Gersinei Carlos de Freitas
Universidade Federal de Goiás
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Gersinei Carlos de Freitas.
Journal of Applied Oral Science | 2009
Lawrence Gonzaga Lopes; Alfeu da Veiga Jardim Filho; João Batista de Souza; Denilson Rabelo; Eduardo Batista Franco; Gersinei Carlos de Freitas
The purpose of this study was to evaluate the sorption and solubility of a composite resin (TPH3; Dentsply) cured with halogen light due to different storage media and curing modes. The methodology was based on the ISO 4049 standard. Two independent groups were established according to the storage time (7 days-G1; 60 days-G2). A stainless steel mould (2 mm x 8 mm ø) was used. The selected curing modes were: I (Conventional - C): 40s - 600 mW/cm2; II (Pulse I - PD): 3 s - 200 mW/cm2 + 2 min (delay) + 39 s - 600 mW/cm2; III (Pulse II): 10 s - 200 mW/cm2 + 2 min (delay) + 37 s - 600 mW/cm2; IV (Pulse III): 3 s- 600 mW/cm2 + 2 min (delay) + 37 s -600 mW/cm2. The media used were: distilled water, 75% ethanol and 100% chlorophorm. Five repetitions were made for each group. The specimens were placed in a desiccator at 37°C for 24 h and, after that, at 23°C for 1 h to be weighed until a constant mass (m1) was obtained. The discs were immersed separately into the 3 media for 7 days (G1) and 60 days (G2), and thereafter reweighed (m2). The reconditioning in the desiccator was done until a constant mass (m3) was obtained. Sorption and solubility were calculated and the data of G1 and the sorption data of G2 were subjected to two-way ANOVA and Tukeys tests (p=0.05). The solubility data of G2 were analyzed by Kruskal-Wallis test (p=0.05). For G1 and G2, no statistically significant differences were found in sorption among curing techniques (p>0.05). The solubility values were negative, which means that there was mass gain. Regarding the storage media, in G2 chlorophorm had the highest sorption values. It may be concluded that the curing modes (C and PD I, II and III) did not affect the sorption of the tested composite resin. However, different storage media influenced sorption behavior. The solubility test demonstrated negative data, masking the real solubility.
Revista Odontológica do Brasil Central | 2010
João Batista de Souza; Paula Cicília Faquim Rodrigues; Lawrence Gonzaga Lopes; Adérico Santana Guilherme; Gersinei Carlos de Freitas; Francine do Couto Lima Moreira
RSBO Revista Sul-Brasileira de Odontologia | 2013
Laís Santos Gonçalves; Mércia Bráulio Gonçalves; Marília Morais Martins; Gersinei Carlos de Freitas; Lawrence Gonzaga Lopes; Terezinha Jesus Esteves Barata
Scientific Investigation in Dentistry | 2017
Mauro de Melo; Raulino Naves Borges; Gersinei Carlos de Freitas
Scientific Investigation in Dentistry | 2017
Mauro de Melo; André do Valle Linch de Faria; Bárbara Morais Arantes; Raulino Naves Borges; Gersinei Carlos de Freitas
Scientific Investigation in Dentistry | 2017
Raulino Naves Borges; Mauro de Melo; Gersinei Carlos de Freitas; João Batista de Souza; Taís Guedes Melo e Alvim; Jéssica Karla Maia Zago
Revista Odontológica do Brasil Central | 2017
Raulino Naves Borges; Mauro de Melo; Gersinei Carlos de Freitas; Taís Guedes Melo e Alvim; Jéssica Karla Maia Zago
Revista Odontológica do Brasil Central | 2017
Gersinei Carlos de Freitas; Raulino Naves Borges; Mauro de Melo; João Batista de Souza; Taís Guedes Melo e Alvim
Revista Odontológica do Brasil Central | 2017
Julyana Dumas Santos Silva; Ana Clara Freitas de Menezes Bandeira; Marielly Lopes da Cunha; Ana Paula Rodrigues Magalhães; Gersinei Carlos de Freitas; Lawrence Gonzaga Lopes
Revista Odontológica do Brasil Central | 2017
Gersinei Carlos de Freitas; Isadora Carneiro Pereira Machado; Amanda Pedrosa Oliveira; Amanda Vessoni Barbosa Kasuya; Terezinha Jesus Esteves Barata