Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Gill Louise Buchanan is active.

Publication


Featured researches published by Gill Louise Buchanan.


Journal of the American College of Cardiology | 2012

Transcatheter Aortic Valve Implantation With the Edwards SAPIEN Versus the Medtronic CoreValve Revalving System Devices A Multicenter Collaborative Study: The PRAGMATIC Plus Initiative (Pooled-RotterdAm-Milano-Toulouse In Collaboration)

Alaide Chieffo; Gill Louise Buchanan; Nicolas M. Van Mieghem; Didier Tchetche; Nicolas Dumonteil; Azeem Latib; Robert M.A. van der Boon; Olivier Vahdat; Bertrand Marcheix; Bruno Farah; Patrick W. Serruys; Jean Fajadet; Didier Carrié; Peter de Jaegere; Antonio Colombo

OBJECTIVES The aim of this study was to compare outcomes after transfemoral transcatheter aortic valve implantation with the Medtronic CoreValve (MCV) versus the Edwards SAPIEN/SAPIEN XT transcatheter heart valve (ESV) for severe aortic stenosis. BACKGROUND No large matched comparison study has been conducted so far evaluating both commercially available devices. METHODS The data from databases of 4 experienced European centers were pooled and analyzed. Due to differences in baseline clinical characteristics, propensity score matching was performed. Study objectives were Valve Academic Research Consortium outcomes at 30 days and 1 year. RESULTS In total, 793 patients were included: 453 (57.1%) treated with the MCV and 340 (42.9%) with the ESV. After propensity matching, 204 patients were identified in each group. At 30 days, there were no differences in all-cause mortality (MCV, 8.8% vs. ESV, 6.4%; hazard ratio [HR]: 1.422; 95% confidence interval [CI]: 0.677 to 2.984; p = 0.352), cardiovascular mortality (MCV, 6.9% vs. ESV, 6.4%; HR: 1.083; 95% CI: 0.496 to 2.364; p = 0.842), myocardial infarction (MCV, 0.5% vs. ESV, 1.5%; HR: 0.330; 95% CI: 0.034 to 3.200; p = 0.339), stroke (MCV, 2.9% vs. ESV, 1.0%; HR: 3.061; 95% CI: 0.610 to 15.346; p = 0.174), or device success (MCV, 95.6% vs. ESV, 96.6%; HR: 0.770; 95% CI: 0.281 to 2.108; p = 0.611). Additionally, there were no differences in major vascular complications (MCV, 9.3% vs. ESV, 12.3%; HR: 0.735; 95% CI: 0.391 to 1.382; p = 0.340) or life-threatening bleeding (MCV, 13.7% vs. ESV, 8.8%; HR: 1.644; 95% CI: 0.878 to 3.077; p = 0.120). MCV was associated with more permanent pacemakers (22.5% vs. 5.9%; HR: 4.634; 95% CI: 2.373 to 9.050; p < 0.001). At 1 year, there were no differences in all-cause (MCV, 16.2% vs. ESV, 12.3%; HR: 1.374; 95% CI: 0.785 to 2.407; p = 0.266) or cardiovascular (MCV, 8.3% vs. ESV, 7.4%; HR: 1.145; 95% CI: 0.556 to 12.361; p = 0.713) mortality. CONCLUSIONS No differences between the 2 commercially available transfemoral transcatheter aortic valve implantation devices were observed at the adjusted analysis in Valve Academic Research Consortium outcomes except for the need for permanent pacemakers with the MCV.


American Journal of Cardiology | 2012

Incidence, Predictors, and Implications of Access Site Complications With Transfemoral Transcatheter Aortic Valve Implantation

Nicolas M. Van Mieghem; Didier Tchetche; Alaide Chieffo; Nicolas Dumonteil; David Messika-Zeitoun; Robert M.A. van der Boon; Olivier Vahdat; Gill Louise Buchanan; Bertrand Marcheix; Dominique Himbert; Patrick W. Serruys; Jean Fajadet; Antonio Colombo; Didier Carrié; Alec Vahanian; Peter de Jaegere

Our study objective was to assess the incidence, predictors, and implications of access site complications related to transfemoral transcatheter aortic valve implantation (TAVI). We pooled the prospective TAVI databases of 5 experienced centers in Europe enrolling only transfemoral cases for this analysis. Access site complications were defined according to the Valve Academic Research Consortium end-point definitions. The global transfemoral TAVI database contained 986 patients. Percutaneous access and closure was performed in 803 patients (81%) and a surgical strategy in 183 (19%). Incidences of major vascular complications, life-threatening/disabling bleeding, and major bleeding were 14.2%, 11%, and 17.8% respectively. In the patient cohort with a completely percutaneous access strategy, major vascular complications and life-threatening/disabling bleedings were related to closure device failure in 64% and 29%, respectively. Female gender (odds ratio 1.63, 95% confidence interval 1.12 to 2.36) and use of >19Fr system (2.87, 1.68 to 4.91) were independent predictors for major vascular complications. Female gender (odds ratio 2.04, 95% confidence interval 1.31 to 3.17), use of >19Fr system (1.86, 1.02 to 3.38), peripheral arterial disease (2.14, 1.27 to 3.61), learning effect (0.45, 0.27 to 0.73), and percutaneous access strategy (2.39, 1.16 to 4.89) were independently associated with life-threatening/disabling bleedings. In conclusion, transfemoral TAVI is associated with a >10% incidence of major vascular-related complications. A considerable number of these events is related to arteriotomy closure failure. Arterial sheath size and female gender are important determinants of major vascular complications and life-threatening/disabling bleeding.


American Heart Journal | 2012

Adverse impact of bleeding and transfusion on the outcome post-transcatheter aortic valve implantation: Insights from the Pooled-RotterdAm-Milano-Toulouse In Collaboration Plus (PRAGMATIC Plus) initiative

Didier Tchetche; Robert M.A. van der Boon; Nicolas Dumonteil; Alaide Chieffo; Nicolas M. Van Mieghem; Bruno Farah; Gill Louise Buchanan; Redouane Saady; Bertrand Marcheix; Patrick W. Serruys; Antonio Colombo; Didier Carrié; Peter de Jaegere; Jean Fajadet

BACKGROUND Little is known about the impact of bleeding and red blood cells transfusion (RBC) on the outcome post transcatheter aortic valve implantation (TAVI). METHODS Between November 2005 and August 2011, 943 consecutive patients underwent TAVI. Bleeding was assessed according to the Valve Academic Research Consortium definitions. Patients receiving RBC were compared to those not requiring transfusion. RESULTS Life-threatening and major bleedings occurred respectively in 13.9% and 20.9% of the patients, significantly more frequently in the RBC cohort. Vascular complications occurred in 23.2% of the patients. Major and minor vascular complications were more frequent in the RBC group: 19.3 vs 5.2%, P < .001; 15.3 vs 9%, P = .003, respectively. Thirty-day all-cause mortality was 7.2%. Of the overall cohort, 38.9% required RBC transfusion; those receiving at least 4 U of RBC had higher 30-day all-cause mortality than those receiving 1 to 4 U of RBC and those not requiring transfusion: 14.4%, vs 6.3% vs 6.3%, respectively, P = .008. By multivariate analysis, transfusion of RBC was associated with an increased 30-day and 1-year mortality. Major stroke and all stages of acute kidney injury were significantly more frequent in the RBC cohort. CONCLUSIONS Bleeding is frequent after TAVI, mainly driven by vascular complications. RBC transfusion was associated with increased mortality at 1 year and increased risk of major stroke and acute kidney injury. Specific scores are needed to identify the patients at higher risk for TAVI-related bleeding and RBC transfusion.


Eurointervention | 2011

The role of sex on VARC outcomes following transcatheter aortic valve implantation with both Edwards SAPIEN™ and Medtronic CoreValve ReValving System® devices: the Milan registry

Gill Louise Buchanan; Alaide Chieffo; Matteo Montorfano; Francesco Maisano; Azeem Latib; Cosmo Godino; Micaela Cioni; Maria Angela Gullace; Annalisa Franco; Chiara Gerli; Ottavio Alfieri; Antonio Colombo

AIMS To assess outcomes after transcatheter aortic valve implantation (TAVI) according to sex, with the two available valves and four recognised delivery approaches. METHODS AND RESULTS VARC outcomes are reported according to sex for 305 high-risk patients consecutively treated in our centre, via available access routes utilising the Edwards SAPIEN™/SAPIEN™ XT or the Medtronic CoreValve ReValving System® devices. Three hundred and five patients underwent TAVI: 52.1% male and 47.9% female. Females had a smaller body surface area (1.84±0.16 m² vs. 1.70±0.16 m²; p<0.001) and aortic annulus (24.4±1.6 mm vs. 22.6±1.7 mm; p<0.001) with increased symptoms (NYHA Class III/IV 61.6% vs. 73.6%; p=0.026). Conversely, men had more comorbidities: diabetes mellitus (35.2% vs. 21.9%; p=0.010), chronic kidney disease (41.8% vs. 23.3%; p=0.001), chronic obstructive pulmonary disease (45.3% vs. 30.1%; p=0.006) and previous myocardial infarction (28.3% vs. 14.4%; p=0.003). Thirty-day mortality was 4.7% with no difference between groups. There was a trend for females to develop more major vascular complications (11.9% vs. 19.9%; p=0.058). Notably, females required more blood transfusion (38.4% vs. 50.0%; p=0.041). No differences were observed in device success (92.5%; p=0.667), combined safety endpoint (61.8%; p=0.211) or combined efficacy endpoint (72.0%; p=0.889). CONCLUSIONS Female sex was a predictor of major vascular complications with females requiring more transfusion. No differences were noted amongst patients undergoing TAVI in composite safety and efficacy endpoints according to sex.


American Heart Journal | 2013

Trends in outcome after transfemoral transcatheter aortic valve implantation

Nicolas M. Van Mieghem; Alaide Chieffo; Nicolas Dumonteil; Didier Tchetche; Robert M.A. van der Boon; Gill Louise Buchanan; Bertrand Marcheix; Olivier Vahdat; Patrick W. Serruys; Jean Fajadet; Didier Carrié; Antonio Colombo; Peter de Jaegere

BACKGROUND Transfemoral transcatheter aortic valve implantation (TF-TAVI) is a viable and safe treatment strategy for patients with symptomatic severe aortic stenosis and high operative risk and has been introduced as such in the recently updated European guidelines on the management of valvular heart disease.Our aim was to assess trends in outcome after TF-TAVI. METHODS Propensity score-matched analysis of a multicenter registry of consecutive patients undergoing TF-TAVI subdivided into 3 tertiles based on enrollment date was performed. Three tertiles of 214 propensity score-matched patients were compared. RESULTS With mounting experience and moving from the initial to the last cohort, procedural contrast volume and radiation time decreased. Over time, there were less major vascular complications (15% vs 7.9%, P = .023), life-threatening bleedings (17.8% vs 7.9%, P = .003), and major bleedings (22.4% vs 12.1%, P = .007). Major vascular complications and life-threatening bleedings caused by closure device failure decreased significantly (9.2% vs 3.1% [P = .01] and 5.7% vs 1 % [P = .01], respectively). The combined safety end point dropped from 31.3% in tertile (T) (T1) to 17.8% in T3 (P < .001). By multivariable analysis, the last cohort as compared with the initial cohort was associated with significant reductions in 30-day mortality (odds ratio [OR] 0.35, 95% CI 0.12-0.96), stage 3 AKI (OR 0.12, 95% CI 0.29-0.93), and the combined safety end point (OR 0.52, 95% CI 0.29-0.93). One-year survival improved significantly (T1 79% vs T3 86%, P = .016). CONCLUSIONS Over time, TAVI is performed with significant reductions in major vascular complications, life-threatening bleedings, and the combined clinical safety end point and improved 1-year survival.


American Heart Journal | 2013

Impact of preoperative chronic kidney disease on short- and long-term outcomes after transcatheter aortic valve implantation: A Pooled-RotterdAm-Milano-Toulouse In Collaboration Plus (PRAGMATIC-Plus) initiative substudy

Nicolas Dumonteil; Robert M.A. van der Boon; Didier Tchetche; Alaide Chieffo; Nicolas M. Van Mieghem; Bertrand Marcheix; Gill Louise Buchanan; Olivier Vahdat; Patrick W. Serruys; Jean Fajadet; Antonio Colombo; Peter de Jaegere; Didier Carrié

BACKGROUND Only limited and conflicting data on the impact of preoperative chronic kidney disease (CKD) on outcomes after transcatheter aortic valve implantation (TAVI) are available. METHODS We retrospectively analyzed pooled data from the prospective TAVI databases of 4 centers (942 patients). Valve Academic Research Consortium end point definitions were used. The outcomes were compared among patients with normal estimated glomerular filtration rate (≥90 mL/min), mild (60-89 mL/min), moderate (30-59 mL/min), and severe (<30 mL/min) CKD and those on chronic hemodialysis (HD). The primary end point was 1-year survival. RESULTS A total of 109 patients had a normal estimated glomerular filtration rate (11.6%); 329 (34.9%) had mild, 399 (42.5%) moderate, 72 (7.5%) severe CKD, and 33 (3.5%) were on HD. Baseline and procedural characteristics were similar among all groups except for Logistic EuroSCORE. Major stroke, life-threatening bleeding, all-cause 30-day mortality (HD 15.2%, severe CKD 8.3%, moderate CKD 8.3%, mild CKD 6.7%, normal 1.8%, P = .007) and 1-year survival (HD 54.8%, severe CKD 67.2%, moderate CKD 80.0%, mild CKD 85.2%, normal eGFR 91.4%, HD vs severe CKD P = .23, severe CKD vs moderate CKD P = .002, moderate CKD vs mild CKD P = .04, moderate CKD vs normal eGFR P = .03, by log-rank test) differed significantly across groups. Through multivariable analysis, HD and severe CKD were independently associated with an increased risk of 1-year mortality (hazard ratios 5.07 [95% CI 1.79-14.35, P = .002] and 4.03 [95% CI 1.52-10.69, P = .005], respectively). CONCLUSIONS Patients with CKD who undergo TAVI have a higher-risk profile and worse 30-day and 1-year outcomes. Chronic hemodialysis and severe preprocedural CKD are independently associated with an increased risk of 1-year mortality after TAVI.


Thrombosis | 2012

Stent Thrombosis: Incidence, Predictors and New Technologies

Gill Louise Buchanan; Sandeep Basavarajaiah; Alaide Chieffo

Some concerns have been raised regarding the risk of late and very late stent thrombosis (ST) following drug-eluting stent implantation. Despite remaining an uncommon complication of percutaneous coronary intervention, when ST occurs, it can be catastrophic to the individual, commonly presenting as acute ST elevation myocardial infarction or sudden cardiac death. The incidence and predictors of ST have been reported in the literature and the role of dual antiplatelet therapies in the avoidance of such a complication remains vital. Ongoing studies are assessing the role of these therapies including platelet reactivity testing, genetic testing and optimum duration of therapy. In addition, newer polymer-free and bioabsorbable stents are under investigation in the quest to potentially minimise the risk of ST.


Catheterization and Cardiovascular Interventions | 2013

A ''Modified Crossover Technique'' for Vascular Access Management in High-Risk Patients Undergoing Transfemoral Transcatheter Aortic Valve Implantation

Gill Louise Buchanan; Alaide Chieffo; Matteo Montorfano; Davide Maccagni; Francesco Maisano; Azeem Latib; Remo Daniel Covello; Antonio Grimaldi; Ottavio Alfieri; Antonio Colombo

To describe results from our “modified crossover technique” for vascular access management during transcatheter aortic valve implantation (TAVI).


Eurointervention | 2013

Two-year outcomes following unprotected left main stenting with first vs. new-generation drug-eluting stents: the FINE registry.

Gill Louise Buchanan; Alaide Chieffo; Chiara Bernelli; Matteo Montorfano; Mauro Carlino; Azeem Latib; Filippo Figini; Francesco Giannini; Alessandro Durante; Alfonso Ielasi; Alfredo Castelli; Antonio Colombo

AIMS To assess two-year outcomes following first vs. new-generation drug-eluting stent (DES) implantation in unprotected left main (ULMCA) percutaneous coronary intervention. METHODS AND RESULTS All eligible patients from our two-centre registry treated with first and new-generation DES from October 2006 to November 2010 were analysed. The study objective was major adverse cardiac events (MACE), defined as all-cause mortality, target vessel revascularisation (TVR) and myocardial infarction (MI) at two years. In total, 186 patients were included: 93 (50.0%) treated with first vs. 93 (50.0%) with new-generation DES. No differences were observed in baseline clinical characteristics except for higher EuroSCORE with new-generation DES (3.6±2.5 vs. 4.6±2.7; p=0.007). No significant difference was observed in stenting techniques; two stents were used respectively in 53.8% vs. 44.1% (p=0.187). Notably, intravascular ultrasound guidance was more frequent with new-generation DES (46.2% vs. 61.3%; p=0.040). At 730.0 (interquartile range 365.5-1,224.5) days, there was a trend towards improved MACE with new-generation DES (31.2% vs. 19.6%; p=0.070) and a significant reduction in TVR (23.7% vs. 12.0%; p=0.038) and MI (4.3% vs. 0%; p=0.044). Notably, there were four cases of definite stent thrombosis (ST) with first vs. none with new-generation DES (p=0.044). CONCLUSIONS In our study, new-generation DES had a trend for less MACE and improved results with regard to MI, TVR and definite ST at two-year follow-up.


Eurointervention | 2012

ACS and STEMI treatment: gender-related issues.

Alaide Chieffo; Gill Louise Buchanan; Fina Mauri; Julinda Mehilli; Beatriz Vaquerizo; Anouska Moynagh; Roxana Mehran; Marie Claude Morice

Cardiovascular disease is the leading cause of death amongst women, with acute coronary syndromes (ACS) representing a significant proportion. It has been reported that in women presenting with ACS there is underdiagnosis and consequent undertreatment leading to an increase in hospital and long-term mortality. Several factors have to be taken into account, including lack of awareness both at patient and at physician level. Women are generally not aware of the cardiovascular risk and symptoms, often atypical, and therefore wait longer to seek medical attention. In addition, physicians often underestimate the risk of ACS in women leading to a further delay in accurate diagnosis and timely appropriate treatment, including cardiac catheterisation and primary percutaneous coronary intervention, with consequent delayed revascularisation times. It has been acknowledged by the European Society of Cardiology that gender disparities do exist, with a Class I, Level of Evidence B recommendation that both genders should be treated in the same way when presenting with ACS. However, there is still a lack of awareness and the mission of Women in Innovation, in association with Stent for Life, is to change the perception of women with ACS and to achieve prompt diagnosis and treatment.

Collaboration


Dive into the Gill Louise Buchanan's collaboration.

Top Co-Authors

Avatar

Alaide Chieffo

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar

Antonio Colombo

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar

Azeem Latib

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar

Matteo Montorfano

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar

Filippo Figini

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mauro Carlino

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar

Ottavio Alfieri

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar

Micaela Cioni

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar

Chiara Bernelli

Vita-Salute San Raffaele University

View shared research outputs
Researchain Logo
Decentralizing Knowledge