Medical Physics | 2012

Dosimetric characterization of a synthetic single crystal diamond detector in clinical radiation therapy small photon beams

I. Ciancaglioni; M. Marinelli; E. Milani; G. Prestopino; C. Verona; G. Verona-Rinati; R. Consorti; A. Petrucci; F. De Notaristefani

PURPOSE To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams. METHODS The dosimetric properties of a diamond-based detector were assessed by comparison with a reference microionization chamber. The diamond device was operated at zero bias voltage under irradiation with high-energy radiotherapic photon beams. The stability of the detector response and its dose and dose rate dependence were measured. Different square field sizes ranging from 1 × 1 cm2 to 10 × 10 cm2 were used during comparative dose distribution measurements by means of percentage depth dose curves (PDDs), lateral beam profiles, and output factors. The angular and temperature dependence of the diamond detector response were also studied. RESULTS The detector response shows a deviation from linearity of less than ±0.5% in the 0.01-7 Gy range and dose rate dependence below ±0.5% in the 1-6 Gy/min range. PDDs and output factors are in good agreement with those measured by the reference ionization chamber within 1%. No angular dependence is observed by rotating the detector along its axis, while ∼3.5% maximum difference is measured by varying the radiation incidence angle in the polar direction. The temperature dependence was investigated as well and a ±0.2% variation of the detector response is found in the 18-40 °C range. CONCLUSIONS The obtained results indicate the investigated synthetic diamond-based detector as a candidate for small field clinical radiation dosimetry in advanced radiation therapy techniques.PURPOSE To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams. METHODS The dosimetric properties of a diamond-based detector were assessed by comparison with a reference microionization chamber. The diamond device was operated at zero bias voltage under irradiation with high-energy radiotherapic photon beams. The stability of the detector response and its dose and dose rate dependence were measured. Different square field sizes ranging from 1 × 1 cm(2) to 10 × 10 cm(2) were used during comparative dose distribution measurements by means of percentage depth dose curves (PDDs), lateral beam profiles, and output factors. The angular and temperature dependence of the diamond detector response were also studied. RESULTS The detector response shows a deviation from linearity of less than ±0.5% in the 0.01-7 Gy range and dose rate dependence below ±0.5% in the 1-6 Gy∕min range. PDDs and output factors are in good agreement with those measured by the reference ionization chamber within 1%. No angular dependence is observed by rotating the detector along its axis, while ∼3.5% maximum difference is measured by varying the radiation incidence angle in the polar direction. The temperature dependence was investigated as well and a ±0.2% variation of the detector response is found in the 18-40 °C range. CONCLUSIONS The obtained results indicate the investigated synthetic diamond-based detector as a candidate for small field clinical radiation dosimetry in advanced radiation therapy techniques.


Journal of Applied Physics | 2010

Chemical vapor deposition diamond based multilayered radiation detector: Physical analysis of detection properties

S. Almaviva; M. Marinelli; E. Milani; G. Prestopino; A. Tucciarone; C. Verona; G. Verona-Rinati; M. Angelone; M. Pillon; I. Dolbnya; K. Sawhney; N. Tartoni

Recently, solid state photovoltaic Schottky diodes, able to detect ionizing radiation, in particular, x-ray and ultraviolet radiation, have been developed at the University of Rome “Tor Vergata.” We report on a physical and electrical properties analysis of the device and a detailed study of its detection capabilities as determined by its electrical properties. The design of the device is based on a metal/nominally intrinsic/p-type diamond layered structure obtained by microwave plasma chemical vapor deposition of homoepitaxial single crystal diamond followed by thermal evaporation of a metallic contact. The device can operate in an unbiased mode by using the built-in potential arising from the electrode-diamond junction. We compare the expected response of the device to photons of various energies calculated through Monte Carlo simulation with experimental data collected in a well controlled experimental setup i.e., monochromatic high flux x-ray beams from 6 to 20 keV, available at the Diamond Light Sour...


Applied Physics Letters | 2006

High performance Li6F-diamond thermal neutron detectors

M. Marinelli; E. Milani; G. Prestopino; M. Scoccia; A. Tucciarone; G. Verona-Rinati; M. Angelone; M. Pillon; D. Lattanzi

Fabrication reproducibility and high performance reliability were obtained in fissile-material-free thermal neutron detectors based on chemical vapor deposited diamond in a multilayered p-type/intrinsic/metal design. Under α particle irradiation, all the detectors (more than ten) have shown 100% charge collection efficiency and approximately 1.5% energy resolution. A Li6F layer was deposited on the detector surface as converting material for thermal neutrons through the Li6(n,α)T nuclear reaction. Both the 2.73MeV tritium and the 2.06MeV α peaks are detected and clearly resolved. Stable performance and excellent linear behavior of the count rate versus the incident neutron flux were observed.


Journal of Applied Physics | 2008

Thermal and fast neutron detection in chemical vapor deposition single-crystal diamond detectors

S. Almaviva; M. Marinelli; E. Milani; G. Prestopino; A. Tucciarone; C. Verona; G. Verona-Rinati; M. Angelone; D. Lattanzi; M. Pillon; Rosa Maria Montereali; M.A. Vincenti

Recently, a compact solid-state neutron detector capable of simultaneously detecting thermal and fast neutrons was proposed [M. Marinelli et al., Appl. Phys. Lett. 89, 143509 (2006)]. Its design is based on a p-type/intrinsic/metal layered structure obtained by Microwave Plasma Chemical Vapor Deposition (CVD) of homoepitaxial diamond followed by thermal evaporation of an Al contact and a L6iF converting layer. Fast neutrons are directly detected in the CVD diamond bulk, since they have enough energy to produce the C12(n,α)B9e reaction in diamond. Thermal neutrons are instead converted into charged particles in the L6iF layer through the L6i(n,α)T nuclear reaction. These charged particles are then detected in the diamond layer. The thickness of the L6iF converting layer and the CVD diamond sensing layer affect the counting efficiency and energy resolution of the detector both for low- (thermal) and high-energy neutrons. An analysis is carried out on the dynamics of the L6i(n,α)T and the C12(n,α)B9e reactio...


Medical Physics | 2013

Characterization of a synthetic single crystal diamond Schottky diode for radiotherapy electron beam dosimetry

C. Di Venanzio; M. Marinelli; E. Milani; G. Prestopino; C. Verona; G. Verona-Rinati; M.D. Falco; Paolo Bagalà; R. Santoni; M. Pimpinella

PURPOSE To investigate the dosimetric properties of synthetic single crystal diamond based Schottky diodes under irradiation with therapeutic electron beams from linear accelerators. METHODS A single crystal diamond detector was fabricated and tested under 6, 8, 10, 12, and 15 MeV electron beams. The detector performances were evaluated using three types of commercial detectors as reference dosimeters: an Advanced Markus plane parallel ionization chamber, a Semiflex cylindrical ionization chamber, and a p-type silicon detector. Preirradiation, linearity with dose, dose rate dependence, output factors, lateral field profiles, and percentage depth dose profiles were investigated and discussed. RESULTS During preirradiation the diamond detector signal shows a weak decrease within 0.7% with respect to the plateau value and a final signal stability of 0.1% (1σ) is observed after about 5 Gy. A good linear behavior of the detector response as a function of the delivered dose is observed with deviations below ±0.3% in the dose range from 0.02 to 10 Gy. In addition, the detector response is dose rate independent, with deviations below 0.3% in the investigated dose rate range from 0.17 to 5.45 Gy∕min. Percentage depth dose curves obtained from the diamond detector are in good agreement with the ones from the reference dosimeters. Lateral beam profile measurements show an overall good agreement among detectors, taking into account their respective geometrical features. The spatial resolution of solid state detectors is confirmed to be better than that of ionization chambers, being the one from the diamond detector comparable to that of the silicon diode. A good agreement within experimental uncertainties was also found in terms of output factor measurements between the diamond detector and reference dosimeters. CONCLUSIONS The observed dosimetric properties indicate that the tested diamond detector is a suitable candidate for clinical electron beam dosimetry.


Medical Physics | 2013

Evaluation of the dosimetric properties of a synthetic single crystal diamond detector in high energy clinical proton beams

A Mandapaka; A Ghebremedhin; B Patyal; M. Marinelli; G. Prestopino; C. Verona; G. Verona-Rinati

PURPOSE To investigate the dosimetric properties of a synthetic single crystal diamond Schottky diode for accurate relative dose measurements in large and small field high-energy clinical proton beams. METHODS The dosimetric properties of a synthetic single crystal diamond detector were assessed by comparison with a reference Markus parallel plate ionization chamber, an Exradin A16 microionization chamber, and Exradin T1a ion chamber. The diamond detector was operated at zero bias voltage at all times. Comparative dose distribution measurements were performed by means of Fractional depth dose curves and lateral beam profiles in clinical proton beams of energies 155 and 250 MeV for a 14 cm square cerrobend aperture and 126 MeV for 3, 2, and 1 cm diameter circular brass collimators. ICRU Report No. 78 recommended beam parameters were used to compare fractional depth dose curves and beam profiles obtained using the diamond detector and the reference ionization chamber. Warm-up∕stability of the detector response and linearity with dose were evaluated in a 250 MeV proton beam and dose rate dependence was evaluated in a 126 MeV proton beam. Stem effect and the azimuthal angle dependence of the diode response were also evaluated. RESULTS A maximum deviation in diamond detector signal from the average reading of less than 0.5% was found during the warm-up irradiation procedure. The detector response showed a good linear behavior as a function of dose with observed deviations below 0.5% over a dose range from 50 to 500 cGy. The detector response was dose rate independent, with deviations below 0.5% in the investigated dose rates ranging from 85 to 300 cGy∕min. Stem effect and azimuthal angle dependence of the diode signal were within 0.5%. Fractional depth dose curves and lateral beam profiles obtained with the diamond detector were in good agreement with those measured using reference dosimeters. CONCLUSIONS The observed dosimetric properties of the synthetic single crystal diamond detector indicate that its behavior is proton energy independent and dose rate independent in the investigated energy and dose rate range and it is suitable for accurate relative dosimetric measurements in large as well as in small field high energy clinical proton beams.


Journal of Applied Physics | 2008

Radiation tolerance of a high quality synthetic single crystal chemical vapor deposition diamond detector irradiated by 14.8 MeV neutrons

M. Pillon; M. Angelone; G. Aielli; S. Almaviva; M. Marinelli; E. Milani; G. Prestopino; A. Tucciarone; C. Verona; G. Verona-Rinati

Diamond exhibits many properties such as an outstanding radiation hardness and fast response time both important to design detectors working in extremely radioactive environments. Among the many applications these devices can be used for, there is the development of a fast and radiation hard neutron detector for the next generation of fusion reactors, such as the International Thermonuclear Experimental Reactor project, under construction at Cadarache in France. A technology to routinely produce electronic grade synthetic single crystal diamond detectors was recently developed by our group. One of such detectors, with an energy resolution of 0.9% as measured using an A241m α particle source, has been heavily irradiated with 14.8 MeV neutrons produced by the Frascati Neutron Generator. The modifications of its spectroscopic properties have been studied as a function of the neutron fluence up to 2.0×1014 n/cm2. In the early stage of the irradiation procedure an improvement in the spectroscopic performance o...


Applied Physics Letters | 2007

Synthetic single crystal diamond as a fission reactor neutron flux monitor

M. Marinelli; E. Milani; G. Prestopino; A. Tucciarone; C. Verona; G. Verona-Rinati; M. Angelone; D. Lattanzi; M. Pillon; R. Rosa; E. Santoro

Thermal neutron flux monitors were fabricated using chemical vapor deposited single crystal diamond in a p-type/intrinsic/metal/Li6F layered structure. They were placed 80cm above the core midplane of a 1MW research fission reactor, where the maximum neutron flux is 2.2×109neutrons∕cm2s. Good stability and reproducibility of the device response were observed over the whole reactor power range. A 150000counts∕s count rate was measured at the maximum reactor power with no degradation of the detector signal. As the multiple pile-up process due to the slow readout electronics is accounted for, an excellent linearity of the diamond response is observed.


IEEE Transactions on Nuclear Science | 2009

Neutron Detectors Based Upon Artificial Single Crystal Diamond

M. Angelone; G. Aielli; S. Almaviva; R. Cardarelli; Daniele Lattanzi; M. Marinelli; Enrico Milani; G. Prestopino; M. Pillon; Rinaldo Santonico; Aldo Tucciarone; C. Verona; G. Verona-Rinati

This paper reports about state-of-the-art artificial Single Crystal Diamond (SCD) neutron detectors based on a multilayered structure and grown by chemical vapour deposition (CVD) technique. Multilayered SCD detectors covered with a thin layer of 6LiF allow the simultaneous detection of both slow and fast neutrons and can operate in pulse and current mode. These detectors can also be produced with a thin layer of Boron. Application of SCD detectors to neutron detection around fusion tokamak is reported. Some problems related to the processing of the very fast electrical pulse produced by diamond are addressed and the achieved and foreseen development of the processing electronics is reported as well.


Medical Physics | 2015

Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams.

M. Marinelli; G. Prestopino; C. Verona; G. Verona-Rinati; M. Ciocca; A. Mirandola; A. Mairani; L. Raffaele; G. Magro

PURPOSE To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. METHODS The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30-250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm(2) were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm(2) area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using fluka Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. RESULTS A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam direction. A strong distortion in Bragg peak measurement was observed, confirming manufacturer recommendation on avoiding such configuration. Very good results were obtained for SOBP measurements, with a difference below 1% between measured and TPS-calculated doses. The stability of detector sensitivity in the observation period was within the experimental uncertainty. CONCLUSIONS Dosimetric characterization of a PTW microDiamond detector in high-energy scanned carbon ion beams was performed. The results of the present study showed that this detector is suitable for dosimetry of clinical carbon ion beams, with a negligible LET and dose-rate dependence.

Collaboration


Dive into the G. Prestopino's collaboration.

Top Co-Authors

Avatar

M. Marinelli

Instituto Politécnico Nacional

View shared research outputs
Top Co-Authors

Avatar

C. Verona

Instituto Politécnico Nacional

View shared research outputs
Top Co-Authors

Avatar

G. Verona-Rinati

Instituto Politécnico Nacional

View shared research outputs
Top Co-Authors

Avatar

E. Milani

Instituto Politécnico Nacional

View shared research outputs
Top Co-Authors

Avatar

S. Almaviva

Instituto Politécnico Nacional

View shared research outputs
Top Co-Authors

Avatar

A. Tucciarone

Instituto Politécnico Nacional

View shared research outputs
Top Co-Authors

Avatar

G. Verona-Rinati

Instituto Politécnico Nacional

View shared research outputs
Top Co-Authors

Avatar

M.D. Falco

University of Rome Tor Vergata

View shared research outputs
Top Co-Authors

Avatar

F. Pompili

Instituto Politécnico Nacional

View shared research outputs
Researchain Logo
Decentralizing Knowledge