Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Graydon Ernest Beatty is active.

Publication


Featured researches published by Graydon Ernest Beatty.


Circulation | 1999

Mapping of Atrial Activation With a Noncontact, Multielectrode Catheter in Dogs

Alan H. Kadish; John A. Hauck; Brian D. Pederson; Graydon Ernest Beatty; Charles C. Gornick

BACKGROUND Endocardial mapping of sustained arrhythmias has traditionally been performed with a roving diagnostic catheter. Although this approach is adequate for many tachyarrhythmias, it has limitations. The purpose of this study was to evaluate a novel noncontact mapping system for assessing atrial tachyarrhythmias. METHODS AND RESULTS The mapping system consists of a 9F multielectrode-array balloon catheter that has 64 active electrodes and ring electrodes for emitting a locator signal. The locator signal was used to construct a 3-dimensional right atrial map; it was independently validated and was highly accurate. Virtual electrograms were calculated at 3360 endocardial sites in the right atrium. We evaluated right atrial activation by positioning the balloon catheter in the mid right atrium via a femoral venous approach. Experiments were performed on 12 normal mongrel dogs. The mean correlation coefficient between contact and virtual electrograms was 0.80+/-0.12 during sinus rhythm. Fifty episodes of atrial flutter induced in 11 animals were evaluated. In the majority of experiments, complete or almost complete reentrant circuits could be identified within the right atrium. Mean correlation coefficient between virtual and contact electrograms was 0.85+/-0.17 in atrial flutter. One hundred fifty-six episodes of pacing-induced atrial fibrillation were evaluated in 11 animals. Several distinct patterns of right atrial activation were seen, including single-activation wave fronts and multiple simultaneous-activation wave fronts. Mean correlation coefficient between virtual and contact electrograms during atrial fibrillation was 0.81+/-0.18. The accuracy of electrogram reconstruction was lower at sites >4.0 cm from the balloon center and at sites with a high spatial complexity of electrical activation. CONCLUSIONS This novel noncontact mapping system can evaluate conduction patterns during sinus rhythm, demonstrate reentry during atrial flutter, and describe right atrial activation during atrial fibrillation. The accuracy of electrogram reconstruction was good at sites <4.0 cm from the balloon center, and thus the system has the ability to perform high-resolution multisite mapping of atrial tachyarrhythmias in vivo.


Archive | 1993

Endocardial mapping system

Graydon Ernest Beatty; Jonathan Kagan; Jeffrey Robert Budd


Archive | 1995

Electrophysiology mapping system

Jeffrey Robert Budd; Graydon Ernest Beatty; John A. Hauck


Archive | 2000

Method for measuring heart electrophysiology

Graydon Ernest Beatty; Jeffrey Robert Budd; John A. Hauck


Archive | 1992

Heart mapping catheter

Jonathan Kagan; Graydon Ernest Beatty; Jeffrey Robert Budd


Archive | 1995

Endocardial measurement method

Jeffrey Robert Budd; John A. Hauck; Graydon Ernest Beatty


Archive | 2004

Software for mapping potential distribution of a heart chamber

Graydon Ernest Beatty; Jonathan Kagan; Jeffrey Robert Budd


Archive | 2000

Method for creating a virtual electrogram

Jeffrey Robert Budd; Graydon Ernest Beatty; John A. Hauck


Archive | 2000

Method for orienting an electrode array

Jeffrey Robert Budd; Graydon Ernest Beatty; John A. Hauck


Archive | 2007

Electrophysiology therapy catheter

Graydon Ernest Beatty; Jeffrey Robert Budd; John A. Hauck

Collaboration


Dive into the Graydon Ernest Beatty's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge