Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Giuseppe Luongo is active.

Publication


Featured researches published by Giuseppe Luongo.


Clinical Implant Dentistry and Related Research | 2014

In Vivo Regenerative Properties of Coralline‐Derived (Biocoral) Scaffold Grafts in Human Maxillary Defects: Demonstrative and Comparative Study with Beta‐Tricalcium Phosphate and Biphasic Calcium Phosphate by Synchrotron Radiation X‐Ray Microtomography

Alessandra Giuliani; Adrian Manescu; Emanuel Larsson; Giuliana Tromba; Giuseppe Luongo; Adriano Piattelli; Francesco Mangano; Giovanna Iezzi; Carlo Mangano

BACKGROUND In recent years, there has been interest on the fabrication of systems using particulates or block-based approach for bone tissue engineering (TE) scaffolds, possessing porous interconnected structures. In fact, these particular morphologies greatly increase the surface area for more chemical and biological reactions to take place. PURPOSE This study was designed to demonstrate the unique capability of the synchrotron radiation x-ray microtomography (micro-CT) in offering an advanced characterization of coralline-derived (Biocoral) biomaterials placed in human maxillary defects as it allows, in a nondestructive way, a complete, precise, and high-resolution three-dimensional analysis of their microstructural parameters. Moreover, the comparison between Biocoral and other biomaterials was explored to understand the mechanism of their biological behavior as bone substitute. MATERIALS AND METHODS Implant survival, bone regeneration, graft resorption, neovascularization, and morphometric parameters (including anisotropy and connectivity index of the structures) were evaluated by micro-CT in Biocoral and the other biomaterials after 6 to 7 months from implantation in human maxillary bone defects. RESULTS After the in vivo tests, a huge amount of bone was detected in the retrieved Biocoral-based samples, coupled with a good rate of biomaterial resorption and the formation of a homogeneous and rich net of new vessels. The morphometric parameters were comparable to those obtained in the biphasic calcium phosphate-based control, with the exception of the connectivity index for which this control exhibited the most well-connected structure. This last result, together with those referred to the poor performances of the β-tricalcium phosphate block-based sample, suggests that the particular scaffold morphology may play a role in the hunt the optimal scaffold structure to be implanted. CONCLUSION In this limited study, implant success rate seems not strictly dependent on the biomaterial that is used, but on the scaffold morphology. Micro-CT technique was demonstrated to play a fundamental role in advanced characterization of bone TE constructs.


Implant Dentistry | 2013

Immediate Restoration of Fixed Partial Prostheses Supported by One-Piece Narrow-Diameter Selective Laser Sintering Implants: A 2-Year Prospective Study in the Posterior Jaws of 16 Patients

Francesco Mangano; Samuele Pozzi-Taubert; Piero Antonio Zecca; Giuseppe Luongo; Rachel Sammons; Carlo Mangano

Purpose:Selective laser sintering (SLS) is a new technique that allows implants to be produced by annealing titanium powder microparticles in a focused laser beam, according to a computer-generated model. The aim of this study was to evaluate the survival and success rate of immediately restored 1-piece narrow-diameter SLS implants, placed in the posterior jaws, after 2 years of functional loading. Materials and Methods:At the 2-year follow-up examination, several parameters were assessed. Success criteria included absence of pain, suppuration, exudation, implant mobility; distance between the implant shoulder and the first visible bone-to-implant contact <2.0 mm; and absence of prosthetic complications. Results:Thirty-seven implants were placed in the posterior jaws (14 maxilla, 23 mandible) of 16 patients (9 males, 7 females). The prosthetic restorations comprised 16 immediately restored fixed partial prostheses. No implant failure occurred, resulting in a 100% survival rate. The implant success was 94.6%, and the mean distance between the implant shoulder and the first visible bone-to-implant contact (DIB) was 0.4 ± 0.3 mm. Conclusions:This study supports the hypothesis that 1-piece narrow-diameter SLS implants can be used in fixed prosthetic rehabilitations in the posterior regions of both jaws with a predictable positive outcome.


Journal of Oral Implantology | 2014

Maxillary ridge augmentation with custom-made CAD/CAM scaffolds. A 1-year prospective study on 10 patients.

Francesco Mangano; Aldo Macchi; Jamil Awad Shibli; Giuseppe Luongo; Giovanna Iezzi; Adriano Piattelli; Alberto Caprioglio; Carlo Mangano

Several procedures have been proposed to achieve maxillary ridge augmentation. These require bone replacement materials to be manually cut, shaped, and formed at the time of implantation, resulting in an expensive and time-consuming process. In the present study, we describe a technique for the design and fabrication of custom-made scaffolds for maxillary ridge augmentation, using three-dimensional computerized tomography (3D CT) and computer-aided design/computer-aided manufacturing (CAD/CAM). CT images of the atrophic maxillary ridge of 10 patients were acquired and modified into 3D reconstruction models. These models were transferred as stereolithographic files to a CAD program, where a virtual 3D reconstruction of the alveolar ridge was generated, producing anatomically shaped, custom-made scaffolds. CAM software generated a set of tool-paths for manufacture by a computer-numerical-control milling machine into the exact shape of the reconstruction, starting from porous hydroxyapatite blocks. The custom-made scaffolds were of satisfactory size, shape, and appearance; they matched the defect area, suited the surgeons requirements, and were easily implanted during surgery. This helped reduce the time for surgery and contributed to the good healing of the defects.


International Journal of Medical Robotics and Computer Assisted Surgery | 2013

Maxillary sinus augmentation using computer-aided design/computer-aided manufacturing (CAD/CAM) technology

F. Mangano; P. Zecca; S. Pozzi-Taubert; A. Macchi; M. Ricci; Giuseppe Luongo; C. Mangano

Maxillary sinus augmentation is a common method for increasing bone height for insertion of dental implants. In most cases, the graft is manually cut into a roughly appropriate shape by visual estimation during the operation; accordingly, the shape of the graft depends considerably on the experience of the surgeon. We have developed a computer‐aided design/computer‐aided manufacturing (CAD/CAM) technique to generate custom‐made block grafts for sinus augmentation, and a customized cutting guide to precisely position the lateral wall and facilitate membrane elevation, using cone‐beam computed tomography (CBCT).


BMC Oral Health | 2017

Intraoral scanners in dentistry: a review of the current literature

Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo

BackgroundIntraoral scanners (IOS) are devices for capturing direct optical impressions in dentistry. The purpose of this narrative review on the use of IOS was to: (1) identify the advantages/disadvantages of using optical impressions compared to conventional impressions; (2) investigate if optical impressions are as accurate as conventional impressions; (3) evaluate the differences between the IOS currently available commercially; (4) determine the current clinical applications/limitations in the use of IOS.MethodsElectronic database searches were performed using specific keywords and MeSH terms. The searches were confined to full-text articles written in English and published in peer-reviewed journals between January 2007 and June 2017.ResultsOne hundred thirty-two studies were included in the present review; among them, 20 were previous literature reviews, 78 were in vivo clinical studies (6 randomized controlled/crossover trials, 31 controlled/comparative studies; 24 cohort studies/case series; 17 case reports) and 34 were in vitro comparative studies.ConclusionsOptical impressions reduce patient discomfort; IOS are time-efficient and simplify clinical procedures for the dentist, eliminating plaster models and allowing better communication with the dental technician and with patients; however, with IOS, it can be difficult to detect deep margin lines in prepared teeth and/or in case of bleeding, there is a learning curve, and there are purchasing and managing costs. The current IOS are sufficiently accurate for capturing impressions for fabricating a whole series of prosthetic restorations (inlays/onlays, copings and frameworks, single crowns and fixed partial dentures) on both natural teeth and implants; in addition, they can be used for smile design, and to fabricate posts and cores, removable partial prostheses and obturators. The literature to date does not support the use of IOS in long-span restorations with natural teeth or implants. Finally, IOS can be integrated in implant dentistry for guided surgery and in orthodontics for fabricating aligners and custom-made devices.


International Journal of Periodontics & Restorative Dentistry | 2017

Immediate Loading of Single Implants: A 2-Year Prospective Multicenter Study.

Carlo Mangano; Filiep Raes; Carolina Lenzi; Tammaro Eccellente; Michele Ortolani; Giuseppe Luongo; Francesco Mangano

The aim of this prospective multicenter study was to evaluate the outcomes of single implants subjected to immediate functional loading. Inclusion criteria were single-tooth placement in postextraction sockets or fully healed sites, and sufficient bone height and width to place an implant of at least 3.5 × 10.0 mm. All implants were functionally loaded immediately after placement and followed for 2 years. Outcome measures were implant survival, complications, and peri-implant marginal bone loss (MBL). A total of 57 implants (38 maxilla, 19 mandible) were placed in 46 patients (23 men, 23 women, aged 18-73 years). Of these, 10 implants were placed in postextraction sockets. One implant failed, in a healed site, giving a patient-based overall 2-year survival rate of 97.6%. The incidence of biologic complications was 1.8%; prosthetic complications amounted to 7.5%. The peri-implant MBL was 0.37 ± 0.22 mm (healed sites: 0.4 mm ± 0.22; postextraction sockets: 0.3 mm ± 0.22). The immediate functional loading of single implants seems to represent a safe and successful procedure. Long-term follow-up studies on a larger sample of patients are needed to confirm these results.


BioMed Research International | 2016

Custom-Made Synthetic Scaffolds for Bone Reconstruction: A Retrospective, Multicenter Clinical Study on 15 Patients

Fabrizia Luongo; Francesco Mangano; Aldo Macchi; Giuseppe Luongo; Carlo Mangano

Purpose. To present a computer-assisted-design/computer-assisted-manufacturing (CAD/CAM) technique for the design, fabrication, and clinical application of custom-made synthetic scaffolds, for alveolar ridge augmentation. Methods. The CAD/CAM procedure consisted of (1) virtual planning/design of the custom-made scaffold; (2) milling of the scaffold into the exact size/shape from a preformed synthetic bone block; (3) reconstructive surgery. The main clinical/radiographic outcomes were vertical/horizontal bone gain, any biological complication, and implant survival. Results. Fifteen patients were selected who had been treated with a custom-made synthetic scaffold for ridge augmentation. The scaffolds closely matched the shape of the defects: this reduced the operation time and contributed to good healing. A few patients experienced biological complications, such as pain/swelling (2/15: 13.3%) and exposure of the scaffold (3/15: 20.0%); one of these had infection and complete graft loss. In all other patients, 8 months after reconstruction, a well-integrated newly formed bone was clinically available, and the radiographic evaluation revealed a mean vertical and horizontal bone gain of 2.1 ± 0.9 mm and 3.0 ± 1.0 mm, respectively. Fourteen implants were placed and restored with single crowns. The implant survival rate was 100%. Conclusions. Although positive outcomes have been found with custom-made synthetic scaffolds in alveolar ridge augmentation, further studies are needed to validate this technique.


BioMed Research International | 2017

Early Bone Formation around Immediately Loaded Transitional Implants Inserted in the Human Posterior Maxilla: The Effects of Fixture Design and Surface

Carlo Mangano; Jamil Awad Shibli; Jefferson Trabach Pires; Giuseppe Luongo; Adriano Piattelli; Giovanna Iezzi

Aim. To evaluate the effects of fixture design and surface on the early bone formation around immediately loaded implants inserted in the human posterior maxilla. Materials and Methods. Ten totally edentulous subjects received two transitional implants: one tapered implant with knife-edge threads/nanostructured calcium-incorporated surface (test: Anyridge®, Megagen, Gyeongbuk, South Korea) and one cylindrical implant with self-tapping threads/sandblasted surface (control: EZPlus®, Megagen). The implants were placed according to a split-mouth design and immediately loaded to support an interim complete denture; after 8 weeks, they were removed for histologic/histomorphometric analysis. The bone-to-implant contact (BIC%) and the bone density (BD%) were calculated. The Wilcoxon test was used to evaluate the differences. Results. With test implants, a mean BIC% and BD% of 35.9 (±9.1) and 31.8 (±7.5) were found. With control implants, a mean BIC% and BD% of 29.9 (±7.6) and 32.5 (±3.9) were found. The mean BIC% was higher with test implants, but this difference was not significant (p = 0.16). Similar BD% were found in the two groups (p = 0.9). Conclusions. In the posterior maxilla, under immediate loading conditions, implants with a knife-edge thread design/nanostructured calcium-incorporated surface seem to increase the peri-implant endosseous healing properties, when compared to implants with self-tapping thread design/sandblasted surface.


The Open Dentistry Journal | 2018

Conventional Vs Digital Impressions: Acceptability, Treatment Comfort and Stress Among Young Orthodontic Patients

Alessandro Mangano; Matteo Beretta; Giuseppe Luongo; Carlo Mangano; Francesco Mangano

Objective: The objective of the present study was to compare patients’ acceptability, comfort and stress with conventional and digital impressions. Materials and Methods: Thirty young orthodontic patients (15 males and 15 females) who had no previous experience of impressions were enrolled in this study. Conventional impressions for orthodontic study models of the dental arches were taken using an alginate impression material (Hydrogum®, Zhermack Spa, Badia Polesine, Rovigo, Italy). Fifteen days later, digital impressions of both arches were acquired using an intraoral scanner (CS3600®, Carestream Dental, Rochester, NY, USA). Immediately after impression taking, patients’ acceptability, comfort and stress were measured using two questionnaires and the State anxiety scale. Results: Data showed no difference in terms of anxiety and stress; however, patients preferred the use of digital impressions systems instead of conventional impression techniques. Alginate impressions resulted as fast as digital impressions. Conclusions: Digital impressions resulted the most accepted and comfortable impression technique in young orthodontic patients, when compared to conventional techniques.


Journal of dental research, dental clinics, dental prospects | 2018

Immediate functional loadingof single implants: a multicenter study with 4 years offollow-up

Filiep Raes; Tammaro Eccellente; Carolina Lenzi; Michele Ortolani; Giuseppe Luongo; Carlo Mangano; Francesco Mangano

Background. In the current scientific literature there are only few studies on the immediate functional loading of single implants. The aim of the present present study was to evaluate the 4-year survival rate, complication rate and peri-implant marginal bone loss (PIMBL) of immediately loaded single implants inserted in healed ridges and fresh post-extraction sites. Methods. Six centers were involved in this prospective study. The surgical and prosthetic protocol was defined in detail, before the start of recruiting patients. Recruitment of patients and performance of surgeries took place between February 2012 and February 2013. Criteria for inclusion were single-tooth gaps in healed ridges and fresh post-extraction sockets. All the fixtures (Anyridge®, Megagen Corporation, Gyeongbuk, South Korea) were functionally loaded immediately after insertion and followed for a period of 4 years. Outcome measures were implant survival, complications and PIMBL. Results. Forty-six patients (18‒73 years of age) were selected. In total, 57 fixtures were placed (10 in fresh post-extraction sockets). After 4 years of functional loading, only one fixture was lost; therefore, high survival rates (97.6% patient-based; 98.1% implant-based) were reported. In addition, a limited incidence of biologic (4.8% patient-based; 3.8% implant-based) and prosthetic (9.7% patient-based; 7.6% implant-based) complications was reported. The overall 4-year PIMBL amounted to 0.38±0.21 mm (healed ridges: 0.4±0.21 mm; fresh post-extraction sockets: 0.33±0.20 mm). Conclusion. Loading single implants immediately seems to be a highly successful treatment modality. However, long-term data are needed to confirm these positive outcomes.

Collaboration


Dive into the Giuseppe Luongo's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Adriano Piattelli

University of Chieti-Pescara

View shared research outputs
Top Co-Authors

Avatar

Giovanna Iezzi

University of Chieti-Pescara

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Aldo Macchi

University of Insubria

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Manuela Rapani

University of Chieti-Pescara

View shared research outputs
Researchain Logo
Decentralizing Knowledge