Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Gloria L. Hwang is active.

Publication


Featured researches published by Gloria L. Hwang.


Journal of Vascular and Interventional Radiology | 2009

Incorporating Cone-beam CT into the Treatment Planning for Yttrium-90 Radioembolization

John D. Louie; N. Kothary; William T. Kuo; Gloria L. Hwang; Lawrence V. Hofmann; Michael L. Goris; Andrei Iagaru; Daniel Y. Sze

PURPOSE To prepare for yttrium-90 ((90)Y) microsphere radioembolization therapy, digital subtraction angiography (DSA) and technetium- 99m-labeled macroaggregated albumin ((99m)Tc MAA) scintigraphy are used for treatment planning and detection of potential nontarget embolization. The present study was performed to determine if cone-beam computed tomography (CBCT) affects treatment planning as an adjunct to these conventional imaging modalities. MATERIALS AND METHODS From March 2007 to August 2008, 42 consecutive patients (21 men, 21 women; mean age, 59 years; range, 21-75 y) who underwent radioembolization were evaluated by CBCT in addition to DSA and (99m)Tc MAA scintigraphy during treatment planning, and their records were retrospectively reviewed. The contrast-enhanced territories shown by CBCT with selective intraarterial contrast agent administration were used to predict intrahepatic and possible extrahepatic distribution of microspheres. RESULTS In 22 of 42 cases (52%), extrahepatic enhancement or incomplete tumor perfusion seen on CBCT affected the treatment plan. In 14 patients (33%), the findings were evident exclusively on CBCT and not detected by DSA. When comparing CBCT versus (99m)Tc MAA scintigraphy, CBCT showed eight cases of extrahepatic enhancement (19%) that were not evident on (99m)Tc MAA imaging. CBCT findings directed the additional embolization of vessels or repositioning of the catheter for better contrast agent and microsphere distribution. One case of gastric ulcer from nontarget embolization caused by reader error was observed. CONCLUSIONS CBCT can provide additional information about tumor and tissue perfusion not currently detectable by DSA or (99m)Tc MAA imaging, which should optimize (90)Y microsphere delivery and reduce nontarget embolization.


Journal of Vascular and Interventional Radiology | 2010

Utility of C-arm CT in Patients with Hepatocellular Carcinoma undergoing Transhepatic Arterial Chemoembolization

A. Tognolini; John D. Louie; Gloria L. Hwang; Lawrence V. Hofmann; Daniel Y. Sze; N. Kothary

PURPOSE To evaluate the utility of C-arm computed tomography (CT) on treatment algorithms in patients undergoing transhepatic arterial chemoembolization for hepatocellular carcinoma (HCC). MATERIALS AND METHODS From March 2008 to July 2008, 84 consecutive patients with HCC underwent 100 consecutive transhepatic arterial chemoembolizations with iodized oil. Unenhanced and iodinated contrast medium-enhanced C-arm CT with planar and three-dimensional imaging were performed in addition to conventional digital subtraction angiography (DSA) in all patients. The effect on diagnosis and treatment was determined by testing the hypotheses that C-arm CT, in comparison to DSA, provides (a) improved lesion detection, (b) expedient identification and mapping of arterial supply to a tumor, (c) improved characterization of a lesion to allow confident differentiation of HCC from pseudolesions such as arterioportal shunts, and (d) an improved evaluation of treatment completeness. The effect of C-arm CT was analyzed on the basis of information provided with C-arm CT that was not provided or readily apparent at DSA. RESULTS C-arm CT was technically successful in 93 of the 100 procedures (93%). C-arm CT provided information not apparent or discernible at DSA in 30 of the 84 patients (36%) and resulted in a change in diagnosis, treatment planning, or treatment delivery in 24 (28%). The additional information included, amongst others, visualization of additional or angiographically occult tumors in 13 of the 84 patients (15%) and identification of incomplete treatment in six (7.1%). CONCLUSIONS C-arm CT is a useful collaborative tool in patients undergoing transhepatic arterial chemoembolization and can affect patient care in more than one-fourth of patients.


Journal of Vascular and Interventional Radiology | 2009

High-risk retrieval of adherent and chronically implanted IVC filters: techniques for removal and management of thrombotic complications.

William T. Kuo; Ricky T. Tong; Gloria L. Hwang; John D. Louie; Edward A. Lebowitz; Daniel Y. Sze; Lawrence V. Hofmann

PURPOSE To evaluate the safety and efficacy of aggressive techniques for retrieving adherent and chronically implanted inferior vena cava (IVC) filters. MATERIALS AND METHODS A single-center retrospective review was performed on all patients who underwent attempted filter retrieval from October 2007 through October 2008. Patients were included in the study if they had an adherent filter, refractory to standard retrieval techniques, and underwent high-risk retrieval after procedural risks were deemed lower than risks of long-term filter implantation. RESULTS Fourteen patients were diagnosed with an adherent filter, 13 (93%) of whom were candidates for high-risk retrieval. These patients included seven men and six women (mean age, 40 years; age range, 18-71 years). Nine of the 13 patients (69%) were referred from an outside hospital. Filter retrieval was performed for the following indications: to avoid the risk of long-term thrombotic complications in a young patient (n= 6), to treat symptomatic filter-related IVC stenosis (n= 5), to treat symptomatic filter penetration (n= 1), and to avoid the need for lifelong anticoagulation (n= 1). There were eight Günther-Tulip filters (mean dwell time, 356 days; range 53-1,181 days), two Optease filters (mean dwell time, 62 days; range, 52-72 days), one G2 filter (dwell time, 420 days), and two Recovery filters (mean dwell time, 1,630 days; range, 1,429-1,830 days). Three IVC occlusions necessitated recanalization to facilitate retrieval. High-risk retrieval with use of various techniques with aggressive force was successful in all 13 patients (100%). Partial caval thrombosis occurred in the first four patients (31%) but did not occur after procedural modifications were implemented. There were no complications at clinical follow-up (mean, 221 days; range, 84-452 days). CONCLUSIONS Alternative techniques can be used to retrieve adherent IVC filters implanted for up to 3-5 years. Although caval thrombosis was an observed complication, protocol modifications appeared to reduce this risk.


Journal of Vascular and Interventional Radiology | 2011

Imaging Guidance with C-arm CT: Prospective Evaluation of Its Impact on Patient Radiation Exposure during Transhepatic Arterial Chemoembolization

N. Kothary; M. Abdelmaksoud; A. Tognolini; Rebecca Fahrig; Jarrett Rosenberg; David M. Hovsepian; Arundhuti Ganguly; John D. Louie; William T. Kuo; Gloria L. Hwang; A.K. Holzer; Daniel Y. Sze; Lawrence V. Hofmann

PURPOSE To prospectively evaluate the impact of C-arm CT on radiation exposure to hepatocellular carcinoma (HCC) patients treated by chemoembolization. MATERIALS AND METHODS Patients with HCC (N = 87) underwent digital subtraction angiography (DSA; control group) or combined C-arm CT/DSA (test group) for chemoembolization. Dose-area product (DAP) and cumulative dose (CD) were measured for guidance and treatment verification. Contrast agent volume and C-arm CT utility were also measured. RESULTS The marginal DAP increase in the test group was offset by a substantial (50%) decrease in CD from DSA. Use of C-arm CT allowed reduction of DAP and CD from DSA imaging (P = .007 and P = .017). Experienced operators were more efficient in substituting C-arm CT for DSA, resulting in a negligible increase (7.5%) in total DAP for guidance, compared with an increase of 34% for all operators (P = .03). For treatment verification, DAP from C-arm CT exceeded that from DSA, approaching that of conventional CT. The test group used less contrast medium (P = .001), and C-arm CT provided critical or supplemental information in 20% and 17% of patients, respectively. CONCLUSIONS Routine use of C-arm CT can increase stochastic risk (DAP) but decrease deterministic risk (CD) from DSA. However, the increase in DAP is operator-dependent, thus, with experience, it can be reduced to under 10%. C-arm CT provides information not provided by DSA in 33% of patients, while decreasing the use of iodinated contrast medium. As with all radiation-emitting modalities, C-arm CT should be used judiciously.


Journal of Vascular and Interventional Radiology | 2010

Development of new hepaticoenteric collateral pathways after hepatic arterial skeletonization in preparation for yttrium-90 radioembolization.

M. Abdelmaksoud; Gloria L. Hwang; John D. Louie; N. Kothary; Lawrence V. Hofmann; William T. Kuo; David M. Hovsepian; Daniel Y. Sze

PURPOSE Development of new hepaticoenteric anastomotic vessels may occur after endovascular skeletonization of the hepatic artery. Left untreated, they can serve as pathways for nontarget radioembolization. The authors reviewed the incidence, anatomy, management, and significance of collateral vessel formation in patients undergoing radioembolization. MATERIALS AND METHODS One hundred thirty-eight treatments performed on 122 patients were reviewed. Each patient underwent a preparatory digital subtraction angiogram (DSA) and embolization of all hepaticoenteric vessels in preparation for yttrium-90 ((90)Y) administration. Successful skeletonization was verified by C-arm computed tomography (CACT) and technetium-99m macroaggregated albumin ((99m)TcMAA) scintigraphy. During the subsequent treatment session, DSA and CACT were repeated before administration of (90)Y, and the detection of extrahepatic perfusion prompted additional embolization. RESULTS Forty-two patients (34.4%) undergoing 43 treatments (31.2%) required adjunctive embolization of hepaticoenteric vessels immediately before (90)Y administration. Previous scintigraphy findings showed extrahepatic perfusion in only three cases (7.1%). Vessels were identified by DSA in 54.1%, by CACT in 4.9%, or required both in 41.0%. The time interval between angiograms did not correlate with risk of requiring reembolization (P = .297). A total of 19.7% of vessels were new collateral vessels not visible during the initial angiography. Despite reembolization, three patients (7.1%) had gastric or duodenal ulceration, compared with 1.3% who never had visible collateral vessels, all of whom underwent whole-liver treatment with resin microspheres (P = .038). CONCLUSIONS Development of collateral hepaticoenteric anastomoses occurs after endovascular skeletonization of the hepatic artery. Identified vessels may be managed by adjunctive embolization, but patients appear to remain at increased risk for gastrointestinal complications.


Journal of Vascular and Interventional Radiology | 2012

Percutaneous Cholecystostomy for Acute Cholecystitis: Ten-Year Experience

Tim Joseph; K. Unver; Gloria L. Hwang; Jarrett Rosenberg; Daniel Y. Sze; Syed Hashimi; N. Kothary; John D. Louie; William T. Kuo; Lawrence V. Hofmann; David M. Hovsepian

PURPOSE To review the clinical course of patients with acute cholecystitis treated by percutaneous cholecystostomy, and to identify risk factors retrospectively that predict outcome. MATERIALS AND METHODS A total of 106 patients diagnosed with acute cholecystitis were treated by percutaneous cholecystostomy during a 10-year period. Seventy-one (67%) presented to the emergency department (ED) specifically for acute cholecystitis, and 35 (23%) were inpatients previously admitted for other conditions. Outcomes of the two groups were compared with respect to severity of illness, leukocytosis, bile culture, liver function tests, imaging features, time intervals from onset of symptoms to medical and percutaneous intervention, and whether surgical cholecystectomy was later performed. RESULTS Overall, 72 patients (68%) showed an improvement clinically, whereas 34 (32%) showed no improvement or a clinically worsened condition after cholecystostomy. Patients who presented to the ED primarily with acute cholecystitis fared better (84% of patients showed improvement) than inpatients (34% showed improvement; P < .0001). Gallstones were identified in 54% of patients who presented to the ED, whereas acalculous cholecystitis was more commonly diagnosed in inpatients (54%). Patients with sepsis had worse outcomes overall (P < .0001). Bacterial bile cultures were analyzed in 95% of patients and showed positive results in 52%, with no overall effect on outcome. There was no correlation between the time of onset of symptoms until antibiotic therapy or cholecystostomy in either group. Long-term outcomes for both groups were better for those who later underwent cholecystectomy (P < .0001). CONCLUSIONS Outcomes after percutaneous cholecystostomy for acute cholecystitis are better when the disease is primary and not precipitated by concurrent illness.


Journal of Vascular and Interventional Radiology | 2011

Photothermal ablation with the excimer laser sheath technique for embedded inferior vena cava filter removal: initial results from a prospective study.

William T. Kuo; Justin I. Odegaard; John D. Louie; Daniel Y. Sze; K. Unver; N. Kothary; Jarrett Rosenberg; David M. Hovsepian; Gloria L. Hwang; Lawrence V. Hofmann

PURPOSE To evaluate the safety and effectiveness of the excimer laser sheath technique for removing embedded inferior vena cava (IVC) filters. MATERIALS AND METHODS Over 12 months, 25 consecutive patients undergoing attempted IVC filter retrieval with a laser-assisted sheath technique were prospectively enrolled into an institutional review board-approved study registry. There were 10 men and 15 women (mean age 50 years, range 20-76 years); 18 (72%) of 25 patients were referred from an outside hospital. Indications for retrieval included symptomatic filter-related acute caval thrombosis (with or without acute pulmonary embolism), chronic IVC occlusion, and bowel penetration. Retrieval was also performed to remove risks from prolonged implantation and potentially to eliminate need for lifelong anticoagulation. After failure of standard methods, controlled photothermal ablation of filter-adherent tissue with a Spectranetics laser sheath and CVX-300 laser system was performed. All patients were evaluated with cavography, and specimens were sent for histologic analysis. RESULTS Laser-assisted retrieval was successful in 24 (96%) of 25 patients as follows: 11 Günther Tulip (mean 375 days, range 127-882 days), 4 Celect (mean 387 days, range 332-440 days), 2 Option (mean 215 days, range 100-330 days), 4 OPTEASE (mean 387 days, range 71-749 days; 1 failed 188 days), 2 TRAPEASE (mean 871 days, range 187-1,555 days), and 2 Greenfield (mean 12.8 years, range 7.2-18.3 years). There was one (4%) major complication (acute thrombus, treated with thrombolysis), three (12%) minor complications (small extravasation, self-limited), and one adverse event (coagulopathic retroperitoneal hemorrhage) at follow-up (mean 126 days, range 13-302 days). Photothermal ablation of filter-adherent tissue was histologically confirmed in 23 (92%) of 25 patients. CONCLUSIONS The laser-assisted sheath technique appears to be a safe and effective tool for retrieving embedded IVC filters, including permanent types, with implantation ranging from months to > 18 years.


Journal of Vascular and Interventional Radiology | 2011

Embolization of parasitized extrahepatic arteries to reestablish intrahepatic arterial supply to tumors before yttrium-90 radioembolization.

M. Abdelmaksoud; John D. Louie; N. Kothary; Gloria L. Hwang; William T. Kuo; Lawrence V. Hofmann; David M. Hovsepian; Daniel Y. Sze

PURPOSE To perform embolization of parasitized extrahepatic arteries (EHAs) before radioembolization to reestablish intrahepatic arterial supply to large, peripheral tumors, and to evaluate the technical and clinical outcomes of this intervention. MATERIALS AND METHODS Among 201 patients retrospectively analyzed, embolization of 73 parasitized EHAs in 35 patients was performed. Most embolization procedures were performed during preparatory angiography using large particles and coils. Digital subtraction angiography (DSA), C-arm computed tomography (CT), and technetium-99m macroaggregated albumin ((99m)TcMAA) scintigraphy were used to evaluate the immediate perfusion via intrahepatic collateral channels of target tumor areas previously supplied by parasitized EHAs. Follow-up imaging of differential regional tumor response was used to evaluate microsphere distribution and clinical outcome. RESULTS After embolization, reestablishment of intrahepatic arterial supply was confirmed by both DSA and C-arm CT in 94% of territories and by scintigraphy in 96%. In 32% of patients, the differential response of treatment could not be evaluated because of uniform disease progression. However, symmetric regional tumor response in 94% of evaluable patients indicated successful delivery of microspheres to the territories previously supplied by parasitized EHAs. CONCLUSIONS Reestablishment of intrahepatic arterial inflow to hepatic tumors by embolization of parasitized EHAs is safe and effective and results in successful delivery of yttrium-90 microspheres to tumors previously perfused by parasitized EHAs.


Journal of Vascular and Interventional Radiology | 2008

Bidirectionally Adjustable TIPS Reduction by Parallel Stent and Stent-Graft Deployment

Daniel Y. Sze; Gloria L. Hwang; Jeffrey S. Kao; Joan K. Frisoli; Stephen T. Kee; Mahmood K. Razavi; Aijaz Ahmed

Excessive shunting through transjugular intrahepatic portosystemic shunts (TIPS) can cause life-threatening hepatic encephalopathy and insufficiency. Intentional reduction of flow may be effective but difficult to control. The present report describes refinements of the parallel stent/stent-graft technique of flow reduction that is adjustable in either direction. Six patients underwent TIPS reduction with varying stent positioning and a variety of commercial products. Flow was adjusted by iterative balloon dilatation of the stent and stent-graft, resulting in a mean gradient increase of 8 mm Hg. All cases were technically successful, but 1-year survival was seen in only the patient who underwent liver transplantation.


Journal of Vascular and Interventional Radiology | 2011

Consolidation of hepatic arterial inflow by embolization of variant hepatic arteries in preparation for yttrium-90 radioembolization.

M. Abdelmaksoud; John D. Louie; N. Kothary; Gloria L. Hwang; William T. Kuo; Lawrence V. Hofmann; David M. Hovsepian; Daniel Y. Sze

PURPOSE Before yttrium-90 ((90)Y) radioembolization administration, the authors consolidated arterial inflow by embolizing variant hepatic arteries (HAs) to make microsphere delivery simpler and safer. The present study reviews the technical and clinical success of these consolidation procedures. MATERIALS AND METHODS Preparatory and treatment angiograms were retrospectively analyzed for 201 patients. Variant HAs were coil-embolized during preparatory angiography to simplify arterial anatomy. Collateral arterial perfusion of territories previously supplied by variant HAs was evaluated by digital subtraction angiography (DSA), C-arm computed tomography (CT), and technetium-99m ((99m)Tc)-macroaggregated albumin (MAA) scintigraphy, and by follow-up evaluation of regional tumor response. RESULTS A total of 47 variant HAs were embolized in 43 patients. After embolization of variant HAs, cross-perfusion into the embolized territory was depicted by DSA and by C-arm CT in 100% of patients and by (99m)Tc-MAA scintigraphy in 92.7%. Uniform progressive disease prevented evaluation in 33% of patients, but regional tumor response in patients who responded supported successful delivery of microspheres to the embolized territories in 95.5% of evaluable patients. CONCLUSIONS Embolization of variant HAs for consolidation of hepatic supply in preparation for (90)Y radioembolization promotes treatment of affected territories via intrahepatic collateral channels.

Collaboration


Dive into the Gloria L. Hwang's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

A. Tognolini

University of California

View shared research outputs
Researchain Logo
Decentralizing Knowledge