Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Gerd Rundström is active.

Publication


Featured researches published by Gerd Rundström.


Lab on a Chip | 2008

Silane–dextran chemistry on lateral flow polymer chips for immunoassays

Christina Jönsson; Magnus Aronsson; Gerd Rundström; Christer Pettersson; Ib Mendel-Hartvig; Jimmy Bakker; Erik Martinsson; Bo Liedberg; Brian D. MacCraith; Ove Öhman; Jonas Melin

The prognosis for patients suffering from cardiovascular and many other diseases can be substantially improved if diagnosed at an early stage. High performance diagnostic testing using disposable microfluidic chips can provide a platform for realizing this vision. Amic AB (Uppsala, Sweden) has developed a new microfluidic test chip for sandwich immunoassays fabricated by injection molding of the cycloolefin-copolymer Zeonor. A highly ordered array of micropillars within the fluidic chip distributes the sample solution by capillary action. Since wetting of the pillar array surface is the only driving force for liquid distribution precise control of the surface chemistry is crucial. In this work we demonstrate a novel protocol for surface hydrophilization and antibody immobilization on cycloolefin-copolymer test chips, based on direct silanisation of the thermoplastic substrate. Dextran is subsequently covalently coupled to amino groups, thus providing a coating with a low contact angle suitable for antibody immobilization. The contact angle of dextran coated chips is stable for at least two months, which enables production of large batches that can be stored for extended periods of time. We demonstrate the utility of the presented platform and surface chemistry in a C-reactive protein assay with a detection limit of 2.6 ng ml(-1), a dynamic range of 10(2) and a coefficient of variance of 15%.


Analytical Biochemistry | 2011

A multiplexed point-of-care assay for C-reactive protein and N-terminal pro-brain natriuretic peptide.

Jonas Melin; Gerd Rundström; Christer Peterson; Jimmy Bakker; Brian D. MacCraith; Mike Read; Ove Öhman; Christina Jönsson

Several new plasma protein biomarkers have been associated with increased risk of cardiovascular events. It would be of great value if sets of these markers could be measured in a multiplexed format at point-of-care settings. A major challenge is the extremely wide concentration range in which different plasma biomarkers are present. Two promising biomarkers for cardiac risk prediction are C-reactive protein (CRP) and N-terminal pro-brain natriuretic peptide (NTproBNP). The concentrations of these markers can differ by more than six orders of magnitude. Here we present a chip-based multiplexed assay for CRP and NTproBNP. The high-concentration analyte, CRP, is analyzed in a competitive format, whereas the low-concentration analyte, NTproBNP, is analyzed in a sandwich format. This allows concurrent measurement of the two analytes in a single multiplexed assay. The dynamic ranges for the two assays were optimized to match the relevant serum concentration ranges; thus, no dilutions were needed. Both assays exhibit good precision (5-15% in the clinically relevant concentration ranges), and the limit of detection for the NTproBNP assay was 5 ng/L. Patient plasma samples were used for comparison with clinical methods, resulting in coefficients of determination (R(2)) of 0.9762 and 0.9606 for NTproBNP and CRP, respectively.


Journal of Neurosurgery | 1989

S-100 protein and neuron-specific enolase in CSF after experimental traumatic or focal ischemic brain damage

H.-G. Hårdemark; Nils Ericsson; Zbigniew Kotwica; Gerd Rundström; Ib Mendel-Hartvig; Yngve Olsson; Sven Påhlman; Lennart Persson


Archive | 2002

Multi-analyte assay device with multi-spot detection zone

Ib Mendel-Hartvig; Rune Björkman; Gerd Rundström


Clinical Chemistry | 2006

Lateral Flow Immunoassay Using Europium (III) Chelate Microparticles and Time-Resolved Fluorescence for Eosinophils and Neutrophils in Whole Blood

Gerd Rundström; Ann Jonsson; Ola Mårtensson; Ib Mendel-Hartvig; Per Venge


Archive | 1998

Analytical method comprising addition in two or more positions and a device and test kit therefor

Ib Mendel-Hartvig; Ilya Zelikman; Gerd Rundström


Archive | 2010

Amplified labeled conjugate for use in immunoassays

Gerd Rundström; Ib Mendel-Hartvig


Archive | 2009

Method for the analysis of circulating antibodies

Ib Mendel-Hartvig; Christer Pettersson; Gerd Rundström


Archive | 2010

Verstärkt markiertes Konjugat zur Verwendung bei Immuntests

Gerd Rundström; Ib Mendel-Hartvig


Archive | 2009

Verfahren zur Analyse von umlaufenden Antikörpern

Ib Mendel-Hartvig; Christer Pettersson; Gerd Rundström

Collaboration


Dive into the Gerd Rundström's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jonas Melin

Dublin City University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yngve Olsson

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge