Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where George P. Teitelbaum is active.

Publication


Featured researches published by George P. Teitelbaum.


Journal of Computer Assisted Tomography | 1990

Gadolinium enhanced MR imaging of vascular stents.

Alan H. Matsumoto; George P. Teitelbaum; Mark J. Carvlin; Klemens H. Barth; Michael Savin; Ernst P. Strecker

The feasibility of obtaining in-plane magnetic resonance (MR) vascular images in the presence of a vascular stent and the value of infusing an MR contrast agent during imaging was assessed. Coronal and sagittal MR imaging at 1.5 T was performed on six dogs with tantalum aortic stents using single-section gradient echo (GRE) imaging and MR angiography techniques before and during intravenous infusion of gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA). In-plane gradient echo (GRE) imaging and MR angiography clearly showed flow within the stented vessel as increased signal, with a minimum amount of stent-related artifact. Infusion of Gd-DTPA significantly increased the signal of flowing blood and allowed for better delineation of the stented aortic lumina. Our results demonstrate that in-plane GRE imaging and MR angiography can potentially be used as noninvasive methods for evaluating vascular patency in the presence of MR-compatible endovascular devices. In addition, Gd-DTPA infusion during MR vascular imaging clearly enhances the definition of flowing blood in the lumina of stented vessels.


CardioVascular and Interventional Radiology | 1989

Evaluation of ferromagnetism and magnetic resonance imaging artifacts of the Strecker tantalum vascular stent

George P. Teitelbaum; Michael W. Raney; Mark J. Carvlin; Alan H. Matsumoto; Klemens H. Barth

A woven tantalum vascular stent (Strecker stent) was tested for ferromagnetism at 4.7 T and underwent magnetic resonance imaging (MRI)in vitro andin vivo at 1.5 T to evaluate the production of magnetic susceptibility artifacts. No ferromagnetism was detected. Spin-echo, phase reconstruction, and gradient echo images revealed a low level of susceptibility artifacts bothin vitro andin vivo. Our findings demonstrate the feasibility of using MRI to evaluate blood vessels noninvasively following tantalum stent placement.


Journal of Thoracic Imaging | 1989

Magnetic resonance imaging of cardiac sarcomas

Alyssa T. Watanabe; George P. Teitelbaum; Robert Henderson; William G. Bradley

Two patients with cardiac sarcomas were evaluated with magnetic resonance imaging (MRI). In both cases, MRI provided more information regarding the extent of the tumor than computed tomography, two-dimensional echocardiography, or angiography.


CardioVascular and Interventional Radiology | 1989

Isolated popliteal vein entrapment

Martha C. Nelson; George P. Teitelbaum; Alan H. Matsumoto; Margaret A. Stull

We present two cases of isolated popliteal vein entrapment caused by the lateral head of the gastrocnemius muscle confirmed by both venography and magnetic resonance imaging of the knee.


CardioVascular and Interventional Radiology | 1990

The use of double guidewires through a single vascular sheath for obtaining profunda femoris arterial access: Technical note

Alexander J. Zito; George P. Teitelbaum; Alan H. Matsumoto; Klemens H. Barth

We describe a double guidewire/single vascular sheath technique that facilitates dilatation of stenotic lesions within both the superficial femoral and profunda femoris arteries following a single antegrade common femoral arterial puncture. Such a technique prevents inadvertent loss of vascular access during maneuvers to catheterize the profunda femoris artery or the superficial femoral artery. Angioplasty within the superficial femoral artery with simultaneous safety-wire placement within the profunda femoris artery has been described previously, but we present, in this technical note, successful profunda femoral angioplasty with the safety wire within the superficial femoral artery.


CardioVascular and Interventional Radiology | 1989

Triple catheter aortoiliac angioplasty in a patient with a horseshoe kidney: Technical note

Alan H. Matsumoto; Phillip A. Baum; Klemens H. Barth; George P. Teitelbaum

A method is described for protecting a nonstenotic anomalous artery to the left-lower pole of a horseshoe kidney that originated from a stenotic left common iliac artery. Using a triple catheter technique, injury to this anomalous renal artery was prevented while using “kissing balloons” to dilate bilateral proximal common iliac artery stenoses.


CardioVascular and Interventional Radiology | 1989

Spontaneous rupture of a lower extremity varix: case report

George P. Teitelbaum; Paul S. Davis

A case of spontaneous hemorrhage from a lower extremity varix is presented. The diagnosis was made by venography. This prompted emergent surgical repair of the varix.


American Journal of Roentgenology | 1989

MR imaging of neurocysticercosis

George P. Teitelbaum; Ronald J. Otto; Mimi Lin; Alyssa T. Watanabe; Margaret A. Stull; Herbert J. Manz; William G. Bradley


American Journal of Roentgenology | 1989

Normal variations in MR imaging of the knee: appearance and frequency.

Alyssa T. Watanabe; Bc Carter; George P. Teitelbaum; Ll Seeger; William G. Bradley


Radiology | 1990

Flexible tantalum stents implanted in aortas and iliac arteries: effects in normal canines.

Klemens H. Barth; Renu Virmani; Ernst P. Strecker; Michael Savin; David Lindisch; Alan H. Matsumoto; George P. Teitelbaum

Collaboration


Dive into the George P. Teitelbaum's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge