Circulation | 2000

First Clinical Experience With the DeBakey VAD Continuous-Axial-Flow Pump for Bridge to Transplantation

Georg Wieselthaler; Heinrich Schima; Michael Hiesmayr; Richard Pacher; Günther Laufer; George P. Noon; Michael E. DeBakey; Ernst Wolner

BACKGROUND A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. METHODS AND RESULTS Two male patients (ages 44 and 65 years) suffering from end-stage left heart failure were implanted with a DeBakey VAD axial-flow pump for use as a bridge to transplant. In the initial postoperative period, the mean pump flow was 3.9+/-0.5 L/min, which equals a mean cardiac index (CI) of 2.3+/-0.2 L. min(-1). m(-2). In both patients, the early postoperative phase was characterized by a completely nonpulsatile flow profile. However, with the recovery of heart function 8 to 12 days after implantation, increasing pulse pressures became evident, and net flow rose to 4.5+/-0.6 L/min, causing an increase of mean CI up to 2.7+/-0.2 L. min(-1). m(-2). Patients were mobilized and put through regular physical training. Hemolysis stayed in the physiological range and increased only slightly from 2. 1+/-0.8 mg/dL before surgery to 3.3+/-1.8 mg/dL 6 weeks after implantation. CONCLUSIONS The first clinical implants of the DeBakey VAD axial-flow pump have demonstrated the device to be a promising measure of bridge-to-transplant mechanical support.


Circulation | 2001

Mechanical Circulatory Support for Advanced Heart Failure

Mario C. Deng; Matthias Loebe; Aly El-Banayosy; Edoardo Gronda; Piet Jansen; Mario Viganò; Georg Wieselthaler; Bruno Reichart; Ettore Vitali; Alain Pavie; Thierry Mesana; Daniel Loisance; Dereck R. Wheeldon; Peer M. Portner

Background—Use of wearable left ventricular assist systems (LVAS) in the treatment of advanced heart failure has steadily increased since 1993, when these devices became generally available in Europe. The aim of this study was to identify in an unselected cohort of LVAS recipients those aspects of patient selection that have an impact on postimplant survival. Methods and Results—Data were obtained from the Novacor European Registry. Between 1993 and 1999, 464 patients were implanted with the Novacor LVAS. The majority had idiopathic (60%) or ischemic (27%) cardiomyopathy; the median age at implant was 49 (16 to 75) years. The median support time was 100 days (4.1 years maximum). Forty-nine percent of the recipients were discharged from the hospital on LVAS; they spent 75% of their time out of the hospital. For a subset of 366 recipients, for whom a complete set of data was available, multivariate analysis revealed that the following preimplant conditions were independent risk factors for survival after LV...


Journal of Heart and Lung Transplantation | 2010

Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial

Georg Wieselthaler; Gerry O′Driscoll; P. Jansz; Asghar Khaghani; M. Strueber

BACKGROUND Third-generation rotary blood pumps have magnetically levitated rotors that eliminate mechanical wear over the years. Together with their potential for miniaturization, these pumps seem suitable for long-term support of patients with a wide range of body surface areas (BSA). Recently, the novel HVAD pump (HeartWare Inc, Framingham, MA), a miniaturized centrifugal pump with a hydrodynamic, magnetically levitated rotor, became ready for clinical application. METHODS In a multi-institutional trial in Europe and Australia, 23 patients (mean age, 47.9 ± 12 years) in end-stage heart failure were enrolled in 5 centers. The primary end point of the bridge-to-transplant study was survival to heart transplant or survival to 180 days on the device, whichever occurred first. Follow-up data at 1 year are presented. The small size of the device allows for intrapericardial placement of the pump. RESULTS Implant procedures were generally fast and uneventful. Mean duration of support was 167 ± 143 days (range, 13-425 days), and mean blood flow provided by the pump was 6.1 ± 1.1 liters/min. At the 180-day end point, 2 patients had undergone successful transplant at 157 and 175 days, 2 patients died while on the device, and 19 patients continued pump support for more than 180 days. Actuarial survival after 6 months was 91% and was 86% at the 1-year follow-up. CONCLUSIONS The design of the HVAD pump enables a quick and less invasive implantation. The results to date demonstrate satisfactory long-term survival with excellent quality of life in this cohort of 23 patients of the initial multi-institutional Conformité Européene (CE) mark trial.


The Annals of Thoracic Surgery | 2009

Renal Function and Outcome After Continuous Flow Left Ventricular Assist Device Implantation

Sigrid E. Sandner; Daniel Zimpfer; Philipp Zrunek; Angela Rajek; Heinrich Schima; Daniela Dunkler; Michael Grimm; Ernst Wolner; Georg Wieselthaler

BACKGROUND Renal dysfunction as a risk factor with the use of left ventricular assist devices (LVAD) is controversial. We determined the effect of renal function on outcomes after continuous flow LVAD implantation. METHODS Eighty-six patients with advanced heart failure undergoing continuous flow LVAD implantation as bridge to transplantation from November 1998 to July 2007 were retrospectively analyzed. Renal function was assessed using the Modification of Diet in Renal Disease study-derived glomerular filtration rates (GFR [mL x min(-1) x 1.73 m(-2)]). Patients were categorized into two groups based on pre-LVAD GFR: those with normal renal function (GFR > 60, n = 46), and those with renal dysfunction (GFR < 60, n = 40). RESULTS Post-LVAD survival at 1, 3, and 6 months for GFR greater than 60 was 91.3%, 79.9%, 72.6%, respectively, and for GFR less than 60, it was 92.5%, 66.5%, 47.9%, respectively (p = 0.038). Bridge-to-transplant rate was lower for GFR less than 60 than for GFR greater than 60 (40.0% versus 63.0%, p = 0.033). For GFR less than 60, GFR improved on LVAD support: implant to month 6, 41.7 +/- 11.5 to 62.7 +/- 25.0 (p = 0.021). Post-LVAD survival was improved in GFR less than 60 patients who after LVAD implantation recovered renal function to GFR greater than 60 (p < 0.001). Patients with post-LVAD renal failure had significantly lower post-LVAD survival regardless of pre-LVAD renal function (p < 0.001). CONCLUSIONS Patients with renal dysfunction have poorer outcomes after continuous flow LVAD implantation. However, renal function improves after LVAD implantation and is associated with improved survival. Our data underscore the importance of end-organ function in patient selection for LVAD therapy.


European Journal of Cardio-Thoracic Surgery | 2009

European experience of DuraHeart™ magnetically levitated centrifugal left ventricular assist system

Michiel Morshuis; Aly El-Banayosy; Latif Arusoglu; Reiner Koerfer; Roland Hetzer; Georg Wieselthaler; Alain Pavie; Chisato Nojiri

OBJECTIVE The DuraHeart (Terumo Heart, Inc., Ann Arbor, Michigan, USA) is the worlds first approved magnetically levitated centrifugal left ventricular assist system designed for long-term circulatory support. We report the clinical outcomes of 68 patients implanted with the DuraHeart as a bridge to cardiac transplantation in Europe. METHODS Sixty-eight patients with advanced heart failure (six females), who were eligible for cardiac transplantation were implanted with the DuraHeart between January 2004 and July 2008. Median age was 58 (range: 29-74) years with 31% over 65 years. Thirty-three of these patients received the device as a part of the European multi-center clinical trial. Survival analyses were conducted for 68 patients and other safety and performance data were analyzed based on 33 trial patients. RESULTS Mean support duration was 242+/-243 days (range: 19-1148, median: 161) with a cumulative duration of 45 years. Thirty-five patients (51%) remain ongoing, 18 transplanted, 1 explanted, and 14 died during support with a median time to death of 62 days. The Kaplan-Meier survival rate during support was 81% at 6 months and 77% at 1 year. Of the 13 patients (21%) supported for >1 year, 4 supported for >2 years, 1 supported >3 years, 2 transplanted, 2 died, and 9 ongoing with a mean duration of 744+/-216 days (range: 537-1148, median: 651). Major adverse events included driveline/pocket infection, stroke, bleeding, and right heart failure. There was no incidence of pump mechanical failure, pump thrombosis, or hemolysis. CONCLUSIONS The DuraHeart was able to provide safe and reliable long-term circulatory support with an improved survival and an acceptable adverse event rate in advanced heart failure patients who were eligible for transplantation.


The Annals of Thoracic Surgery | 2009

Platelet Dysfunction in Outpatients With Left Ventricular Assist Devices

Barbara Steinlechner; Martin Dworschak; Beatrice Birkenberg; Monika Duris; Petra Zeidler; Henrik Fischer; Ljubisa Milosevic; Georg Wieselthaler; Ernst Wolner; Peter Quehenberger; Bernd Jilma

BACKGROUND Thromboembolic and bleeding complications in outpatients with a left ventricular assist device are common and can be detrimental. A meticulous balance between anticoagulant and procoagulant factors is therefore crucial. However, in contrast to routinely performed plasmatic coagulation tests, platelet function is hardly ever monitored although recent reports indicated platelet dysfunction. We therefore differentially evaluated platelet function with four commonly used point-of-care devices. METHODS In a cross-sectional design platelet function was assessed in 12 outpatients and 12 healthy matched volunteers using thrombelastography platelet mapping, thromboelastometry, platelet function analyzer, and a new whole blood aggregometer (Multiplate). RESULTS Phenprocoumon produced an international normalized ratio of 3.5. It was associated with a twofold prolongation in the thromboelastometry clotting time (p < 0.001). Platelet function under high shear was severely compromised: collagen adenosine diphosphate closure times were 2.5-fold longer in patients than in volunteers (p < 0.001), and 50% of patients had maximal collagen adenosine diphosphate closure time values. Although antigen levels of von Willebrand factor were 80% higher in patients (p < 0.001), von Willebrand factor-ristocetin was subnormal in 5 of 12 patients. Ristocetin-induced aggregation was also threefold higher in volunteers (p < 0.001), indicating an additional functional defect of platelets affecting the glycoprotein Ib-von Willebrand factor axis. The von Willebrand factor multimer pattern in patients also appeared abnormal. CONCLUSIONS Multimodal antiplatelet monitoring showed markedly impaired platelet function in patients with a left ventricular assist device. Platelet dysfunction under high shear rates and abnormal ristocetin-induced aggregation is only partly attributable to low von Willebrand factor activity. These findings resemble the acquired von Willebrand syndrome that is associated with microaggregate formation and enhanced bleeding.


Journal of Heart and Lung Transplantation | 2008

Renal Function After Implantation of Continuous Versus Pulsatile Flow Left Ventricular Assist Devices

Sigrid E. Sandner; Daniel Zimpfer; Philipp Zrunek; Daniela Dunkler; Heinrich Schima; Angela Rajek; Michael Grimm; Ernst Wolner; Georg Wieselthaler

BACKGROUND This study was designed to determine the effect of continuous vs pulsatile flow devices on renal function after left ventricular assist device (LVAD) implantation. METHODS Ninety-two patients undergoing LVAD implantation as bridge-to-transplant therapy were retrospectively analyzed. Patients receiving continuous flow devices (n = 63, 68.5%) were compared with patients receiving pulsatile flow devices (n = 29, 31.5%). Renal function was assessed by 2 calculated glomerular filtration rates (GFR) using the Modification of Diet in Renal Disease (MDRD)-derived GFR (ml/min/1.73 m(2)) and the Cockcroft-Gault-derived creatinine clearance (CrCl, ml/min). RESULTS Mean GFR/CrCl was comparable between the groups at LVAD implantation, in the post-implantation period, and at transplantation. Both groups had a significant increase in mean GFR at Week 1 post-implantation (continuous, 59.4 +/- 22.8 to 76.4 +/- 38.6, p = 0.001; pulsatile, 52.5 +/- 21.1 to 69.2 +/- 34.7; p = 0.007), Week 4 (continuous, 59.9 +/- 23.0 to 84.3 +/- 32.9; p < 0.001; pulsatile, 50.3 +/- 21.1 to 79.9 +/- 38.7, p = 0.007), and Week 12 (continuous, 60.3 +/- 23.1 to 75.3 +/- 30.2, p = 0.004; pulsatile, 55.5 +/- 23.1 to 74.2 +/- 27.2, p = 0.037) that was also seen with the Cockcroft-Gault-calculated CrCl. No significant increase occurred in mean GFR/CrCl to transplantation. Incidence of post-implantation renal failure was comparable between the groups (continuous, 38.1%; pulsatile, 31.0%; p = 0.512). CONCLUSIONS After LVAD implantation, patients with continuous flow devices and patients with pulsatile flow devices have comparable renal function.


Asaio Journal | 2006

Neurocognitive function in patients with ventricular assist devices: a comparison of pulsatile and continuous blood flow devices.

Daniel Zimpfer; Georg Wieselthaler; Martin Czerny; Richard Fakin; Dominik Haider; Philipp Zrunek; Wilfried Roethy; H. Schima; Ernst Wolner; Michael Grimm

The effect of successful ventricular assist device (VAD) implantation on neurocognitive function in terminal heart failure is uncertain. Additionally, the different impact of continuous versus pulsatile blood flow devices is unknown. A total of 29 patients (mean age 53 years), surviving implantation of a ventricular assist device as bridge to transplantation were prospectively followed (continuous flow: Micromed DeBakey, n = 11; pulsatile flow: Thoratec and Novacor, n = 18). Normative data were obtained in 40 age- and sex-matched healthy subjects (mean age 54 years). Neurocognitive function was objectively measured by means of cognitive P300 auditory evoked potentials before operation (baseline), at intensive care unit (ICU) discharge, and at the 8-week and 12-week follow-up. Before implantation of the VAD, cognitive P300 evoked potentials were impaired (prolonged) compared with age- and sex-matched healthy subjects (p < 0.001). After successful VAD implantation, P300 evoked potentials markedly improved compared with before operation (ICU discharge, p = 0.007; 8-week follow-up, p = 0.022; 12-week follow-up, p < 0.0001). Importantly, there was no difference between continuous and pulsatile VADs (before operation, p = 0.676; ICU discharge, p = 0.736; 8-week follow-up, p = 0.911 and 12-week follow-up, p = 0.397; respectively). Nevertheless, P300 peak latencies did not fully normalize at 12-week follow-up compared with healthy subjects (p = 0.012). Successful VAD implantation improves neurocognitive impairment in patients with terminal heart failure. Importantly, this effect is independent of the type of VAD (pulsatile vs. continuous blood flow).


The Annals of Thoracic Surgery | 2002

Cognitive Deficit After Aortic Valve Replacement

Daniel Zimpfer; Martin Czerny; Juliane Kilo; Marie-Theres Kasimir; Christian Madl; Ludwig Kramer; Georg Wieselthaler; Ernst Wolner; Michael Grimm

BACKGROUND Impairment of cognitive brain function after coronary artery bypass grafting (CABG) is well known. In contrast the potential neurocognitive damage related to aortic valve replacement (AVR) is uncertain. METHODS In this contemporary case-matched control study we followed 30 patients (mean age 70 years) receiving isolated AVR with a biological prosthesis. A cohort of sex-and age-matched patients (n = 30, mean age 70 years) receiving CABG with cardiopulmonary bypass served as controls. Cognitive brain function was measured by means of auditory evoked P300 potentials (peak latencies, ms) before the operation and 7 days and 4 months after the operation. Additionally, two standard psychometric tests (Mini-Mental State Examination and the Trailmaking Test A) were performed. RESULTS In preoperative measures there was no difference between patients undergoing AVR and patients undergoing CABG (AVR 378 +/- 37 ms, CABG 374 +/- 32 ms, p = 0.629). One week after surgery P300 peak latencies were prolonged (impaired) in both groups compared with preoperative values (AVR 405 +/- 43 ms, p = 0.001; CABG 398 +/- 44 ms, p = 0.004). At this point of follow-up there was no difference between the groups (p = 0.607). Finally, 4 months after surgery P300 auditory evoked potentials returned to normal in the CABG group (380 +/- 24 ms, p = 0.940) while in contrast in the valve group they continued to become prolonged (worsened) compared with preoperative values (410 +/- 47 ms, p = 0.005). At this time of follow-up P300 peak latencies were prolonged in AVR patients as compared with CABG patients (p = 0.032). The Trailmaking Test A and Mini-Mental State Examination failed to discriminate any difference. CONCLUSIONS Four-month impairment of cognitive brain function is more pronounced in patients undergoing biological AVR as compared with age-matched control patients undergoing CABG. Further studies are needed to clarify the potential pathologic mechanisms causing an ongoing cognitive impairment in patients with biological aortic valve prostheses.


The Annals of Thoracic Surgery | 2001

Lessons learned from the first clinical implants of the DeBakey ventricular assist device axial pump: a single center report

Georg Wieselthaler; Heinrich Schima; Andrea Lassnigg; Martin Dworschak; Richard Pacher; Michael Grimm; Ernst Wolner

BACKGROUND The bridge to transplantation with pulsatile mechanical assist devices became a standard procedure for patients deteriorating on the waiting list. Recently, continuous flow axial impeller pumps were introduced to clinical application offering new advantages. METHODS From November 1998 till September 2000, 6 male patients (mean age 53 plus or minus 11 years) with end-stage left heart failure were implanted with a DeBakey ventricular assist device (VAD) axial-flow pump for bridge to transplantation. RESULTS Three patients were successfully transplanted after 74, 115, and 117 days, respectively. Two other patients died after 25 and 133 days. One patient is still on the device after 108 days. Because of modification of the implantation technique after the first 2 patients, mean pump-flow within the first 3 weeks was increased from 4.3 +/- 0.6 L/min to 6.7 +/- 0.3 L/min. Patients were put on regular bicycle-ergometer training and improved their exercise capacities up to a mean maximum oxygen consumption of 20.2 mL/kg/min. CONCLUSIONS Initial implants of the DeBakey VAD demonstrated support properties comparable to pulsatile pumps but without significant restrictions for extended use.

Collaboration


Dive into the Georg Wieselthaler's collaboration.

Top Co-Authors

Avatar

Ernst Wolner

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar

Heinrich Schima

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar

Michael Grimm

Innsbruck Medical University

View shared research outputs
Top Co-Authors

Avatar

H. Schima

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar

Michael Vollkron

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Daniel Zimpfer

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar

L. Huber

University of Vienna

View shared research outputs
Top Co-Authors

Avatar

Günther Laufer

Medical University of Vienna

View shared research outputs
Top Co-Authors

Avatar

Wilfried Roethy

Medical University of Vienna

View shared research outputs
Researchain Logo
Decentralizing Knowledge