Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Gualberto González-Sapienza is active.

Publication


Featured researches published by Gualberto González-Sapienza.


Journal of Applied Toxicology | 2014

Microcystins in potable surface waters: toxic effects and removal strategies

Amber Roegner; Beatriz Brena; Gualberto González-Sapienza; Birgit Puschner

In freshwater, harmful cyanobacterial blooms threaten to increase with global climate change and eutrophication of surface waters. In addition to the burden and necessity of removal of algal material during water treatment processes, bloom‐forming cyanobacteria can produce a class of remarkably stable toxins, microcystins, difficult to remove from drinking water sources. A number of animal intoxications over the past 20 years have served as sentinels for widespread risk presented by microcystins. Cyanobacterial blooms have the potential to threaten severely both public health and the regional economy of affected communities, particularly those with limited infrastructure or resources. Our main objectives were to assess whether existing water treatment infrastructure provides sufficient protection against microcystin exposure, identify available options feasible to implement in resource‐limited communities in bloom scenarios and to identify strategies for improved solutions. Finally, interventions at the watershed level aimed at bloom prevention and risk reduction for entry into potable water sources were outlined. We evaluated primary studies, reviews and reports for treatment options for microcystins in surface waters, potable water sources and treatment plants. Because of the difficulty of removal of microcystins, prevention is ideal; once in the public water supply, the coarse removal of cyanobacterial cells combined with secondary carbon filtration of dissolved toxins currently provides the greatest potential for protection of public health. Options for point of use filtration must be optimized to provide affordable and adequate protection for affected communities. Copyright


Analytical Chemistry | 2012

Isolation of alpaca anti-hapten heavy chain single domain antibodies for development of sensitive immunoassay.

Hee Joo Kim; Mark R. McCoy; Zuzana Majkova; Julie E. Dechant; Shirley J. Gee; Sofia Tabares-da Rosa; Gualberto González-Sapienza; Bruce D. Hammock

Some unique subclasses of Camelidae antibodies are devoid of the light chain, and the antigen binding site is comprised exclusively of the variable domain of the heavy chain (VHH). Although conventional antibodies dominate current assay development, recombinant VHHs have a high potential as alternative reagents for the next generation of immunoassay. We expressed VHHs from an immunized alpaca and developed a VHH-based immunoassay using 3-phenoxybenzoic acid (3-PBA), a major metabolite of pyrethroid insecticides as a model system. A phage VHH library was constructed, and seven VHH clones were selected by competitive binding with 3-PBA. The best immunoassay developed with one of these VHHs showed an IC(50) of 1.4 ng/mL (limit of detection (LOD) = 0.1 ng/mL). These parameters were further improved by using the phage borne VHH, IC(50) = 0.1 ng/mL and LOD = 0.01 ng/mL. Both assays showed a similar tolerance to methanol and dimethylsulfoxide up to 50% in assay buffer. The assay was highly specific to 3-PBA and its 4-hydroxylated derivative, 4-hydroxy 3-PBA, (150% cross reactivity) with negligible cross reactivity with other tested structural analogues, and the recovery from spiked urine sample ranged from 80 to 112%. In conclusion, a highly specific and sensitive VHH for 3-PBA was developed using sequences from immunized alpaca and phage display technology for antibody selection.


Analytical Chemistry | 2011

Competitive selection from single domain antibody libraries allows isolation of high-affinity antihapten antibodies that are not favored in the llama immune response.

Sofia Tabares-da Rosa; Martín Rossotti; Carmen Carleiza; Federico Carrión; Otto Pritsch; Ki Chang Ahn; Bruce D. Hammock; Gualberto González-Sapienza

Single-domain antibodies (sdAbs) found in camelids lack a light chain, and their antigen-binding site sits completely in the heavy-chain variable domain (VHH). Their simplicity, thermostability, and ease in expression have made VHHs highly attractive. Although this has been successfully exploited for macromolecular antigens, their application to the detection of small molecules is still limited to a very few reports, mostly describing low-affinity VHHs. Using triclocarban (TCC) as a model hapten, we found that conventional antibodies, IgG1 fraction, reacted with free TCC with a higher relative affinity (IC(50) 51.0 ng/mL) than did the sdAbs (IgG2 and IgG3, 497 and 370 ng/mL, respectively). A VHH library was prepared, and by elution of phage with limiting concentrations of TCC and competitive selection of binders, we were able to isolate high-affinity clones, K(D) 0.98-1.37 nM (SPR), which allowed development of a competitive assay for TCC with an IC(50) = 3.5 ng/mL (11 nM). This represents a 100-fold improvement with regard to the performance of the sdAb serum fraction, and it is 100-fold better than the IC(50) attained with other antihapten VHHs reported thus far. Despite the modest overall antihapten sdAbs response in llamas, a small subpopulation of high-affinity VHHs is generated that can be isolated by careful design of the selection process.


Analytical Biochemistry | 2009

Magnetic bead-based phage anti-immunocomplex assay (PHAIA) for the detection of the urinary biomarker 3-phenoxybenzoic acid to assess human exposure to pyrethroid insecticides

Hee Joo Kim; Ki Chang Ahn; Andrés González-Techera; Gualberto González-Sapienza; Shirley J. Gee; Bruce D. Hammock

Noncompetitive immunoassays are advantageous over competitive assays for the detection of small molecular weight compounds. We recently demonstrated that phage peptide libraries can be an excellent source of immunoreagents that facilitate the development of sandwich-type noncompetitive immunoassays for the detection of small analytes, avoiding the technical challenges of producing anti-immunocomplex antibody. In this work we explore a new format that may help to optimize the performance of the phage anti-immunocomplex assay (PHAIA) technology. As a model system we used a polyclonal antibody to 3-phenoxybenzoic acid (3-PBA) and an anti-immunocomplex phage clone bearing the cyclic peptide CFNGKDWLYC. The assay setup with the biotinylated antibody immobilized onto streptavidin-coated magnetic beads significantly reduced the amount of coating antibody giving identical sensitivity (50% saturation of the signal (SC(50))=0.2-0.4ng/ml) to the best result obtained with direct coating of the antibody on ELISA plates. The bead-based assay tolerated up to 10 and 5% of methanol and urine matrix, respectively. This assay system accurately determined the level of spiked 3-PBA in different urine samples prepared by direct dilution or clean-up with solid-phase extraction after acidic hydrolysis with overall recovery of 80-120%.


Analytical Chemistry | 2011

Noncompetitive Phage Anti-Immunocomplex Real-Time Polymerase Chain Reaction for Sensitive Detection of Small Molecules

Hee Joo Kim; Mark R. McCoy; Shirley J. Gee; Gualberto González-Sapienza; Bruce D. Hammock

Immuno polymerase chain reaction (IPCR) is an analytical technology based on the excellent affinity and specificity of antibodies combined with the powerful signal amplification of polymerase chain reaction (PCR), providing superior sensitivity to classical immunoassays. Here we present a novel type of IPCR termed phage anti-immunocomplex assay real-time PCR (PHAIA-PCR) for the detection of small molecules. Our method utilizes a phage anti-immunocomplex assay (PHAIA) technology in which a short peptide loop displayed on the surface of the M13 bacteriophage binds specifically to the antibody-analyte complex, allowing the noncompetitive detection of small analytes. The phagemid DNA encoding this peptide can be amplified by PCR, and thus, this method eliminates hapten functionalization or bioconjugation of a DNA template while providing improved sensitivity. As a proof of concept, two PHAIA-PCRs were developed for the detection of 3-phenoxybenzoic acid, a major urinary metabolite of some pyrethroid insecticides, and molinate, a herbicide implicated in fish kills. Our results demonstrate that phage DNA can be a versatile material for IPCR development, enabling universal amplification when the common element of the phagemid is targeted or specific amplification when the real time PCR probe is designed to anneal the DNA encoding the peptide. The PHAIA-PCRs proved to be 10-fold more sensitive than conventional PHAIA and significantly faster using magnetic beads for rapid separation of reactants. The assay was validated with both agricultural drain water and human urine samples, showing its robustness for rapid monitoring of human exposure or environmental contamination.


Analytical Biochemistry | 2010

Development of a noncompetitive phage anti-immunocomplex assay for brominated diphenyl ether 47

Hee Joo Kim; Martín Rossotti; Ki Chang Ahn; Gualberto González-Sapienza; Shirley J. Gee; Ruthie Musker; Bruce D. Hammock

We present a new application of the noncompetitive phage anti-immunocomplex assay (PHAIA) by converting an existing competitive assay to a versatile noncompetitive sandwich-type format using immunocomplex binding phage-borne peptides to detect the brominated flame retardant, brominated diphenyl ether 47 (BDE 47). Three phage-displayed 9-mer disulfide-constrained peptides that recognize the BDE 47-polyclonal antibody immunocomplex were isolated. The resulting PHAIAs showed variable sensitivities, and the most sensitive peptide had a dose-response curve with an SC(50) (concentration of analyte producing 50% saturation of the signal) of 0.7ng/ml BDE 47 and a linear range of 0.3-2ng/ml, which was nearly identical to the best heterologous competitive format (IC(50) of 1.8ng/ml, linear range of 0.4-8.5/ml). However, the PHAIA was 1400-fold better than homologous competitive assay. The validation of the PHAIA with extracts of house furniture foam as well as human and calf sera spiked with BDE 47 showed overall recovery of 80-113%. The PHAIA was adapted to a dipstick format (limit of detection of 3.0ng/ml), and a blind test with six random extracts of local house furniture foams showed that the results of the PHAIA and dipstick assay were consistent, giving the same positive and negative detection.


Biosensors and Bioelectronics | 2015

Development of a highly sensitive noncompetitive electrochemical immunosensor for the detection of atrazine by phage anti-immunocomplex assay.

Andrés González-Techera; María Alicia Zon; Patricia Gabriela Molina; Héctor Fernández; Gualberto González-Sapienza; Fernando Javier Arévalo

The development of immunosensors for the detection of small molecules is of great interest because of their simplicity, high sensitivity and extended analytical range. Due to their size, small compounds cannot be simultaneously recognized by two antibodies impeding their detection by noncompetitive two-site immunoassays, which are superior to competitive ones in terms of sensitivity, kinetics, and working range. In this work, we combine the advantages of magneto-electrochemical immunosensors with the improved sensitivity and direct proportional signal of noncompetitive immunoassays to develop a new Phage Anti-Immunocomplex Electrochemical Immunosensor (PhAIEI) for the detection of the herbicide atrazine. The noncompetitive assay is based on the use of recombinant M13 phage particles bearing a peptide that specifically recognizes the immunocomplex of atrazine with an anti-atrazine monoclonal antibody. The PhAIEI performed with a limit of detection (LOD) of 0.2 pg mL(-1), which is 200-fold better than the LOD obtained using the same antibody in an optimized conventional competitive ELISA, with a large increase in working range. The developed PhAIEI was successfully used to assay undiluted river water samples with no pretreatment and excellent recoveries. Apart from the first demonstration of the benefits of integrating phage anti-immunocomplex particles into electrochemical immunosensors, the extremely low and environmentally relevant detection limits of atrazine attained with the PhAIEIS may have direct applicability to fast and sensitive detection of this herbicide in the environment.


PLOS Neglected Tropical Diseases | 2013

A monoclonal antibody-based copro-ELISA kit for canine echinococcosis to support the PAHO effort for hydatid disease control in South America.

Noelia Morel; Gabriel Lassabe; Susana Elola; Mauricio Bondad; Silvia Herrera; Carlos Marí; Oscar Jensen; Gualberto González-Sapienza

Cystic echinococcosis is still a major concern in South America. While some regions show advances in the control of the disease, others have among the highest incidence in the world. To reverse this situation the Pan American Health Organization (PAHO) has launched a regional project on cystic echinococcosis control and surveillance. An early concern of the program was the lack of a standardized diagnostic tool to monitor infection in dogs, a key target of control programs. Under this premise, we have developed a new copro-ELISA test after extensive screening of a large panel of monoclonal antibodies (MAbs) and polyclonal sera, which performs with high standards of sensitivity (92.6%) and specificity (86.4%) as established by necropsy diagnosis of dogs. The key component of the test, MAbEg9 has a convenient IgG isotype and reacts with a periodate-resistant epitope found in high molecular weight components of the worm. Time-course analysis of experimentally infected dogs showed that even animals with a very low number of parasites could be detected as early as day 20 post infection. The test was formulated in a ready-to-use kit format with proven stability of each component for a minimum of 3 months at room temperature. This characteristic facilitates its standardized use and shipping to other laboratories, which was demonstrated by the identical results obtained by two different laboratories in Peru and our own laboratory when a large number of field samples were analyzed independently in a blind fashion.


Journal of Environmental Management | 2013

Limited analytical capacity for cyanotoxins in developing countries may hide serious environmental health problems: simple and affordable methods may be the answer.

Macarena Pírez; Gualberto González-Sapienza; Daniel Sienra; Graciela Ferrari; Beatríz M. Brena

In recent years, the international demand for commodities has prompted enormous growth in agriculture in most South American countries. Due to intensive use of fertilizers, cyanobacterial blooms have become a recurrent phenomenon throughout the continent, but their potential health risk remains largely unknown due to the lack of analytical capacity. In this paper we report the main results and conclusions of more than five years of systematic monitoring of cyanobacterial blooms in 20 beaches of Montevideo, Uruguay, on the Rio de la Plata, the fifth largest basin in the world. A locally developed microcystin ELISA was used to establish a sustainable monitoring program that revealed seasonal peaks of extremely high toxicity, more than one-thousand-fold greater than the WHO limit for recreational water. Comparison with cyanobacterial cell counts and chlorophyll-a determination, two commonly used parameters for indirect estimation of toxicity, showed that such indicators can be highly misleading. On the other hand, the accumulated experience led to the definition of a simple criterion for visual classification of blooms, that can be used by trained lifeguards and technicians to take rapid on-site decisions on beach management. The simple and low cost approach is broadly applicable to risk assessment and risk management in developing countries.


Biosensors and Bioelectronics | 2012

Ultra-sensitive electrochemical immunosensor using analyte peptidomimetics selected from phage display peptide libraries

Fernando Javier Arévalo; Andrés González-Techera; María Alicia Zon; Gualberto González-Sapienza; Héctor Fernández

Immunosensors for small analytes have been a great addition to the analytical toolbox due to their high sensitivity and extended analytical range. In these systems the analyte is detected when it competes for binding to the detecting antibody with a tracer compound. In this work we introduce the use of phage particles bearing peptides that mimic the target analyte as surrogates for conventional tracers. As a proof of concept, we developed a magneto-electrochemical immunosensor (EI) for the herbicide molinate and compare its performance with conventional formats. Using the same anti-molinate antibody and phage particles bearing a molinate peptidomimetic, the EI performed with an IC(50) of 0.15 ngmL(-1) (linear range from 4.4 × 10(-3) to 10 ngmL(-1)). Compared to the conventional ELISA, the EI was faster (minutes), performed with a much wider linear range, and the detection limit that was 2500-fold lower. The EI produced consistent measurements and could be successfully used to assay river water samples with excellent recoveries. By using the same EI with a conventional tracer, we found that an important contribution to the gain in sensitivity is due to the filamentous structure of the phage (9 × 1000 nm) which works as a multienzymatic tracer, amplifying the competitive reaction. Since phage-borne peptidomimetics can be selected from phage display libraries in a straightforward systematic manner and their production is simple and inexpensive, they can contribute to facilitate the development of ultrasensitive biosensors.

Collaboration


Dive into the Gualberto González-Sapienza's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Shirley J. Gee

University of California

View shared research outputs
Top Co-Authors

Avatar

Hee Joo Kim

University of California

View shared research outputs
Top Co-Authors

Avatar

Lucia Vanrell

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ki Chang Ahn

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mark R. McCoy

University of California

View shared research outputs
Top Co-Authors

Avatar

Amber Roegner

University of California

View shared research outputs
Researchain Logo
Decentralizing Knowledge