Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Giacomo Davide Edoardo Papini is active.

Publication


Featured researches published by Giacomo Davide Edoardo Papini.


European Journal of Radiology | 2011

Optimizing dose and administration regimen of a high-relaxivity contrast agent for myocardial MRI late gadolinium enhancement

Francesco Secchi; Giovanni Di Leo; Giacomo Davide Edoardo Papini; Francesca Giacomazzi; Marisa Di Donato; Francesco Sardanelli

OBJECTIVES To investigate the time-course of late gadolinium enhancement of infarcted myocardium using gadobenate dimeglumine at different dosages and administration regimens. MATERIALS AND METHODS After institutional review board approval and informed consent, we studied 13 patients (aged 63±11 years) with chronic myocardial infarction. They underwent two gadobenate dimeglumine-enhanced MR examinations (interval 24-48 h) using short-axis inversion-recovery gradient-echo sequences, with the following two different protocols, in randomized order: 0.05 mmol/kg and imaging at the 2.5th, 5th, 7.5th and 10th minute plus 0.05 mmol/kg and imaging at the 12.5th, 15th, 17.5th and 20th minute; the same as before but using 0.1 mmol/kg for both contrast injections. Contrast-to-noise ratios (CNRs) between infarcted myocardium, non-infarcted myocardium and left ventricle cavity were calculated for each time-point (2.5-min steps). Friedman ANOVA was used for comparing the CNR time-course; Wilcoxon test for comparing CNR at the 10th and the 20th minute. RESULTS The CNR between infarcted and non-infarcted myocardium obtained at the 20th minute with 0.05 plus 0.05 mmol/kg resulted significantly higher than that obtained at the 10th minute with 0.05 mmol/kg (P=0.033) while not significantly different from that obtained at the 10th (0.1mm/kg) or at the 20th minute with 0.1 plus 0.1 mmol/kg. The CNR between infarcted myocardium and the left ventricle cavity obtained at the 20th minute with 0.05 plus 0.05 mmol/kg resulted significantly higher than all other measured values (P≤0.017). CONCLUSION Using gadobenate dimeglumine, 0.05 plus 0.05 mmol/kg allows for a higher CNR between infarcted myocardium and the left ventricle cavity allowing for reliable assessment of the sub-endocardial infarctions.


European Journal of Radiology | 2014

Less is better? Intraindividual and interindividual comparison between 0.075 mmol/kg of gadobenate dimeglumine and 0.1 mmol/kg of gadoterate meglumine for cranial MRI

Katia Khouri Chalouhi; Giacomo Davide Edoardo Papini; Michele Bandirali; Luca Maria Sconfienza; Giovanni Di Leo; Francesco Sardanelli

PURPOSE To retrospectively compare a reduced dose (RD) (0.075 mmol/kg) of gadobenate dimeglumine (RD-gadobenate) with standard single dose (SSD) (0.1 mmol/kg) of gadoterate meglumine (SSD-gadoterate) for cranial MRI. MATERIALS AND METHODS Thirty-one patients (12 males; aged 52 ± 16 years) underwent cranial MRI with SSD-gadoterate and repeated the examination with RD-gadobenate after a median interval of 10 months. Signal-to-noise ratio (SNR) was obtained on contrast-enhanced images for enhancing lesions (n=10) as well as for right and left transverse venous sinuses, internal carotid arteries, and parotid glands. Moreover, a consecutive series of 100 cranial MRI with SSD-gadoterate (49 males; aged 51 ± 19 years) was compared with a consecutive series of 100 cranial MRI with RD-gadobenate (45 males; aged 54 ± 18 years). Two blinded neuroradiologists (R1, R2) judged contrast enhancement as sufficient, good, or optimal. Wilcoxon, Mann-Whitney, χ(2), and Cohen κ statistics were used. RESULTS At intraindividual analysis, median SNR ranged 57-88 for SSD-gadoterate and 79-99 for RD-gadobenate, the latter being systematically higher, the difference being significant for both transverse venous sinuses (p ≤ 0.011), not significant for both internal carotid arteries and both parotid glands, and enhancing lesions (p ≤ 0.101). The two series of interindividual analysis were not significantly different for gender/age (p>0.415). Contrast enhancement was optimal in 59% (R1) and 76% (R2) of patients using RD-gadobenate, in 39% (R1) and 49% (R2) of patients using SSD-gadoterate (p ≤ 0.016), with substantial reproducibility (κ ≥ 0.606). CONCLUSION Both analyses showed an equal or better contrast enhancement when using RD-gadobenate compared to SSD-gadoterate for routine cranial MRI. The high relaxivity of gadobenate allowed for a 25% dose reduction.


European Journal of Radiology | 2011

Evaluation of inflammatory status of atherosclerotic carotid plaque before thromboendarterectomy using delayed contrast-enhanced subtracted images after magnetic resonance angiography

Giacomo Davide Edoardo Papini; Giovanni Di Leo; Stefania Tritella; Giovanni Nano; Biagio Cotticelli; Claudio Clemente; Domenico G. Tealdi; Francesco Sardanelli

OBJECTIVE To investigate the correlation among carotid plaque contrast enhancement (CPCE) at MRI, inflammatory cell infiltration (ICI) at histopathology, and carotid stenosis degree. MATERIALS AND METHODS Twenty-eight patients (19 males; mean age 67±9 years) scheduled for thromboendarterectomy prospectively underwent 1.5-T MR imaging using: (a) axial T1-weighted gradient-echo (T1wGRE) sequence centered on carotid bifurcations; (b) contrast-enhanced MR angiography (CE-MRA) with 0.1 mmol/kg of gadobenate dimeglumine; (c) enhanced axial T1wGRE sequence as in (a), 3 min after contrast injection. A three-point score system (absent, focal, wide) was used to assess CPCE on native and subtracted MRI images (c minus a) and ICI at histopathology. Carotid stenosis degree was determined on CE-MRA. RESULTS Six CPCE studies were discarded due to patient movement. In the remaining 22 studies, CPCE was absent, focal and wide in 13, 6 and 3 cases, respectively; ICI was absent, focal and wide in 13, 7 and 2 cases, respectively (k=0.57). On CE-MRA 21/28 stenoses were severe and 7/28 moderate. There was no correlation either with ICI (p=1.000, n=28) or CPCE (p=0.747, n=22). CONCLUSION The correlation between CPCE and ICI suggests a role for CPCE as an independent marker of plaque inflammation.


European Journal of Radiology | 2009

Evaluation of carotid vessel wall enhancement with image subtraction after gadobenate dimeglumine-enhanced MR angiography

Francesco Sardanelli; Giovanni Di Leo; Alberto Aliprandi; Nicola Flor; Giacomo Davide Edoardo Papini; Luca Roccatagliata; Biagio Cotticelli; Giovanni Nano; Gianpaolo Cornalba

OBJECTIVES This study was aimed at testing the value of image subtraction for evaluating carotid vessel wall enhancement in contrast-enhanced MR angiography (MRA). MATERIALS AND METHODS IRB approval was obtained. The scans of 81 consecutive patients who underwent carotid MRA with 0.1 mmol/kg of gadobenate dimeglumine were reviewed. Axial carotid 3D T1-weighted fast low-angle shot sequence before and 3 min after contrast injection were acquired and subtracted (enhanced minus unenhanced). Vessel wall enhancement was assigned a four-point score using native or subtracted images from 0 (no enhancement) to 3 (strong enhancement). Stenosis degree was graded according to NASCET. RESULTS With native images, vessel wall enhancement was detected in 20/81 patients (25%) and in 20/161 carotids (12%), and scored 2.0+/-0.6 (mean+/-standard deviation); with subtracted images, in 21/81 (26%) and 22/161 (14%), and scored 2.5+/-0.6, respectively (P<0.001, Sign test). The overall stenosis degree distribution was: mild, 41/161 (25%); moderate, 77/161 (48%); severe, 43/161 (27%). Carotids with moderate stenosis showed vessel wall enhancement with a frequency (17/77, 22%) significantly higher than that observed in carotids with mild stenosis (1/41, 2%) (P=0.005, Fisher exact test) and higher, even though with borderline significance (P=0.078, Fisher exact test), than that observed in carotids with severe stenosis (4/43, 9%). CONCLUSION Roughly a quarter of patients undergoing carotid MRA showed vessel wall enhancement. Image subtraction improved vessel wall enhancement conspicuity. Vessel wall enhancement seems to be an event relatively independent from the degree of stenosis. Further studies are warranted to define the relation between vessel wall enhancement and histopathology, inflammatory status, and instability.


Journal of Computer Assisted Tomography | 2010

In vivo assessment of coronary stents with 64-row multidetector computed tomography: analysis of metal artifacts.

Giacomo Davide Edoardo Papini; Filippo Casolo; Giovanni Di Leo; Silvia Briganti; Cecilia Fantoni; Massimo Medda; Luigi Inglese; Luigi De Ambroggi; Francesco Sardanelli

Objective: To evaluate stent-induced artifacts by 64-row multidetector computed tomography (MDCT). Methods: We studied 26 stented patients with MDCT before conventional coronary angiography (CCA). The CT values were measured. Stents were classified as occluded, with significant stenosis, with nonsignificant stenosis, or patent. For the patent stents, mean in-stent and out-stent CT values were compared; stents 3 mm or smaller were compared with stents larger than 3 mm. Multidetector CT was compared with CCA. Results: We analyzed 42 stents. At CCA, 34 stents were patent, 5 were nonsignificantly stenosed, 1 was significantly stenosed, and 2 were occluded. At MDCT, 33 of 34 patent stents, 2 occluded stents, and 1 stent with significant stenosis were correctly diagnosed; nonsignificant stenoses were undetected, 1 patent stent was misdiagnosed as occluded (&kgr; = 0.727). The out-stent CT value was lower than in-stent CT value both in stents 3 mm or smaller (P = 0.001) and stents larger than 3 mm (P < 0.001). The in-stent CT value of stents 3 mm or smaller was higher (P = 0.011) than that of stents larger than 3 mm. Conclusions: Metal artifacts cause overlooking of nonsignificant stenosis.


PLOS ONE | 2018

Does Tetralogy of Fallot affect brain aging? A proof-of-concept study

Marina Codari; Giacomo Davide Edoardo Papini; Luca Melazzini; Francesca Romana Pluchinotta; Francesco Secchi; Mario Carminati; Alessandro Frigiola; Massimo Chessa; Francesco Sardanelli

The impact of congenital heart disease on brain aging has not been extensively investigated. We evaluated cerebral microbleeds and white matter hyperintensities on brain magnetic resonance imaging in adult patients with tetralogy of Fallot (ToF). Ten ToF patients (6 women, 4 men; aged 21–58 years; New York Heart Association [NYHA] class 1–2) were prospectively enrolled and underwent a T1-weighted, a T2-weighted dark fluid, and a T2*-weighted scans. Ten age- and sex-matched controls were prospectively recruited and subjected to the same acquisition protocol. Cerebral microbleeds (CMBs) were manually counted while white matter hyperintensities (WMHs) were segmented using ITK-Snap. Wilcoxon signed-rank test, Spearman correlation, and Bland-Altman statistics were used. The median (interquartile range [IQR]) age was 45.0 (30.5–49.5) years in ToF patients and 46.0 (30.5–49.8) years in controls. The median (IQR) of the number of CMBs was 6.0 (4.0–7.8) in ToF patients and 0 (0.0–0.0) in controls (p = 0.002). The WMHs burden was 2,506 (1,557–2,900) mm3 for ToF patients and 2,212 (1,860–2,586) mm3 for controls (p = 0.160). Moreover, a positive significant correlation was found between the WMHs burden and the NYHA class (ρ = 0.80, p = 0.005). Inter-operator concordance rate for the presence/absence of CMBs was 90%; the reproducibility for the WMHs burden was 77%. In conclusion, we found more cerebral microbleeds and a higher WMHs burden in adult ToF patients than in controls. This preliminary comparison supports the hypothesis of an early brain aging in ToF patients. Larger studies are warranted.


European Spine Journal | 2018

A critical appraisal of the quality of low back pain practice guidelines using the AGREE II tool and comparison with previous evaluations: a EuroAIM initiative

Fabio Martino Doniselli; Moreno Zanardo; Luigi Manfrè; Giacomo Davide Edoardo Papini; Alex Rovira; Francesco Sardanelli; Luca Maria Sconfienza; Estanislao Arana

PurposeTo assess the methodologic quality of guidelines for the management of low back pain (LBP) and compare their recommendations.MethodsNo ethics committee approval was needed for this systematic review. In March 2017, a systematic search was performed using MEDLINE, EMBASE, National Guideline Clearinghouse, and National Institute for Health and Clinical Excellence to find practice guidelines of assessment and management of LBP. The evaluation of guidelines quality was performed independently by four authors using the AGREE II tool, and the results were compared with previous appraisals performed in 2004 and 2009.ResultsOf 114 retrieved guidelines, eight were appraised. All except one reached the level of “acceptable” in overall result, with two of them reaching the highest scores. Only two guidelines reached a level of “acceptable” in every domain; the others had at least one domain with low scores. The guidelines had the higher scores (range = 63–94%) on “Scope and purpose” and “Clarity of presentation” (47–89%). “Stakeholder Involvement” has the highest variability between the guidelines results (40–96%). “Rigor of Development” reached an intermediate mean result (34–90%), “Applicability” (42–70%), and “Editorial Independence” (38–85%). Only three guidelines had a radiologist among authors and reached higher scores compared to guidelines without a radiologist among the authors. Compared to previous assessments, low-level guidelines were 53% in 2004, 36% in 2009, and 13% in 2017.ConclusionsConsidering all guidelines, only one had a “low” overall score, while half of them were rated as of “high” quality. Future guidelines might take this into account to improve clinical applicability.Graphical abstract


European Radiology | 2018

An eight-year prospective controlled study about the safety and diagnostic value of cardiac and non-cardiac 1.5-T MRI in patients with a conventional pacemaker or a conventional implantable cardioverter defibrillator

Pierpaolo Lupo; Riccardo Cappato; Giovanni Di Leo; Francesco Secchi; Giacomo Davide Edoardo Papini; Sara Foresti; Hussam Ali; Guido De Ambroggi; Antonio Sorgente; Gianluca Epicoco; Paola Maria Cannaò; Francesco Sardanelli

ObjectivesTo investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD).MethodsWe prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted <6 weeks before enrolment or prior to 01/01/2000, with cPM/cICD-carriers undergoing chest x-ray, CT or follow-up (reference group, RG).Results142 MRI (55 cardiac) were performed in 120 patients with cPM (n=71) or cICD (n=71). In the RG 98 measurements were performed in 95 patients with cPM (n=40) or cICD (n=58). No adverse events were observed. No MRI prolonged/interrupted. All cPM/cICD were correctly reprogrammed after MRI without malfunctions. One temporary communication failure was observed in one cPM-carrier. Immediately after MRI, 12/14 device interrogation parameters did not change significantly (clinically negligible changes of battery voltage and cICD charging time), without significant variations for SG versus RG. Three–12 months after MRI, 9/11 device interrogation parameters did not change significantly (clinically negligible changes of battery impedance/voltage). Non-significant changes of three markers of myocardial necrosis. Non-cardiac MRI: 82/87 diagnostic without artefacts; 4/87 diagnostic with artefacts; 1/87 partially diagnostic. Cardiac MRI: in cPM-carriers, 14/15 diagnostic with artefacts, 1/15 partially diagnostic; in cICD-carriers, 9/40 diagnostic with artefacts, 22 partially diagnostic, nine non-diagnostic.ConclusionsA favourable risk-benefit ratio of 1.5-T MRI in cPM/cICD carriers was reported.Key points• Cooperation between radiologists and cardiac electrophysiologists allowed safe 1.5-T MRI in cPM/cICD-carriers.• No adverse events for 142 MRI in 71 cPM-carriers and 71 cICD-carriers.• Ninety-nine per cent (86/87) of non-cardiac MRI in cPM/cICD-carriers were diagnostic.• All cPM-carrier cardiac MRIs had artefacts, 14 examinations diagnostic, 1 partially diagnostic.• Twenty-three per cent (9/40) of cardiac MRI in cICD-carriers were non-diagnostic.


Journal of Computer Assisted Tomography | 2017

Is Carotid Plaque Contrast Enhancement on MRI Predictive for Cerebral or Cardiovascular Events? A Prospective Cohort Study

Giacomo Davide Edoardo Papini; Giovanni Di Leo; Michele Bandirali; Biagio Cotticelli; Nicola Flor; Pietro Restivo; Giovanni Nano; Francesco Sardanelli

Objective The aim of this study was to correlate carotid plaque contrast enhancement (CPCE) to onset of cerebral/cardiovascular events (CCVE) in patients with atherosclerotic carotid disease. Methods The ethics committee approved this prospective study. Patients with carotid artery stenosis underwent magnetic resonance angiography before/after injection of 0.1 mmol/kg of gadobenate dimeglumine. Carotid plaque contrast enhancement was graded as follows: 0, no CPCE; 1, 1 single enhancement focus; 2, 2 or more foci. Results Seventy-seven patients (71 ± 9 years) had a stenosis degree: 34 mild, 16 moderate, 27 severe at the right side, and 36, 15, and 25 at the left side. Carotid plaque contrast enhancement was 0 in 30 patients, 1 in 26, 2 in 11 at the right, and 37, 19, and 13 at the left. Forty-seven CCVE occurred after magnetic resonance imaging, correlated to both stenosis degree (P = 0.006) and CPCE (P = 0.032). Excluding surgery/stenting, the correlation held only for CPCE (P = 0.017). Of 49 patients showing CPCE, 5 (10%) reported CCVE; of 21 patients without CPCE, none reported CCVE (P = 0.129). Conclusions The absence of CPCE seems to be a negative predictor for CCVE.


European Radiology | 2015

Prevalence and type of errors in dual-energy x-ray absorptiometry

Carmelo Messina; Michele Bandirali; Luca Maria Sconfienza; Nathascja Katia D’Alonzo; Giovanni Di Leo; Giacomo Davide Edoardo Papini; Fabio Massimo Ulivieri; Francesco Sardanelli

Collaboration


Dive into the Giacomo Davide Edoardo Papini's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Fabio Massimo Ulivieri

Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge