Giammario Calia
University of Sassari
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Giammario Calia.
Analytical Chemistry | 2009
Gianfranco Bazzu; Giulia G. M. Puggioni; Sonia Dedola; Giammario Calia; Gaia Rocchitta; Rossana Migheli; Maria Speranza Desole; John P. Lowry; Robert D. O'Neill; Pier Andrea Serra
A miniaturized biotelemetric device for the amperometric detection of brain tissue oxygen is presented. The new system, derived from a previous design, has been coupled with a carbon microsensor for the real-time detection of dissolved O(2) in the striatum of freely moving rats. The implantable device consists of a single-supply sensor driver, a current-to-voltage converter, a microcontroller, and a miniaturized data transmitter. The oxygen current is converted to a digital value by means of an analog-to-digital converter integrated in a peripheral interface controller (PIC). The digital data is sent to a personal computer using a six-byte packet protocol by means of a miniaturized 434 MHz amplitude modulation (AM) transmitter. The receiver unit is connected to a personal computer (PC) via a universal serial bus. Custom developed software allows the PC to store and plot received data. The electronics were calibrated and tested in vitro under different experimental conditions and exhibited high stability, low power consumption, and good linear response in the nanoampere current range. The in vivo results confirmed previously published observations on oxygen dynamics in the striatum of freely moving rats. The system serves as a rapid and reliable model for studying the effects of different drugs on brain oxygen and brain blood flow and it is suited to work with direct-reduction sensors or O(2)-consuming biosensors.
Analytical Chemistry | 2013
Gaia Rocchitta; Ottavio Secchi; Maria Domenica Alvau; Donatella Farina; Gianfranco Bazzu; Giammario Calia; Rossana Migheli; Maria Speranza Desole; Pier Andrea Serra
A new telemetry system for simultaneous detection of extracellular brain glucose and lactate and motion is presented. The device consists of dual-channel, single-supply miniature potentiostat-I/V converter, a microcontroller unit, a signal transmitter, and a miniaturized microvibration sensor. Although based on simple and inexpensive components, the biotelemetry device has been used for accurate transduction of the anodic oxidation currents generated on the surface of implanted glucose and lactate biosensors and animal microvibrations. The device was characterized and validated in vitro before in vivo experiments. The biosensors were implanted in the striatum of freely moving animals and the biotelemetric device was fixed to the animals head. Physiological and pharmacological stimulations were given in order to induce striatal neural activation and to modify the motor behavior in awake, untethered animals.
Sensors | 2009
Giammario Calia; Gaia Rocchitta; Rossana Migheli; Giulia Maria Grazia Puggioni; Ylenia Spissu; Gianfranco Bazzu; Vittorio Mazzarello; John P. Lowry; Maria Speranza Desole; Pier Andrea Serra
In this study we present the real-time monitoring of three key brain neurochemical species in conscious rats using implantable amperometric electrodes interfaced to a biotelemetric device. The new system, derived from a previous design, was coupled with carbon-based microsensors and a platinum-based biosensor for the detection of ascorbic acid (AA), O2 and glucose in the striatum of untethered, freely-moving rats. The miniaturized device consisted of a single-supply sensor driver, a current-to-voltage converter, a microcontroller and a miniaturized data transmitter. The redox currents were digitized to digital values by means of an analog-to-digital converter integrated in a peripheral interface controller (PIC), and sent to a personal computer by means of a miniaturized AM transmitter. The electronics were calibrated and tested in vitro under different experimental conditions and exhibited high stability, low power consumption and good linear response in the nanoampere current range. The in-vivo results confirmed previously published observations on striatal AA, oxygen and glucose dynamics recorded in tethered rats. This approach, based on simple and inexpensive components, could be used as a rapid and reliable model for studying the effects of different drugs on brain neurochemical systems.
Analytical Chemistry | 2010
Antonio Barberis; Gianfranco Bazzu; Giammario Calia; Giulia Maria Grazia Puggioni; Gaia Rocchitta; Rossana Migheli; Mario Schirra; Maria Speranza Desole; Pier Andrea Serra
Ascorbic acid (AA), one of the principal micronutrients in horticultural crops, plays a key role in the human metabolism, and its determination in food products has a great significance. Citrus fruits are rich in AA, but its content is highly susceptible to change during postharvest processing and storage. We present a new ultralow-cost system, constituted of an amperometric microsensor composed of three rod carbon electrodes connected to a telemetric device, for online detection of AA in orange juice, as an alternative to conventional analytical methods. The in vitro calibration, ranged from 0 to 5 mM, and AA juice content was calculated by adding low volumes of sample into an acetate buffer solution at a constant potential of +120 mV vs carbon pseudoreference. This new approach, which is simple, expandable, and inexpensive, seems appropriate for large scale commercial use.
Cns & Neurological Disorders-drug Targets | 2010
Gianfranco Bazzu; Giammario Calia; Giulia Maria Grazia Puggioni; Ylenia Spissu; Gaia Rocchitta; Patrizia Debetto; Jessica Grigoletto; Morena Zusso; Rossana Migheli; Pier Andrea Serra; Maria Speranza Desole; Egidio Miele
The classical animal models of Parkinsons disease (PD) rely on the use of neurotoxins, including 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP), 6-hydroxydopamine and, more recently, the agricultural chemicals paraquat and rotenone, to deplete dopamine (DA). These neurotoxins elicit motor deficits in different animal species although MPTP fails to induce a significant dopaminergic neurodegeneration in rats. In the attempt to better reproduce the key features of PD, in particular the progressive nature of neurodegeneration, alternative PD models have been developed, based on the genetic and neuropathological links between -synuclein ( -syn) and PD. In vivo microdialysis was used to investigate extracellular striatal DA dynamics in MPTP- and -syn-generated rodent models of PD. Acute and sub-acute MPTP intoxication of mice both induce prolonged release of striatal DA. Such DA release may be considered the first step in MPTP-induced striatal DA depletion and nigral neuron death, mainly through reactive oxygen species generation. Although MPTP induces DA reduction, neurochemical and motor recovery starts immediately after the end of treatment, suggesting that compensatory mechanisms are activated. Thus, the MPTP mouse model of PD may be unsuitable for closely reproducing the features of the human disease and predicting potential long-term therapeutic effects, in terms of both striatal extracellular DA and behavioral outcome. In contrast, the -syn-generated rat model of PD does not suffer from a massive release of striatal DA during induction of the nigral lesion, but rather is characterized by a prolonged reduction in baseline DA and nicotine-induced increases in dialysate DA levels. These results are suggestive of a stable nigrostriatal lesion with a lack of dopaminergic neurochemical recovery. The -syn rat model thus reproduces the initial stage and slow development of PD, with a time-dependent impairment in motor function. This article will describe the above experimental PD models and demonstrate the utility of microdialysis for their characterization.
Analytical Chemistry | 2012
Gaia Rocchitta; Ottavio Secchi; Maria Domenica Alvau; Rossana Migheli; Giammario Calia; Gianfranco Bazzu; Donatella Farina; Maria Speranza Desole; Pier Andrea Serra
Ethanol is one of the most widespread psychotropic agents in western society. While its psychoactive effects are mainly associated with GABAergic and glutamatergic systems, the positive reinforcing properties of ethanol are related to activation of mesolimbic dopaminergic pathways resulting in a release of dopamine in the nucleus accumbens. Given these neurobiological implications, the detection of ethanol in brain extracellular fluid (ECF) is of great importance. In this study, we describe the development and characterization of an implantable biosensor for the amperometric detection of brain ethanol in real time. Ten different designs were characterized in vitro in terms of Michaelis-Menten kinetics (V(MAX) and K(M)), sensitivity (linear region slope, limit of detection (LOD), and limit of quantification (LOQ)), and electroactive interference blocking. The same parameters were monitored in selected designs up to 28 days after fabrication in order to quantify their stability. Finally, the best performing biosensor design was selected for implantation in the nucleus accumbens and coupled with a previously developed telemetric device for the real-time monitoring of ethanol in freely moving, untethered rats. Ethanol was then administered systemically to animals, either alone or in combination with ranitidine (an alcohol dehydrogenase inhibitor) while the biosensor signal was continuously recorded. The implanted biosensor, integrated in the low-cost telemetry system, was demonstrated to be a reliable device for the short-time monitoring of exogenous ethanol in brain ECF and represents a new generation of analytical tools for studying ethanol toxicokinetics and the effect of drugs on brain ethanol levels.
Brain Research | 2013
Gianfranco Bazzu; Gaia Rocchitta; Rossana Migheli; Maria Domenica Alvau; Manuel Zinellu; Giulia Maria Grazia Puggioni; Giammario Calia; Giulia Mercanti; Pietro Giusti; Maria Speranza Desole; Pier Andrea Serra
The neurotoxin MPTP is known to induce dopamine release and depletion of ATP in the striatum of rats. Therefore, we studied the changes induced by MPTP and pargyline protection both on striatal dopamine release and on extracellular energy metabolites in freely moving rats, using dual asymmetric-flow microdialysis. A dual microdialysis probe was inserted in the right striatum of rats. MPTP (25mg/kg, 15mg/kg, 10mg/kg) was intraperitoneally administered for three consecutive days. MAO-B inhibitor pargyline (15mg/kg) was systemically administered before neurotoxin administration. The first MPTP dose induced an increase in dialysate dopamine and a decrease of DOPAC levels in striatal dialysate. After the first neurotoxin administration, increases in striatal glucose, lactate, pyruvate, lactate/pyruvate (L/P) and lactate/glucose (L/G) ratios were observed. Subsequent MPTP administrations showed a progressive reduction of dopamine, glucose and pyruvate levels with a concomitant further increase in lactate levels and L/P and L/G ratios. At day 1, pargyline pre-treatment attenuated the MPTP-induced changes in all studied analytes. Starting from day 2, pargyline prevented the depletion of dopamine, glucose and pyruvate while reduced the increase of lactate, L/P ratio and L/G ratio. These in vivo results suggest a pargyline neuroprotection role against the MPTP-induced energetic impairment consequent to mitochondrial damage. This neuroprotective effect was confirmed by TH immunostaining of the substantia nigra.
Talanta | 2011
Gianfranco Bazzu; Alice Biosa; Donatella Farina; Ylenia Spissu; Sonia Dedola; Giammario Calia; Giulia Maria Grazia Puggioni; Gaia Rocchitta; Rossana Migheli; Maria Speranza Desole; Pier Andrea Serra
Microdialysis is an extensively used technique for both in vivo and in vitro experiments, applicable to animal and human studies. In neurosciences, the in vivo microdialysis is usually performed to follow changes in the extracellular levels of substances and to monitor neurotransmitters release in the brain of freely moving animals. Catecholamines, such as dopamine and their related compounds, are involved in the neurochemistry and in the physiology of mental diseases and neurological disorders. It is generally supposed that the brains energy requirement is supplied by glucose oxidation. More recently, lactate was proposed to be the metabolic substrate used by neurons during synaptic activity. In our study, an innovative microdialysis approach for simultaneous monitoring of catecholamines, indolamines, glutamate and energy substrates in the striatum of freely moving rats, using an asymmetric perfusion flow rate on microdialysis probe, is described. As a result of this asymmetric perfusion, two samples are available from the same brain region, having the same analytes composition but different concentrations. The asymmetric flow perfusion could be a useful tool in neurosciences studies related to brains energy requirement, such as toxin-induced models of Parkinsons disease.
Talanta | 2017
Patrizia Monti; Giammario Calia; Salvatore Marceddu; Maria Antonietta Dettori; Davide Fabbri; Samir Jaoua; Robert D. O'Neill; Quirico Migheli; Giovanna Delogu; Pier Andrea Serra
First-generation amperometric biosensors are often based on the electro-oxidation of oxidase-generated H2O2. At the applied potential used in most studies, other molecules such as ascorbic acid or dopamine can be oxidized. Phenylenediamines are commonly used to avoid this problem: when these compounds are electro-deposited onto the transducer surface in the form of poly-phenylenediamine, a highly selective membrane is formed. Although there is no evidence of toxicity of the resulting polymer, phenylenediamine monomers are considered carcinogenic. An aim of this work was to evaluate the suitability of natural phenols as non-toxic alternatives to the ortho isomer of phenylenediamine. Electrosynthesis over Pt-Ir electrodes of 2-methoxy phenols (guaiacol, eugenol and isoeugenol), and hydroxylated biphenyls (dehydrodieugenol and magnolol) was achieved. The potentials used in the present study are significantly lower than values commonly applied during electro-polymerization. Polymers were obtained by means of constant potential amperometry, instead of cyclic voltammetry, in order to achieve multiple polymerizations, hence decreasing the time of realization and variability. Permselective properties of natural phenols were significantly improved at low polymerization potentials. Among the tested compounds, isoeugenol and magnolol, polymerized respectively at +25mV and +170mV against Ag/AgCl reference electrode, proved as permselective as poly-ortho-phenylenediamine and may be considered as effective polymeric alternatives. The natural phenol-coated electrodes were stable and responsive throughout 14 days. A biosensor prototype based on acetylcholine esterase and choline oxidase was electro-coated with poly-magnolol in order to evaluate the interference-rejecting properties of the electrosynthesized film in an amperometric biosensor; a moderate decrease in ascorbic acid rejection was observed during in vitro calibration of biosensors.
Archive | 2010
Pier Andrea Serra; Giulia Maria Grazia Puggioni; Gianfranco Bazzu; Giammario Calia; Rossana Migheli; Gaia Rocchitta
Neurochemical pathways involved in brain physiology or disease pathogenesis are mostly unknown either in physiological conditions or in neurodegenerative diseases. Nowadays the most frequent usage for biotelemetry is in medicine, in cardiac care units or step-down units in hospitals, even if virtually any physiological signal could be transmitted (FCC, 2000; Leuher, 1983; Zhou et al., 2002). In this chapter we present a wireless device connected with microsensors and biosensors capable to detect real-time variations in concentrations of important compounds present in central nervous system (CNS) and implicated in brain energetic metabolism (Bazzu et al., 2009; Calia et al., 2009).