Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Grayson W. Marshall is active.

Publication


Featured researches published by Grayson W. Marshall.


Journal of Dentistry | 1997

The dentin substrate: structure and properties related to bonding.

Grayson W. Marshall; Sally J. Marshall; J.H. Kinney; M. Balooch

OBJECTIVES Dentin is a vital, hydrated composite material with structural components and properties that vary with location. These variations are reviewed along with alterations by physiological and pathological changes that allow classification into various forms of dentin. Structural characteristics and mechanical properties are reviewed and the limitations of our understanding of structure-property relationships for normal and modified forms of dentin are discussed with respect to their impact on dentin bonding. Recent progress in methods available to study dentin and its demineralization are emphasized with their promise to increase our understanding of dentin properties and structure. DATA SOURCES Recent microstructural studies, focusing on scanning electron microscopy, atomic force microscopy and X-ray tomographic microscopy are included. A review of fundamental studies with emphasis on microstructurally sensitive methods, and prior reviews of basic mechanical properties are included with discussion of their correlation to composition and structure. STUDY SELECTION AND CONCLUSIONS Emphasis in this work was placed on the major structural components of the tissue, including the collagen based organic matrix and its mineral reinforcement, the distribution of these components and their microstructural organization as related to mechanical properties and response to demineralization. Little information is included on biochemical and developmental studies or on non-collagenous proteins and other organic components for which limited understanding is available with respect to their role in structure-property relations and influence on bonding. In spite of the fact that the complexity of dentin precluded a comprehensive review, it is clear that local structural variations influence properties and impact nearly all preventive and restorative dental treatments. Much more work is needed in order to understand differences between vital and non-vital dentin, and dentin from extracted teeth. Although our knowledge is rudimentary in certain areas, increasingly sophisticated methods of studying dentin should provide the necessary information to model structure-property relations, optimize dentin bonding, and improve many aspects of preventive and restorative dentistry.


Critical Reviews in Oral Biology & Medicine | 2003

The mechanical properties of human dentin: a critical review and re-evaluation of the dental literature.

J.H. Kinney; Sally J. Marshall; Grayson W. Marshall

The past 50 years of research on the mechanical properties of human dentin are reviewed. Since the body of work in this field is highly inconsistent, it was often necessary to re-analyze prior studies, when possible, and to re-assess them within the framework of composite mechanics and dentin structure. A critical re-evaluation of the literature indicates that the magnitudes of the elastic constants of dentin must be revised considerably upward. The Youngs and shear moduli lie between 20-25 GPa and 7-10 GPa, respectively. Viscoelastic behavior (time-dependent stress relaxation) measurably reduces these values at strain rates of physiological relevance; the reduced modulus (infinite relaxation time) is about 12 GPa. Furthermore, it appears as if the elastic properties are anisotropic (not the same in all directions); sonic methods detect hexagonal anisotropy, although its magnitude appears to be small. Strength data are re-interpreted within the framework of the Weibull distribution function. The large coefficients of variation cited in all strength studies can then be understood in terms of a distribution of flaws within the dentin specimens. The apparent size-effect in the tensile and shear strength data has its origins in this flaw distribution, and can be quantified by the Weibull analysis. Finally, the relatively few fracture mechanics and fatigue studies are discussed. Dentin has a fatigue limit. For stresses smaller than the normal stresses of mastication, approximately 30 MPa, a flaw-free dentin specimen apparently will not fail. However, a more conservative approach based on fatigue crack growth rates indicates that if there is a pre-existing flaw of sufficient size (approximately 0.3-1.0 mm), it can grow to catastrophic proportion with cyclic loading at stresses below 30 MPa.


Archives of Oral Biology | 2001

Mechanical properties of human dental enamel on the nanometre scale

Stefan Habelitz; Sally J. Marshall; Grayson W. Marshall; M. Balooch

Atomic force microscopy (AFM) combined with a nano-indentation technique was used to reveal the structure and to perform site-specific mechanical testing of the enamel of third molars. Nano-indentations (size<500 nm) were made in the cusp area to measure the mechanical properties of single enamel rods at different orientations. The influence of etching on the physical properties was studied and etching conditions that did not significantly alter the plastic-elastic response of enamel were defined. Elasticity and hardness were found to be a function of the microstructural texture. Mean Youngs moduli of 87.5 (+/-2.2) and 72.2 (+/-4.5) GPa and mean hardness of 3.9+/-0.3 and 3.3+/-0.3 GPa were measured in directions parallel and perpendicular to the enamel rods, respectively. Analysis of variance showed that the differences were significant. The observed anisotropy of enamel is related to the alignment of fibre-like apatite crystals and the composite nature of enamel rods. Mechanical properties were also studied at different locations on single enamel rods. Compared to those in the head area of the rods, Youngs moduli and hardness were lower in the tail area and in the inter-rod enamel, which can be attributed to changes in crystal orientation and the higher content of soft organic tissue in these areas.


Archives of Oral Biology | 1996

Hardness and young's modulus of human peritubular and intertubular dentine

J.H. Kinney; M. Balooch; S.J. Marshall; Grayson W. Marshall; Timothy P. Weihs

A specially modified atomic-force microscope was used to measure the hardness of fully hydrated peritubular and intertubular dentine at two locations within unerupted human third molars: within 1 mm of the dentine enamel junction and within 1 mm of the pulp. The hardness of fully hydrated peritubular dentine was independent of location, and ranged from 2.23 to 2.54 GPa. The hardness of fully hydrated intertubular dentine did depend upon location, and was significantly greater near the dentine enamel junction (values ranged from 0.49 to 0.52 GPa) than near the pulp (0.12-0.18 GPa). A Nanoindenter was used to estimate the Youngs modulus of dehydrated peritubular and intertubular dentine from the unloading portion of the load displacement curve. The modulus values averaged 29.8 GPa for the peritubular dentine (considered to be a lower limit), and ranged from 17.7 to 21.1 GPa for the intertubular dentine, with the lower values obtained for dentine near the pulp.


Journal of Biomedical Materials Research | 2001

Mechanical properties of the dentinoenamel junction: AFM studies of nanohardness, elastic modulus, and fracture

Grayson W. Marshall; M. Balooch; R. R. Gallagher; Stuart A. Gansky; Sally J. Marshall

The dentinoenamel junction (DEJ) is a complex and poorly defined structure that unites the brittle overlying enamel with the dentin that forms the bulk of the tooth. In addition, this structure appears to confer excellent toughness and crack deflecting properties to the tooth, and has drawn considerable interest as a biomimetic model of a structure uniting dissimilar materials. This work sought to characterize the nanomechanical properties in the region of the DEJ using modified AFM based nanoindentation to determine nanohardness and elastic modulus. Lines of indentations traversing the DEJ were made at 1-2 microm intervals from the dentin to enamel along three directions on polished sagittal sections from three third molars. Nanohardness and elastic modulus rose steadily across the DEJ from bulk dentin to enamel. DEJ width was estimated by local polynomial regression fits for each sample and location of the mechanical property curves for the data gradient from enamel to dentin, and gave a mean value of 11.8 microm, which did not vary significantly with intratooth location or among teeth. Nanoindentation was also used to initiate cracks in the DEJ region. In agreement with prior work, it was difficult to initiate cracks that traversed the DEJ, or to produce cracks in the dentin. The fracture toughness values for enamel of 0.6-0.9 MPa . m(1/2) were in good agreement with recent microindentation fracture results. Our results suggest that the DEJ displays a gradient in structure and that nanoindenation methods show promise for further understanding its structure and function.


Journal of Dental Research | 2002

Bonding to Er-YAG-laser-treated dentin

Laura Ceballos; Manuel Toledano; Raquel Osorio; Fr Tay; Grayson W. Marshall

Er-YAG laser irradiation has been claimed to improve the adhesive properties of dentin. We tested the hypothesis that dentin adhesion is affected by Er-YAG laser conditioning. Superficial or deep dentin from human molars was: (a) acid-etched with 35% H3PO4; (b) irradiated with an Er-YAG laser (KaVo) at 2 Hz and 180 mJ, with water-cooling; and (c) laser- and acid-etched. Single Bond (3M ESPE) and Z100 composite (3M ESPE) were bonded to the prepared surfaces. After storage, specimens were tested in shear to failure. Bonded interfaces were demineralized in EDTA and processed for transmission electron microscopy. Two-way ANOVA revealed that conditioning treatment and interaction between treatment and dentin depth significantly influenced shear bond strength results. Acid-etching alone yielded shear bond strength values that were significantly higher than those achieved with laser ablation alone, or in combination with acid-etching. The Er-YAG laser created a laser-modified layer that adversely affects adhesion to dentin, so it does not constitute an alternative bonding strategy to conventional acid etching.


Journal of Structural Biology | 2002

In situ atomic force microscopy of partially demineralized human dentin collagen fibrils

Stefan Habelitz; M. Balooch; Sally J. Marshall; Guive Balooch; Grayson W. Marshall

Dentin collagen fibrils were studied in situ by atomic force microscopy (AFM). New data on size distribution and the axial repeat distance of hydrated and dehydrated collagen type I fibrils are presented. Polished dentin disks from third molars were partially demineralized with citric acid, leaving proteins and the collagen matrix. At this stage collagen fibrils were not resolved by AFM, but after exposure to NaOCl(aq) for 100-240 s, and presumably due to the removal of noncollagenous proteins, individual collagen fibrils and the fibril network of dentin connected to the mineralized substrate were revealed. High-aspect-ratio silicon tips in tapping mode were used to image the soft fibril network. Hydrated fibrils showed three distinct groups of diameters: 100, 91, and 83 nm and a narrow distribution of the axial repeat distance at 67 nm. Dehydration resulted in a broad distribution of the fibril diameters between 75 and 105 nm and a division of the axial repeat distance into three groups at 67, 62, and 57 nm. Subfibrillar features (4 nm) were observed on hydrated and dehydrated fibrils. The gap depth between the thick and thin repeating segments of the fibrils varied from 3 to 7 nm. Phase mode revealed mineral particles on the transition from the gap to the overlap zone of the fibrils. This method appears to be a powerful tool for the analysis of fibrillar collagen structures in calcified tissues and may aid in understanding the differences in collagen affected by chemical treatments or by diseases.


Archives of Oral Biology | 1999

A micromechanics model of the elastic properties of human dentine.

J.H. Kinney; M. Balooch; Grayson W. Marshall; Sally J. Marshall

A generalized, self-consistent model of cylindrical inclusions in a homogeneous and isotropic matrix phase was used to study the effects of tubule orientation on the elastic properties of dentine. Closed-form expressions for the five independent elastic constants of dentine were derived in terms of tubule concentration, and the Youngs moduli and Poisson ratios of peri- and intertubular dentine. An atomic-force microscope indentation technique determined the Youngs moduli of the peri- and intertubular dentine as approx. 30 and 15 GPa, respectively. Over the natural variation in tubule density found in dentine, there was only a slight variation in the axial and transverse shear moduli with position in the tooth, and there was no measurable effect of tubule orientation. It was concluded that tubule orientation has no appreciable effect on the elastic behaviour of normal dentine, and that the elastic properties of healthy dentine can be modelled as an isotropic continuum with a Youngs modulus of approx. 16 GPa and a shear modulus of 6.2 GPa.


Journal of Dental Research | 1994

Sterilization of Teeth by Gamma Radiation

Joel M. White; Harold E. Goodis; Sally J. Marshall; Grayson W. Marshall

Clinical simulations and restorative materials research and development conducted in vitro require the use of large numbers of extracted teeth. The simultaneous need for infection control procedures and minimal alterations of structure and properties of the tissue prompted this study of gamma irradiation as a method to eliminate microbes associated with extracted teeth and their storage solutions. Evaluations of potential change in structure of dentin were conducted in terms of permeability, Fourier transform infrared spectroscopy (FTIR), and optical properties. The dose required for sterilization by gamma irradiation was established by means of a tooth model inoculated with Bacillus subtilis (108 organisms/mL). Sterilization occurred at a dose above 173 krad with use of a Cesium (Cs137) radiation source. Gamma irradiation did not affect permeability of crown segments of dentin. A comparative evaluation of the effects of four sterilization methods on dentin disks was based on FTIR and ultraviolet-visible-near infrared (UV/VIS/NIR) spectra before and after sterilization by (1) gamma irradiation; (2) ethylene oxide; (3) dry heat; and (4) autoclaving. No detectable changes were found with gamma irradiation, but all other methods introduced some detectable change in the spectra. This suggests that common methods of sterilization alter the structure of the dentin, but gamma irradiation shows promise as a method which both is effective and introduces no detectable changes as measured by FTIR, UV/VIS/NIR, or permeability.


Dental Materials | 2003

The influence of the dentin smear layer on adhesion: a self-etching primer vs. a total-etch system

Sofia S.A. Oliveira; Megan Pugach; Joan F. Hilton; L.G. Watanabe; Sally J. Marshall; Grayson W. Marshall

OBJECTIVE To determine the effect of dentin smear layers created by various abrasives on the adhesion of a self-etching primer (SE) and total-etch (SB) bonding systems. METHODS Polished human dentin disks were further abraded with 0.05 micro m alumina slurry, 240-, 320- or 600-grit abrasive papers, # 245 carbide, # 250.9 F diamond or # 250.9 C diamond burs. Shear bond strength (SBS) was evaluated by single-plane lap shear, after bonding with SE or SB and with a restorative composite. Smear layers were characterized by thickness, using SEM; surface roughness using AFM; and reaction to the conditioners, based on the percentage of open tubules, using SEM. RESULTS Overall, SBS was lower when SB was used than when SE was used. SBS decreased with increasing coarseness of the abrasive in the SE group. Among burs, the carbide group had the highest SBS, and 320- and 240-grit papers had SBS close to the carbide group. Surface roughness and smear layer thickness varied strongly with coarseness. After conditioning with SE primer, the tubule openness of specimens abraded by carbide bur did not differ from 240- or 320-grit paper, but did differ from the 600-grit. SIGNIFICANCE Even though affected by different surface preparation methods, SE yielded higher SBS than SB. The higher SBS and thin smear layer of the carbide bur group, suggests its use when self-etching materials are used in vivo. Overall, the 320-grit abrasive paper surface finish yielded results closer to that of the carbide bur and its use is recommended in vitro as a clinical simulator when using the SE material.

Collaboration


Dive into the Grayson W. Marshall's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. Balooch

University of California

View shared research outputs
Top Co-Authors

Avatar

J.H. Kinney

Lawrence Livermore National Laboratory

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sunita P. Ho

University of California

View shared research outputs
Top Co-Authors

Avatar

Antoni P. Tomsia

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kuniko Saeki

University of California

View shared research outputs
Top Co-Authors

Avatar

L.G. Watanabe

University of California

View shared research outputs
Top Co-Authors

Avatar

Eduardo Saiz

Imperial College London

View shared research outputs
Researchain Logo
Decentralizing Knowledge