Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Goran Simic is active.

Publication


Featured researches published by Goran Simic.


Journal of Electrocardiology | 2012

Wireless remote monitoring of reconstructed 12-lead ECGs after ablation for atrial fibrillation using a hand-held device

Ihor Gussak; Dejan Vukajlovic; Vladan Vukcevic; Samuel E. George; Bosko Bojovic; Ljupco Hadzievski; Goran Simic; Bojan Stojanovic; Lazar Angelkov; Dorin Panescu

OBJECTIVE Atrial fibrillation (AF) surveillance using a wireless handheld monitor capable of 12-lead electrocardiogram reconstruction was performed, and arrhythmia detection rate was compared with serial Holter monitoring. METHODS Twenty-five patients were monitored after an AF ablation procedure using the hand-held monitor for 2 months immediately after and then for 1 month approximately 6 months postablation. All patients underwent 12-lead 24-hour Holter monitoring at 1, 2, and 6 months postablation. RESULTS During months 1-2, 425 of 2942 hand-held monitor transmissions from 21 of 25 patients showed AF/atrial flutter (Afl). The frequency of detected arrhythmias decreased by month 6 to 85/1128 (P < .01) in 15 of 23 patients. Holter monitoring diagnosed AF/Afl in 8 of 25 and 7 of 23 patients at months 1-2 and month 6, respectively (P < .01 compared with wireless hand-held monitor). Af/Afl diagnosis by wireless monitoring preceded Holter detection by an average of 24 days. CONCLUSIONS Wireless monitoring with 12-lead electrocardiogram reconstruction demonstrated reliable AF/Afl detection that was more sensitive than serial 12-lead 24-hour Holter monitoring.


Experimental Techniques | 2014

Experimental Research of Characteristics of Modified Tube Absorbers of Kinetic Collision Energy of Passenger Coaches

J. Tanasković; Vojkan Lučanin; Dragan Milković; Goran Simic; M. Miloš

Development of elements for absorption of collision energy of railway vehicles represent an important segment in the design of new and restoration of existing railway passenger coaches. Absorption elements are part of passive protection measures used railway vehicles. Passive protection role is achieved when crash repercussions during impact are minimized. In this article, the analysis of the characteristics of modified tube absorbers for kinetic collision energy of passenger coaches is performed. The research focuses on quasi-static tests and dynamic tests. The presented solution is based on the use of steel tube elements that absorb a certain amount of collision energy of passenger coaches by controlled plastic deformation. The modified tube absorber is installed in a row with a standard buffer for passenger coaches. Given the results obtained, a final evaluation of this type of absorber is done. In addition, proposal for further research is offered with the goal to increase the safety level in railway traffic.


international conference of the ieee engineering in medicine and biology society | 2013

A new method for respiratory-volume monitoring based on long-period fibre gratings

Marija Petrovic; Jovana Petrović; Goran Simic; Igor Ilić; Aleksandar Danicic; Miodrag Vukcevic; Bosko Bojovic; Ljupco Hadzievski; Thomas D.P. Allsop; David J. Webb

Respiratory-volume monitoring is an indispensable part of mechanical ventilation. Here we present a new method of the respiratory-volume measurement based on a single fibre-optical long-period sensor of bending and the correlation between torso curvature and lung volume. Unlike the commonly used air-flow based measurement methods the proposed sensor is drift-free and immune to air-leaks. In the paper, we explain the working principle of sensors, a two-step calibration-test measurement procedure and present results that establish a linear correlation between the change in the local thorax curvature and the change of the lung volume. We also discuss the advantages and limitations of these sensors with respect to the current standards.


international conference of the ieee engineering in medicine and biology society | 2011

Wireless monitoring of reconstructed 12-lead ECG in atrial fibrillation patients enables differential diagnosis of recurrent arrhythmias

Dejan Vukajlovic; Ihor Gussak; Samuel E. George; Goran Simic; Bosko Bojovic; Ljupco Hadzievski; Bojan Stojanovic; Lazar Angelkov; Dorin Panescu

Differential diagnosis of symptomatic events in post-ablation atrial fibrillation (AF) patients (pts) is important; in particular, accurate, reliable detection of AF or atrial flutter (AFL) is essential. However, existing remote monitoring devices usually require attached leads and are not suitable for prolonged monitoring; moreover, most do not provide sufficient information to assess atrial activity, since they generally monitor only 1–3 ECG leads and rely on RR interval variability for AF diagnosis. A new hand-held, wireless, symptom-activated event monitor (CardioBip; CB) does not require attached leads and hence can be conveniently used for extended periods. Moreover, CB provides data that enables remote reconstruction of full 12-lead ECG data including atrial signal information. We hypothesized that these CB features would enable accurate remote differential diagnosis of symptomatic arrhythmias in post-ablation AF pts. Methods: 21 pts who underwent catheter ablation for AF were instructed to make a CB transmission (TX) whenever palpitations, lightheadedness, or similar symptoms occurred, and at multiple times daily when asymptomatic, during a 60 day post-ablation time period. CB transmissions (TXs) were analyzed blindly by 2 expert readers, with differences adjudicated by consensus. Results: 7 pts had no symptomatic episodes during the monitoring period. 14 of 21 pts had symptomatic events and made a total of 1699 TX, 164 of which were during symptoms. TX quality was acceptable for rhythm diagnosis and atrial activity in 96%. 118 TX from 10 symptomatic pts showed AF (96 TX from 10 pts) or AFL (22 TX from 3 pts), and 46 TX from 9 pts showed frequent PACs or PVCs. No other arrhythmias were detected. Five pts made symptomatic TX during AF/AFL and also during PACs/PVCs. Conclusions: Use of CB during symptomatic episodes enabled detection and differential diagnosis of symptomatic arrhythmias. The ability of CB to provide accurate reconstruction of 12 L ECGs including atrial activity, combined with its ease of use, makes it suitable for long-term surveillance for recurrent AF in post-ablation patients.


international conference of the ieee engineering in medicine and biology society | 2011

Algorithm for quantitative 3 dimensional analysis of ECG signals improves myocardial diagnosis over cardiologists in diabetic patients

Brian J. Wenzel; Samuel E. George; Dhanunjaya Lakkireddy; Subba Reddy Vanga; Sudha Bommana; Ihor Gussak; Goran Simic; Bosko Bojovic; Ljupco Hadzievski; Dorin Panescu

Acute myocardial infarction (AMI) diagnosis in type II diabetes (DM2) patients is difficult and ECG findings are often non-diagnostic or inconclusive. We developed computer algorithms to process standard 12-lead ECG input data for quantitative 3-dimensional (3D) analysis (my3KGTM), and hypothesized that use of the my3KGTMs array of over 100 3D-based AMI diagnostic markers may improve diagnostic accuracy for AMI in DM2 patients. Methods: We identified 155 consecutive DM2 patients age >25 yrs with chest discomfort or shortness of breath who were evaluated at an urban emergency department (130 patients (pts)) or the cardiac catheterization laboratory (25 pts) for possible AMI. The first digital 12-lead ECG for each patient, obtained within 30 min of presentation, was evaluated by (1) 2 blinded expert cardiologists, and (2) my3KGTM. In each case, the ECG was classified as either likely AMI or likely non-AMI. “Gold standard” was the final clinical diagnosis. Statistical analysis was McNemars test with continuity correction. Results: The 155 DM2 patients were 50% male, mean age 56.8 ± 12.0 yrs; 44 pts had a final clinical diagnosis of AMI (17 ST Elevation Myocardial Infarctions (STEMI), 27 Non-ST Elevation Myocardial Infarctions (NSTEMI)) and 111 had no AMI. Conclusions: Relative to standard 12L ECG read by cardiologists, quantitative 3D ECG analysis showed significant and substantial gains in sensitivity for AMI diagnosis in DM2 patients, without loss in specificity. Sensitivity gains were particularly high in patients exhibiting NSTEMI, the most common form of AMI in DM2.


Engineering Failure Analysis | 2009

Cracks, repair and reconstruction of bucket wheel excavator slewing platform

Srđan Bošnjak; Zoran Petković; Nenad Zrnić; Goran Simic; Aleksandar Simonović


Measurement | 2013

Wayside system for wheel–rail contact forces measurements

Dragan Milković; Goran Simic; Ž. Jakovljević; Jovan Tanasković; Vojkan Lučanin


Experimental Techniques | 2009

EXPERIMENTAL RESEARCH OF CHARACTERISTICS OF SHOCK ABSORBERS OF IMPACT ENERGY OF PASSENGER COACHES

Goran Simic; Vojkan Lučanin; J. Tanasković; N. Radović


Engineering Failure Analysis | 2010

Calculated and experimental analysis of cause of the appearance of cracks in the running bogie frame of diesel multiple units of Serbian railways

Vojkan Lučanin; Goran Simic; Dragan Milković; Nenad Lj Ćuprić; Snežana Golubović


Facta Universitatis, Series: Mechanical Engineering | 2015

EXPERIMENTAL AND NUMERICAL DETERMINATION OF THE WHEEL-RAIL ANGLE OF ATTACK

Dragan Milković; Goran Simic; Jovan Tanasković; Živana Jakovljević; Vojkan Lučanin

Collaboration


Dive into the Goran Simic's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bernhard Rüger

Vienna University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge