Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Gurpal Singh is active.

Publication


Featured researches published by Gurpal Singh.


Journal of Bone and Joint Surgery, American Volume | 2013

Periprosthetic tissue metal content but not serum metal content predicts the type of tissue response in failed small-diameter metal-on-metal total hip arthroplasties.

Christoph H. Lohmann; H. Meyer; J.V. Nuechtern; Gurpal Singh; S. Junk-Jantsch; H. Schmotzer; Michael M. Morlock; G. Pflüger

BACKGROUND Tissue responses to periprosthetic metal wear debris are complex and poorly understood. There are two predominant tissue responses: a nonspecific macrophage-mediated granulomatous response and lymphocyte-dominated response, which has immunological memory and is mediated by T cells. Delayed hypersensitivity-type responses may accelerate aseptic loosening of arthroplasty implants. We hypothesized that the metal content of periprosthetic tissue but not of serum would be predictive of the type of tissue response to metal wear debris. METHODS We examined twenty-eight total hip arthroplasty implant retrievals from twenty-seven patients who had undergone revision arthroplasty at one institution. Indications for revision were pain and/or osteolysis; one patient had recurrent dislocations. Tissue samples were analyzed microscopically and the metal (Co, Cr, and Ni) content was determined. Explanted prosthetic components were examined for linear wear. Intraoperatively, periprosthetic metallosis was observed in twelve cases and formation of a bursa (pseudotumor) was observed in thirteen. The acetabular cup was loose in eleven cases, the femoral stem was loose in five, and both components were loose in five. RESULTS The metal (Co, Cr, and Ni) content of the periprosthetic tissue ranged from 1.4 to 4604.0 μg/g. Histologically, macrophages containing metal particles as well as diffuse and perivascular lymphocytic infiltration were observed. Fibrin exudation was also visible. Tissues that displayed a predominantly lymphocytic response had a mean metal content of 222.2 ± 52.9 μg/g, whereas those that displayed a macrophage-dominated response had a metal content of 3.0 ± 0.9 μg/g; this difference was significant (p = 0.001). The mean serum metal content did not differ significantly between the two subgroups (60.7 ± 13.4 compared with 43.7 ± 3.8 μg/L, p = 0.105). CONCLUSIONS An association between periprosthetic tissue metal content and hypersensitivity appears likely but needs to be validated with larger-scale retrieval studies. CLINICAL RELEVANCE This study contributes to the understanding of tissue responses to metal wear debris after joint replacement and the factors that are predictive of a type-IV lymphocyte-dominated hypersensitivity reaction.


World journal of orthopedics | 2014

Metallic debris from metal-on-metal total hip arthroplasty regulates periprosthetic tissues.

Christoph H. Lohmann; Gurpal Singh; Hans-Georg Willert; Gottfried H. Buchhorn

The era of metal-on-metal (MoM) total hip arthroplasty has left the orthopaedic community with valuable insights and lessons on periprosthetic tissue reactions to metallic debris. Various terms have been used to describe the tissue reactions. Sometimes the nomenclature can be confusing. We present a review of the concepts introduced by Willert and Semlitsch in 1977, along with further developments made in the understanding of periprosthetic tissue reactions to metallic debris. We propose that periprosthetic tissue reactions be thought of as (1) gross (metallosis, necrosis, cyst formation and pseudotumour); (2) histological (macrophage-dominated, lymphocyte-dominated or mixed); and (3) molecular (expression of inflammatory mediators and cytokines such as interleukin-6 and tumor necrosis factor-alpha). Taper corrosion and modularity are discussed, along with future research directions to elucidate the antigen-presenting pathways and material-specific biomarkers which may allow early detection and intervention in a patient with adverse periprosthetic tissue reactions to metal wear debris.


Journal of Biomedical Materials Research Part A | 2013

Large-diameter metal-on-metal total hip arthroplasties: a page in orthopedic history?

Gurpal Singh; H. Meyer; Marcel Ruetschi; Kathrin Chamaon; Bernd Feuerstein; Christoph H. Lohmann

Large-diameter metal-on-metal (MoM) bearings evolved from the success of hip resurfacing. These implants were used in revision surgery in cases with well-fixed acetabular cups but loose or failed femoral stems, to avoid cup revision. Early data showed low rates of dislocation and potentially low wear profiles due to better fluid film lubrication. The risk of impingement was also thought to be low due to the increased head-neck ratio. Subsequently large-diameter MoM heads gained popularity in primary hip replacement. Recent data has emerged on the unacceptably high revision rates among patients with large-diameter MoM total hip arthroplasties (THAs), high blood levels of metal ions, and adverse tissue reactions. The head-neck (cone-taper) modular interface probably represents the weak link in large metal heads that have been used on conventional tapers. Increased torque of the large head, micromotion, and instability at the cone-taper interface, synergistic interactions between corrosion and wear, edge loading, low clearance, and psoas impingement are the likely causes for early failure of these prostheses.


Journal of Bone and Joint Surgery-british Volume | 2013

Restoring the anatomical tibial slope and limb axis may maximise post-operative flexion in posterior-stabilised total knee replacements.

Gurpal Singh; J. H. Tan; B. Y. Sng; Friedemann Awiszus; Christoph H. Lohmann; Saminathan Suresh Nathan

The optimal management of the tibial slope in achieving a high flexion angle in posterior-stabilised (PS) total knee replacement (TKR) is not well understood, and most studies evaluating the posterior tibial slope have been conducted on cruciate-retaining TKRs. We analysed pre- and post-operative tibial slope differences, pre- and post-operative coronal knee alignment and post-operative maximum flexion angle in 167 patients undergoing 209 TKRs. The mean pre-operative posterior tibial slope was 8.6° (1.3° to 17°) and post-operatively it was 8.0° (0.1° to 16.7°). Multiple linear regression analysis showed that the absolute difference between pre- and post-operative tibial slope (p < 0.001), post-operative coronal alignment (p = 0.02) and pre-operative range of movement (p < 0.001) predicted post-operative flexion. The variance of change in tibial slope became larger as the post-operative maximum flexion angle decreased. The odds ratio of having a post-operative flexion angle < 100° was 17.6 if the slope change was > 2°. Our data suggest that recreation of the anatomical tibial slope appears to improve maximum flexion after posterior-stabilised TKR, provided coronal alignment has been restored.


Foot & Ankle International | 2012

Neuroanatomical basis for the tarsal tunnel syndrome.

Gurpal Singh; V. P. Kumar

Background: The results of surgical treatment for tarsal tunnel syndrome have been suboptimal, especially in the absence of space-occupying lesions. We attribute this to a poor understanding of the detailed anatomy of the ‘tarsal tunnel’ and potential sites of nerve compression. Methods: This study involved the dissection of 19 cadaveric feet. All findings and measurements were documented with digital photography and digital calipers. Results: This study demonstrated three well-defined, tough fascial septae in the sole of the foot. In addition to the flexor retinaculum and the abductor hallucis, two of these septae represented potential sites of compression of the posterior tibial nerve and its branches. The medial plantar nerve may be entrapped under the medial septum. However, in 16 of 19 feet, the medial plantar nerve did not traverse beneath the septum. The lateral plantar nerve traversed beneath the medial septum in all specimens. The nerve to abductor digiti minimi may be trapped under the medial and intermediate septum. Conclusion: We detailed the anatomical relationship of the nerve branches relative to the fibrous septae and found that the medial plantar nerve did not traverse a septae in all specimens. Clinical Relevance: We believe better understanding of the anatomical relationships of the tarsal tunnel and a clear communication system among anatomists, neuroradiologists and foot and ankle surgeons will facilitate accurate preoperative localization of the site of nerve compression possibly leading to better outcomes. Level of Evidence: IV, Retrospective Case Control Study


Journal of Biomedical Materials Research Part A | 2015

Metallic wear debris may regulate CXCR4 expression in vitro and in vivo

Andreas Drynda; Gurpal Singh; Gottfried H. Buchhorn; Friedemann Awiszus; Marcel Ruetschi; Bernd Feuerstein; Stefanie Kliche; Christoph H. Lohmann

CXCR4, the chemokine receptor for CXCL12, also known as SDF-1 (stromal cell derived factor-1), has been shown to play a pivotal role in bone metastasis, inflammatory, and autoimmune conditions but has not been investigated in periprosthetic osteolysis. We co-cultured osteoblast-like cells with increasing concentrations of metallic (Co-35Ni-20Cr-10Mo and Co-28Cr-6Mo) and Co-ions simulating wear debris. Real-time polymerase chain reaction (RT-PCR) and Western blotting were used to quantify gene and protein expression of CXCR4. The expression of tumor necrosis factor-alpha (TNF-α) and the effects of AMD3100 (bicyclam) on both CXCR4 and TNF-α expression among these cells was investigated. RT-PCR showed an increase in CXCR4 mRNA (7.5-fold for MG63 and 4.0-fold for SaOs-2 cells) among cells co-cultured with metal alloy particles. Western blotting showed a time-dependent increase in protein expression of CXCR4. The attempted blockade of CXCR4 by its known competitive receptor agonist AMD3100 led to a significant inhibition TNF-α mRNA expression. Immunohistochemistry showed CXCR4 positivity among patients with failed metal-on-metal hip replacements and radiographic evidence of osteolysis. Our data collectively suggest that the CXCR4 chemokine is upregulated in a dose- and time-dependent manner in the presence of metallic wear debris.


Journal of Bone and Joint Surgery-british Volume | 2015

Does pathological fracture affect the rate of local recurrence in patients with a giant cell tumour of bone?: a meta-analysis

A. A. Salunke; Yongsheng Chen; X. Chen; Jun Hao Tan; Gurpal Singh; Bee Choo Tai; L. W. Khin; M. E. Puhaindran

We investigated whether the presence of a pathological fracture increased the risk of local recurrence in patients with a giant cell tumour (GCT) of bone. We also assessed if curettage is still an appropriate form of treatment in the presence of a pathological fracture. We conducted a comprehensive review and meta-analysis of papers which reported outcomes in patients with a GCT with and without a pathological fracture at presentation. We computed the odds ratio (OR) of local recurrence in those with and without a pathological fracture. We selected 19 eligible papers for final analysis. This included 3215 patients, of whom 580 (18.0%) had a pathological fracture. The pooled OR for local recurrence between patients with and without a pathological fracture was 1.05 (95% confidence interval (CI) 0.66 to 1.67, p = 0.854). Amongst the subgroup of patients who were treated with curettage, the pooled OR for local recurrence was 1.23 (95% CI 0.75 to 2.01, p = 0.417). A post hoc sample size calculation showed adequate power for both comparisons. There is no difference in local recurrence rates between patients who have a GCT of bone with and without a pathological fracture at the time of presentation. The presence of a pathological fracture should not preclude the decision to perform curettage as carefully selected patients who undergo curettage can have similar outcomes in terms of local recurrence to those without such a fracture.


Journal of Biomedical Materials Research Part B | 2014

Low-frequency sonication may alter surface topography of endoprosthetic components and damage articular cartilage without eradicating biofilms completely.

Gurpal Singh; Rita Hameister; Bernd Feuerstein; Friedemann Awiszus; H. Meyer; Christoph H. Lohmann

Two-stage exchange arthroplasty is the current standard of care for arthroplasty-related infections. Reinfection rates up to 30% are reported, and there is significant morbidity for the patient. In cases of failure, arthrodesis or amputation may result. Ultrasonic treatment has the potential to eradicate biofilms and avoid two-stage exchange arthroplasty. Data in the specific context of arthroplasty infections is scant, and there is debate regarding optimal frequency and intensity of treatment. Surface topography alterations of the endoprosthetic components and damage to adjacent bone and cartilage have not been investigated. We found incomplete biofilm eradication and significant increase in surface roughness (maximum peak-to-valley height) of cobalt-chrome unicondylar knee components as well as reduction in articular cartilage thickness area from 10 retrieved femoral heads after low-frequency sonication treatment according to manufacturer-specified recommendations. Our data collectively suggest that sonication treatment for biofilm eradication in arthroplasty infections may not be effective and surface topography alterations may potentially reduce implant longevity.


Journal of Arthroplasty | 2014

Ceramic Femoral Component Fracture in Total Knee Arthroplasty: An Analysis Using Fractography, Fourier-Transform Infrared Microscopy, Contact Radiography and Histology

Alexander P. Krueger; Gurpal Singh; Frank Timo Beil; Bernd Feuerstein; Wolfgang Ruether; Christoph H. Lohmann

Ceramic components in total knee arthroplasty (TKA) are evolving. We analyze the first case of BIOLOX delta ceramic femoral component fracture. A longitudinal midline fracture in the patellar groove was present, with an intact cement mantle and no bony defects. Fractographic analysis with laser scanning microscopy and white light interferometry showed no evidence of arrest lines, hackles, wake hackles, material flaws, fatigue or crack propagation. Analysis of periprosthetic tissues with Fourier-transform infrared (FT-IR) microscopy, contact radiography, histology, and subsequent digestion and high-speed centrifugation did not show ceramic debris. A macrophage-dominated response was present around polyethylene debris. We conclude that ceramic femoral component failure in this case was related to a traumatic event. Further research is needed to determine the suitability of ceramic components in TKA.


Journal of Arthroplasty | 2015

Stump Lengthening Procedure with Modular Endoprostheses — the Better Alternative to Disarticulations of the Hip Joint?

Marcel-Philipp Henrichs; Gurpal Singh; Georg Gosheger; Markus Nottrott; Arne Streitbuerger; Jendrik Hardes

We report outcomes of 28 patients after stump-lengthening procedures (SLPs) with modular tumor endoprostheses following high-thigh amputation and hip disarticulation over 11years. Mean follow up was 41.3months (range 7.4 to 133.6months). Mean Musculoskeletal Tumour Society Score was 56% (n=11); ten out of eleven patients alive used an exoprosthesis regularly. Complications occurred in 15 patients with infection being most common. In 2 cases, the prostheses had to be explanted. Our data suggest that SLP facilitates post-operative rehabilitation and prosthesis usage. Modular endoprostheses for stump-lengthening allow optimization of remnant soft-tissue envelope, reducing the risk of stump perforation.

Collaboration


Dive into the Gurpal Singh's collaboration.

Top Co-Authors

Avatar

Christoph H. Lohmann

Otto-von-Guericke University Magdeburg

View shared research outputs
Top Co-Authors

Avatar

Friedemann Awiszus

Otto-von-Guericke University Magdeburg

View shared research outputs
Top Co-Authors

Avatar

H. Meyer

Otto-von-Guericke University Magdeburg

View shared research outputs
Top Co-Authors

Avatar

Rita Hameister

Otto-von-Guericke University Magdeburg

View shared research outputs
Top Co-Authors

Avatar

Shamal Das De

National University of Singapore

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge