Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Greet Beelaert is active.

Publication


Featured researches published by Greet Beelaert.


Clinical and Vaccine Immunology | 2011

Performance of a Rapid and Simple HIV Testing Algorithm in a Multicenter Phase III Microbicide Clinical Trial

Tania Crucitti; Doug Taylor; Greet Beelaert; Katrien Fransen; Lut Van Damme

ABSTRACT A multitest sequential algorithm based on rapid and simple (R/S) assays was applied for the diagnosis of HIV infection among participants in a phase 3 microbicide effectiveness trial. HIV testing was performed on finger-prick blood samples obtained from patients after their enrollment in the trial. The specimens were tested in a serial procedure using three different rapid tests (Determine HIV-1/2 [Abbott], SD Bioline HIV-1/2 3.0 [Standard Diagnostics], and Uni-Gold HIV [Trinity Biotech]). In the event of discordant results between the Determine HIV-1/2 and SD Bioline HIV-1/2 3.0 tests, the third assay (Uni-Gold HIV) determined the final outcome. When the final outcome was positive, a second specimen was collected and tested with the same algorithm, only if a positive result was obtained with this sample the participant was informed of her positive serostatus. A total of 5,734 postenrollment specimens obtained from 1,398 women were tested. Forty-six women tested positive according to the testing algorithm performed on the first collected specimen. Confirmatory testing results obtained at the ITM confirmed that 42 women were truly infected. Two of four initial false positives tested negative upon analysis of a second blood specimen. The other two tested false positive twice using specimens collected the same day. A high percentage of specimens reactive with the Determine HIV-1/2 assay was only observed at the study site in Kampala. This result did not appear to be associated with pregnancy or malaria infection. We conclude that HIV testing algorithms, including only R/S assays, are suitable for use in clinical trials, provided that adequate quality assurance procedures are in place.


Transactions of The Royal Society of Tropical Medicine and Hygiene | 2010

Evaluation of four rapid tests for diagnosis and differentiation of HIV-1 and HIV-2 infections in Guinea-Conakry, West Africa

P. Chaillet; K. Tayler-Smith; Rony Zachariah; Nanfack Duclos; Diallo Moctar; Greet Beelaert; Katrien Fransen

With both HIV-1 and HV-2 prevalent in Guinea-Conakry, accurate diagnosis and differentiation is crucial for treatment purposes. Thus, four rapid HIV tests were evaluated for their HIV-1 and HIV-2 diagnostic and discriminative capacity for use in Guinea-Conakry. These included SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), Genie II HIV1/HIV2 (Bio-Rad), First Response HIV Card Test 1-2.0 (PMC Medical) and Immunoflow HIV1-HIV2 (Core Diagnostics). Results were compared with gold standard tests (INNO-LIA HIV-I/II Score) and NEW LAV BLOT II (Bio-Rad). Four hundred and forty three sequential stored HIV-positive serum samples, of known HIV-type, were evaluated. Genie II HIV1/HIV2, Immunoflow HIV1-HIV2 and SD Bioline HIV 1/2 3.0 had 100% sensitivity (95% CI, 98.9-100%) while for First Response HIV Card Test 1-2.0 this was 99.5% (95% CI, 98.2%-99.9%). In terms of discriminatory capacity, Genie II HIV1/HIV2 identified 382/ 384(99.5%) HIV-1 samples, 49/ 52(95%) HIV-2 and 7/7(100%) HIV-positive untypable samples. Immunoflow HIV1-HIV2 identified 99% HIV-1, 67% HIV-2 and all HIV-positive untypable samples. First Response HIV Card Test 1-2.0 identified 94% HIV-1, 64% HIV-2 and 57% HIV-positive untypable samples. SD-Bioline HIV 1/2 3.0 was the worst overall performer identifying 65% HIV-1, 69% HIV-2 and all HIV-positive untypable samples. The use of SD Bioline HIV 1/2 3.0 (the current standard in Guinea-Conakry) as a discriminatory HIV test is poor and may be best replaced by Immunoflow HIV1-HIV2.


Journal of the International AIDS Society | 2017

Towards more accurate HIV testing in sub-Saharan Africa: a multi-site evaluation of HIV RDTs and risk factors for false positives

Cara S. Kosack; Anne-Laure Page; Greet Beelaert; Tumwesigye Benson; Aboubacar Savane; Anne Ng'ang'a; Bita Andre; Jean-Paul Bn Zahinda; Leslie Shanks; Katrien Fransen

Introduction: Although individual HIV rapid diagnostic tests (RDTs) show good performance in evaluations conducted by WHO, reports from several African countries highlight potentially significant performance issues. Despite widespread use of RDTs for HIV diagnosis in resource‐constrained settings, there has been no systematic, head‐to‐head evaluation of their accuracy with specimens from diverse settings across sub‐Saharan Africa. We conducted a standardized, centralized evaluation of eight HIV RDTs and two simple confirmatory assays at a WHO collaborating centre for evaluation of HIV diagnostics using specimens from six sites in five sub‐Saharan African countries.


Journal of Virological Methods | 2013

Using conventional HIV tests on oral fluid.

Katrien Fransen; T. Vermoesen; Greet Beelaert; J. Menten; V. Hutse; K. Wouters; T. Platteau; E. Florence

There is need for more evaluations of non-invasive tests in order to broaden the reach of testing programs and to perform large scale epidemiological studies. In this study, three different human immunodeficiency virus (HIV) enzyme linked immunosorbent assays (ELISAs) and one line immunoassay were evaluated to detect HIV antibodies in oral fluid samples. Specimens were collected, after informed consent was obtained, with the Oracol (MMD, Worcester, England) device. A total IgG quantitation test was performed to demonstrate the quality of the sample. Assessment of a modified protocol of the Vironostika HIV Ag/Ab, Enzygnost Anti-HIV 1/2 Plus Genscreen HIV-1/2 Version 2 and a line immune confirmatory assay the INNO-LIA HIV I/II score was done, using oral fluid specimens of 325 HIV positive and negative individuals. For the ELISAs, the addition of an extra internal oral fluid control was evaluated as well as different cut-offs, time between sampling and testing and the effect of drinking water just before sampling. Finally, the confirmatory test and some testing algorithms and combination of tests were discussed. The results obtained from the oral fluid specimens were compared with the gold standard on paired serum specimens. Firstly, there was no significant difference observed between the use of the kit controls and the oral fluid controls. New protocols and calculation of cut-offs were defined for two of the three ELISAs. High sensitivities and specificities were obtained with all three ELISAs without any statistical difference between the three tests. Secondly, no statistically significant difference was observed when samples were stored for different time periods between sampling and testing, meaning that a period of seven days at room temperature before testing is still acceptable. Thirdly, drinking water before sample collection did not interfere with the testing, although lower optical densities were observed. None of the positive samples were missed. In addition, the line immunoassay INNO-LIA HIV I/II score test is a promising test for confirmation of reactive oral fluid specimen, but more samples need to be validated in order to adapt the interpretation rules specifically for oral fluid specimens. Different choices/algorithms adapted for the purpose of testing can be proposed. In conclusion, it can be said that the commercial ELISAs with adapted protocol and cut-off values are suitable tools for making HIV test performance accessible to people. With this non-invasive sampling method, more eligible individuals can and will be selected for further HIV test on blood.


PLOS ONE | 2010

Obtaining Valid Laboratory Data in Clinical Trials Conducted in Resource Diverse Settings: Lessons Learned from a Microbicide Phase III Clinical Trial

Tania Crucitti; Katrien Fransen; Rashika Maharaj; Tom Tenywa; Marguerite Massinga Loembé; Kailapuri Gangatharan Murugavel; Kevin Mendonca; Saïd Abdellati; Greet Beelaert; Lut Van Damme

Background Over the last decade several phase III microbicides trials have been conducted in developing countries. However, laboratories in resource constrained settings do not always have the experience, infrastructure, and the capacity to deliver laboratory data meeting the high standards of clinical trials. This paper describes the design and outcomes of a laboratory quality assurance program which was implemented during a phase III clinical trial evaluating the efficacy of the candidate microbicide Cellulose Sulfate 6% (CS) [1]. Methodology In order to assess the effectiveness of CS for HIV and STI prevention, a phase III clinical trial was conducted in 5 sites: 3 in Africa and 2 in India. The trial sponsor identified an International Central Reference Laboratory (ICRL), responsible for the design and management of a quality assurance program, which would guarantee the reliability of laboratory data. The ICRL provided advice on the tests, assessed local laboratories, organized trainings, conducted supervision visits, performed re-tests, and prepared control panels. Local laboratories were provided with control panels for HIV rapid tests and Chlamydia trachomatis/Neisseria gonorrhoeae (CT/NG) amplification technique. Aliquots from respective control panels were tested by local laboratories and were compared with results obtained at the ICRL. Results Overall, good results were observed. However, discordances between the ICRL and site laboratories were identified for HIV and CT/NG results. One particular site experienced difficulties with HIV rapid testing shortly after study initiation. At all sites, DNA contamination was identified as a cause of invalid CT/NG results. Both problems were timely detected and solved. Through immediate feedback, guidance and repeated training of laboratory staff, additional inaccuracies were prevented. Conclusions Quality control guidelines when applied in field laboratories ensured the reliability and validity of final study data. It is essential that sponsors provide adequate resources for implementation of such comprehensive technical assessment and monitoring systems. Trial Registration ClinicalTrials.gov NCT00153777 and Current Controlled Trials ISRCTN95638385


Journal of Virological Methods | 2014

Discriminatory capacity between HIV-1 and HIV-2 of the new rapid confirmation assay Geenius

Natacha Herssens; Greet Beelaert; Katrien Fransen

The currently used HIV confirmatory assays, Western blot and line immunoassay, are costly, complex and time-consuming. There is a need for cheaper, simpler and faster assays for use in high- and low-resource settings. Furthermore, it is necessary to differentiate between HIV-1 and HIV-2 infection due to differences in disease progression, monitoring and treatment options. Because the new Geenius HIV 1/2 Confirmatory Assay (Bio-Rad) has a European Community (CE) label, this study focused on its differentiation capacity using serum/plasma specimens from established HIV-1, HIV-2 and HIV untypable infections from the AIDS Reference Laboratory (ARL) of the Institute of Tropical Medicine (ITM) in Belgium. The results were compared with ARLs standard algorithm for diagnosis of HIV-infection and the new interpretation criteria for discrimination of the INNO-LIA HIVI/II Score, Fujirebio, Ghent, Belgium (LIA). The study showed a performance comparable to that of the reference LIA, with an overall sensitivity of 99.3% and specificity of 98%. Differentiation capacity was much better for the Geenius assay, with 93.8% of samples identified correctly as HIV-1 or HIV-2. When the new interpretation criteria for the LIA were used, the differentiation capacity of LIA increased to 98.5%. The results show that the Geenius assay is a reliable and fast alternative for the confirmation and differentiation of HIV-1 and HIV-2 infection in resource-rich and poor settings.


Malaria Journal | 2012

Assessment of desiccants and their instructions for use in rapid diagnostic tests

Barbara Barbé; Philippe Gillet; Greet Beelaert; Katrien Fransen; Jan Jacobs

Malaria rapid diagnostic tests (RDTs) are protected from humidity-caused degradation by a desiccant added to the device packaging. The present study assessed malaria RDT products for the availability, type and design of desiccants and their information supplied in the instructions for use (IFU). Criteria were based on recommendations of the World Health Organization (WHO), the European Community (CE) and own observations. Silica gel sachets were defined as self-indicating (all beads coated with a humidity indicator that changes colour upon saturation), partial-indicating (part of beads coated) and non-indicating (none of the beads coated). Indicating silica gel sachets were individually assessed for humidity saturation and (in case of partial-indicating silica gels) for the presence of indicating beads. Fifty malaria RDT products from 25 manufacturers were assessed, 14 (28%) products were listed by the “Global Fund Quality Assurance Policy” and 31 (62%) were CE-marked. All but one product contained a desiccant, mostly (47/50, 94%) silica gel. Twenty (40%) RDT products (one with no desiccant and 19 with non-indicating desiccant) did not meet the WHO guidelines recommending indicating desiccant. All RDT products with self- or partial-indicating silica gel (n = 22 and 8 respectively) contained the toxic cobalt dichloride as humidity indicator. Colour change indicating humidity saturation was observed for 8/16 RDT products, at a median incidence of 0.8% (range 0.05%-4.6%) of sachets inspected. In all RDTs with partial-indicating silica gel, sachets with no colour indicating beads were found (median proportion 13.5% (0.6% - 17.8%) per product) and additional light was needed to assess the humidity colour. Less than half (14/30, 47%) IFUs of RDT products with indicating desiccants mentioned to check the humidity saturation before using the test. Information on properties, safety hazards and disposal of the desiccant was not included in any of the IFUs. There were no differences between Global Fund-listed and CE marked RDT products compared to those which were not. Similar findings were noted for a panel of 11 HIV RDTs that was assessed with the same checklist as the malaria RDTs. RDTs showed shortcomings in desiccant type and information supplied in the IFU.BackgroundMalaria rapid diagnostic tests (RDTs) are protected from humidity-caused degradation by a desiccant added to the device packaging. The present study assessed malaria RDT products for the availability, type and design of desiccants and their information supplied in the instructions for use (IFU).MethodsCriteria were based on recommendations of the World Health Organization (WHO), the European Community (CE) and own observations. Silica gel sachets were defined as self-indicating (all beads coated with a humidity indicator that changes colour upon saturation), partial-indicating (part of beads coated) and non-indicating (none of the beads coated). Indicating silica gel sachets were individually assessed for humidity saturation and (in case of partial-indicating silica gels) for the presence of indicating beads.ResultsFifty malaria RDT products from 25 manufacturers were assessed, 14 (28%) products were listed by the “Global Fund Quality Assurance Policy” and 31 (62%) were CE-marked. All but one product contained a desiccant, mostly (47/50, 94%) silica gel. Twenty (40%) RDT products (one with no desiccant and 19 with non-indicating desiccant) did not meet the WHO guidelines recommending indicating desiccant. All RDT products with self- or partial-indicating silica gel (n = 22 and 8 respectively) contained the toxic cobalt dichloride as humidity indicator. Colour change indicating humidity saturation was observed for 8/16 RDT products, at a median incidence of 0.8% (range 0.05%-4.6%) of sachets inspected. In all RDTs with partial-indicating silica gel, sachets with no colour indicating beads were found (median proportion 13.5% (0.6% - 17.8%) per product) and additional light was needed to assess the humidity colour. Less than half (14/30, 47%) IFUs of RDT products with indicating desiccants mentioned to check the humidity saturation before using the test. Information on properties, safety hazards and disposal of the desiccant was not included in any of the IFUs. There were no differences between Global Fund-listed and CE marked RDT products compared to those which were not. Similar findings were noted for a panel of 11 HIV RDTs that was assessed with the same checklist as the malaria RDTs.ConclusionRDTs showed shortcomings in desiccant type and information supplied in the IFU.


International Journal of Std & Aids | 2014

Use of rapid HIV testing in a low threshold centre in Antwerp, Belgium, 2007–2012

Kristien Wouters; Katrien Fransen; Greet Beelaert; Chris Kenyon; Tom Platteau; Chris Van Ghyseghem; Ilse Collier; Jozefien Buyze; Eric Florence

The Antwerp Helpcenter is a low threshold screening centre for HIV and STI testing focused on high-risk groups. The aim of this work is to describe our experience with the use of rapid HIV tests including the analysis of the characteristics of new cases of HIV infection. We performed a retrospective analysis of all rapid tests routinely performed at the Helpcenter in the period June 2007 to December 2012. The Determine®HIV-1/2 (3rd generation) was used until May 2009 and thereafter the Determine Combo®HIV-1/2 Ag/Ab (Alere) test (4th generation) on venous blood. All reactive tests were confirmed using a standard confirmation algorithm with ELISAs and a confirmation test (INNO-LIA HIVI/II Score®). In all, 5025 rapid tests were performed on blood specimens of 3881 clients including 1173 men having sex with men and 454 migrants from sub-Sahara Africa. The overall prevalence of HIV infection was 1.5% and higher among the risk groups: 4.0% of men having sex with men and 2.2% of migrants from sub-Sahara Africa. The availability of a rapid test was an important reason to present at the Helpcenter. The rapid test was successfully introduced into an outpatient testing centre. Client satisfaction with RT was high and most clients were successfully linked to care.


Journal of Clinical Microbiology | 2017

Designing HIV Testing Algorithms Based on 2015 WHO Guidelines Using Data from Six Sites in sub-Saharan Africa

Cara S. Kosack; Leslie Shanks; Greet Beelaert; Tumwesigye Benson; Aboubacar Savane; Anne Ng'ang'a; André Bita; Jean-Paul Bn Zahinda; Katrien Fransen; Anne-Laure Page

ABSTRACT Our objective was to evaluate the performance of HIV testing algorithms based on WHO recommendations, using data from specimens collected at six HIV testing and counseling sites in sub-Saharan Africa (Conakry, Guinea; Kitgum and Arua, Uganda; Homa Bay, Kenya; Douala, Cameroon; Baraka, Democratic Republic of Congo). A total of 2,780 samples, including 1,306 HIV-positive samples, were included in the analysis. HIV testing algorithms were designed using Determine as a first test. Second and third rapid diagnostic tests (RDTs) were selected based on site-specific performance, adhering where possible to the WHO-recommended minimum requirements of ≥99% sensitivity and specificity. The threshold for specificity was reduced to 98% or 96% if necessary. We also simulated algorithms consisting of one RDT followed by a simple confirmatory assay. The positive predictive values (PPV) of the simulated algorithms ranged from 75.8% to 100% using strategies recommended for high-prevalence settings, 98.7% to 100% using strategies recommended for low-prevalence settings, and 98.1% to 100% using a rapid test followed by a simple confirmatory assay. Although we were able to design algorithms that met the recommended PPV of ≥99% in five of six sites using the applicable high-prevalence strategy, options were often very limited due to suboptimal performance of individual RDTs and to shared falsely reactive results. These results underscore the impact of the sequence of HIV tests and of shared false-reactivity data on algorithm performance. Where it is not possible to identify tests that meet WHO-recommended specifications, the low-prevalence strategy may be more suitable.


Sexually Transmitted Infections | 2013

P5.024 Use of Rapid HIV Test in Low Threshold Centre in Antwerp, Belgium During 2007–2012

Kristien Wouters; Katrien Fransen; Greet Beelaert; Chris Kenyon; C Van Ghyseghem; I Collier; Eric Florence

Introduction Helpcenter (HC) is a low threshold centre for HIV and STI testing and dedicated to high risk groups: men having sex with men (MSM) and migrants from high endemic regions. Rapid HIV tests (RT) are used at HC for HIV screening since June 2007. The aim of this work is to describe our experience with this testing strategy. Methods retrospective analyse of all RT routinely performed at HC. Tests are performed on plasma using the Determine Combo®HIV-1/2 Ag/Ab (Alere) test (4th generation). Determine®HIV-1/2 (3th generation) has been used until May 2009. All reactive tests were confirmed using INNO-LIA HIVI/II Score®. A validation study was performed on 310 samples at the beginning of the project Results up to December 2012, 5053 RT have been performed in 3884 persons including 1207 MSM and 994 migrants. The mean age was 33 years. 79 tests were reactive, 4968 negative and six not interpretable, two at the beginning of the project (learning curve) and four due to inappropriate light in the testing room and uncontrolled room temperature. Nine reactive tests were not confirmed with antibody or antigen tests (false-positive rate: 11.3%). No false-negative results have been observed during the validation study. The prevalence of HIV was high among the risk groups: 2.9% of MSM and 3% of migrants tested were found hiv-positive. The availability of RT was an important reason to consult at HC, 66% of the respondents highlight it as motivation to consult at HC. RT is offered to each person consulting at HC, 90% of them accepted to undergo a RT as screening for HIV. Conclusion the RT is well accepted in a dedicated testing centre. The overall prevalence of HIV infection was 1.8%, nearly double in the target groups. Data on linkage to care will be presented.

Collaboration


Dive into the Greet Beelaert's collaboration.

Top Co-Authors

Avatar

Katrien Fransen

Institute of Tropical Medicine Antwerp

View shared research outputs
Top Co-Authors

Avatar

Anne-Laure Page

Médecins Sans Frontières

View shared research outputs
Top Co-Authors

Avatar

Cara S. Kosack

Médecins Sans Frontières

View shared research outputs
Top Co-Authors

Avatar

Leslie Shanks

Médecins Sans Frontières

View shared research outputs
Top Co-Authors

Avatar

Chris Kenyon

Institute of Tropical Medicine Antwerp

View shared research outputs
Top Co-Authors

Avatar

Eric Florence

Institute of Tropical Medicine Antwerp

View shared research outputs
Top Co-Authors

Avatar

Kristien Wouters

Institute of Tropical Medicine Antwerp

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Tania Crucitti

Institute of Tropical Medicine Antwerp

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge