Graydon Ernest Beatty
St. Jude Medical
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Graydon Ernest Beatty.
Circulation | 1999
Alan H. Kadish; John A. Hauck; Brian D. Pederson; Graydon Ernest Beatty; Charles C. Gornick
BACKGROUND Endocardial mapping of sustained arrhythmias has traditionally been performed with a roving diagnostic catheter. Although this approach is adequate for many tachyarrhythmias, it has limitations. The purpose of this study was to evaluate a novel noncontact mapping system for assessing atrial tachyarrhythmias. METHODS AND RESULTS The mapping system consists of a 9F multielectrode-array balloon catheter that has 64 active electrodes and ring electrodes for emitting a locator signal. The locator signal was used to construct a 3-dimensional right atrial map; it was independently validated and was highly accurate. Virtual electrograms were calculated at 3360 endocardial sites in the right atrium. We evaluated right atrial activation by positioning the balloon catheter in the mid right atrium via a femoral venous approach. Experiments were performed on 12 normal mongrel dogs. The mean correlation coefficient between contact and virtual electrograms was 0.80+/-0.12 during sinus rhythm. Fifty episodes of atrial flutter induced in 11 animals were evaluated. In the majority of experiments, complete or almost complete reentrant circuits could be identified within the right atrium. Mean correlation coefficient between virtual and contact electrograms was 0.85+/-0.17 in atrial flutter. One hundred fifty-six episodes of pacing-induced atrial fibrillation were evaluated in 11 animals. Several distinct patterns of right atrial activation were seen, including single-activation wave fronts and multiple simultaneous-activation wave fronts. Mean correlation coefficient between virtual and contact electrograms during atrial fibrillation was 0.81+/-0.18. The accuracy of electrogram reconstruction was lower at sites >4.0 cm from the balloon center and at sites with a high spatial complexity of electrical activation. CONCLUSIONS This novel noncontact mapping system can evaluate conduction patterns during sinus rhythm, demonstrate reentry during atrial flutter, and describe right atrial activation during atrial fibrillation. The accuracy of electrogram reconstruction was good at sites <4.0 cm from the balloon center, and thus the system has the ability to perform high-resolution multisite mapping of atrial tachyarrhythmias in vivo.
Archive | 1993
Graydon Ernest Beatty; Jonathan Kagan; Jeffrey Robert Budd
Archive | 1995
Jeffrey Robert Budd; Graydon Ernest Beatty; John A. Hauck
Archive | 2000
Graydon Ernest Beatty; Jeffrey Robert Budd; John A. Hauck
Archive | 1992
Jonathan Kagan; Graydon Ernest Beatty; Jeffrey Robert Budd
Archive | 1995
Jeffrey Robert Budd; John A. Hauck; Graydon Ernest Beatty
Archive | 2004
Graydon Ernest Beatty; Jonathan Kagan; Jeffrey Robert Budd
Archive | 2000
Jeffrey Robert Budd; Graydon Ernest Beatty; John A. Hauck
Archive | 2000
Jeffrey Robert Budd; Graydon Ernest Beatty; John A. Hauck
Archive | 2007
Graydon Ernest Beatty; Jeffrey Robert Budd; John A. Hauck