Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Göran Kennebäck is active.

Publication


Featured researches published by Göran Kennebäck.


American Heart Journal | 1991

Electrophysiologic effects and clinical hazards of carbamazepine treatment for neurologic disorders in patients with abnormalities of the cardiac conduction system

Göran Kennebäck; Lennart Bergfeldt; Hans Vallin; Torbjörn Tomson; O. Edhag

Carbamazepine, a first-line drug for the treatment of epilepsy and neuralgia, may exert hazardous effects on the cardiac conduction system. Standard ECG and long-term ECG monitoring and invasive electrophysiologic testing were carried out in 10 patients who required this drug for neurologic disorders, but in whom its safe use had been questioned because of symptoms of ECG abnormalities. We observed depression of sinus node function and an atrioventricular conduction delay with a significant prolongation of the PQ interval of 16 msec (9%; 95% confidence interval: 1.9% to 16.5%; p less than 0.05), of which the HV interval was significantly prolonged but not the PA and AH intervals. These effects are in accordance with previously shown class 1A properties. However, the lack of effects on QRS, JT, and QT intervals at normal heart rates is a class 1B characteristic. Thus carbamazepine seems to have composite electropharmacologic actions. A cause effect relationship between carbamazepine treatment and significant arrhythmias was established in five patients. Thus the negative chronotropic and dromotropic effects of carbamazepine may, at least in predisposed patients, induce symptoms confusingly similar to the epileptic seizures it is used to prevent.


Seizure-european Journal of Epilepsy | 1997

Changes in arrhythmia profile and heart rate variability during abrupt withdrawal of antiepileptic drugs. Implications for sudden death

Göran Kennebäck; Mats Ericson; Torbjörn Tomson; Lennart Bergfeldt

Sudden unexpected death (SUD) has been associated with low or undetectable concentrations of antiepileptic drugs in patients with epilepsy suggesting that a sudden fall in plasma levels of these drugs might be a critical factor for the occurrence of SUD. We studied the changes in arrhythmia profile and heart-rate variability, during abrupt withdrawal of carbamazepine and phenytoin treatment in 10 patients with side effects on these drugs. Continuous ECG recording and daily measurements of drug plasma concentrations were performed from the last day of steady-state treatment and the following 4 days. Three patients had a 10-fold increase in ventricular premature beats. In addition, there was a significant reduction in heart-rate variability, assessed over 24 hours, in both the time (SDNN index, P = 0.03) and frequency domains from days 1-5. In the frequency domain analysis there was a significant reduction in total power (P = 0.01), very-low-frequency power (P = 0.004) and in low-frequency (LF) power (P = 0.01). Similar reductions in heart-rate variability and increases in ventricular automaticity have been associated with increased mortality in other patient groups. Two factors that might contribute to the increased rate of SUD in patients with epilepsy have thus been identified.


Cardiovascular Drugs and Therapy | 1995

Electrophysiological evaluation of the sodium-channel blocker carbamazepine in healthy human subjects

Göran Kennebäck; Lennart Bergfeldt; Torbjörn Tomson

SummaryCarbamazepine (CBZ) is a sodium-channel blocker used mainly for the treatment of epileptic seizures and neuralgias. It may impair the function of the cardiac conduction system in susceptible patients, but its electrophysiological effects have not been thoroughly assessed in the normal heart, which was the aim of the present study. Ten healthy volunteers, mean age 32 years, underwent two electrophysiological investigations at baseline and three at different dose levels of CBZ. The transesophageal atrial stimulation technique was used to evaluate sinus node function, refractoriness of the atrial myocardium, atrioventricular conduction, and ventricular depolarization and repolarization (as reflected by the QRS, JT, and QT intervals) at spontaneous rhythm and after atrial pacing. Atropine was administered to facilitate 1:1 conduction and assessment of rate-dependent effects. At the highest CBZ dose (800 mg/day), which gave plasma concentrations within the upper therapeutic range, the PQ interval was mildly prolonged (151 vs. 159 msec; p<0.01). In addition, the shortening of the JT interval normally seen at higher pacing rates was counteracted by high-dose CBZ, as demonstrated by a lower mean slope of the regression line after atropine and CBZ than after atropine alone (0.17 vs. 0.20; p<0.05). No other effects were detected. At therapeutic levels CBZ had minimal effects on the healthy conduction system, supporting its safe use in the absence of cardiac disease.


The Annals of Thoracic Surgery | 2003

Improved neurohormonal markers of ventricular function after restoring sinus rhythm by the Maze procedure

Anders Albåge; Göran Kennebäck; Jan van der Linden; Hans Berglund

BACKGROUND Clinical results of the Maze procedure for treatment of atrial fibrillation (AF) are excellent, suggesting improved ventricular function after restoring sinus rhythm. However, long-term corresponding effects on the release of cardiac natriuretic peptides and other vasoactive hormones are incompletely investigated after isolated Maze surgery. METHODS Plasma levels of brain natriuretic peptide (BNP), atrial natriuretic peptide (ANP), antidiuretic hormone, aldosterone, and angiotensin II were measured in 15 patients (mean age, 52 +/- 11 years) undergoing isolated surgical Maze (III) procedures for medically refractory AF, preoperatively and 6 months postoperatively. At the time of blood sampling, hemodynamic correlates were obtained at baseline and after 6 and 12 minutes of rapid ventricular pacing at 150 stimulations/minute. RESULTS All patients were free of AF at 6-month follow-up. The measured plasma levels of BNP, ANP, and angiotensin II were all significantly lower (p = 0.03) late after the isolated Maze procedure. Cardiac output was significantly higher postoperatively (p < 0.01). Other hemodynamic values and left atrial size were unchanged after surgery. Ventricular pacing caused almost identical hemodynamic changes in atrial pressures before and late after surgery, but the associated plasma ANP response was significantly attenuated postoperatively (p < 0.001). CONCLUSIONS Levels of cardiac natriuretic peptides and angiotensin II as markers of ventricular function are improved in the long term after clinically successful isolated Maze procedures. ANP response to hemodynamic challenge by ventricular pacing was attenuated postoperatively, possibly due to atrial scarring.


Epilepsy Research | 1992

Carbamazepine induced bradycardia - a problem in general or only in susceptible patients? A 24-h long-term electrocardiogram study

Göran Kennebäck; Lennart Bergfeldt; Torbjörn Tomson; E Spina; O. Edhag

Carbamazepine is a first line drug in the treatment of epilepsy and trigeminal neuralgia, but may exert negative chronotropic and dromotropic effects on the cardiac conduction system. Bradyarrhythmias of different types and severity have been described, especially in the elderly, but the prevalence of arrhythmias in a larger group of carbamazepine treated patients is unknown. Forty-eight patients, 40 years of older, on continuous carbamazepine treatment because of various neurologic disorders were investigated by interview, physical examination, 12-lead surface electrocardiogram, and 24-h long-term electrocardiogram recording. The prevalence of bradyarrhythmias was compared with that in an age-stratified reference group. There was no differences between the two groups, either in the number or the duration of pauses or in the type of pauses. In conclusion, carbamazepine does not increase the risk of bradyarrhythmias in the vast majority of patients.


Europace | 2013

Cryothermal vs. radiofrequency ablation as atrial flutter therapy: a randomized comparison.

Hamid Bastani; Nikola Drca; Per Insulander; Schwieler J; Frieder Braunschweig; Göran Kennebäck; Bita Sadigh; Jari Tapanainen; Mats Jensen-Urstad

AIMS Radiofrequency (RF) ablation of the cavotricuspid isthmus (CTI) is an effective treatment for atrial flutter (AFL). However, RF may injure cardiac structures such as the atrio-ventricular node or the right coronary artery and is usually painful. This prospective, randomized study compares cryoablation (Cryo) with RF ablation regarding efficacy, safety, and perceived pain. METHODS AND RESULTS One-hundred and fifty-three patients (78 Cryo; 75 RF) with CTI-dependent AFL--median age 65 years (range 34-82), 140 men (91%)--were randomized to Cryo or RF. Primary endpoint was demonstration of long-term efficacy defined as no symptomatic recurrence of AFL at the 6-month follow-up. Radiofrequency ablation was performed with a 3.5 mm open-irrigated-tip catheter and Cryo with a 9 F, 8 mm tip catheter. Ablation endpoint was bidirectional CTI block. Pain was evaluated with a visual analogue scale (VAS; 0-10). The acute success rate was 92% for Cryo and 95% for RF (P = 0.58). Procedural time was longer in the Cryo group (152 ± 54 min) than the RF group (116 ± 41 min) (P < 0.001). Cryoablation was considerably less painful compared with RF (mean VAS-Cryo 0.7 ± 1.2 vs. VAS-RF 4.6 ± 2.0; P < 0.001). Success rate at 6-month follow-up was 93% (73 of 78) for Cryo and 97% (73 of 75) for RF (P = 0.86). No major adverse events occurred in any group. CONCLUSION Cryoablation of isthmus-dependent AFL is not inferior to RF but with significantly less procedure-related pain.


Scandinavian Cardiovascular Journal | 2000

The Maze operation for treatment of atrial fibrillation. Early clinical experience in a Scandinavian institution.

Anders Albåge; Jan van der Linden; Dan Lindblom; Göran Kennebäck; Anders T. Nygren; Jan Svedenhag; Lars Bengtsson

The Maze operation is a potentially curative surgical option in patients with disabling atrial fibrillation (AF) refractory to conventional treatment. The aim of this study was to evaluate the initial 4-year Maze experience in our institution. The study included 26 patients (19 males, mean age 55 years) who had undergone the Maze (III) operation between 1994 and 1998. Nine patients had surgery for concomitant heart disease. Follow-up was 3-55 (median 18) months. No deaths or neurological complications occurred; 22 patients are at present in regular sinus-, or junctional rhythm, 2 patients have permanent atrial pacing for symptomatic sinus node dysfunction, and 2 patients have had persistent AF, post surgery. Sinus node dysfunctions were detected in five patients, though not requiring pacemakers. Out of the total 26 patients, 23 are free of anti-arrhythmic drugs. Echocardiographic signs of left atrial contraction were recorded in 50% of the patients. The Maze operation offers a safe alternative to conventional therapy, with attractive results justifying expansion in the use of this treatment for AF.The Maze operation is a potentially curative surgical option in patients with disabling atrial fibrillation (AF) refractory to conventional treatment. The aim of this study was to evaluate the initial 4-year Maze experience in our institution. The study included 26 patients (19 males, mean age 55 years) who had undergone the Maze (III) operation between 1994 and 1998. Nine patients had surgery for concomitant heart disease. Follow-up was 3-55 (median 18) months. No deaths or neurological complications occurred; 22 patients are at present in regular sinus-, or junctional rhythm, 2 patients have permanent atrial pacing for symptomatic sinus node dysfunction, and 2 patients have had persistent AF, post surgery. Sinus node dysfunctions were detected in five patients, though not requiring pacemakers. Out of the total 26 patients, 23 are free of anti-arrhythmic drugs. Echocardiographic signs of left atrial contraction were recorded in 50% of the patients. The Maze operation offers a safe alternative to conventional therapy, with attractive results justifying expansion in the use of this treatment for AF.


The Annals of Thoracic Surgery | 2001

Elevations in antidiuretic hormone and aldosterone as possible causes of fluid retention in the Maze procedure

Anders Albåge; Jan van der Linden; Lars Bengtsson; Dan Lindblom; Göran Kennebäck; Hans Berglund

BACKGROUND Reduced levels of atrial natriuretic peptide (ANP) has been suggested as a cause of fluid retention after combined Maze and valvular surgery. This study aimed to assess hormonal activation in the perioperative setting of isolated Maze procedures. METHODS Changes in ANP, brain natriuretic peptide (BNP), antidiuretic hormone (ADH), aldosterone, and angiotensin II were measured in 16 patients (mean age 53+/-9 years) without concomitant heart disease undergoing the Maze (III) procedure. Ten matched patients (mean age 56+/-9 years) undergoing multivessel coronary artery bypass grafting served as controls. Measurements with hemodynamic correlates were obtained at baseline and after ventricular pacing (100 stimulations/minute), directly preoperatively, postoperatively and the first postoperative day. Weight gain and diuretic requirements were recorded. RESULTS The major differences in hormonal response were significantly higher plasma levels of ADH (Maze preoperative 1.1+/-0.4, postoperative 24.9+/-16.7 pmol/L; controls preoperative 1.1+/-0.1, postoperative 3.7+/-3.5 pmol/L) and aldosterone (Maze preoperative 106+/-94, postoperative 678+/-343 pmol/L; controls preoperative 124+/-79, postoperative 171+/-93 pmol/L) in the Maze group on the first postoperative day (p < 0.001). Preoperative baseline plasma levels of ANP and pulmonary capillary wedge pressures (PCWP) were higher in the Maze group but this difference was abolished by pacing, and postoperatively, ANP levels changed in parallel to the PCWP in both groups. Diuretic requirements were significantly higher in the Maze group. CONCLUSIONS Substantial increases in ADH and aldosterone were observed after the Maze procedure, indicating these hormones as important determinants in postoperative fluid retention. The role for ANP in this setting may be a less prominent than previously reported.


Pacing and Clinical Electrophysiology | 2004

Electrophysiological evaluation of the sinus node and the cardiac conduction system following the maze procedure for atrial fibrillation.

Anders Albåge; Dan Lindblom; Per Insulander; Göran Kennebäck

Transient sinus node dysfunction has been demonstrated by noninvasive methods following the maze procedure for atrial fibrillation (AF). However, extensive data from invasive electrophysiological studies have not been previously reported. Thirty‐seven patients, mean age 54 ± 10 years, underwent the maze (III) procedure. Electrophysiological studies with recordings of SNRT, CSNRT, AVN‐ERP, point of Wenckebach block, AH, PA, and HV interval, were performed preoperatively and 6 and 15 months postoperatively. Induction of atrial flutter/AF was attempted postoperatively. Based on electrophysiological study evaluation, the maze (III) procedure did not cause permanent damage to the sinus node in any patient with a documented normal sinus node function preoperatively (CSNRT max 541 ± 210 vs 587 ± 437 ms, P = 0.26). Postoperative AV node function was normal in all patients with a documented normal AV node function before surgery. One patient had an iatrogenic third degree AV block. There was no difference in PA or HV interval after surgery. Sustained atrial tachyarrhythmias could be induced in 5 patients, of whom 4 developed permanent AF/atrial flutter late after surgery. At late follow‐up, (mean 45 months), 27 (73%) patients were in sinus rhythm, 5 (13%) patients had permanent pacing, and 5 patients had recurrent AF requiring His bundle ablation (n = 2) or medical treatment (n = 3). Based on electrophysiological studies, the maze (III) procedure does not cause permanent damage to the sinus or AV nodes or to the right atrial and His‐Purkinje conduction systems. Electrophysiological study evaluation may predict the need for postoperative pacemaker. Induction attempts of atrial arrhythmias may predict future recurrences and guide therapeutic efforts. (PACE 2004; 27:194–203)


Journal of Interventional Cardiology | 2002

Catheter-based transendocardial myocardial gene transfer.

Christer Sylvénm.D.; Nondita Sarkar; Per Insulander; Göran Kennebäck; Pontus Blomberg; Khalid B. Islam; Viktor Drvota

Collaboration


Dive into the Göran Kennebäck's collaboration.

Top Co-Authors

Avatar

Per Insulander

Karolinska University Hospital

View shared research outputs
Top Co-Authors

Avatar

Anders Albåge

Karolinska University Hospital

View shared research outputs
Top Co-Authors

Avatar

Frieder Braunschweig

Karolinska University Hospital

View shared research outputs
Top Co-Authors

Avatar

Dan Lindblom

Karolinska University Hospital

View shared research outputs
Top Co-Authors

Avatar

Hamid Bastani

Karolinska University Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge