Anesthesiology | 2005
Gene N. Peterson; Karen B. Domino; Robert A. Caplan; Karen L. Posner; Lorri A. Lee; Frederick W. Cheney
BACKGROUND The purpose of this study was to identify the patterns of liability associated with malpractice claims arising from management of the difficult airway. METHODS Using the American Society of Anesthesiologists Closed Claims database, the authors examined 179 claims for difficult airway management between 1985 and 1999 where a supplemental data collection tool was used and focused on airway management, outcomes, and the role of the 1993 Difficult Airway Guidelines in litigation. Chi-square tests and multiple logistic regression analysis compared risk factors for death or brain damage (death/BD) from two time periods: 1985-1992 and 1993-1999. RESULTS Difficult airway claims arose throughout the perioperative period: 67% upon induction, 15% during surgery, 12% at extubation, and 5% during recovery. Death/BD with induction of anesthesia decreased in 1993-1999 (35%) compared with 1985-1992 (62%; P < 0.05; odds ratio, 0.26; 95% confidence interval, 0.11-0.63; P = 0.003). In contrast, death/BD associated with other phases of anesthesia did not significantly change over the time periods. The odds of death/BD were increased by the development of an airway emergency (odds ratio, 14.98; 95% confidence interval, 6.37-35.27; P < 0.001). During airway emergencies, persistent intubation attempts were associated with death/BD (P < 0.05). Since 1993, the Airway Guidelines were used to defend care (8%) and criticize care (3%). CONCLUSIONS Death/BD in claims from difficult airway management associated with induction of anesthesia but not other phases of anesthesia decreased in 1993-1999 compared with 1985-1992. Development of additional management strategies for difficult airways encountered during maintenance, emergence, or recovery from anesthesia may improve patient safety.
Anesthesia & Analgesia | 2010
Bala G. Nair; Shu Fang Newman; Gene N. Peterson; Wei Ying Wu; Howard A. Schwid
BACKGROUND: Administration of prophylactic antibiotics during surgery is generally performed by the anesthesia providers. Timely antibiotic administration within the optimal time window before incision is critical for prevention of surgical site infections. However, this often becomes a difficult task for the anesthesia team during the busy part of a case when the patient is being anesthetized. METHODS: Starting with the implementation of an anesthesia information management system (AIMS), we designed and implemented several feedback mechanisms to improve compliance of proper antibiotic delivery and documentation. This included generating e-mail feedback of missed documentation, distributing monthly summary reports, and generating real-time electronic alerts with a decision support system. RESULTS: In 20,974 surgical cases for the period, June 2008 to January 2010, the interventions of AIMS install, e-mail feedback, summary reports, and real-time alerts changed antibiotic compliance by −1.5%, 2.3%, 4.9%, and 9.3%, respectively, when compared with the baseline value of 90.0% ± 2.9% when paper anesthesia records were used. Highest antibiotic compliance was achieved when using real-time alerts. With real-time alerts, monthly compliance was >99% for every month between June 2009 and January 2010. CONCLUSIONS: Installation of AIMS itself did not improve antibiotic compliance over that achieved with paper anesthesia records. However, real-time guidance and reminders through electronic messages generated by a computerized decision support system (Smart Anesthesia Messenger, or SAM) significantly improved compliance. With such a system a consistent compliance of >99% was achieved.
Anesthesia & Analgesia | 2014
Bala G. Nair; Mayumi Horibe; Shu Fang Newman; Wei Ying Wu; Gene N. Peterson; Howard A. Schwid
BACKGROUND:Intraoperative hypotension and hypertension are associated with adverse clinical outcomes and morbidity. Clinical decision support mediated through an anesthesia information management system (AIMS) has been shown to improve quality of care. We hypothesized that an AIMS-based clinical decision support system could be used to improve management of intraoperative hypotension and hypertension. METHODS:A near real-time AIMS-based decision support module, Smart Anesthesia Manager (SAM), was used to detect selected scenarios contributing to hypotension and hypertension. Specifically, hypotension (systolic blood pressure <80 mm Hg) with a concurrent high concentration (>1.25 minimum alveolar concentration [MAC]) of inhaled drug and hypertension (systolic blood pressure >160 mm Hg) with concurrent phenylephrine infusion were detected, and anesthesia providers were notified via “pop-up” computer screen messages. AIMS data were retrospectively analyzed to evaluate the effect of SAM notification messages on hypotensive and hypertensive episodes. RESULTS:For anesthetic cases 12 months before (N = 16913) and after (N = 17132) institution of SAM messages, the median duration of hypotensive episodes with concurrent high MAC decreased with notifications (Mann Whitney rank sum test, P = 0.031). However, the reduction in the median duration of hypertensive episodes with concurrent phenylephrine infusion was not significant (P = 0.47). The frequency of prolonged episodes that lasted >6 minutes (sampling period of SAM), represented in terms of the number of cases with episodes per 100 surgical cases (or percentage occurrence), declined with notifications for both hypotension with >1.25 MAC inhaled drug episodes (&dgr; = −0.26% [confidence interval, −0.38% to −0.11%], P < 0.001) and hypertension with phenylephrine infusion episodes (&dgr; = −0.92% [confidence interval, −1.79% to −0.04%], P = 0.035). For hypotensive events, the anesthesia providers reduced the inhaled drug concentrations to <1.25 MAC 81% of the time with notifications compared with 59% without notifications (P = 0.003). For hypertensive episodes, although the anesthesia providers’ reduction or discontinuation of the phenylephrine infusion increased from 22% to 37% (P = 0.030) with notification messages, the overall response was less consistent than the response to hypotensive episodes. CONCLUSIONS:With automatic acquisition of arterial blood pressure and inhaled drug concentration variables in an AIMS, near real-time notification was effective in reducing the duration and frequency of hypotension with concurrent >1.25 MAC inhaled drug episodes. However, since phenylephrine infusion is manually documented in an AIMS, the impact of notification messages was less pronounced in reducing episodes of hypertension with concurrent phenylephrine infusion. Automated data capture and a higher frequency of data acquisition in an AIMS can improve the effectiveness of an intraoperative clinical decision support system.
Anesthesiology | 2013
Bala G. Nair; Gene N. Peterson; Moni B. Neradilek; Shu Fang Newman; Elaine Y. Huang; Howard A. Schwid
Background:Reduced consumption of inhalation anesthetics can be safely achieved by reducing excess fresh gas flow (FGF). In this study the authors describe the use of a real-time decision support tool to reduce excess FGF to lower, less wasteful levels. Method:The authors applied a decision support tool called the Smart Anesthesia Manager™ (University of Washington, Seattle, WA) that analyzes real-time data from an Anesthesia Information Management System to notify the anesthesia team if FGF exceeds 1 l/min. If sevoflurane consumption reached 2 minimum alveolar concentration-hour under low flow anesthesia (FGF < 2 l/min), a second message was generated to increase FGF to 2 l/min, to comply with Food and Drug Administration guidelines. To evaluate the tool, mean FGF between surgical incision and the end of procedure was compared in four phases: (1) a baseline period before instituting decision rules, (2) Intervention-1 when decision support to reduce FGF was applied, (3) Intervention-2 when the decision rule to reduce flow was deliberately inactivated, and (4) Intervention-3 when decision rules were reactivated. Results:The mean ± SD FGF reduced from 2.10 ± 1.12 l/min (n = 1,714) during baseline to 1.60 ± 1.01 l/min (n = 2,232) when decision rules were instituted (P < 0.001). When the decision rule to reduce flow was inactivated, mean FGF increased to 1.87 ± 1.15 l/min (n = 1,732) (P < 0.001), with an increasing trend in FGF of 0.1 l/min/month (P = 0.02). On reactivating the decision rules, the mean FGF came down to 1.59 ± 1.02 l/min (n = 1,845). Through the Smart Anesthesia Messenger™ system, the authors saved 9.5 l of sevoflurane, 6.0 l of desflurane, and 0.8 l isoflurane per month, translating to an annual savings of
IEEE Transactions on Biomedical Engineering | 2013
Bala G. Nair; Shu Fang Newman; Gene N. Peterson; Howard A. Schwid
104,916. Conclusions:Real-time notification is an effective way to reduce inhalation agent usage through decreased excess FGFs.
The Joint Commission Journal on Quality and Patient Safety | 2012
Bala G. Nair; Gene N. Peterson; Shu Fang Newman; Wei Ying Wu; Vickie Kolios-Morris; Howard A. Schwid
Anesthesia information management systems (AIMS) are being increasingly used in the operating room to document anesthesia care. We developed a system, Smart Anesthesia ManagerTM (SAM) that works in conjunction with an AIMS to provide clinical and billing decision support. SAM interrogates AIMS database in near real time, detects issues related to clinical care, billing and compliance, and material waste. Issues and the steps for their resolution are brought to the attention of the anesthesia provider in real time through “pop-up” messages overlaid on top of AIMS screens or text pages. SAM improved compliance to antibiotic initial dose and redose to 99.3 ± 0.7% and 83.9 ± 3.4% from 88.5 ± 1.4% and 62.5 ± 1.6%, respectively. Beta-blocker protocol compliance increased to 94.6 ± 3.5% from 60.5 ± 8.6%. Inadvertent gaps (>;15 min) in blood pressure monitoring were reduced to 34 ± 30 min/1000 cases from 192 ± 58 min/1000 cases. Additional billing charge capture of invasive lines procedures worth
American Journal of Infection Control | 2017
Matthew Nottingham; Gene N. Peterson; Christopher D. Doern; Michelle Doll; Nadia Masroor; Kakotan Sanogo; Michael P. Stevens; Gonzalo Bearman
144,732 per year and 1,200 compliant records were achieved with SAM. SAM was also able to reduce wastage of inhalation anesthetic agents worth
Anesthesia & Analgesia | 2016
Bala G. Nair; Mayumi Horibe; Moni B. Neradilek; Shu Fang Newman; Gene N. Peterson
120,168 per year.
American Journal of Surgery | 2016
Meghan R. Flanagan; Carolyn C. Foster; Anneliese M. Schleyer; Gene N. Peterson; Samuel P. Mandell; Kristina E. Rudd; Byron D. Joyner; Thomas H. Payne
BACKGROUND Continuation of perioperative beta-blockers for surgical patients who are receiving beta-blockers prior to arrival for surgery is an important quality measure (SCIP-Card-2). For this measure to be considered successful, name, date, and time of the perioperative beta-blocker must be documented. Alternately, if the beta-blocker is not given, the medical reason for not administering must be documented. METHODS Before the study was conducted, the institution lacked a highly reliable process to document the date and time of self-administration of beta-blockers prior to hospital admission. Because of this, compliance with the beta-blocker quality measure was poor (-65%). To improve this measure, the anesthesia care team was made responsible for documenting perioperative beta-blockade. Clear documentation guidelines were outlined, and an electronic Anesthesia Information Management System (AIMS) was configured to facilitate complete documentation of the beta-blocker quality measure. In addition, real-time electronic alerts were generated using Smart Anesthesia Messenger (SAM), an internally developed decision-support system, to notify users concerning incomplete beta-blocker documentation. RESULTS Weekly compliance for perioperative beta-blocker documentation before the study was 65.8 +/- 16.6%, which served as the baseline value. When the anesthesia care team started documenting perioperative beta-blocker in AIMS, compliance was 60.5 +/- 8.6% (p = .677 as compared with baseline). Electronic alerts with SAM improved documentation compliance to 94.6 +/- 3.5% (p < .001 as compared with baseline). CONCLUSIONS To achieve high compliance for the beta-blocker measure, it is essential to (1) clearly assign a medical team to perform beta-blocker documentation and (2) enhance features in the electronic medical systems to alert the user concerning incomplete documentation.
Journal of Clinical Anesthesia | 2016
Katherine Grunzweig; Bala G. Nair; Gene N. Peterson; Mayumi Horibe; Moni B. Neradilek; Shu Fang Newman; Gail A. Van Norman; Howard A. Schwid; Wei Hao; E. Patchen Dellinger; Irl B. Hirsch
HighlightsThe anesthesia workstation is a reservoir for pathogenic organisms potentially associated with surgical site infections (SSIs).Carriers inoculated with a known concentration of either S. aureus, E. faecalis, or Acinetobacter baumannii. were placed on 22 high‐touch surfaces of the anesthesia workstation and exposed to UVC light using the Tru‐D UVC device.All experimental trials, compared to controls, exhibited a bioburden greater than 2 log versus controls, regardless of whether the surfaces received direct exposure to the UVC light or not. Background: Anesthesia workstations (AWs) are a reservoir for pathogenic organisms potentially associated with surgical site infections. This study examined the effectiveness of the Tru‐D SmartUVC device (Tru‐D LLC, Nashville, TN) on bioburden reduction (BR) on AWs. Methods: Strips of tissue inoculated with a known concentration of either Staphylococcus aureus, Enterococcus faecalis, or Acinetobacter sp were placed on 22 high‐touch surfaces of an AW. Half of the AW surfaces received direct ultraviolet (UV) light exposure and half received indirect exposure. Two inoculated strips, in sterile tubes outside of the room, represented the control. Trials were conducted on AWs in an operating room and a small room. Strips were placed in a saline solution, vortexed, and plated on blood agar to assess BR by the number of colony forming units. Results: All experimental trials, compared with controls, exhibited a BR >99%. There was a significantly greater reduction of E faecalis colony forming units in the operating room AW under direct exposure (P = .019) compared with indirect exposure. There was no significant difference in reduction when comparing AWs between rooms. Conclusion: Regardless of room size and exposure type, automated UV‐C treatment greatly influences BR on AW high‐touch surfaces. Hospitals instituting an automated UV‐C system as an infection prevention adjunct should consider utilizing it in operating rooms for BR as part of a horizontal infection prevention surgical site infection‐reduction strategy.