knapp; Paul Schmit; Thomas James Awe; R. D. McBride; Christopher A. Jennings; Matthias Geissel; A. J. Harvey-Thompson; Kyle Peterson; Dean C. Rovang; Gordon Andrew Chandler; G. W. Cooper; Michael Edward Cuneo; Mark Herrmann; Mark Hess; Owen Johns; Derek C. Lamppa; M. R. Martin; John L. Porter; G. K. Robertson; G. A. Rochau; C. L. Ruiz; M. E. Savage; I. C. Smith

Magnetized Liner Inertial Fusion experiments performed at Sandias Z facility have demonstrated significant thermonuclear fusion neutron yields (∼1012 DD neutrons) from multi-keV deuterium plasmas inertially confined by slow (∼10 cm/μs), stable, cylindrical implosions. Effective magnetic confinement of charged fusion reactants and products is signaled by high secondary DT neutron yields above 1010. Analysis of extensive power, imaging, and spectroscopic x-ray measurements provides a detailed picture of ∼3 keV temperatures, 0.3 g/cm3 densities, gradients, and mix in the fuel and liner over the 1–2 ns stagnation duration.


Proceedings of SPIE | 2015

An overview of the Ultrafast X-ray Imager (UXI) program at Sandia Labs

Liam D. Claus; Lu Fang; Randolph R. Kay; Mark Kimmel; J. Long; G. K. Robertson; M. Sanchez; John W. Stahoviak; Douglas C. Trotter; John L. Porter

The Ultra-Fast X-ray Imager (UXI) program is an ongoing effort at Sandia National Laboratories to create high speed, multi-frame, time gated Read Out Integrated Circuits (ROICs), and a corresponding suite of photodetectors to image a wide variety of High Energy Density (HED) physics experiments on both Sandia’s Z-Machine and the National Ignition Facility (NIF). The program is currently fielding a 1024 x 448 prototype camera with 25 μm pixel spatial resolution, 2 frames of in-pixel storage and the possibility of exchanging spatial resolution to achieve 4 or 8 frames of storage. The camera’s minimum integration time is 2 ns. Minimum signal target is 1500 e- rms and full well is 1.5 million e-. The design and initial characterization results will be presented as well as a description of future imagers.


Proceedings of SPIE | 2016

Initial characterization results of a 1024x448, 25-μm multi-frame camera with 2ns integration time for the Ultrafast X-ray Imager (UXI) program at Sandia National Laboratories

Liam D. Claus; G. K. Robertson; Lu Fang; Randolph R. Kay; Mark Kimmel; M. Sanchez; John W. Stahoviak; Douglas C. Trotter; John L. Porter

The Hippogriff camera developed at Sandia National Laboratories as part of the Ultra-Fast X-ray Imager (UXI) program is a high-speed, multi-frame, time-gated imager for use on a wide variety of High Energy Density (HED) physics experiments on both Sandia’s Z-Machine and the National Ignition Facility. The camera is a 1024 x 448 pixel array with 25 μm spatial resolution, containing 2 frames per pixel natively and has achieved 2 ns minimum integration time. It is sensitive to both optical photons as well as soft X-rays up to ~6 keV. The Hippogriff camera is the second generation UXI camera that contains circuitry to trade spatial resolution for additional frames of temporal coverage. The user can reduce the row-wise spatial resolution from the native 25 μm to increase the number of frames in a data set to 4 frames at 50 μm or 8 frames at 100 μm spatial resolution. This feature, along with both optical and X-ray sensitivity, facilitates additional experimental flexibility. Minimum signal is 1500 erms and full well is 1.5 million e-.


Review of Scientific Instruments | 2018

The dilation aided single–line–of–sight x–ray camera for the National Ignition Facility: Characterization and fielding

S. R. Nagel; Arthur C. Carpenter; J. Park; Matthew S. Dayton; P. M. Bell; D. K. Bradley; B. T. Funsten; B. W. Hatch; S. Heerey; J. M. Hill; J. P. Holder; E. R. Hurd; C. C. Macaraeg; Pratik Patel; R. B. Petre; K. Piston; C. A. Trosseille; K. Engelhorn; T. J. Hilsabeck; T. M. Chung; A. K. L. Dymoke-Bradshaw; J. D. Hares; Liam D. Claus; T. D. England; B. B. Mitchell; John L. Porter; G. K. Robertson; Marcos O. Sanchez

Crystal x-ray imaging is frequently used in inertial confinement fusion and laser-plasma interaction applications as it has advantages compared to pinhole imaging, such as higher signal throughput, better achievable spatial resolution, and chromatic selection. However, currently used x-ray detectors are only able to obtain a single time resolved image per crystal. The dilation aided single-line-of-sight x-ray camera described here was designed for the National Ignition Facility (NIF) and combines two recent diagnostic developments, the pulse dilation principle used in the dilation x-ray imager and a ns-scale multi-frame camera that uses a hold and readout circuit for each pixel. This enables multiple images to be taken from a single-line-of-sight with high spatial and temporal resolution. At the moment, the instrument can record two single-line-of-sight images with spatial and temporal resolution of 35 μm and down to 35 ps, respectively, with a planned upgrade doubling the number of images to four. Here we present the dilation aided single-line-of-sight camera for the NIF, including the x-ray characterization measurements obtained at the COMET laser, as well as the results from the initial timing shot on the NIF.


Proceedings of SPIE | 2016

A characterization technique for nanosecond gated CMOS x-ray cameras

Matthew S. Dayton; Arthur C. Carpenter; H. Chen; N. E. Palmer; P. S. Datte; P. M. Bell; M. Sanchez; Liam D. Claus; G. K. Robertson; John L. Porter

We present a characterization technique for nanosecond gated CMOS cameras designed and built by Sandia National Laboratory under their Ultra-Fast X-ray Imager program. The cameras have been used to record images during HED physics experiments at Sandia’s Z Facility and at LLNL’s National Ignition Facility. The behavior of the camera’s fast shutters was not expected to be ideal since they propagate over a large pixel array of 25 mm x 12 mm, which could result in shutter timing skew, variations in the FWHM, and variations in the shutter’s peak response. Consequently, a detailed characterization of the camera at the pixel level was critical for interpreting the images. Assuming the pixel’s photo-response was linear, the shutter profiles for each pixel were simplified to a pair of sigmoid functions using standard non-linear fitting methods to make the subsequent analysis less computationally intensive. A pixel-level characterization of a ”Furi” camera showed frame-to-frame gain variations that could be normalized with a gain mask and significant timing skew at the sensor’s center column that could not be corrected. The shutter profiles for Furi were then convolved with data generated from computational models to forward fit images collected with the camera.


Proceedings of SPIE | 2016

Single Line of Sight CMOS radiation tolerant camera system design overview

Arthur C. Carpenter; Matthew S. Dayton; J. R. Kimbrough; P. S. Datte; C. Macaraeg; B. Funsten; P. Gardner; D. Kittle; K. Charron; P. M. Bell; J. Celeste; M. Sanchez; B. Mitchell; Liam D. Claus; G. K. Robertson; John L. Porter; G. Sims; T. J. Hilsabeck

This paper covers the preliminary design of a radiation tolerant nanosecond-gated multi-frame CMOS camera system for use in the NIF. Electrical component performance data from 14 MeV neutron and cobalt 60 radiation testing will be discussed. The recent development of nanosecond-gated multi-frame hybrid-CMOS (hCMOS) focal plane arrays by the Ultrafast X-ray Imaging (UXI) group at Sandia National Lab has generated a need for custom camera electronics to operate in the pulsed radiation environment of the NIF target chamber. Design requirements and performance data for the prototype camera system will be discussed. The design and testing approach for the radiation tolerant camera system will be covered along with the evaluation of commercial off the shelf (COTS) electronic component such as FPGAs, voltage regulators, ADCs, DACs, optical transceivers, and other electronic components. Performance changes from radiation exposure on select components will be discussed. Integration considerations for x-ray imaging diagnostics on the NIF will also be covered.


Review of Scientific Instruments | 2018

The single-line-of-sight, time-resolved x-ray imager diagnostic on OMEGA

W. Theobald; C. Sorce; M. Bedzyk; S. T. Ivancic; F. J. Marshall; C. Stoeckl; R. C. Shah; M. Lawrie; S. P. Regan; T. C. Sangster; E. M. Campbell; T. J. Hilsabeck; K. Englehorn; J. D. Kilkenny; D. Morris; T. M. Chung; J. D. Hares; A. K. L. Dymoke-Bradshaw; P. M. Bell; J. Celeste; A. C. Carpenter; Matthew S. Dayton; D. K. Bradley; M. C. Jackson; L. A. Pickworth; S. R. Nagel; G. A. Rochau; John L. Porter; M. Sanchez; Liam D. Claus

The single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI) on OMEGA is one of a new generation of fast-gated x-ray cameras comprising an electron pulse-dilation imager and a nanosecond-gated, burst-mode, hybrid complementary metal-oxide semiconductor sensor. SLOS-TRXI images the core of imploded cryogenic deuterium-tritium shells in inertial confinement fusion experiments in the ∼4- to 9-keV photon energy range with a pinhole imager onto a photocathode. The diagnostic is mounted on a fixed port almost perpendicular to a 16-channel, framing-camera-based, time-resolved Kirkpatrick-Baez microscope, providing a second time-gated line of sight for hot-spot imaging on OMEGA. SLOS-TRXI achieves ∼40-ps temporal resolution and better than 10-μm spatial resolution. Shots with neutron yields of up to 1 × 1014 were taken without observed neutron-induced background signal. The implosion images from SLOS-TRXI show the evolution of the stagnating core.

Collaboration


Dive into the G. K. Robertson's collaboration.

Top Co-Authors

Avatar

Daniel Brian Sinars

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar

John L. Porter

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar

Dean C. Rovang

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar

Derek C. Lamppa

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar

Stephen A. Slutz

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar

Thomas James Awe

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. R. Martin

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar

R. D. McBride

Sandia National Laboratories

View shared research outputs
Top Co-Authors

Avatar

Liam D. Claus

Sandia National Laboratories

View shared research outputs
Researchain Logo
Decentralizing Knowledge