Featured researches published by Graham Sommer.


Magnetic Resonance in Medicine | 2004

Referenceless PRF shift thermometry

Viola Rieke; Karl K. Vigen; Graham Sommer; Bruce L. Daniel; John M. Pauly; Kim Butts

The proton resonance frequency (PRF) shift provides a means of measuring temperature changes during minimally invasive thermotherapy. However, conventional PRF thermometry relies on the subtraction of baseline images, which makes it sensitive to tissue motion and frequency drift during the course of treatment. In this study, a new method is presented that eliminates these problems by estimating the background phase from each acquired image phase. In this referenceless method, a polynomial is fit to the background phase outside the heated region in a weighted least‐squares fit. Extrapolation of the polynomial to the heated region serves as the background phase estimate, which is then subtracted from the actual phase. The referenceless method is demonstrated on a phantom during laser heating, 0° temperature rise images of in vivo human liver, interstitial laser ablation of porcine liver, and transurethral ultrasound ablation of canine prostate. A good correlation between temperature maps reconstructed with the referenceless and subtraction methods was found. Magn Reson Med 51:1223–1231, 2004.


American Journal of Roentgenology | 2007

Split-Bolus MDCT Urography with Synchronous Nephrographic and Excretory Phase Enhancement

Lawrence C. Chow; Sharon Kwan; Eric W. Olcott; Graham Sommer

OBJECTIVE Our purpose was to evaluate the utility of CT urography performed using a split contrast bolus that yields synchronous nephrographic and excretory phase enhancement. MATERIALS AND METHODS Five hundred consecutive patients referred for evaluation of possible urinary tract abnormalities (327 for painless hematuria) underwent CT urography with unenhanced scanning of the abdomen and pelvis and scanning during concurrent nephrographic and excretory phase enhancement produced by administration of a split contrast bolus. The enhanced abdomen scan was obtained with abdominal compression; the enhanced pelvis scan was obtained after release of compression. Findings from axial sections and coronal maximum intensity projections were correlated with clinical follow-up and, as available, with laboratory and other imaging studies including cystoscopy, ureteroscopy, urine cytology, surgery, and pathology. Follow-up management for each patient was determined by the clinical judgment of the referring physician. RESULTS CT urography identified 100% of pathologically confirmed renal cell carcinomas (n = 10) and uroepithelial malignancies involving the renal collecting system or ureter (n = 8). An additional nine renal masses were identified for which no pathologic proof has yet been obtained, including eight subcentimeter solid renal masses and one multiloculated lesion. Fourteen of 19 confirmed cases of uroepithelial neoplasm involving the bladder were identified. CT urography yielded one false-positive for bladder tumor, two false-positives for ureteral tumor, and one patient with a bladder mass who refused further evaluation. CT urography yielded sensitivity and specificity of 100% and 99% and 74% and 99% and positive predictive value and negative predictive value of 80% and 100% and 93% and 99% for the renal collecting system and ureter and bladder, respectively. CT urography was ineffective in identifying 11 cases of noninfectious cystitis. CT urography also depicted numerous other congenital and acquired abnormalities of the urinary tract. CONCLUSION Split-bolus MDCT urography detected all proven cases of tumors of the upper urinary tract, yielding high sensitivity and specificity. The split-bolus technique has the potential to reduce both radiation dose and the number of images generated by MDCT urography.


IEEE Transactions on Medical Imaging | 2007

Referenceless MR Thermometry for Monitoring Thermal Ablation in the Prostate

Viola Rieke; Adam M. Kinsey; Anthony B. Ross; William H. Nau; Chris J. Diederich; Graham Sommer; Kim Butts Pauly

Referenceless proton resonance frequency (PRF) shift thermometry provides a means to measure temperature changes during minimally invasive thermotherapy that is inherently robust to motion and tissue displacement. However, if the referenceless method is used to determine temperature changes during prostate ablation, phase gaps between water and fat in image regions used to determine the background phase can confound the phase estimation. We demonstrate an extension to referenceless thermometry which eliminates this problem by allowing background phase estimation in the presence of phase discontinuities between aqueous and fatty tissue. In this method, images are acquired with a multi-echo sequence and binary water and fat maps are generated from a Dixon reconstruction. For the background phase estimation, water and fat regions are treated separately and the phase offset between the two tissue types is determined. The method is demonstrated feasibile in phantoms and during in vivo thermal ablation of canine prostate.


Topics in Magnetic Resonance Imaging | 2006

Magnetic resonance-guided high-intensity ultrasound ablation of the prostate.

Kim Butts Pauly; Chris J. Diederich; Viola Rieke; Donna M. Bouley; Jing Chen; Will H. Nau; Anthony B. Ross; Adam M. Kinsey; Graham Sommer

Objectives: This paper describes our work in developing techniques and devices for magnetic resonance (MR)-guided high-intensity ultrasound ablation of the prostate and includes review of relevant literature. Methods: Catheter-based high-intensity ultrasound applicators, in interstitial and transurethral configurations, were developed to be used under MR guidance. Magnetic resonance thermometry and the relevant characteristics and artifacts were evaluated during in vivo thermal ablation of the prostate in 10 animals. Contrast-enhanced MR imaging (MRI) and diffusion-weighted MRI were used to assess tissue damage and compared with histology. Results: During evaluation of these applicators, MR thermometry was used to monitor the temperature distributions in the prostate in real time. Magnetic resonance-derived maximum temperature thresholds of 52°C and thermal dose thresholds of 240 minutes were used to control the extent of treatment and qualitatively correlated well with posttreatment imaging studies and histology. The directional transurethral devices are selective in their ability to target well-defined regions of the prostate gland and can be rotated in discrete steps to conform treatment to prescribed boundaries. The curvilinear applicator is the most precise of these directional techniques. Multisectored transurethral applicators, with dynamic angular control of heating and no rotation requirements, offer a fast and less complex means of treatment with less selective contouring. Conclusions: The catheter-based ultrasound devices can produce spatially selective regions of thermal destruction in prostate. The MR thermal imaging and thermal dose maps, obtained in multiple slices through the target volume, are useful for controlling therapy delivery (rotation, power levels, duration). Contrast-enhanced T1-weighted MRI and diffusion-weighted imaging are useful tools for assessing treatment.


Physics in Medicine and Biology | 2004

Highly directional transurethral ultrasound applicators with rotational control for MRI-guided prostatic thermal therapy.

Anthony B. Ross; Chris J. Diederich; William H. Nau; Harcharan Gill; Donna M. Bouley; Bruce L. Daniel; Viola Rieke; R. Kim Butts; Graham Sommer

Transurethral ultrasound applicators with highly directional energy deposition and rotational control were investigated for precise treatment of benign prostatic hyperplasia (BPH) and adenocarcinoma of the prostate (CaP). Two types of catheter-based applicators were fabricated, using either 90 degrees sectored tubular (3.5 mm OD x 10 mm) or planar transducers (3.5 mm x 10 mm). They were constructed to be MRI compatible, minimally invasive and allow for manual rotation of the transducer array within a 10 mm cooling balloon. In vivo evaluations of the applicators were performed in canine prostates (n = 3) using MRI guidance (0.5 T interventional magnet). MR temperature imaging (MRTI) utilizing the proton resonance frequency shift method was used to acquire multiple-slice temperature overlays in real time for monitoring and guiding the thermal treatments. Post-treatment T1-weighted contrast-enhanced imaging and triphenyl tetrazolium chloride stained tissue sections were used to define regions of tissue coagulation. Single sonications with the 90 degrees tubular applicator (9-15 W, 12 min, 8 MHz) produced coagulated zones covering an 80 degrees wedge of the prostate extending from 1-2 mm outside the urethra to the outer boundary of the gland (16 mm radial coagulation). Single sonications with the planar applicator (15-20 W, 10 min, approximately 8 MHz) generated thermal lesions of approximately 30 degrees extending to the prostate boundary. Multiple sequential sonications (sweeping) of a planar applicator (12 W with eight rotations of 30 degrees each) demonstrated controllable coagulation of a 270 degrees contiguous section of the prostate extending to the capsule boundary. The feasibility of using highly directional transurethral ultrasound applicators with rotational capabilities to selectively coagulate regions of the prostate while monitoring and controlling the treatments with MRTI was demonstrated in this study.


Medical Physics | 2005

MRI-guided interstitial ultrasound thermal therapy of the prostate: A feasibility study in the canine model

William H. Nau; Chris J. Diederich; Anthony B. Ross; Kim Butts; Viola Rieke; Donna M. Bouley; Harcharan Gill; Bruce L. Daniel; Graham Sommer

The feasibility of MRI-guided interstitial ultrasound thermal therapy of the prostate was evaluated in an in vivo canine prostate model. MRI compatible, multielement interstitial ultrasound applicators were developed using 1.5 mm diameter cylindrical piezoceramic transducers (7 to 8 MHz) sectored to provide 180 degrees of angular directional heating. Two in vivo experiments were performed in canine prostate. The first using two interstitial ultrasound applicators, the second using three ultrasound applicators in conjunction with rectal and urethral cooling. In both experiments, the applicators were inserted transperineally into the prostate with the energy directed ventrally, away from the rectum. Electrical power levels of 5-17 W per element (approximately 1.6-5.4 W acoustic output power) were applied for heating periods of 18 and 48 min. Phase-sensitive gradient-echo MR imaging was used to monitor the thermal treatment in real-time on a 0.5 T interventional MRI system. Contrast-enhanced T1-weighted images and vital-stained serial tissue sections were obtained to assess thermal damage and correlate to real-time thermal contour plots and calculated thermal doses. Results from these studies indicated a large volume of ablated (nonstained) tissue within the prostate, extending 1.2 to 2.0 cm from the applicators to the periphery of the gland, with the dorsal margin of coagulation well-defined by the applicator placement and directionality. The shape of the lesions correlated well to the hypointense regions visible in the contrast-enhanced T1-weighted images, and were also in good agreement with the contours of the 52 degrees C threshold temperature and t43 > 240 min. This study demonstrates the feasibility of using directional interstitial ultrasound in conjunction with MRI thermal imaging to monitor and possibly control thermal coagulation within a targeted tissue volume while potentially protecting surrounding tissue, such as rectum, from thermal damage.


International Journal of Hyperthermia | 2004

Catheter-based ultrasound applicators for selective thermal ablation: progress towards MRI-guided applications in prostate

Chris J. Diederich; William H. Nau; Anthony B. Ross; Per Daniel Tyreus; Kim Butts; Viola Rieke; Graham Sommer

High-temperature thermal therapy is emerging as a feasible treatment option for prostate cancer and benign prostatic hyperplasia. Previous investigations have demonstrated distinct advantages of catheter-based ultrasound technology over other heating modalities for thermal ablation therapies, with significant potential for better spatial control and faster heating times. The purpose of this study was to develop ultrasound devices and techniques specifically for treating prostate cancer in conjunction with magnetic resonance thermal imaging (MRTI) to monitor and control treatment progression. Directional transurethral applicators have been designed with arrays of sectored tubular (90° active acoustic sector) or with narrow planar transducer segments and integrated with a flexible delivery catheter with a cooling balloon. This applicator can be rotated within the prostatic urethra to target specific regions during treatment. MRI compatible catheter-cooled interstitial ultrasound applicators with 180° active acoustic sectors were developed specifically to treat the prostate. These applicators may be implanted through the perineum into the posterior portion of the prostate, with their heating energy directed away from the rectum. Both heating strategies were evaluated via biothermal simulations and in vivo experiments within canine prostate (n = 3). During the in vivo studies, MRTI was used to monitor treatment temperatures, cytotoxic thermal doses (t43>240 min) and corresponding maximum temperature thresholds (Tmax>52°C) within three imaging planes simultaneously. Urethral and endorectal cooling was employed with both treatment strategies to provide further protection of the urethral mucosa and rectum from thermal damage. Results using the transurethral applicators demonstrated that narrow zones of coagulation (∼30° sector for planar, ∼90° for tubular), extending up to 20 mm from the urethra to the periphery of the prostate gland, could be produced within 10–15 min. Further, rotation of the applicator during treatment could be used to destroy larger regions in the prostate. Experiments using multiple interstitial directional applicators (∼180° active sectors), implanted within the posterior margin of the prostate with the energy directed away from the rectum, produced contiguous zones of thermal coagulation which extended from the posterior prostate toward the anterior-lateral periphery of the gland. Both transurethral and interstitial treatment strategies demonstrated significant potential for thermal ablation of localized prostate cancer, particularly when MRTI is used to guide and assess treatment.


Magnetic Resonance in Medicine | 2008

Monitoring Prostate Thermal Therapy with Diffusion-Weighted MRI

Jing Chen; Bruce L. Daniel; Chris J. Diederich; Donna M. Bouley; Maurice A. A. J. van den Bosch; Adam M. Kinsey; Graham Sommer; Kim Butts Pauly

For MR‐guided minimally invasive therapies, it is important to have a repeatable and reliable tissue viability evaluation method. The use of diffusion‐weighted MRI (DWI) to evaluate tissue damage was assessed in 19 canine prostates with cryoablation or high‐intensity ultrasound (HIU) ablation. The apparent diffusion coefficient (ADC) trace value was measured in the treated tissue immediately upon the procedure and on the posttreatment follow‐up. For the acute lesions, the ADC value decreased to (1.05 ± 0.25) × 10–3 mm2/s, as compared to (1.64 ± 0.24) × 10–3 mm2/s before the treatment. There was no statistical difference between previously frozen or previously ultrasound‐heated lesions in terms of the 36% ADC reduction (P = 0.66). The ADC decrease occurred early during the course of the treatment, which appears to complicate DWI‐based thermometry. Over time, the ADC value increased as the tissue recovered and regenerated. This study shows that DWI could be a promising method to monitor prostate thermal therapies and to provide insight on tissue damage and tissue remodeling after injury. Magn Reson Med 59:1365–1372, 2008.


Medical Physics | 2008

Transurethral ultrasound applicators with dynamic multi-sector control for prostate thermal therapy: In vivo evaluation under MR guidance

Adam M. Kinsey; Chris J. Diederich; Viola Rieke; William H. Nau; Kim Butts Pauly; Donna M. Bouley; Graham Sommer

The purpose of this study was to explore the feasibility and performance of a multi-sectored tubular array transurethral ultrasound applicator for prostate thermal therapy, with potential to provide dynamic angular and length control of heating under MR guidance without mechanical movement of the applicator. Test configurations were fabricated, incorporating a linear array of two multi-sectored tubular transducers (7.8-8.4 MHz, 3 mm OD, 6 mm length), with three 120 degrees independent active sectors per tube. A flexible delivery catheter facilitated water cooling (100 ml min(-1)) within an expandable urethral balloon (35 mm long x 10 mm diameter). An integrated positioning hub allows for rotating and translating the transducer assembly within the urethral balloon for final targeting prior to therapy delivery. Rotational beam plots indicate approximately 90 degrees-100 degrees acoustic output patterns from each 120 degrees transducer sector, negligible coupling between sectors, and acoustic efficiencies between 41% and 53%. Experiments were performed within in vivo canine prostate (n = 3), with real-time MR temperature monitoring in either the axial or coronal planes to facilitate control of the heating profiles and provide thermal dosimetry for performance assessment. Gross inspection of serial sections of treated prostate, exposed to TTC (triphenyl tetrazolium chloride) tissue viability stain, allowed for direct assessment of the extent of thermal coagulation. These devices created large contiguous thermal lesions (defined by 52 degrees C maximum temperature, t43 = 240 min thermal dose contours, and TTC tissue sections) that extended radially from the applicator toward the border of the prostate (approximately15 mm) during a short power application (approximately 8-16 W per active sector, 8-15 min), with approximately 200 degrees or 360 degrees sector coagulation demonstrated depending upon the activation scheme. Analysis of transient temperature profiles indicated progression of lethal temperature and thermal dose contours initially centered on each sector that coalesced within approximately 5 min to produce uniform and contiguous zones of thermal destruction between sectors, with smooth outer boundaries and continued radial propagation in time. The dimension of the coagulation zone along the applicator was well-defined by positioning and active array length. Although not as precise as rotating planar and curvilinear devices currently under development for MR-guided procedures, advantages of these multi-sectored transurethral applicators include a flexible delivery catheter and that mechanical manipulation of the device using rotational motors is not required during therapy. This multi-sectored tubular array transurethral ultrasound technology has demonstrated potential for relatively fast and reasonably conformal targeting of prostate volumes suitable for the minimally invasive treatment of BPH and cancer under MR guidance, with further development warranted.


NMR in Biomedicine | 1998

Feasibility study of lactate imaging of head and neck tumors

Elfar Adalsteinsson; Daniel M. Spielman; John M. Pauly; D. J. Terris; Graham Sommer; Albert Macovski

A proton spectroscopic imaging sequence was used to investigate the feasibility of lactate imaging in head and neck tumors. The sequence employs a two‐shot lactate editing method with inversion recovery for additional lipid suppression, and a restricted field of view to suppress motion artifacts. Variations in acquisition parameters and two different receive coils were investigated on twelve patients. Elevated lactate was detected in three patients, no lactate was observed in seven patients, and two studies were inconclusive because of severe motion or inhomogeneity artifacts. Best results were obtained with an anterior/posterior neck coil at a 288 ms echo time (TE).

Collaboration


Dive into the Graham Sommer's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

William H. Nau

University of California

View shared research outputs
Top Co-Authors

Avatar

Adam M. Kinsey

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge