Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Gregory P. Fontana is active.

Publication


Featured researches published by Gregory P. Fontana.


The New England Journal of Medicine | 2010

Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery

Martin B. Leon; Craig R. Smith; Michael J. Mack; D. Craig Miller; Jeffrey W. Moses; Lars G. Svensson; E. Murat Tuzcu; John G. Webb; Gregory P. Fontana; Raj Makkar; David L. Brown; Peter C. Block; Robert A. Guyton; Augusto D. Pichard; Joseph E. Bavaria; Howard C. Herrmann; Pamela S. Douglas; John L. Petersen; Jodi J. Akin; William N. Anderson; Duolao Wang; Stuart J. Pocock

BACKGROUND Many patients with severe aortic stenosis and coexisting conditions are not candidates for surgical replacement of the aortic valve. Recently, transcatheter aortic-valve implantation (TAVI) has been suggested as a less invasive treatment for high-risk patients with aortic stenosis. METHODS We randomly assigned patients with severe aortic stenosis, whom surgeons considered not to be suitable candidates for surgery, to standard therapy (including balloon aortic valvuloplasty) or transfemoral transcatheter implantation of a balloon-expandable bovine pericardial valve. The primary end point was the rate of death from any cause. RESULTS A total of 358 patients with aortic stenosis who were not considered to be suitable candidates for surgery underwent randomization at 21 centers (17 in the United States). At 1 year, the rate of death from any cause (Kaplan–Meier analysis) was 30.7% with TAVI, as compared with 50.7% with standard therapy (hazard ratio with TAVI, 0.55; 95% confidence interval [CI], 0.40 to 0.74; P<0.001). The rate of the composite end point of death from any cause or repeat hospitalization was 42.5% with TAVI as compared with 71.6% with standard therapy (hazard ratio, 0.46; 95% CI, 0.35 to 0.59; P<0.001). Among survivors at 1 year, the rate of cardiac symptoms (New York Heart Association class III or IV) was lower among patients who had undergone TAVI than among those who had received standard therapy (25.2% vs. 58.0%, P<0.001). At 30 days, TAVI, as compared with standard therapy, was associated with a higher incidence of major strokes (5.0% vs. 1.1%, P=0.06) and major vascular complications (16.2% vs. 1.1%, P<0.001). In the year after TAVI, there was no deterioration in the functioning of the bioprosthetic valve, as assessed by evidence of stenosis or regurgitation on an echocardiogram. CONCLUSIONS In patients with severe aortic stenosis who were not suitable candidates for surgery, TAVI, as compared with standard therapy, significantly reduced the rates of death from any cause, the composite end point of death from any cause or repeat hospitalization, and cardiac symptoms, despite the higher incidence of major strokes and major vascular events. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).


The New England Journal of Medicine | 2011

Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients

Craig R. Smith; Martin B. Leon; Michael J. Mack; D. Craig Miller; Jeffrey W. Moses; Lars G. Svensson; E. Murat Tuzcu; John G. Webb; Gregory P. Fontana; Raj Makkar; Mathew R. Williams; Todd M. Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H. Thourani; Paul J. Corso; Augusto D. Pichard; Joseph E. Bavaria; Howard C. Herrmann; Jodi J. Akin; William N. Anderson; Duolao Wang; Stuart J. Pocock

BACKGROUND The use of transcatheter aortic-valve replacement has been shown to reduce mortality among high-risk patients with aortic stenosis who are not candidates for surgical replacement. However, the two procedures have not been compared in a randomized trial involving high-risk patients who are still candidates for surgical replacement. METHODS At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either transcatheter aortic-valve replacement with a balloon-expandable bovine pericardial valve (either a transfemoral or a transapical approach) or surgical replacement. The primary end point was death from any cause at 1 year. The primary hypothesis was that transcatheter replacement is not inferior to surgical replacement. RESULTS The rates of death from any cause were 3.4% in the transcatheter group and 6.5% in the surgical group at 30 days (P=0.07) and 24.2% and 26.8%, respectively, at 1 year (P=0.44), a reduction of 2.6 percentage points in the transcatheter group (upper limit of the 95% confidence interval, 3.0 percentage points; predefined margin, 7.5 percentage points; P=0.001 for noninferiority). The rates of major stroke were 3.8% in the transcatheter group and 2.1% in the surgical group at 30 days (P=0.20) and 5.1% and 2.4%, respectively, at 1 year (P=0.07). At 30 days, major vascular complications were significantly more frequent with transcatheter replacement (11.0% vs. 3.2%, P<0.001); adverse events that were more frequent after surgical replacement included major bleeding (9.3% vs. 19.5%, P<0.001) and new-onset atrial fibrillation (8.6% vs. 16.0%, P=0.006). More patients undergoing transcatheter replacement had an improvement in symptoms at 30 days, but by 1 year, there was not a significant between-group difference. CONCLUSIONS In high-risk patients with severe aortic stenosis, transcatheter and surgical procedures for aortic-valve replacement were associated with similar rates of survival at 1 year, although there were important differences in periprocedural risks. (Funded by Edwards Lifesciences; Clinical Trials.gov number, NCT00530894.).


The New England Journal of Medicine | 2012

Two-year outcomes after transcatheter or surgical aortic-valve replacement.

Susheel Kodali; Mathew R. Williams; Craig R. Smith; Lars G. Svensson; John G. Webb; Raj Makkar; Gregory P. Fontana; Todd M. Dewey; Vinod H. Thourani; Augusto D. Pichard; Michael P. Fischbein; Wilson Y. Szeto; Scott Lim; Kevin L. Greason; Paul S. Teirstein; S. Chris Malaisrie; Pamela S. Douglas; Rebecca T. Hahn; Brian Whisenant; Alan Zajarias; Duolao Wang; Jodi J. Akin; William N. Anderson; Martin B. Leon; Trial Investigators

BACKGROUND The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that among high-risk patients with aortic stenosis, the 1-year survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical replacement. However, longer-term follow-up is necessary to determine whether TAVR has prolonged benefits. METHODS At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either surgical aortic-valve replacement or TAVR. All patients were followed for at least 2 years, with assessment of clinical outcomes and echocardiographic evaluation. RESULTS The rates of death from any cause were similar in the TAVR and surgery groups (hazard ratio with TAVR, 0.90; 95% confidence interval [CI], 0.71 to 1.15; P=0.41) and at 2 years (Kaplan-Meier analysis) were 33.9% in the TAVR group and 35.0% in the surgery group (P=0.78). The frequency of all strokes during follow-up did not differ significantly between the two groups (hazard ratio, 1.22; 95% CI, 0.67 to 2.23; P=0.52). At 30 days, strokes were more frequent with TAVR than with surgical replacement (4.6% vs. 2.4%, P=0.12); subsequently, there were 8 additional strokes in the TAVR group and 12 in the surgery group. Improvement in valve areas was similar with TAVR and surgical replacement and was maintained for 2 years. Paravalvular regurgitation was more frequent after TAVR (P<0.001), and even mild paravalvular regurgitation was associated with increased late mortality (P<0.001). CONCLUSIONS A 2-year follow-up of patients in the PARTNER trial supports TAVR as an alternative to surgery in high-risk patients. The two treatments were similar with respect to mortality, reduction in symptoms, and improved valve hemodynamics, but paravalvular regurgitation was more frequent after TAVR and was associated with increased late mortality. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).


The New England Journal of Medicine | 2012

Transcatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis

Raj Makkar; Gregory P. Fontana; Hasan Jilaihawi; Samir Kapadia; Augusto D. Pichard; Pamela S. Douglas; Vinod H. Thourani; Vasilis Babaliaros; John G. Webb; Howard C. Herrmann; Joseph E. Bavaria; Susheel Kodali; David L. Brown; Bruce Bowers; Todd M. Dewey; Lars G. Svensson; Murat Tuzcu; Jeffrey W. Moses; Matthew R. Williams; Robert J. Siegel; Jodi J. Akin; William N. Anderson; Stuart J. Pocock; Craig R. Smith; Martin B. Leon

BACKGROUND Transcatheter aortic-valve replacement (TAVR) is the recommended therapy for patients with severe aortic stenosis who are not suitable candidates for surgery. The outcomes beyond 1 year in such patients are not known. METHODS We randomly assigned patients to transfemoral TAVR or to standard therapy (which often included balloon aortic valvuloplasty). Data on 2-year outcomes were analyzed. RESULTS A total of 358 patients underwent randomization at 21 centers. The rates of death at 2 years were 43.3% in the TAVR group and 68.0% in the standard-therapy group (P<0.001), and the corresponding rates of cardiac death were 31.0% and 62.4% (P<0.001). The survival advantage associated with TAVR that was seen at 1 year remained significant among patients who survived beyond the first year (hazard ratio, 0.58; 95% confidence interval [CI], 0.36 to 0.92; P=0.02 with the use of the log-rank test). The rate of stroke was higher after TAVR than with standard therapy (13.8% vs. 5.5%, P=0.01), owing, in the first 30 days, to the occurrence of more ischemic events in the TAVR group (6.7% vs. 1.7%, P=0.02) and, beyond 30 days, to the occurrence of more hemorrhagic strokes in the TAVR group (2.2% vs. 0.6%, P=0.16). At 2 years, the rate of rehospitalization was 35.0% in the TAVR group and 72.5% in the standard-therapy group (P<0.001). TAVR, as compared with standard therapy, was also associated with improved functional status (P<0.001). The data suggest that the mortality benefit after TAVR may be limited to patients who do not have extensive coexisting conditions. Echocardiographic analysis showed a sustained increase in aortic-valve area and a decrease in aortic-valve gradient, with no worsening of paravalvular aortic regurgitation. CONCLUSIONS Among appropriately selected patients with severe aortic stenosis who were not suitable candidates for surgery, TAVR reduced the rates of death and hospitalization, with a decrease in symptoms and an improvement in valve hemodynamics that were sustained at 2 years of follow-up. The presence of extensive coexisting conditions may attenuate the survival benefit of TAVR. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).


The Lancet | 2015

5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial

Michael J. Mack; Martin B. Leon; Craig R. Smith; D. Craig Miller; Jeffrey W. Moses; E. Murat Tuzcu; John G. Webb; Pamela S. Douglas; William N. Anderson; Eugene H. Blackstone; Susheel Kodali; Raj Makkar; Gregory P. Fontana; Samir Kapadia; Joseph E. Bavaria; Rebecca T. Hahn; Vinod H. Thourani; Vasilis Babaliaros; Augusto D. Pichard; Howard C. Herrmann; David L. Brown; Mathew R. Williams; Michael J. Davidson; Lars G. Svensson; Jodi J. Akin

BACKGROUND The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that mortality at 1 year, 2 years, and 3 years is much the same with transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) for high-risk patients with aortic stenosis. We report here the 5-year outcomes. METHODS We did this randomised controlled trial at 25 hospitals, in Canada (two), Germany (one), and the USA (23). We used a computer-generated randomisation sequence to randomly assign high-risk patients with severe aortic stenosis to either SAVR or TAVR with a balloon-expandable bovine pericardial tissue valve by either a transfemoral or transapical approach. Patients and their treating physicians were not masked to treatment allocation. The primary outcome of the trial was all-cause mortality in the intention-to-treat population at 1 year, we present here predefined outcomes at 5 years. The study is registered with ClinicalTrials.gov, number NCT00530894. FINDINGS We screened 3105 patients, of whom 699 were enrolled (348 assigned to TAVR, 351 assigned to SAVR). Overall mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 11·7%. At 5 years, risk of death was 67·8% in the TAVR group compared with 62·4% in the SAVR group (hazard ratio 1·04, 95% CI 0·86-1·24; p=0·76). We recorded no structural valve deterioration requiring surgical valve replacement in either group. Moderate or severe aortic regurgitation occurred in 40 (14%) of 280 patients in the TAVR group and two (1%) of 228 in the SAVR group (p<0·0001), and was associated with increased 5-year risk of mortality in the TAVR group (72·4% for moderate or severe aortic regurgitation vs 56·6% for those with mild aortic regurgitation or less; p=0·003). INTERPRETATION Our findings show that TAVR as an alternative to surgery for patients with high surgical risk results in similar clinical outcomes. FUNDING Edwards Lifesciences.


The New England Journal of Medicine | 2015

Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves

Raj Makkar; Gregory P. Fontana; Lars Søndergaard

BACKGROUND A finding of reduced aortic-valve leaflet motion was noted on computed tomography (CT) in a patient who had a stroke after transcatheter aortic-valve replacement (TAVR) during an ongoing clinical trial. This finding raised a concern about possible subclinical leaflet thrombosis and prompted further investigation. METHODS We analyzed data obtained from 55 patients in a clinical trial of TAVR and from two single-center registries that included 132 patients who were undergoing either TAVR or surgical aortic-valve bioprosthesis implantation. We obtained four-dimensional, volume-rendered CT scans along with data on anticoagulation and clinical outcomes (including strokes and transient ischemic attacks [TIAs]). RESULTS Reduced leaflet motion was noted on CT in 22 of 55 patients (40%) in the clinical trial and in 17 of 132 patients (13%) in the two registries. Reduced leaflet motion was detected among patients with multiple bioprosthesis types, including transcatheter and surgical bioprostheses. Therapeutic anticoagulation with warfarin, as compared with dual antiplatelet therapy, was associated with a decreased incidence of reduced leaflet motion (0% and 55%, respectively, P=0.01 in the clinical trial; and 0% and 29%, respectively, P=0.04 in the pooled registries). In patients who were reevaluated with follow-up CT, restoration of leaflet motion was noted in all 11 patients who were receiving anticoagulation and in 1 of 10 patients who were not receiving anticoagulation (P<0.001). There was no significant difference in the incidence of stroke or TIA between patients with reduced leaflet motion and those with normal leaflet motion in the clinical trial (2 of 22 patients and 0 of 33 patients, respectively; P=0.16), although in the pooled registries, a significant difference was detected (3 of 17 patients and 1 of 115 patients, respectively; P=0.007). CONCLUSIONS Reduced aortic-valve leaflet motion was shown in patients with bioprosthetic aortic valves. The condition resolved with therapeutic anticoagulation. The effect of this finding on clinical outcomes including stroke needs further investigation. (Funded by St. Jude Medical and Cedars-Sinai Heart Institute; Portico-IDE ClinicalTrials.gov number, NCT02000115; SAVORY registry, NCT02426307; and RESOLVE registry, NCT02318342.).


Journal of the American College of Cardiology | 2012

Cross-Sectional Computed Tomographic Assessment Improves Accuracy of Aortic Annular Sizing for Transcatheter Aortic Valve Replacement and Reduces the Incidence of Paravalvular Aortic Regurgitation

Hasan Jilaihawi; Mohammad Kashif; Gregory P. Fontana; Azusa Furugen; Takahiro Shiota; Gerald Friede; Rakhee Makhija; Niraj Doctor; Martin B. Leon; Raj Makkar

OBJECTIVES In an effort to define the gold standard for annular sizing for transcatheter aortic valve replacement (TAVR), we sought to critically analyze and compare the predictive value of multiple measures of the aortic annulus for post-TAVR paravalvular (PV) regurgitation and then assess the impact of a novel cross-sectional computed tomographic (CT) approach to annular sizing. BACKGROUND Recent studies have shown clear discrepancies between conventional 2-dimensional (2D) echocardiographic and CT measurements. In terms of aortic annular measurement for TAVR, such findings have lacked the outcome analysis required to inform clinical practice. METHODS The discriminatory value of multiple CT annular measures for post-TAVR PV aortic regurgitation was compared with 2D echocardiographic measures. TAVR outcomes with device selection according to aortic annular sizing using a traditional 2D transesophageal echocardiography-guided or a novel CT-guided approach were also studied. RESULTS In receiver-operating characteristic models, cross-sectional CT parameters had the highest discriminatory value for post-TAVR PV regurgitation: This was with the area under the curve for [maximal cross-sectional diameter minus prosthesis size] of 0.82 (95% confidence interval: 0.69 to 0.94; p < 0.001) and that for [circumference-derived cross-sectional diameter minus prosthesis size] of 0.81 (95% confidence interval: 0.7 to 0.94; p < 0.001). In contrast, traditional echocardiographic measures were nondiscriminatory in relation to post-TAVR PV aortic regurgitation. The prospective application of a CT-guided annular sizing approach resulted in less PV aortic regurgitation of grade worse than mild after TAVR (7.5% vs. 21.9%; p = 0.045). CONCLUSIONS Our data lend strong support to 3-dimensional cross-sectional measures, using CT as the new gold standard for aortic annular evaluation for TAVR with the Edwards SAPIEN device.


The Lancet | 2015

5-year outcomes of transcatheter aortic valve replacement compared with standard treatment for patients with inoperable aortic stenosis (PARTNER 1): a randomised controlled trial.

Samir Kapadia; Martin B. Leon; Raj Makkar; E. Murat Tuzcu; Lars G. Svensson; Susheel Kodali; John G. Webb; Michael J. Mack; Pamela S. Douglas; Vinod H. Thourani; Vasilis Babaliaros; Howard C. Herrmann; Wilson Y. Szeto; Augusto D. Pichard; Mathew R. Williams; Gregory P. Fontana; D. Craig Miller; William N. Anderson; Craig R. Smith; Jodi J. Akin; Michael J. Davidson

BACKGROUND Based on the early results of the Placement of Aortic Transcatheter Valves (PARTNER) trial, transcatheter aortic valve replacement (TAVR) is an accepted treatment for patients with severe aortic stenosis who are not suitable for surgery. However, little information is available about the late clinical outcomes in such patients. METHODS We did this randomised controlled trial at 21 experienced valve centres in Canada, Germany, and the USA. We enrolled patients with severe symptomatic inoperable aortic stenosis and randomly assigned (1:1) them to transfemoral TAVR or to standard treatment, which often included balloon aortic valvuloplasty. Patients and their treating physicians were not masked to treatment allocation. The randomisation was done centrally, and sites learned of the assignment only after a patient had been screened, consented, and entered into the database. The primary outcome of the trial was all-cause mortality at 1 year in the intention-to-treat population, here we present the prespecified findings after 5 years. This study is registered with ClinicalTrials.gov, number NCT00530894. FINDINGS We screened 3015 patients, of whom 358 were enrolled (mean age 83 years, Society of Thoracic Surgeons Predicted Risk of Mortality 11·7%, 54% female). 179 were assigned to TAVR treatment and 179 were assigned to standard treatment. 20 patients crossed over from the standard treatment group and ten withdrew from study, leaving only six patients at 5 years, of whom five had aortic valve replacement treatment outside of the study. The risk of all-cause mortality at 5 years was 71·8% in the TAVR group versus 93·6% in the standard treatment group (hazard ratio 0·50, 95% CI 0·39-0·65; p<0·0001). At 5 years, 42 (86%) of 49 survivors in the TAVR group had New York Heart Association class 1 or 2 symptoms compared with three (60%) of five in the standard treatment group. Echocardiography after TAVR showed durable haemodynamic benefit (aortic valve area 1·52 cm(2) at 5 years, mean gradient 10·6 mm Hg at 5 years), with no evidence of structural valve deterioration. INTERPRETATION TAVR is more beneficial than standard treatment for treatment of inoperable aortic stenosis. TAVR should be strongly considered for patients who are not surgical candidates for aortic valve replacement to improve their survival and functional status. Appropriate selection of patients will help to maximise the benefit of TAVR and reduce mortality from severe comorbidities. FUNDING Edwards Lifesciences.


Jacc-cardiovascular Interventions | 2009

A meta-analysis of 3,773 patients treated with percutaneous coronary intervention or surgery for unprotected left main coronary artery stenosis.

Hursh Naik; Anthony J. White; Tarun Chakravarty; James S. Forrester; Gregory P. Fontana; Saibal Kar; Prediman K. Shah; Robert E. Weiss; Raj Makkar

OBJECTIVES This study sought to understand the total weight of evidence regarding outcomes in coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) in unprotected left main coronary artery (ULMCA) stenosis. BACKGROUND Following a diagnosis of significant ULMCA stenosis in an individual that is a candidate for surgery, CABG is recommended by the American College of Cardiology/American Heart Association guidelines, whereas PCI is not recommended (Class III). METHODS Databases were searched for clinical studies that reported outcomes after PCI and CABG for the treatment of ULMCA stenosis. Ten studies were identified that included a total of 3,773 patients. RESULTS Meta-analysis showed that death, myocardial infarction, and stroke (major adverse cardiovascular or cerebrovascular events) were similar in the PCI- and CABG-treated patients at 1 year (odds ratio [OR]: 0.84 [95% confidence interval: 0.57 to 1.22]), 2 years (OR: 1.25 [95% CI: 0.81 to 1.94]), and 3 years (OR: 1.16 [95% CI: 0.68 to 1.98]). Target vessel revascularization was significantly higher in the PCI group at 1 year (OR: 4.36 [95% CI: 2.60 to 7.32]), 2 years (OR: 4.20 [95% CI: 2.21 to 7.97]), and 3 years (OR: 3.30 [95% CI: 0.96 to 11.33]). There was no difference in mortality in PCI- versus CABG-treated patients at 1 year (OR: 1.00 [95% CI: 0.70 to 1.41]), 2 years (OR: 1.27 [95% CI: 0.83 to 1.94]), and 3 years (OR: 1.11 [95% CI: 0.66 to 1.86]). CONCLUSIONS Our analysis reveals no difference in mortality or major adverse cardiovascular or cerebrovascular events, for up to 3 years, between PCI and CABG for the treatment of ULMCA stenosis. However, PCI patients had a significantly higher risk of target vessel revascularization. In selected patients with ULMCA stenosis, PCI is emerging as an acceptable option.


Journal of the American College of Cardiology | 2013

Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography.

Hasan Jilaihawi; Niraj Doctor; Mohammad Kashif; Tarun Chakravarty; Asim Rafique; Moody Makar; Azusa Furugen; Mamoo Nakamura; James Mirocha; Mitch Gheorghiu; Jasminka Stegic; Kazuaki Okuyama; Daniel J. Sullivan; Robert J. Siegel; James K. Min; Swaminatha V. Gurudevan; Gregory P. Fontana; Wen Cheng; Gerald Friede; Takahiro Shiota; Raj R. Makkar

OBJECTIVES This study compared cross-sectional three-dimensional (3D) transesophageal echocardiography (TEE) to two-dimensional (2D) TEE as methods for predicting aortic regurgitation after transcatheter aortic valve replacement (TAVR). BACKGROUND Data have shown that TAVR sizing using cross-sectional contrast computed tomography (CT) parameters is superior to 2D-TEE for the prediction of paravalvular aortic regurgitation (AR). Three-dimensional TEE can offer cross-sectional assessment of the aortic annulus but its role for TAVR sizing has been poorly elucidated. METHODS All patients had severe symptomatic aortic stenosis and were treated with balloon-expandable TAVR in a single center. Patients studied had both 2D-TEE and 3D imaging (contrast CT and/or 3D-TEE) of the aortic annulus at baseline. Receiver-operating characteristic curves were generated for each measurement parameter using post-TAVR paravalvular AR moderate or greater as the state variable. RESULTS For the 256 patients studied, paravalvular AR moderate or greater occurred in 26 of 256 (10.2%) of patients. Prospectively recorded 2D-TEE measurements had a low discriminatory value (area under the curve = 0.52, 95% confidence interval: 0.40 to 0.63, p = 0.75). Average cross-sectional diameter by CT offered a high degree of discrimination (area under the curve = 0.82, 95% confidence interval: 0.73 to 0.90, p < 0.0001) and mean cross-sectional diameter by 3D-TEE was of intermediate value (area under the curve = 0.68, 95% confidence interval: 0.54 to 0.81, p = 0.036). CONCLUSIONS Cross-sectional 3D echocardiographic sizing of the aortic annulus dimension offers discrimination of post-TAVR paravalvular AR that is significantly superior to that of 2D-TEE. Cross-sectional data should be sought from 3D-TEE if good CT data are unavailable for TAVR sizing.

Collaboration


Dive into the Gregory P. Fontana's collaboration.

Top Co-Authors

Avatar

Raj Makkar

Cedars-Sinai Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Wen Cheng

Cedars-Sinai Medical Center

View shared research outputs
Top Co-Authors

Avatar

Martin B. Leon

Columbia University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Robert M. Kass

Cedars-Sinai Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sharo Raissi

Cedars-Sinai Medical Center

View shared research outputs
Top Co-Authors

Avatar

Craig R. Smith

Columbia University Medical Center

View shared research outputs
Top Co-Authors

Avatar

James Mirocha

Cedars-Sinai Medical Center

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge